← Back to Jharkhand Building Byelaws 2016

36. Minimum setbacks & Height for non-high rise buildings.

Table - 8: Minimum Front and Rear setbacks and height of residential buildings
Table - 8: Minimum Front and Rear setbacks and height of residential buildings
Sl.
Sl.
Average Depth of plot (In meters)
Average Depth of plot (In meters)
Building Height Upto G+2 Maximum-10m
Building Height Upto G+2 Maximum-10m
Building Height Upto G+3 Maximum-13.3m
Building Height Upto G+3 Maximum-13.3m
Building Height Upto G+4 Maximum-16.4m
Building Height Upto G+4 Maximum-16.4m
Minimum Front set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Rear set back (m)
Minimum Front set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Rear set back (m)
Minimum Front set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Rear set back (m)
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
(viii)
1
Upto 10m
1.5
0.90
No construction shall be permitted
No construction shall be permitted
2
Exceeding 10m & upto 15m
2.0
1.5
3.0
1.5
No construction shall be permitted
3
Exceeding 15m & upto 21m
2.5
1.5
3.0
1.8
3.0
3.0
4
Exceeding 21m & upto 27m
3.0
1.8
3.0
2.0
3.5
3.0
5
Exceeding 27m & upto 33m
4.0
2.5
4.0
3.0
4.0
3.5
6
Exceeding 33m & upto 39m
4.0
3.0
4.5
4.0
4.5
4.0
7
Exceeding 39m & upto 45m
4.0
4.0
4.5
4.0
5.0
4.5
8
More the 45m
4.0
4.0
5.0
5.0
6.0
5.0
Table 9. Minimum Side setbacks for residential buildings
Table 9. Minimum Side setbacks for residential buildings
Sl.
Sl.
Average Width of plot (in meters)
Average Width of plot (in meters)
Building Height Upto G+2 Maxmimum-10m
Building Height Upto G+2 Maxmimum-10m
Building Height G+3 Upto Maxmimum-13.3m
Building Height G+3 Upto Maxmimum-13.3m
Building Height Upto G+4 Maximum-16.4m
Building Height Upto G+4 Maximum-16.4m
(i)
(i)
(ii)
(ii)
(iii)
(iii)
(iv)
(iv)
(v)
(v)
(vi)
(vi)
(vii)
(vii)
(viii)
(viii)
1
Upto 10m
At least one side from 0.90 m.
No construction shall be permitted
No construction shall be permitted
2
Exceeding 10m & upto 15m
0.90
0.90
0.90
0.90
No construction shall be permitted
3
Exceeding 15m & upto 21m
1.0
1.0
1.5
1.5
2.0
2.0
4
Exceeding 21 m & upto 27m
1.5
1.5
2.0
2.0
2.5
2.5
5
Exceeding 27m & upto 33m
1.5
1.5
2.5
2.5
3.0
3.0
6
Exceeding 33m & upto 39m
2.0
2.0
3.0
3.0
3.66
3.66
7
Exceeding 39m & upto 45m
3.0
3.0
3.66
3.66
4.50
4.50
8
More the 45m
3.66
3.66
4.00
4.00
5.00
5.00
Table 10. Minimum front and rear setback for commercial/mercantile buildings
Table 10. Minimum front and rear setback for commercial/mercantile buildings
Sl.
Sl.
Average Depth of plot (In meters)
Average Depth of plot (In meters)
Building Height up to 16.4 m
Building Height up to 16.4 m
Minimum Front set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Rear set back (m)
(i)
(i)
(ii)
(ii)
(iii)
(iii)
(iv)
(iv)
1
Upto 10m
No construction is allowed
2
Exceeding 10m & upto 15m
4.5
3.0
3
Exceeding 15m & upto 21m
5.5
4.0
4
Exceeding 2Im & upto 27m
6.0
4.0
5
Exceeding 27m & upto 33m
6.5
4.0
6
Exceeding 33m & upto 39m
7.0
4.5
7
Exceeding 39m & upto 45m
7.5
4.5
8
More than 45m
8.0
5.0
Table 11. Minimum side setbacks for commercial/mercantile buildings
Table 11. Minimum side setbacks for commercial/mercantile buildings
Sl.
Sl.
Average width of plot (In meters)
Average width of plot (In meters)
Building Hei ht up to16.4m
Building Hei ht up to16.4m
Minimum Left set back (m)
Minimum Left set back (m)
Minimum Right set back (m)
Minimum Right set back (m)
(i)
(i)
(ii)
(ii)
(iii)
(iii)
(iv)
(iv)
1
Upto 10m
At least one side 1.5 m.
2
Exceeding 10m & upto 15m
2.0
2.0
3
Exceeding 15m & upto 2Im
2.5
2.5
4
Exceeding 21m & upto 27m
3.0
3.0
5
Exceeding 27m & upto 33m
4.0
4.0
6
Exceeding 33m & upto 39m
4.0
4.0
7
Exceeding 39m & upto 45m
5.0
5.0
8
More than 45m
5.5
5.5
Table 12. Open spaces around industrial buildings
Table 12. Open spaces around industrial buildings
Sl.
Sl.
Plot Size
Plot Size
Minimum Front set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Rear set back (m)
Minimum Sides set back (m)
Minimum Sides set back (m)
(i)
(ii)
(iii)
(iv)
(v)
1
550 sqm to 1000 sqm
9.0
4.5
4.5
2
1000 sqm to 5000 sqm
10.0
6.0
6.0
3
5000 sqm to 30000 sqm
12.0
9.0
9.0
4
Above 30000 sqm
15.0
12.0
10.0
Table 13. Minimum set back for industrial building constructed over plot size upto 550 sqm.
Table 13. Minimum set back for industrial building constructed over plot size upto 550 sqm.
Sl.
Sl.
Width of Plot
Width of Plot
Minimum Front set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Rear set back (m)
Minimum Sides set back (m)
Minimum Sides set back (m)
(i)
(i)
(ii)
(ii)
(iii)
(iii)
(iv)
(iv)
(v)
(v)
1
Upto 10 mtrs.
3.0
3.0
1.5
2
Exceeding 10m & upto 12m
4.0
3.0
2.0
3
Exceeding 12m & upto 15m
5.0
3.0
3.0
4
Exceeding 15m & upto 18m
6.0
4.0
4.0
5
Exceeding 18m
6.0
4.5
4.5