← Back to Directory

Jharkhand Building Byelaws 2016

Jharkhand Building Byelaws 2016

Raw JSON API

Sections

Preamble / Statement of Objects

Section 1

1. Short title, Extent and commencement.

Section 1

2. Definitions.

Section 2

3. Applicability.

Section 3

4. Deemed Permission.

Section 4

5. Application.

Section 5

6. Application for building permit.

Section 6

7. Certificates/Clearances.

Section 7

8. Signing the Plans.

Section 8

2. Wherever required under these bye-laws, the registered Structural Engineer, who has prepared the structural design, shall put his seal, and address on all the documents signed by him and shall also furnish a certificate to the effect that he shall supervise the structural part of the construction and shall be responsible for any structural failure except caused by unprecedented natural calamities in Form-W and except if the owner intimates that his services have been terminated.

Section 2

3. All aspects related to structural design, building surface, plumbing, electrical installation, sanitary arrangements, fire protection shall adhere to the specification, standards and code of practice recommended in the National Building Code of India, 2005 and any breach' thereof shall be deemed to be a breach of the requirements tinder these Bye laws.

Section 3

9. Fees.

Section 9

10. Permission.

Section 10

11. Duration of Permission.

Section 11

12. Information at the site of construction.

Section 12

13. Periodic report of Construction.

Section 13

15. Third Party certification.

Section 15

16. Accreditation and gradation of Architects/Engineers.

Section 16

17. Cancellation.

Section 17

18. Completion of Construction.

Section 18

19. Certificate for occupancy.

Section 19

20. Construction not according to plan.

Section 20

21. Single Window Clearance.

Section 21

22. Construction near important buildings.

Section 22

23. Construction near river front.

Section 23

24. Unsafe building.

Section 24

25. Demolition of building.

Section 25

26. Responsibility and Duty of the Applicant/Builder/Owner.

Section 26

27. Responsibility of Authority.

Section 27

28. Zoning.

Section 28

29. Different use of land.

Section 29

30. Restriction on permission.

Section 30

31. Requirement of Site.

Section 31

32. Distance from Electric lines.

Section 32

33. Plantation.

Section 33

34. Means of Access.

Section 34

35. Minimum size of plots and road width.

Section 35

36. Minimum setbacks & Height for non-high rise buildings.

Section 36

37. Minimum setbacks for high rise buildings.

Section 37

1. Up to 235 sqm. of plot and building ht. not exceeding 10m.

Section 1

2. Up to 1000 sqm. of plot and building ht. up to 16.4m.

Section 2

3. Above 1000 sqm. of plot area or building ht. of more than 16.4m.

Section 3

4. For commercial uses ground coverage is 50% of the plot area.

Section 4

38. General Conditions for Setback.

Section 38

39. Floor Area Ratio.

Section 39

40. Height of a building.

Section 40

41. Off Street Parking Space.

Section 41

2. For other institutions, transport, communication center and occupancy types not mentioned above, parking requirements shall be decided by the authority.

Section 2

3. For shops on plots up to 50 sq.m. parking space need not be insisted upon.

Section 3

4. For all apartment/multi dwelling of residential buildings:

Section 4

5. All non-residential buildings should provide one third area, out of the total car parking area, for parking of two wheelers. These two wheeler parking should have a minimum size of 1 m x 2 m. excluding the driveway. The minimum width of the drive way meant exclusively for 2 wheelers should be 3m.

Section 5

6. In addition to the parking spaces provided for building of mercantile (commercial) Industrial and storage type, one space of 3.50X7.50 meters for loading and unloading activities, for each 2000 sqm. of total area (as per FAR calculation) or fraction thereof shall be provided

Section 6

42. Requirement of Parts of Building.

Section 42

43. Exit Requirements.

Section 43

44. Interior open space.

Section 44

45. Height exemption of a building.

Section 45

46. Exemption in Open space.

Section 46

47. Mezzanine.

Section 47

48. Basement/Cellar.

Section 48

49. Provision of Lift.

Section 49

2. All sizes of lift (i.e. car inside, lift well, entrance, headroom etc.) shall be as per the requirements of N.B.C. or as per manufacturers specifications.

Section 2

3. All lifts shall be inspected at least once a year by the agency designated by the Authority. The Authority can also outsource the inspection of lifts.

Section 3

4. The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation.

Section 4

50. Barrier free access for the differently abled person.

Section 50

51. Rainwater harvesting system.

Section 51

52. Signs and outdoor display structures.

Section 52

53. Lightening Protection.

Section 53

54. Penal Action against Builders/Technical Personnel.

Section 54

55. Builder to register an association.

Section 55

56. Reference to the standards.

Section 56

57. Life Safety.

Section 57

58. For construction of Multi-storied building.

Section 58

59. Maintenance.

Section 59

60. Structural Safety Design, Standards and other Services requirements.

Section 60

1. IS: 456:2000 "Code of Practice for Plain and Reinforced Concrete

Section 1

2. IS: 800-1984 "Code of Practice for General construction in Steel

Section 2

3. IS: 801-1975 "Code of Practice for Use of Cold Formal Light Gauge Steel Structural Members in General Building Construction

Section 3
Part 2

4. IS 875 (Part 2): 1987 Design loads (other than earthquake) for buildings and structures Part 2 Imposed Loads

Section 4
Part 3

5. IS 875 (Part 3): 1987 Design loads (other than earthquake) for buildings and structures Part 3 Wind Loads

Section 5
Part 4

6. IS 875 (Part 4): 1987 Design loads (other than earthquake) for buildings and structures Part 4 Snow Loads

Section 6
Part 5

7. IS 875 (Part 5): 1987 Design loads (other than earthquake) for buildings and structures Part 5 special loads and load combination

Section 7

8. IS: 883:1966 "Code of Practice for Design of Structural Timber in Building

Section 8

9. IS: 1904:1987 "Code of Practice for Structural safety or Buildings: Foundation"

Section 9

10. IS 1905:1987 "Code of Practice for Structural Safety of Buildings: Masonry Wall

Section 10
Part I

11. IS 2911 (Part I): Section 1: 1979 "Code of Practice for Design and Construction of Pile Foundation Section 1

Section 1

12. IS: 1893-2002 "Criteria for Earthquake Resistant Design of Structures (Fifth Revision)"

Section 12

13. Is: 13920-1993 "Ductile Detailing of Reinforced concrete Structures subjected to Seismic Forces - Code of Practice"

Section 13

14. IS:4326-1993 "Earthquake Resistant Design and Construction of Buildings- Code of Practice (Second Revision)"

Section 14

15. IS: 13828-1993 "Improving Earthquake Resistance of Low Strength Masonry Buildings - Guidelines"

Section 15

16. IS:13827-1993 "Improving Earthquake Resistance of Earthen Buildings - Guidelines",

Section 16

17. IS: 13935-1993 "Repair and Seismic Strengthening of Buildings - Guidelines"

Section 17

61. Housing Schemes.

Section 61

62. Semi-detached and row housing.

Section 62

63. Shop-cum-residence.

Section 63

64. Cinema, Multiplex and Theatre building.

Section 64

65. Liquefied Petroleum Gas.

Section 65

66. Petrol Pump.

Section 66

67. Farm House.

Section 67

68. Application.

Section 68

69. Use in relation to Development Plans.

Section 69

70. Size of the plot and road width.

Section 70

71. Area for development.

Section 71

72. Park and Open Spaces.

Section 72

73. Community facilities.

Section 73

74. Exemptions.

Section 74

75. Submission of layout plan.

Section 75

76. Incentive for solar heating & lighting and waste water recycling.

Section 76

77. Restriction on Compounding.

Section 77

78. Compounding Rate.

Section 78

79. Compounding amount.

Section 79

80. System for monitoring.

Section 80

81. Telecom Tower Permission.

Section 81

82. E-Governance.

Section 82

84. Repeal and Savings.

Section 84

85. Interim Development Plan.

Section 85

86. Applicability of National Building Code.

Section 86

87. Prior Commitments.

Section 87

88. Decision of the Government to be final.

Section 88

89. Relaxation and modification by the Government.

Section 89

1. Provide Design Basis Report as per the document

Section 1

2. Provide description of Sub-structure and Super structure as per the format given in the Ref(5&6) enclosed.

Section 2

3. Provide brief Description of Structural System with sketches, images of drawing. etc. with specific focus on Lateral load resisting system'.

Section 3

4. Provide brief note on modeling, software used etc. Clear mention whether infill/partition wall is idealized as part of lateral load system?

Section 4

5. Provide the height of building in meters.

Section 5

6. Provide plan dimensions of the building (mt x mt)

Section 6

7. Provide following EQ loading details.

Section 7

8. Provide following data regarding Vertical Elements.

Section 8

9. Provide following data from Dynamic Analysis

Section 9

10. Provide, if applicable, following data for eachcantilever.

Section 10

11. Provide stability calculations for uplift and overturning(model extract in case of model)

Section 11

12. Typical design calculations for footings

Section 12

13. Typical design calculations for RCC columns Composite Columns

Section 13

14. Typical design calculations for RCC walls

Section 14

15. Typical design calculations for RC beams (Or Steel Beams)

Section 15

16. Typical design calculations for RCC Girders (Or Steel Girders/Truss)

Section 16

17. Typical design calculations for Steel Bracings

Section 17

18. Provide a note on special provisions suggested for the building (like dampers etc.)

Section 18

19. Soft copy of model including input and output.

Section 19

1. Number of floors

Section 1

3. Building Line, if any

Section 3

5. Abutting road width

Section 5

6. FAR

Section 6

7. Coverage percentage

Section 7

8. Tree Cover

Section 8

9. Water harvesting structures

Section 9

10. Land if required to be surrendered

Section 10

11. Lift/s, water pumps and storage tanks

Section 11

12. Internal roads/paving

Section 12

13. Parking areas and external lighting

Section 13

14. Lightening arrestors

Section 14

15. Fire Fighting installations

Section 15

16. Lifts

Section 16

17. Water pump

Section 17

18. Drainage and arrangement for waste water and sewage disposal

Section 18

19. Copy of agreement with the apartment Owners' Association/Society

Section 19

20. Implementation of Life Safety provisions as mentioned in National Building Code 2005(Group-I Part-W Fire and Life Safety-4)

Section 20

1. Construction Drawings

Section 1

2. Proper safety precautions taken

Section 2

3. Precautions taken for dewatering

Section 3

4. Dumping ground established

Section 4

5. Intermediate levels checked

Section 5

1. Characteristics of excavated strata

Section 1

2. Appropriate shoring and

Section 2

3. Final excavation levels, surface

Section 3

4. Anti-Termite Treatment has been done post excavation

Section 4

1. All levels and dimensions checked for correctness

Section 1

2. Shuttering is as per plan and has no gaps in between

Section 2

3. All materials are of specified brand and grade

Section 3

1. Mixing of concrete has been done as specified

Section 1

2. Slump and other tests carried out as specified

Section 2

3. Slump and other tests carried out as specified

Section 3

4. Required number of Samples have been taken for carrying out slump tests, cube tests etc

Section 4

1. Filling material/earth is as per specification

Section 1

1. All specified materials available at site

Section 1

1. Availability/Arrangement of pumps etc. proper access & walkway checked

Section 1

1. Four/Eight sets of the building plan:

Section 1

2. Ownership document:

Section 2

3. Supervision Certificate in form-V:

Section 3

4. Affidavit or peaceful possession of the land:

Section 4

6. NOC from lease case of lease hold:

Section 6

7. NOC from Fire Authority:

Section 7

8. NOC from Airport Authority:

Section 8

9. Environmental clearance:

Section 9

10. Details Fee :

Section 10

12. Any other certificate/NOC(please specify):

Section 12

1. Four/Eight sets of the building plan:

Section 1

2. Ownership document:

Section 2

3. Supervision Certificate in form-V:

Section 3

4. Affidavit or peaceful possession of the land:

Section 4

6. NOC from lease case of lease hold:

Section 6

7. NOC from Fire Authority:

Section 7

8. NOC from Airport Authority:

Section 8

9. Environmental clearance:

Section 9

10. Details Fee :

Section 10

12. Any other certificate/NOC(please specify):

Section 12
part 6

1. That the building has been constructed according to the structural design and specification prepared by me, which incorporates the provisions of structural safety norms as specified in part 6 (Structural Design) of the national building code of India, 2005 and other relevant codes and the design complies with the Earthquake safety requirement.

Section 1

2. That the construction has been done under my supervision and guidance and adheres to the structural drawings and specifications prepared by me and records of supervision have been maintained.

Section 2

1. Name .....................................................................................

Section 1

2. Father's/Husband's Name ...................................................................................

Section 2

3. Date of Birth ..............................................................................

Section 3

4. Nationality ...............................................................................

Section 4

5. Educational Qualification .............................................................

Section 5

6. Professional Experience ...................................................................

Section 6

7. Registration No. With Council of Architecture, New Delhi ..................................

Section 7

8. Registration with other relevant Institutions/ULBs .........................................

Section 8

9. Details of other Academic & Professional Achievements .......................................

Section 9

10. Details of Certificate relating to qualifications/testimonials, if any as per column 5 & 6 with self attested copies .........................................................

Section 10

11. Details of Bank Draft/Postal Order (separately for empanelment Rs. 500/ ............................

Section 11

12. Permanent Address - ..........................................................................

Section 12

13. Address for Correspondence - ...................................................................

Section 13

14. Tel. No./Mob. No - ..........................................................................

Section 14

15. Email id - ..................................................................................

Section 15

2. Type of Firm-(Partnership/Company) (In block letters)

Section 2

3. Name of Partner/Directors ....................................................

Section 3

4. Father's/Husband's Name ...............................................................

Section 4

5. Date of Birth ....................................................

Section 5

6. Nationality .........................................................................

Section 6

7. Registration No .............................................................

Section 7

8. PAN/DIN .......................................................................

Section 8

9. Sales Tax No ...............................................................

Section 9

10. VAT No .....................................................................

Section 10

11. Income Tax Statement of Last Three consecutive Financial Year ..........................................................................

Section 11

12. Category applied for .......................................................

Section 12

13. Details of fee ...........................................................

Section 13

14. Permanent Address ..........................................................

Section 14

15. Address for Correspondence - ................................................................................

Section 15

16. Tel. No./Mob. No .............................................................................

Section 16

17. Email id ................................................................

Section 17

1. That in consideration of the sanction of the plans by .................................................... Authority for construction of the basement the executant undertakes that he/she shall at all times keep .................................................... Authority free from any liability, loss or damages/flowing from any injury or damage caused to the adjoining built up properties or to any person as a consequence of the construction of at the time of digging of its foundations or du

Section 1

2. The owner agreed and undertakes that in the event of any claim being made by any person or persons against the concerned Authority either in respect of the sanction granted by the concerned Authority to the owner for the construction of basement or in respect of the construction or manner of construct ion of the basement .by the owner of the consequences flowing from the said sanction the executant shall be responsible and liable and not .................................................... Au

Section 2

3. The executant agrees and undertake to indemnify the concerned Authority fully in respect of any amount which the concerned Authority may be required to pay to any person either by way of compensation or on any other account as a result of any claim or suit or any other proceedings concerning the sanctioning of the construction of the basement of the making there of and also in respect of the costs and expenses which the concerned Authority may incur on defending any action.

Section 3

4. Without prejudice to the above undertaking the executant hereby binds itself to pay to .................................................... Authority to the full extent any amount which .................................................... Authority may be required to pay to any person in connection with relating to or concerning the sanctioning or the basement o the making thereof.

Section 4

5. The owner agrees and undertakes that this bond shall remain in full force and effect till the executant faithfully observes/performs the undertaking here in before contained. In witness where of the executant above named has signed this bond on this .................................................... of .................................................... at .................................................... day

Section 5

1. Name ..............................................

Section 1

2. Name ..................................................

Section 2

1. That I am the Owner/Power of Attorney Holder of land having R.S./M.S. Plot No. ........................................................................... khata No. ........................................................................... Khewat No. ........................................................................... Thana No. ........................................................................... corresponding to holding No. ......................................................

Section 1

2. That the land mentioned above is a freehold property and does not belong to Khas Mahal Estate of Government. It is not either Gair Mazarua Aam Khas, Kaisare Hind, District Board or Acquired Land.

Section 2

3. That the land stated above is a tribal land/not a tribal land for tribal land; permission for transfer has been obtained vide Case No. Year from SAR/DC/Commissioner Court.

Section 3

4. That I have applied a building Plan vide B.C. Case No.................................

Section 4

5. That further declare that in future, if it will be found that property mentioned above are Gair Mazarua Aam Khas, Kaisare Hind, District Board or Acquired Land property of Government the sanctioned map will be deemed to be cancelled due to misrepresentation and suppression of facts.

Section 5

1. Certified that the building plans submitted for approval will satisfy the safety requirements as stipulated under Building Bye-laws 59 and the information given there in is factually correct to the best of our knowledge and understanding .

Section 1

2. It also certified that the structural design including safety from hazards based on soil conditions shall be duly incorporated in the design of the building and these provisions shall be adhered to during the construction as per Annexure-IX & X.

Section 2