6.5-8.5
100
mg/l
10
mg/l
Minimum 90%
survival after 96 hours with fish at 100% effluent)
(mg/1)
10
0.2
0.1
1.0
0.1
0.2
0.5
0.01
2.0
2.0
5.0
2.0
Note.
(ii) These standards are not applicable to small-scale detergent (formulating units).
(iii) The standards for boiler emissions shall be applicable as per the existing emission regulations.
(iv) Industry covered under this group are halo-aliphatics, plasticizers, aromatics (alcohols, phenols, esters, acids and salts, aldehydes and ketone), substituted aromatics, aliphatic (alcohols, esters, acids, aldehydes, ketones, amines and amides) and detergents.
Sl.No.
Sl.No.
Sl.No.
Industry
Industry
Industry
Parameter
Parameter
Parameter
Standards
Standards
Standards
(1)
(1)
(1)
(2)
(2)
(2)
(3)
(3)
(3)
(4)
(4)
69.
Grain
Processing, Flour Mills, Paddy Processing, Pulse Making or
Grinding Mills
A-Emission
Standards
A-Emission
Standards
Capacity
(tonne per hour)
Limiting
Concentration in mg/Nm3
1 to
3
150
Particular matter
More
than 3
100
Notes:- (i)
All dust generating equipments or processes shall be provided
with dust extraction arrangement. (ii) The bag houses, etc.,
shall be connected to chimneys/stacks of 12 metres height or at
least 02 metres above the top most point of the building or shed
or plant in the industry. (iii) The unit shall channellse shop
floor/fugitive emissions through a stack of 12 metres height or
at least 02 metres above the top most point of the building or
shed or plant in the industry.
B-Effluent
Standards
B-Effluent
Standards
Limiting
value for concentration in mg/l except for pH
Inland
surface water
Public
sewar
Land
for irrigation
pH
5.5-9.0
5.5-9.0
5.5-9.0
Suspended Solids
100
600
200
Oils and Grease
10
20
10
BOD 3 days at 27°C
30
350
100
COD
250
-
-
C-Stormwater
Standards
C-Stormwater
Standards
(I) Stormwater for
a unit (having plot size atleast 250 square meters) shall not be
allowed to mix with scrubber water, effluent and/or floor
washings. (ii) Stormwater within the battery limits of a unit
shall be channelized through separate drain/pipe passing through
a HDPE lined pit having holding capacity of 10 minutes (hourly
average) of rainfall.
Notes.
(ii) BOD shall be allowed upto 350 mg/l for (applying on land, provided the land is designed and operated as a secondary treatment system with the requisite monitoring facilities. The drainage water from the land after secondary treatment has to satisfy a limit of 30 mg/l of BOD and 10 mg/l of nitrate expressed as "N". The net addition to ground water quality should not be more than 3 mg/l of BOD and 10 mg/l of nitrate expressed as "N".
(iii) BOD shall be allowed upto 350 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system.
(iv) Suspended solids shall be allowed upto 450 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system.
Section 68 • The Environment (Protection) Rules, 1986
68. Organic Chemicals manufacturing industry Effluents (a) Compulsory parameters pH 6.5-8.5 BOD(3 days at 27°C) 100 mg/l Oil and grease 10 mg/l Bio-assay test Minimum 90% survival after 96 hours with fish at 100% effluent) (b) Additional parameters (mg/1) Nitrate (as N) 10 Arsenic 0.2 Hexavalent Chromium 0.1 Total Chromium 1.0 Lead 0.1 Cyanide as CN 0.2 Zinc 0.5 Mercury 0.01 Copper 2.0 Nickel 2.0 Phenolics as C 6 H 5 OH 5.0 Sulphide 2.0
the-environment-protection-rules-1986-sec-68.json
•
Section 68
{
"act_title": "The Environment (Protection) Rules, 1986",
"act_slug": "the-environment-protection-rules-1986",
"section_label": "Section",
"section": {
"number": "68",
"title": "68. Organic Chemicals manufacturing industry Effluents (a) Compulsory parameters pH 6.5-8.5 BOD(3 days at 27°C) 100\nmg/l Oil and grease 10\nmg/l Bio-assay test Minimum 90%\nsurvival after 96 hours with fish at 100% effluent) (b) Additional parameters (mg/1) Nitrate (as N) 10 Arsenic 0.2 Hexavalent Chromium 0.1 Total Chromium 1.0 Lead 0.1 Cyanide as CN 0.2 Zinc 0.5 Mercury 0.01 Copper 2.0 Nickel 2.0 Phenolics as C 6 H 5 OH 5.0 Sulphide 2.0",
"chapter": null,
"content": "6.5-8.5\n100\nmg/l\n10\nmg/l\nMinimum 90%\nsurvival after 96 hours with fish at 100% effluent)\n(mg/1)\n10\n0.2\n0.1\n1.0\n0.1\n0.2\n0.5\n0.01\n2.0\n2.0\n5.0\n2.0\nNote.\n(ii) These standards are not applicable to small-scale detergent (formulating units).\n(iii) The standards for boiler emissions shall be applicable as per the existing emission regulations.\n(iv) Industry covered under this group are halo-aliphatics, plasticizers, aromatics (alcohols, phenols, esters, acids and salts, aldehydes and ketone), substituted aromatics, aliphatic (alcohols, esters, acids, aldehydes, ketones, amines and amides) and detergents.\nSl.No.\nSl.No.\nSl.No.\nIndustry\nIndustry\nIndustry\nParameter\nParameter\nParameter\nStandards\nStandards\nStandards\n(1)\n(1)\n(1)\n(2)\n(2)\n(2)\n(3)\n(3)\n(3)\n(4)\n(4)\n69.\nGrain\n\t\t\t\tProcessing, Flour Mills, Paddy Processing, Pulse Making or\n\t\t\t\tGrinding Mills\nA-Emission\n\t\t\t\tStandards\nA-Emission\n\t\t\t\tStandards\nCapacity\n\t\t\t\t(tonne per hour)\nLimiting\n\t\t\t\tConcentration in mg/Nm3\n1 to\n\t\t\t\t3\n150\nParticular matter\nMore\n\t\t\t\tthan 3\n100\nNotes:- (i)\n\t\t\t\tAll dust generating equipments or processes shall be provided\n\t\t\t\twith dust extraction arrangement. (ii) The bag houses, etc.,\n\t\t\t\tshall be connected to chimneys/stacks of 12 metres height or at\n\t\t\t\tleast 02 metres above the top most point of the building or shed\n\t\t\t\tor plant in the industry. (iii) The unit shall channellse shop\n\t\t\t\tfloor/fugitive emissions through a stack of 12 metres height or\n\t\t\t\tat least 02 metres above the top most point of the building or\n\t\t\t\tshed or plant in the industry.\nB-Effluent\n\t\t\t\tStandards\nB-Effluent\n\t\t\t\tStandards\nLimiting\n\t\t\t\tvalue for concentration in mg/l except for pH\nInland\n\t\t\t\tsurface water\nPublic\n\t\t\t\tsewar\nLand\n\t\t\t\tfor irrigation\npH\n5.5-9.0\n5.5-9.0\n5.5-9.0\nSuspended Solids\n100\n600\n200\nOils and Grease\n10\n20\n10\nBOD 3 days at 27°C\n30\n350\n100\nCOD\n250\n-\n-\nC-Stormwater\n\t\t\t\tStandards\nC-Stormwater\n\t\t\t\tStandards\n(I) Stormwater for\n\t\t\t\ta unit (having plot size atleast 250 square meters) shall not be\n\t\t\t\tallowed to mix with scrubber water, effluent and/or floor\n\t\t\t\twashings. (ii) Stormwater within the battery limits of a unit\n\t\t\t\tshall be channelized through separate drain/pipe passing through\n\t\t\t\ta HDPE lined pit having holding capacity of 10 minutes (hourly\n\t\t\t\taverage) of rainfall.\nNotes.\n(ii) BOD shall be allowed upto 350 mg/l for (applying on land, provided the land is designed and operated as a secondary treatment system with the requisite monitoring facilities. The drainage water from the land after secondary treatment has to satisfy a limit of 30 mg/l of BOD and 10 mg/l of nitrate expressed as \"N\". The net addition to ground water quality should not be more than 3 mg/l of BOD and 10 mg/l of nitrate expressed as \"N\".\n(iii) BOD shall be allowed upto 350 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system.\n(iv) Suspended solids shall be allowed upto 450 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system.",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
"prev_section": "67",
"next_section": "70"
}