40. Pesticide manufacturing and Formulation Industry Effluents 1. Temperature Shall not exceed 5°C above the receiving water temperature 2. pH 6.5-8.5 3. Oil & Grease 10 4. [BOD (3 days at 27°C)] 30 5. Total suspended solids 100 6. Bio-assay test 90% survival of fish after 96% hrs. in 100% effluent 7.(a) Specific Pesticides: Benzene hexachloride 10 Carbonyl 10 DDT 10 Endosulfan 10 Diamethoate 450 Fenitrothion 10 Malathion 10 Phorate Methyl 10 Parathion 10 Phenthoate 10 Pyrethrums 10 Copper Oxych

(2) State Board may prescribed limit for chemical oxygen demand (COD) correlated with BOD limit.
(3) State Board may prescribe limit for total dissolved solids depending upon uses of recipient waterbody.
(4) Limits should be complied with at the terminal of the treatment unit before letting out of the factory boundary limits.
(5) For the compliance of limits, analysis should be done in the composite sample collected every hour for a period of 8 hours.
(c) Organics Phenol and phenolic compound as C 6 H 5 OH 1.0 (d) Inorganics : Arsenics(as As) 0.2 Cyanide (as CN) 0.2 Nitrate(as NO 3 ) 50.0 Phosphate(as P) 5.0 [Emissions] Not to exceed mg/NM 3 HCL 20 Cl 2 5 H 2 S 5 P 2 O 5 (as H 3 PO 4 ) 10 NH 3 30 Particulate matter with pesticides compounds 20 CH 3 Cl 20 HBr 5]
Note.