16. Leather Tanneries

Concentration in
the effluent not to exceed milligramme per litre (except for pH
and per cent sodium)
Inland
Surface Waters
Public
Sewers
Land
for Irrigation
Marine
Coastal Areas
(a)
(b)
(c)
(d)
Suspended Solids
100
600
200
100
[BOD (3 days at
27ºC)]
30
350
100
100
pH
6.0-9.0
6.0-9.0
6.0-9.0
6.0-9.0
Chlorides (as Cl)
1000
1000
600
-
Hexavalent
0.1
0.2
0.1
1.0
Chromium (Cr+6)
2.0
2.0
2.0
2.0
Total Chromium (as
Cr)
Sulphides (as S)
2.0
5.0
-
5.0
Sodium per cent
-
60
60
-
Boron (as B)
2.0
2.0
2.0
-
Oil and grease
10
20
10
20
[17.
Fertilizer Industry
A .- Effluent Standards
A .- Effluent Standards
(i) Straight Nitrogenous Fertilizer
Plant/Ammonia (Urea Plant), Calcium Ammonium Nitrate and Ammonium
Nitrate Fertilizers
(i) Straight Nitrogenous Fertilizer
Plant/Ammonia (Urea Plant), Calcium Ammonium Nitrate and Ammonium
Nitrate Fertilizers
Limiting concentration not to exceed in
milligram/litre (mg/l), except for pH
pH
6.5 to 8.5
Suspended Solids
100
Oil and Grease
10
Ammonical Nitrogen as N
50
Total Kjeldhal Nitrogen (TKN) as N
75
Free Ammonical Nitrogen as N
2.0
CN concentration
0.1
Nitrate Nitrogen as N
Urea Plant
10
Other than Urea Plant
20
(ii) Straight Phosphatic Fertilizer Plant
(ii) Straight Phosphatic Fertilizer Plant
pH
6.5 to 8.5
Suspended Solids
100
Oil and Grease
10
Fluoride
10
Dissolved Phosphate as P
5.0
(iii) Complex Fertilizer Plant and / or
NP/NPK(N-Nitrogen, P-Phosphorus and K-Potassium)
(iii) Complex Fertilizer Plant and / or
NP/NPK(N-Nitrogen, P-Phosphorus and K-Potassium)
pH
6.5 to 8.5
Suspended Solids
100
Oil and Grease
10
Ammonical Nitrogen as N
50
Total Kjeldhal Nitrogen (TKN) as N
75
Free Ammoniacal Nitrogen as N
4.0
Total Kjeldhal Nitrogen (TKN) as N
75
Free Ammoniacal Nitrogen as N
4.0
Nitrate Nitrogen as N
20
Dissolved Phosphate as P
5.0
Fluoride as F-
10
Note: (i)
Chromium salt shall not be used in cooling tower as algaecide.
Note:
(ii) The effluent shall be analysed for Vanadium
and Arsenic once in a year and analysis report shall be submitted
to the concerned State Pollution Control Board / Pollution
Control Committee.
B .- Emission Standards
B .- Emission Standards
(i) Straight Nitrogenous
(i) Straight Nitrogenous
(a) Ammonia Plant- Reformer
(a) Ammonia Plant- Reformer
Oxides of Nitrogen (as NO 2 )
400 mg/Nm 3
(b) Urea Plant – Prilling Tower
(b) Urea Plant – Prilling Tower
Particulate Matter
Pre 1982 units
150 mg/Nm 3
Post 1982 units
50 mg/Nm 3 **
(ii) Ammonium Nitrate/ Calcium Ammonium
Nitrate/NPK plant
(ii) Ammonium Nitrate/ Calcium Ammonium
Nitrate/NPK plant
Particulate Matter
Existing Plant
150 mg/Nm 3
New Plant
100 mg/ Nm 3
Ammonium as NH 3
Existing Plant
300 mg/Nm 3
New Plant
150 mg/Nm 3
Total Fluoride as F-
<10 mg/Nm 3 (only NPK Plant)
(iii) Phosphatic Fertilizer Plants –
Phosphoric Acid Plants/ Rock grinding and Acidulation SSP Plants
(iii) Phosphatic Fertilizer Plants –
Phosphoric Acid Plants/ Rock grinding and Acidulation SSP Plants
Particulate Matter
125 mg/Nm 3
Total Fluoride as F-
20 mg/Nm3
(iv) Nitric Acid Plant
(iv) Nitric Acid Plant
Oxides of Nitrogen (as NO 2 )
400 mg/Nm 3
*Values to be
reported at 3% O 2
** Total emission of
0.5 kg/ tonne of product.
Note: (i)
Fluoride norms shall be applicable only for NPK plant.
Note:
(ii) Plant
commissioned on or after the date of notification, shall be
treated as 'New Plant'.
(iii) The height of
the stack emitting Sulphur Dioxide, Oxides of Nitrogen or Oxides
of Phosphorus or acid mist shall be a minimum of 30 metres or as
per the formula H=14 (Q)0.3, whichever is more, where “H”
is the height of stack in metres and “Q” is the
maximum quantity of SO2 NOx or P2O5 equivalent expected to be
emitted in kg/hr through the stack at 100 per cent rated capacity
of the tail gas plant(s) and calculated as per the norms of
gaseous emission.
(iv) Tail Gas plants
having more than one stream or unit of Sulphuric Acid, Nitric
Acid or Phosphoric Acid at one location, the combined capacity of
all the streams or units for a particular acid shall be taken
into consideration for determining the stack height and
applicability of emission standards individually.
(iii) Tail gas plants having separate stack for
gaseous emission for the scrubbing unit, the height of this stack
shall be equal to main stack or 30 metres, whichever is higher.]