    "act_title": "The Environment (Protection) Rules, 1986",
    "act_slug": "the-environment-protection-rules-1986",
    "section_label": "Section",
    "section": {
        "number": "18",
        "title": "18. Iron Ore\n\t\t\t\tMining and Ore Processing",
        "chapter": null,
        "content": "A.\n\t\t\t\tEmission Standards for Stack for De-dusing Unit\nA.\n\t\t\t\tEmission Standards for Stack for De-dusing Unit\nParticulate\n\t\t\t\tmatter\n100mg/Nm3\nStack\n\t\t\t\theight**\n15.0 m\n**\n\t\t\t\tStack height for De-dusting unit shall be calculated as H=74 Q\n\t\t\t\t0.27, where H and Q are stack height in metre and particulate\n\t\t\t\tmatter (PM) emission in tonner/hr respectively, i.e.\nQ\n\t\t\t\t(kg/hr) Up to 2.71 2.72 – 7.86 7.87 –\n\t\t\t\t17.96 17.97 – 35.29\nH(metre) 15 20 25 30\nNote:- Stack\n\t\t\t\tattached to De-dusting unit shall have minimum height of 15.0\n\t\t\t\tmetres and would be atleast 2.50 metres above the top-most point\n\t\t\t\tof the nearby building/shed or plant in the mine.\nNote:-\nB.\n\t\t\t\tFugitive Emission Standards\nB.\n\t\t\t\tFugitive Emission Standards\nParticulate\n\t\t\t\tmatter\nParticulate\n\t\t\t\tmatter\n1200\n\t\t\t\tµ100mg/Nm3\n1200\n\t\t\t\tµ100mg/Nm3\nNote:- Fugitive emission shall be monitored in the predominant downwind\n\t\t\t\tdirection at a distance0 25.0+2.0 metres from the source of\n\t\t\t\tfugitive emission as per following :\nNote:-\nArea\nArea\nMonitoring\n\t\t\t\tlocation\nMonitoring\n\t\t\t\tlocation\nMine face/Benches\nDrilling\n\t\t\t\texcavation and loading applicable for operation benches above\n\t\t\t\twaterable\nHaul Roads/Service\n\t\t\t\tRoads\nHaul roads to ore\n\t\t\t\tprocessing plant, waste dumps and loading areas and service road\nCrushing plant\nRun-off mine\n\t\t\t\tunloading at hopper, crushing areas, screens and transfer points.\nScreening Plant\nScreens, conveying\n\t\t\t\tand transportation of ore discharge points\nOre Storage and\n\t\t\t\tLoading\nIntermediate stock\n\t\t\t\tbin/pile areas ore stock bin/pile areas , wagon/truck loading\n\t\t\t\tareas\nWaste dump\nActive\n\t\t\t\twaste/reject dumps\nC.\n\t\t\t\tEffluent Standards\nC.\n\t\t\t\tEffluent Standards\npH\n5.5-9.0\nSuspended\n\t\t\t\tsolids (non-rainy day)\n50\n\t\t\t\tmg/l\nSuspended\n\t\t\t\tsolids (railny day)\n100\n\t\t\t\tmg/l\nOil\n\t\t\t\tand grease\n10\n\t\t\t\tmg/l\nNote:- (I)\n\t\t\t\tAll efforts shall be made to reuse and rel-circulate the treated\n\t\t\t\teffluent. (ii) The aforesaid effluent standards shall be\n\t\t\t\tcomplied with for sewage, service water, beneficiation of ore\n\t\t\t\twashwater and surface run-off put together\nNote:-",
        "footnote": "",
        "is_definition": false,
        "sort_order": 27
    },
    "prev_section": "16",
    "next_section": "19"
}