67. Edible Oil & Vanaspati Industry Effluents Temperature Not more than 5°C above ambient temperature of the recipient water body. pH 6.5-8.5 Suspended solids 150 mg/l Oil and grease 20 mg/l BOD(3 days at 27°C) 100 mg/l COD 200 mg/l Waste-water discharge (i) Solvent extraction 2.0 cum/tonne of product (oil) (ii) Refinery/Vanaspati (refined oil Vanaspati) 2.0 cum/tonne of product (iii) Integrated unit of solvent extraction and refinery/vanaspati 4.0 cum/tonne of refined oil/vanaspati produced (iv

Note.
(ii) BOD shall be made stringent upto 30 mg/l if the recipient fresh water body is source of drinking water supply.
(iii) The standards for boiler emissions shall be applicable as prescribed under Schedule I of these rules.
Sl.No.
Sl.No.
Industry
Industry
Parameter
Parameter
Standard
Standard
(1)
(2)
(3)
(4)
68.
Organic Chemicals Manufacturing Industry
A. Effluent Standards
A. Effluent Standards
Limiting concentration in mg/1, except for pH and Bioassay
test
Compulsory parameters
pH
6.5-8.5
BOD 3 days, 27°C
100
Oil & Grease
10
Bioassay test +
Minimum 90% survival after 96 hours in 100%
effluent Additional parameters
Nitrate (as N)
10
Arsenic (as As)
0.2
Chromium Total
1.0
Lead (as pb)
0.1
Cyanide (as CN)
0.2
Zinc (as Zn)
5.0
Mercury (as Hg)
0.01
Copper (as Hg)
2.0
Nickel (as Nil)
2.0
Phenolics (as C6 H5 OH)
5.0
Sulphide
2.0
+ The Bioassay test shall be conducted as per IS: 6582+-1971
Note: (i) Industries covered under
this group include halo aliphatics, plasticizers, aromatics
(alcohols, phenols, esters, acids and salts, aldehydes and
ketones), substituted aromatics, aliphatics (alcohols, esters,
acids, aldehydes, ketones amines and amides) and detergents. (ii)
Though norms for COD are not mentioned here but, COD shall be
monitored. If the COD in treated effluent exceeds 250 mg/1, the
concerned industrial units discharging such effluent shall be
required to identify chemicals responsible for high COD in
effluent shall be required to identify chemicals responsible for
high COD in effluent. In case, these are found to be toxic as
defined under the Manufacture, Storage and Import of Hazardous
Chemicals Rules, 1989, the concerned industry shall install
tertiary treatment system. (iii) The above mentioned standards
shall not be applicable to small scale detergent formulating
units.
Note:
B. Emission Standards for Incinerator
B. Emission Standards for Incinerator
Limiting concentration in mg/Nm3, unless otherwise stated
Sampling Duration in minutes unless otherwise
stated
Particulate Matter
50
30 or more (for sampling about 300 litres of
emission)
HCI
50
30
SO2
200
30
CO
100
daily average
Total Organic Carbon
20
30
Total Dioxins Existing and Furans* Incinerator-
0.2 ng TEQ/Nm3
8 hours
New Incinerator
0.1 ng TEQ/Nm3
8 hours
Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+Cd+Th+Hg and their compounds
1.5
2 hours
*The existing plant shall comply with norms for
Dioxins and Furans as 0.1 ng TEQ/Nm3 by 1st January, 2014.
Note: (i) All monitored values shall
be corrected to 11% oxygen on dry basis. (ii) The CO2
concentration in tail gas shall not be less than 7%. (iii) In
case, halogenated organic waste is less than 1% by weight in
input waste all the facilities in twin chamber incinerator shall
be designated so as to achieve a minimum temperature of 850±25°
in primary chamber and 950°C in secondary combustion chamber
and with a gas residence time in secondary combustion chamber not
less than two or all the facilities in single chamber
incinerator for gaseous hazardous waste shall be designated so as
to achieve a minimum temperature of 950° in the combustion
chamber with a gas residence time not less than two seconds. (iv)
In case halogenated organic waste is more than 1% by weight in
input waste, waste shall be incinerated only in twin chamber
incinerators and all the facilities shall be designated to
achieve a minimum temperature of 850±25° C in primary
chamber and 1100°C in secondary combustion chamber with a gas
residence time in secondary combustion chamber not less than two
seconds. (v) Scrubber meant for scrubbing emissions shall not
be used as quencher. (vi) incineration plants shall be
operated (i.e. combustion chambers) with such temperature,
retention time and turbulence, as to achieve Total Organic Carbon
(TOC) content in the incineration ash and residue less than 3%
and their loss on ignition is less than 5% of them weight. In
case of non-conformity, ash and residue, as the case may be shall
be re-incinerated. (vii) The incinerator shall have a chimney
of at least thirty meters height.
Note:
C. Effluent Standards for Incinerator
C. Effluent Standards for Incinerator
Note: (i) Effluent from scrubber (s)
and floor washing shall flow through claosed conduit or pipe
network and be treated to comply with the effluent standards
mention at 'A' above (ii) The built up in Total Dissolved
Solids Solids (TDS) in waste water of floor washings shall not
exceed 1000 mg/over and above the TDS of raw water used.
Note:
D. Storm water
D. Storm water
Note: (i) Storm water shall not be allowed to mix
with scrubber water and/or floor washings. (ii) Storm water
shall be channellized through separate drains passing through a
HDPE lined pit having holding capacity of 10 minutes (hourly
average) of rainfall.
Note:
Substituted by Notification No. G.S.R. 608 (E) dated 21.7.2010 (w.e.f. 19.11.1986)
Substituted by Notification No. G.S.R. 608 (E) dated 21.7.2010 (w.e.f. 19.11.1986)