40.1.1 The maximum height of a building shall in no case exceed (1.5 times the width of the road on which the plot abuts) + Road widening + the front setback.
40.1.2 If a building abuts on two or more streets of different widths, the building shall be deemed to face upon the street that has the greater width and the height of the building shall be regulated by the width of that street.
Table- 17 Height restriction with respect to approach funnels
Table- 17 Height restriction with respect to approach funnels
Distance from nearest runway end (In metres)
Maximum Permissible height above the elevation of
the nearest runway end
Up to 360
0
631 to 510
6
511 to 660
9
661 to 810
12
811 to 960
15
961 to 1110
18
1111 to 1260
21
1261 to 1410
24
1411 to 1560
27
More than 1560
30
Table -18: Height restriction with respect to transitional area
Table -18: Height restriction with respect to transitional area
Distance of the Inner Boundary of the
Transitional Area (Outer Boundary of the Air Port) [Metres]
Maximum Permissible height above the elevation of
the airport reference point [metres]
Up to 21
0
22 to 42
3
43 to 63
6
64 to 84
9
85 to 105
12
106 to 126
15
127 to 147
18
148 to 168
21
169 to 189
24
190 to 210
27
More than 210 M
30
Section 40 • Jharkhand Building Byelaws 2016
40. Height of a building.
jharkhand-building-byelaws-2016-sec-40.json
•
Section 40
{
"act_title": "Jharkhand Building Byelaws 2016",
"act_slug": "jharkhand-building-byelaws-2016",
"section_label": "Section",
"section": {
"number": "40",
"title": "40. Height of a building.",
"chapter": null,
"content": "40.1.1 The maximum height of a building shall in no case exceed (1.5 times the width of the road on which the plot abuts) + Road widening + the front setback.\n40.1.2 If a building abuts on two or more streets of different widths, the building shall be deemed to face upon the street that has the greater width and the height of the building shall be regulated by the width of that street.\nTable- 17 Height restriction with respect to approach funnels\nTable- 17 Height restriction with respect to approach funnels\nDistance from nearest runway end (In metres)\nMaximum Permissible height above the elevation of\n\t\t\t\tthe nearest runway end\nUp to 360\n0\n631 to 510\n6\n511 to 660\n9\n661 to 810\n12\n811 to 960\n15\n961 to 1110\n18\n1111 to 1260\n21\n1261 to 1410\n24\n1411 to 1560\n27\nMore than 1560\n30\nTable -18: Height restriction with respect to transitional area\nTable -18: Height restriction with respect to transitional area\nDistance of the Inner Boundary of the\n\t\t\t\tTransitional Area (Outer Boundary of the Air Port) [Metres]\nMaximum Permissible height above the elevation of\n\t\t\t\tthe airport reference point [metres]\nUp to 21\n0\n22 to 42\n3\n43 to 63\n6\n64 to 84\n9\n85 to 105\n12\n106 to 126\n15\n127 to 147\n18\n148 to 168\n21\n169 to 189\n24\n190 to 210\n27\nMore than 210 M\n30",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
"prev_section": "39",
"next_section": "41"
}