← Back to Directory

The Environment (Protection) Rules, 1986

The Environment (Protection) Rules, 1986

Raw JSON API

Sections

1. Short title and commencement.

Section 1

2. Definitions.

Section 2

3. Standards for emission or discharge of environmental pollutants.

Section 3

4. Directions.

Section 4

5. Prohibition and restriction on the location of industries and the carrying on processes and operations in different areas.

Section 5

7. Service of notice.

Section 7

8. Procedure for submission of samples for analysis, and the form of laboratory report thereon.

Section 8

9. Functions of environmental laboratories.

Section 9

10. Qualifications of Government Analyst.

Section 10

11. Manner of giving notice.

Section 11

1. Establishment of cooling arrangement and polishing tank for recycling the excess condensate water to process or utilities or allied units.

Section 1

2. Effluent Treatment Plant to be stabilized one month prior to the start of the crushing season and continue to operate one month after the crushing season.

Section 2

3. During no demand period for irrigation, the treated effluent to be stored in a seepage proof lined pond having 15 days holding capacity only.

Section 3

4. Flow meter to be installed in all water abstraction points and usage of fresh water to be minimized.

Section 4

5. Suitable Air pollution control devices to be installed to meet the particulate matter emission standard.

Section 5

5. Thermal power plants

Section 5

3. The treated effluent shall be allowed to be discharged in the ambient environment only after exhausting options for reuse in industrial process/ irrigation in order to minimise freshwater usage.

Section 3

4. Any textile unit attached with the Common Effluent Treatment Plant (CETP) shall achieve the inlet and treated effluent quality standards as specified in serial number 55 of Schedule-I to the Environment (Protection) Rules, 1986 and shall also be jointly and severally responsible for ensuring compliance.

Section 4

5. The standalone Micro, Small and Medium Enterprises (MSMEs) as per the MSME Development Act, 2006 shall meet the values specified above.

Section 5

6. The standalone large scale units shall meet the values specified above; however, CPCB or SPCBs/ PCCs with the approval of CPCB, may mandate Zero Liquid Discharge in Large scale units in environmentally sensitive/ critical areas.

Section 6

7. The TDS value with respect to treated effluent shall be 2100 milligramme per litre; however, in case where TDS in intake water is above 1100 milligramme per litre, a maximum contribution up to 1000 milligramme per litre shall be permitted provided the maximum value of 3100 milligramme per litre is not exceeded in the treated effluent.]

Section 7

7. Composite woolen mills Concentration not to exceed, milligramme per litre (except for pH and bio-assay) Common: Suspended solids 100 PH 5.5 - 9.0 [BOD (3 days at 27ºC)] 100 Oil and grease 10 Bio-assay 90% survival of fish after 96 hours Special: Total chromium (as Cr) 2 Sulphide (as S) 2 Phenolic Compounds (as C 6 H 5 OH) 5

Section 7

11. Stone crushing unit]

Section 11

14. Small Pulp and Paper Industry

Section 14

15. Fermentation Industry (Distilleries, Maltries and Breweries) Concentration in the effluent not to exceed milligramme per litre (except for pH and colour and odour) pH 5.5 - 9.0 Colour and odour [All efforts should be made to remove colour and unpleasant odour as far as practicable. Suspended solids 100 [BOD (3 days at 27 ° C)] - Disposal into inland surface water/river/streams 30mg1 - Disposal on land or for irrigation 100 mg/1.]

Section 15

15. Fermentation Industry (Distilleries, Maltries and Breweries)

Section 15

16. Leather Tanneries

Section 16

18. Iron Ore Mining and Ore Processing

Section 18

19. Calcium Carbide

Section 19

20. Carbon Black

Section 20

22. Nitric Acid (emission oxides of nitrogen)

Section 22

30. Integrated Iron and Steel PIants: Emissions (a) Coke oven Particulate matter 50 (b) Refractory material plant Particulate matter 150 II. Effluents Concentration in mg/litre (except for pH) (a) Coke oven By-product plant : pH 6.0-8.5 Suspended solids 100 Phenol 1.0 Cyanide 0.2 [BOD (3 days at 27°C)] 30 COD 250 Ammonical nitrozen 50 Oil & Grease 10 (b) Other plants such as sintering plant, blast furnace, steel melting and rolling mill : pH 6.0-9.0 Suspended solids 100 Oil & Grease 10 31. Re-he

Section 30

33. Thermal Power Plants

Section 33

34. Small Boilers

Section 34

36. Aluminium Plants

Section 36

38. Petrochemicals (Basic & intermediates)

Section 38

40. Pesticide manufacturing and Formulation Industry Effluents 1. Temperature Shall not exceed 5°C above the receiving water temperature 2. pH 6.5-8.5 3. Oil & Grease 10 4. [BOD (3 days at 27°C)] 30 5. Total suspended solids 100 6. Bio-assay test 90% survival of fish after 96% hrs. in 100% effluent 7.(a) Specific Pesticides: Benzene hexachloride 10 Carbonyl 10 DDT 10 Endosulfan 10 Diamethoate 450 Fenitrothion 10 Malathion 10 Phorate Methyl 10 Parathion 10 Phenthoate 10 Pyrethrums 10 Copper Oxych

Section 40

41. Tannery (after primary treatment) Effluents Disposal: Channel/Conduit Carrying waste-waters to Secondary treatment plants Type of Tanneries -Chrome tanneries/combined chrome and vegetable tanneries pH 6.5-9.0 SS Not to exceed 600 Chromium concentration after treatment in the chrome waste-water stream 45 -Vegetable tanneries pH 6.5-9.0 SS Not to exceed 600

Section 41
Part I

42. Paint Industry (Waste-water discharge) Effluents pH 6.0-8.5 Suspected Solids 100 [BOD (3 days at 27°C)] 50 Phenolics as C 6 H 5 OH 1.0 Oil & Grease 10.0 Bio-assay test 90% survival in 96 hours Lead as Pb 0.1 Chromium as Cr. 0.1 Hexavalent Total 2.0 Copper as Cu 2.0 Nickel as Ni 2.0 Zinc as Zn 5.0 Total heavy metals 7.0 43. Inorganic Chemical Industry (Waste-Water discharge) Part I (metal compounds of Chromium, Manganese, Nickel, Lead and Mercury) Effluents pH 6.0-8.5 Chromium as Cr Hexavalen

Section 42

2. At the present no limit for colour is given for liquid effluent. However, as far as possible colour should be removed.

Section 2

53. Large Pulp & Paper/News Print/Rayon Grade Plants of [Capacity above 24,000 MT per annum] Effluents Concentration in mg/1 except pH and TOCL pH 7.0-8.5 [BOD (3 days at 27°C)] 30 COD 350 Suspended solids 50 [Absorbable Organic Halogens (AOX) in effluent discharge 1.5 kg/ton of product with effect from the date of publication of this notification 1.0 kg/ton of product with effect from the 1 st day of March, 2008] Flow (Total waste-water discharge) **(i) Large pulp and paper 200 Cum/Ton of paper

Section 53

54. Small Pulp and Paper, Paper Plant of Capacity upto 24,000 MT/Annum: Effluents Category : A.* Agro-based Total Waste-water discharge 200 Cum/Ton of paper produced B. **Waste-paper based -do- 75 Cum/Ton of paper produced

Section 54

55. Common Effluent Treatment Plants: Effluents A. Primary Treatment (Inlet effluent quality for CETP) (Concentration in mg/1) pH 5.5-9.0 Temperature °C 45 Oil & Grease 20 Phenolic Compounds (as C 6 H 5 OH ) 5.0 Ammonical Nitrogen (as N) 50 Cyanide (as CN) 20 Chromium hexavalent (as Cr+6) 2.0 Chromium (total) (as Cr) 2.0 Copper (as Cu) 3.0 Lead (as Pb) 1.0 Nickel (as Ni) 3.0 Zinc (as Zn) 15 Arsenic (as As) 0.2 Mercury (as Hg) 0.01 Cadmium (as Cd) 1.0 Selenium (as Se) 0.05 Fluoride (as F) 15 Boro

Section 55

2. For each CETP and its constituent units, the State Board will prescribe standards as the local needs and conditions; these can be more stringent than those prescribed above. However, in case of clusters of units, the State Boards with the concurrence of CPCB in writing may prescribe suitable limits.

Section 2

64. Beehive hard coke oven Emission: 150 mg/Nm 3 (i) New unit Particulate matter (corrected to 6% CO 2 ) Hydrocarbons 25 ppm (ii) Existing units Particulate matter (corrected to 6% CO 2 ) 350 mg/Nm 3

Section 64

65. Briquette Industry (Coal) Emission: (a) Units having capacity less than 10 tonnes. Particulate matter (corrected to 6% CO 2 ) 350 mg/Nm 3 (b) Units having capacity 10 tonnes or more. Particulate matter (corrected to 6% CO 2 ) 150 mg/Nm 3

Section 65

66. Soft Coke Industry Particulate matter (corrected to 6% CO 2 ) 350 mg/Nm 3

Section 66

66. Soft Coke Industry

Section 66

67. Edible Oil & Vanaspati Industry Effluents Temperature Not more than 5°C above ambient temperature of the recipient water body. pH 6.5-8.5 Suspended solids 150 mg/l Oil and grease 20 mg/l BOD(3 days at 27°C) 100 mg/l COD 200 mg/l Waste-water discharge (i) Solvent extraction 2.0 cum/tonne of product (oil) (ii) Refinery/Vanaspati (refined oil Vanaspati) 2.0 cum/tonne of product (iii) Integrated unit of solvent extraction and refinery/vanaspati 4.0 cum/tonne of refined oil/vanaspati produced (iv

Section 67

68. Organic Chemicals manufacturing industry Effluents (a) Compulsory parameters pH 6.5-8.5 BOD(3 days at 27°C) 100 mg/l Oil and grease 10 mg/l Bio-assay test Minimum 90% survival after 96 hours with fish at 100% effluent) (b) Additional parameters (mg/1) Nitrate (as N) 10 Arsenic 0.2 Hexavalent Chromium 0.1 Total Chromium 1.0 Lead 0.1 Cyanide as CN 0.2 Zinc 0.5 Mercury 0.01 Copper 2.0 Nickel 2.0 Phenolics as C 6 H 5 OH 5.0 Sulphide 2.0

Section 68

70. Boilers(Small) Steam generation capacity (ton/hour) Particulate Emission matter mg/NM 3 less than 2 1200* 2 to less than 10 800* 10 to less than 15 600* 15 and above 150**

Section 70

71. Pesticides industry (i) Compulsory Parameters mg/l except pH pH 6.5-8.5 BOD (3 days at 27 o C) 100 Oil & Grease 10 Suspended solids 100 Bio-assay test Minimum 90% survival of fish after 96 hours with 90% effluent and 10% dilution water. Test shall be carried out as per IS : 6502-1971. (ii) Additional Parameters mg/l (a) Heavy metal Copper 1.0 Manganese 1.0 Zinc 1.0 Mercury 0.01 Tin 0.1 Any other like Nickel shall not exceed 5 times the drinking water standards (BIS) individually. (b) Organic

Section 71

72. Oil Drilling and Gas Extraction Industry A. Standards for Liquid Effluent 1.0 On-Shore facilities (For Marine Disposal) pH 5.5-9.0 Oil & Grease 10 mg/l Suspended solids 100 mg/l BOD (3 days at 27°C) 30 mg/l

Section 72

76. Emission Standard for SO² from Cupola furnace:

Section 76

1. Applicability. - The stipulations in respect of emissions and noise referred to in entry A and entry B shall apply to all new generator sets using petrol and kerosene as fuel, manufactured in or, imported into India: Provided that this provision shall not apply to,- (a) genset manufactured or, imported for the purpose of exports outside India; or, (b) genset intended for the purpose of Research and Development and not for sale or, captive use in India. 2. Requirement of certification. - Every

Section 1

1. Applicability.

Section 1

2. Requirement of certification. - Every manufacturer or importer (hereinafter referred to as manufacturer) of genset (hereinafter referred to as product) to which these conditions apply shall have a separate valid certificate of type approval for all the producproduct models for emission as well as noise norms being manufactured or imported. 3. Verification of conformity of production. - Every manufacturer shall submit its products to the verification for conformity of production for emission a

Section 2

2. Requirement of certification.

Section 2

3. Verification of conformity of production. - Every manufacturer shall submit its products to the verification for conformity of production for emission and noise, by any of the institutions, as applicable, every conformity of production year. 4. Sale of generator sets not complying with these conditions. - The sale of product model, not having valid type approval certificate, or not complying with the emission or noise norms, as determined by the verification for conformity of production, shal

Section 3

3. Verification of conformity of production.

Section 3

4. Sale of generator sets not complying with these conditions. - The sale of product model, not having valid type approval certificate, or not complying with the emission or noise norms, as determined by the verification for conformity of production, shall continue to be prohibited in India. 5. Requirement of conformance labeling. - (1) The manufacturer of the product shall affix a conformance label on the product containing the following requirements, namely:- (i) the label shall be durable and

Section 4

4. Sale of generator sets not complying with these conditions.

Section 4

5. Requirement of conformance labeling. - (1) The manufacturer of the product shall affix a conformance label on the product containing the following requirements, namely:- (i) the label shall be durable and legible; (ii) the label shall be affixed on a part necessary for normal operation of the product and not normally requiring replacement during the product life. (2) The conformance label must contain the following information, namely:- (i) name and address of the manufacturer (even, if the a

Section 5

5. Requirement of conformance labeling.

Section 5

6. Nodal agency. - (1) The Central Pollution Control Board shall be the nodal agency for implementation of these stipulations. (2) In case of any dispute or difficulty in implementation of these rules the matter shall be referred to the nodal agency. (3) The nodal agency shall constitute a Standing Committee for emission related issues and a National Committee for noise related issues, respectively to advice it on all matters related to the implementation of these rules including the dispute, if

Section 6

6. Nodal agency.

Section 6

7. Compliance and testing procedure. - (1) The compliance and testing procedure as published from time to time, if reviewed by Central Pollution Control Board shall be followed. (2) The Central Pollution Control Board may revise the compliance and testing procedure. (3) The institutes referred to in paragraph A and B above shall submit the testing and certification details in respect of emission or, noise, as applicable to the Central Pollution Control Board, annually and the Central Pollution C

Section 7

7. Compliance and testing procedure.

Section 7

4. Noise Level Standards 6.00 A.M. - 10.00 P.M. 10.00 P.M. - 6.00 A.M. Noise level Leq 75 dB (A) Leq 70 dB (A)

Section 4

92. Standards for Effluents from Textile Industry

Section 92

2. The quantity of effluent (litre per kilogram of product) shall not exceed 100, 250 and 80 in composite cotton textile industry, composite woollen textile industry and textile processing industry, respectively.

Section 2
Part 4

1. The abbreviations used in the Table shall mean as under: NOx - Oxides of Nitrogen; HC - Hydrocarbon; CO - Carbon Monoxide; and PM - Particulate Matter. 2. Smoke shall not exceed above value throughout the operating load points of the test cycle. 3. The testing shall be done as per D2 - 5 mode cycle of ISO: 8178- Part 4. 4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, impo

Section 1

1. The abbreviations used in the Table shall mean as under: NOx - Oxides of Nitrogen; HC - Hydrocarbon; CO - Carbon Monoxide; and PM - Particulate Matter. 2. Smoke shall not exceed above value throughout the operating load points of the test cycle. 3. The testing shall be done as per D2 - 5 mode cycle of ISO: 8178- Part 4. 4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, impo

Section 1

2. Smoke shall not exceed above value throughout the operating load points of the test cycle. 3. The testing shall be done as per D2 - 5 mode cycle of ISO: 8178- Part 4. 4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured

Section 2

2. Smoke shall not exceed above value throughout the operating load points of the test cycle. 3. The testing shall be done as per D2 - 5 mode cycle of ISO: 8178- Part 4. 4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured

Section 2

3. The testing shall be done as per D2 - 5 mode cycle of ISO: 8178- Part 4. 4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured or imported into India or, diesel genset (hereinafter referred to as 'product'), assembled or

Section 3

3. The testing shall be done as per D2 - 5 mode cycle of ISO: 8178- Part 4. 4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured or imported into India or, diesel genset (hereinafter referred to as 'product'), assembled or

Section 3

4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured or imported into India or, diesel genset (hereinafter referred to as 'product'), assembled or imported into India shall obtain Type Approval and comply with COP of their

Section 4

4. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. 5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured or imported into India or, diesel genset (hereinafter referred to as 'product'), assembled or imported into India shall obtain Type Approval and comply with COP of their

Section 4

5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured or imported into India or, diesel genset (hereinafter referred to as 'product'), assembled or imported into India shall obtain Type Approval and comply with COP of their product(s) for the emission limits which shall be valid for the next COP year or, the date of implementation of the revised norms specified above,

Section 5

5. Every manufacturer, importer or, assembler (hereinafter referred to as manufacturer) of the diesel engine (hereinafter referred to as 'engine') for genset application manufactured or imported into India or, diesel genset (hereinafter referred to as 'product'), assembled or imported into India shall obtain Type Approval and comply with COP of their product(s) for the emission limits which shall be valid for the next COP year or, the date of implementation of the revised norms specified above,

Section 5

6. Stack height (in metres), for genset shall be governed as per Central Pollution Control Board (CPCB) guidelines. General Conditions 1. Applicability - These conditions shall apply to all new engines for genset application and products manufactured, assembled or, imported into India, as the case may be : Provided that these rules, shall not apply to, - (a) any engine or, product, assembled or manufactured or imported, as the case may be, for the purpose of export outside India, or; (b) any eng

Section 6

1. Applicability - These conditions shall apply to all new engines for genset application and products manufactured, assembled or, imported into India, as the case may be : Provided that these rules, shall not apply to, - (a) any engine or, product, assembled or manufactured or imported, as the case may be, for the purpose of export outside India, or; (b) any engine or product intended for the purpose of sample limited to four in number and to be exported back within three months, and not for sa

Section 1

1. Applicability

Section 1

2. Requirement of certification - Every manufacturer of engine or product, as the case may be, shall have valid certificate(s) of Type Approval and COP for each COP year, for all engine models being manufactured or, for all engine or product models being imported, after the effective date for the emission limits, as specified above and the COP for the genset [of the power category 'upto 19KW' sold on or after [1st May, 2015] and of the power catogories 'more than 19kW upto 75 KW' and 'more than

Section 2

2. Requirement of certification

Section 2

3. Sale, import or use of engine or product not complying with these rules - No person shall sell, import or use an engine for genset application or, a product which is not having a valid Type Approval certificate and certificate of COP referred to in condition 2. 4. Requirement of conformance labeling. - (1) All the engines, individually or as part of the product shall be clearly engraved 'Genset Engine' on the cylinder block. (2) the engine or the product shall be affixed with a conformance la

Section 3

3. Sale, import or use of engine or product not complying with these rules

Section 3

4. Requirement of conformance labeling. - (1) All the engines, individually or as part of the product shall be clearly engraved 'Genset Engine' on the cylinder block. (2) the engine or the product shall be affixed with a conformance label meeting the following requirements,namely:- (a) the label shall be durable and legible; (b) the label shall be affixed on a part necessary for normal operation of the engine or the product and not normally requiring replacement during the life of the engine or

Section 4

4. Requirement of conformance labeling.

Section 4

5. Nodal Agency. - (1) The Central Pollution Control Board shall be the nodal agency for implementation of these rules. (2) In case of any dispute or difficulty in implementation of these rules, the matter shall be referred to the nodal agency. (3) The nodal agency shall constitute a Committee to advise it on all matters, including the disputed matters, related to the implementation of these rules. 6. Authorised agencies for certification. - The following institutions are authorised to carry out

Section 5

5. Nodal Agency.

Section 5

6. Authorised agencies for certification. - The following institutions are authorised to carry out such tests as they may deem necessary, for giving certificates of Type Approval and Conformity of Production tests for diesel engines or products and to give such certificates, namely:- (i) the Automotive Research Association of India, Pune (Maharashtra); (ii) the International Centre for Automotive Technology, Manesar (Haryana); (iii) the Indian Oil Corporation, Research and Development Centre, Fa

Section 6

6. Authorised agencies for certification.

Section 6

7. Compliance and testing procedure. - (1) The Compliance and Testing Procedure, as published by the Central Pollution Control Board shall be followed by all concerned. (2) The authorised agencies for certification shall submit the testing and certification details in respect of the emission to the Central Pollution Control Board annually. 8. Fuel Specification - The specification of commercial fuel applicable for diesel gensets shall be the same as applicable for commercial High Speed Diesel ap

Section 7

7. Compliance and testing procedure.

Section 7

8. Fuel Specification - The specification of commercial fuel applicable for diesel gensets shall be the same as applicable for commercial High Speed Diesel applicable for diesel vehicles in the area where product would be operated, from time to time, as per policy of Government of India. 9. Engine component or parts identification - All the details of engine components or parts responsible for the emission performance shall be clearly marked in English language.]

Section 8

8. Fuel Specification

Section 8

9. Engine component or parts identification - All the details of engine components or parts responsible for the emission performance shall be clearly marked in English language.]

Section 9

9. Engine component or parts identification

Section 9

95A. Genset run on dedicated Natural Gas (NG) or Liquid Petroleum Gas (LPG) :-

Section 95A

2. Dedicated NG or LPG genset engine shall mean a mono-fuel engine starting and operating with only one fuel, i.e., NG or LPG.

Section 2

3. NOX + NMHC or NOX + RHC shall be measured in case of dedicated NG or LPG genset engine. NMHC shall be equal to 0.3×Total Hydrocarbon (THC) in case of NG, and RHC is equal to 0.5×THC in case of LPG.

Section 3

4. These norms shall be applicable to Original Equipment Manufacturer (OEM) built dedicated NG or LPG genset engines.

Section 4

5. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies.

Section 5

6. Any of the following institutions shall undertake Type Approval and for verification of Conformity of Production for emission standards for engine products and to issue such certificates on compliance of the prescribed norms, namely:-

Section 6

7. Stack height (in metres), for genset shall be governed as per Central Pollution Control Board (CPCB) guidelines.

Section 7

95B. Genset run on Petrol and Natural Gas (NG) or Petrol and Liquid Petroleum Gas (LPG):-

Section 95B

2. Dual fuel engine operation shall mean a two - fuel system having petrol as a primary combustion fuel and NG or LPG as supplementary fuel, both in a certain proportion, throughout the engine operating zone. Such dual fuel Genset engine may operate on petrol stand-alone mode in absence of gaseous fuel i.e. NG or LPG.

Section 2

3. NMHC shall be equal to 0.3×THC in case of Natural Gas and RHC shall be equal to 0.5×THC in case of LPG.

Section 3

4. These norms shall be applicable to Original Equipment Manufacturer (OEM) built petrol and NG or petrol and LPG genset (upto 19 kW) powered by SI engine (upto 400 cc displacement). Conversion or Retrofitment of the existing petrol or Kerosene generator sets to run on petrol and NG or petrol and LPG shall not be permitted.

Section 4

5. The above emission limits shall be applicable for Type Approval and Conformity of Production (COP) undertaken by authorized agencies and shall be complied with petrol alone or petrol and NG or LPG fuel mode separately.

Section 5

6. Any of the following institutions shall undertake Type Approval and for verification of Conformity of Production for emission standards for engine products and to issue such certificates on compliance of the prescribed norms, namely:-

Section 6

7. NOX + THC shall be measured as emissions from petrol alone in bi-fuel fuel mode of operation. NOX + NMHC or NOX +RHC shall be measured in case of petrol and NG or petrol and LPG fuel mode of operation, respectively.

Section 7

95C. Genset run on Diesel and Natural Gas (NG) or Diesel and Liquid Petroleum Gas (LPG) :-

Section 95C

2. Dual fuel engine operation shall mean a two - fuel system having diesel as a primary combustion fuel and NG or LPG as supplementary fuel, both in a certain proportion, throughout the engine operating zone. Such dual fuel genset engine may operate on diesel stand-alone mode in absence of gaseous fuel i.e. NG or LPG.

Section 2

3. NOX + THC shall be measured as emission while diesel alone is used as fuel. NOX + NMHC or NOX + RHC shall be measured in case of diesel and NG or diesel and LPG dual fuel operation respectively. NMHC shall be equal to 0.3 × THC in case of NG and RHC as 0.5 × THC in case of LPG.

Section 3

4. These norms shall be applicable to Original Equipment Manufacturer (OEM) built diesel and NG or LPG Genset engines. Conversion or retro fitment of the existing diesel engines to run on diesel and NG or diesel and LPG shall not be permitted.

Section 4

5. The above mentioned emission limits shall be applicable for Type Approval and Conformity of Production (COP) carried out by authorised agencies. For Type Approval and COP for diesel and NG or diesel and LPG dual fuel operation engines, the emission and smoke limits prescribed in above Table shall be met in diesel alone or diesel and NG or diesel and LPG dual fuel mode separately.

Section 5

6. Any of the following institutions shall undertake Type Approval and for verification of Conformity of Production for emission standards for engine products and to issue such certificates on compliance of the prescribed norms, namely:-

Section 6

7. Stack height (in metres) for genset shall be governed as per Central Pollution Control Board (CPCB) guidelines.

Section 7

8. NOX + THC shall be measured as emissions from diesel alone in bi-fuel fuel mode of operation. NOX + NMHC or NOX +RHC shall be measured in case of diesel and NG or diesel and LPG fuel mode of operation, respectively.

Section 8

9. The emission standards for smoke and particulate matter shall be applicable, when diesel is used as fuel. Smoke limit prescribed in above Table shall not exceed throughout the operating load points of the test cycle.

Section 9

106. Mandatory Implementation of Dust Mitigation Measures for Construction and Demolition Activities for projects requiring Environmental Clearance

Section 106

4. Airport Noise Zones.

Section 4

5. Airport Noise Mapping.

Section 5

6. Protocol and Measurements Procedure.

Section 6

2. Large Pulp & Paper, News Print/Rayon grade plants of capacity above 24000 [tonne] /Annum Parameter Quantum Total Organic Chloride (TOCI) 2 [kg/tonne] of product.

Section 2

2. Whenever and wherever two consecutive values exceeds the limit specified above for the respective category, it shall be considered adequate reason to institute regular/continuous monitoring and further investigations.

Section 2