A.
Emission Standards for Stack for De-dusing Unit
A.
Emission Standards for Stack for De-dusing Unit
Particulate
matter
100mg/Nm3
Stack
height**
15.0 m
**
Stack height for De-dusting unit shall be calculated as H=74 Q
0.27, where H and Q are stack height in metre and particulate
matter (PM) emission in tonner/hr respectively, i.e.
Q
(kg/hr) Up to 2.71 2.72 – 7.86 7.87 –
17.96 17.97 – 35.29
H(metre) 15 20 25 30
Note:- Stack
attached to De-dusting unit shall have minimum height of 15.0
metres and would be atleast 2.50 metres above the top-most point
of the nearby building/shed or plant in the mine.
Note:-
B.
Fugitive Emission Standards
B.
Fugitive Emission Standards
Particulate
matter
Particulate
matter
1200
µ100mg/Nm3
1200
µ100mg/Nm3
Note:- Fugitive emission shall be monitored in the predominant downwind
direction at a distance0 25.0+2.0 metres from the source of
fugitive emission as per following :
Note:-
Area
Area
Monitoring
location
Monitoring
location
Mine face/Benches
Drilling
excavation and loading applicable for operation benches above
waterable
Haul Roads/Service
Roads
Haul roads to ore
processing plant, waste dumps and loading areas and service road
Crushing plant
Run-off mine
unloading at hopper, crushing areas, screens and transfer points.
Screening Plant
Screens, conveying
and transportation of ore discharge points
Ore Storage and
Loading
Intermediate stock
bin/pile areas ore stock bin/pile areas , wagon/truck loading
areas
Waste dump
Active
waste/reject dumps
C.
Effluent Standards
C.
Effluent Standards
pH
5.5-9.0
Suspended
solids (non-rainy day)
50
mg/l
Suspended
solids (railny day)
100
mg/l
Oil
and grease
10
mg/l
Note:- (I)
All efforts shall be made to reuse and rel-circulate the treated
effluent. (ii) The aforesaid effluent standards shall be
complied with for sewage, service water, beneficiation of ore
washwater and surface run-off put together
Note:-
Section 18 • The Environment (Protection) Rules, 1986
18. Iron Ore Mining and Ore Processing
the-environment-protection-rules-1986-sec-18.json
•
Section 18
{
"act_title": "The Environment (Protection) Rules, 1986",
"act_slug": "the-environment-protection-rules-1986",
"section_label": "Section",
"section": {
"number": "18",
"title": "18. Iron Ore\n\t\t\t\tMining and Ore Processing",
"chapter": null,
"content": "A.\n\t\t\t\tEmission Standards for Stack for De-dusing Unit\nA.\n\t\t\t\tEmission Standards for Stack for De-dusing Unit\nParticulate\n\t\t\t\tmatter\n100mg/Nm3\nStack\n\t\t\t\theight**\n15.0 m\n**\n\t\t\t\tStack height for De-dusting unit shall be calculated as H=74 Q\n\t\t\t\t0.27, where H and Q are stack height in metre and particulate\n\t\t\t\tmatter (PM) emission in tonner/hr respectively, i.e.\nQ\n\t\t\t\t(kg/hr) Up to 2.71 2.72 – 7.86 7.87 –\n\t\t\t\t17.96 17.97 – 35.29\nH(metre) 15 20 25 30\nNote:- Stack\n\t\t\t\tattached to De-dusting unit shall have minimum height of 15.0\n\t\t\t\tmetres and would be atleast 2.50 metres above the top-most point\n\t\t\t\tof the nearby building/shed or plant in the mine.\nNote:-\nB.\n\t\t\t\tFugitive Emission Standards\nB.\n\t\t\t\tFugitive Emission Standards\nParticulate\n\t\t\t\tmatter\nParticulate\n\t\t\t\tmatter\n1200\n\t\t\t\tµ100mg/Nm3\n1200\n\t\t\t\tµ100mg/Nm3\nNote:- Fugitive emission shall be monitored in the predominant downwind\n\t\t\t\tdirection at a distance0 25.0+2.0 metres from the source of\n\t\t\t\tfugitive emission as per following :\nNote:-\nArea\nArea\nMonitoring\n\t\t\t\tlocation\nMonitoring\n\t\t\t\tlocation\nMine face/Benches\nDrilling\n\t\t\t\texcavation and loading applicable for operation benches above\n\t\t\t\twaterable\nHaul Roads/Service\n\t\t\t\tRoads\nHaul roads to ore\n\t\t\t\tprocessing plant, waste dumps and loading areas and service road\nCrushing plant\nRun-off mine\n\t\t\t\tunloading at hopper, crushing areas, screens and transfer points.\nScreening Plant\nScreens, conveying\n\t\t\t\tand transportation of ore discharge points\nOre Storage and\n\t\t\t\tLoading\nIntermediate stock\n\t\t\t\tbin/pile areas ore stock bin/pile areas , wagon/truck loading\n\t\t\t\tareas\nWaste dump\nActive\n\t\t\t\twaste/reject dumps\nC.\n\t\t\t\tEffluent Standards\nC.\n\t\t\t\tEffluent Standards\npH\n5.5-9.0\nSuspended\n\t\t\t\tsolids (non-rainy day)\n50\n\t\t\t\tmg/l\nSuspended\n\t\t\t\tsolids (railny day)\n100\n\t\t\t\tmg/l\nOil\n\t\t\t\tand grease\n10\n\t\t\t\tmg/l\nNote:- (I)\n\t\t\t\tAll efforts shall be made to reuse and rel-circulate the treated\n\t\t\t\teffluent. (ii) The aforesaid effluent standards shall be\n\t\t\t\tcomplied with for sewage, service water, beneficiation of ore\n\t\t\t\twashwater and surface run-off put together\nNote:-",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
"prev_section": "16",
"next_section": "19"
}