    "act_title": "Jharkhand Building Byelaws 2016",
    "act_slug": "jharkhand-building-byelaws-2016",
    "section_label": "Section",
    "section": {
        "number": "36",
        "title": "36. Minimum setbacks & Height for non-high rise buildings.",
        "chapter": null,
        "content": "Table - 8: Minimum Front and Rear setbacks and height of residential buildings\nTable - 8: Minimum Front and Rear setbacks and height of residential buildings\nSl.\nSl.\nAverage Depth of plot (In meters)\nAverage Depth of plot (In meters)\nBuilding Height Upto G+2 Maximum-10m\nBuilding Height Upto G+2 Maximum-10m\nBuilding Height Upto G+3 Maximum-13.3m\nBuilding Height Upto G+3 Maximum-13.3m\nBuilding Height Upto G+4 Maximum-16.4m\nBuilding Height Upto G+4 Maximum-16.4m\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\n(vi)\n(vii)\n(viii)\n1\nUpto 10m\n1.5\n0.90\nNo construction shall be permitted\nNo construction shall be permitted\n2\nExceeding 10m & upto 15m\n2.0\n1.5\n3.0\n1.5\nNo construction shall be permitted\n3\nExceeding 15m & upto 21m\n2.5\n1.5\n3.0\n1.8\n3.0\n3.0\n4\nExceeding 21m & upto 27m\n3.0\n1.8\n3.0\n2.0\n3.5\n3.0\n5\nExceeding 27m & upto 33m\n4.0\n2.5\n4.0\n3.0\n4.0\n3.5\n6\nExceeding 33m & upto 39m\n4.0\n3.0\n4.5\n4.0\n4.5\n4.0\n7\nExceeding 39m & upto 45m\n4.0\n4.0\n4.5\n4.0\n5.0\n4.5\n8\nMore the 45m\n4.0\n4.0\n5.0\n5.0\n6.0\n5.0\nTable 9. Minimum Side setbacks for residential buildings\nTable 9. Minimum Side setbacks for residential buildings\nSl.\nSl.\nAverage Width of plot (in meters)\nAverage Width of plot (in meters)\nBuilding Height Upto G+2 Maxmimum-10m\nBuilding Height Upto G+2 Maxmimum-10m\nBuilding Height G+3 Upto Maxmimum-13.3m\nBuilding Height G+3 Upto Maxmimum-13.3m\nBuilding Height Upto G+4 Maximum-16.4m\nBuilding Height Upto G+4 Maximum-16.4m\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n(iv)\n(iv)\n(v)\n(v)\n(vi)\n(vi)\n(vii)\n(vii)\n(viii)\n(viii)\n1\nUpto 10m\nAt least one side from 0.90 m.\nNo construction shall be permitted\nNo construction shall be permitted\n2\nExceeding 10m & upto 15m\n0.90\n0.90\n0.90\n0.90\nNo construction shall be permitted\n3\nExceeding 15m & upto 21m\n1.0\n1.0\n1.5\n1.5\n2.0\n2.0\n4\nExceeding 21 m & upto 27m\n1.5\n1.5\n2.0\n2.0\n2.5\n2.5\n5\nExceeding 27m & upto 33m\n1.5\n1.5\n2.5\n2.5\n3.0\n3.0\n6\nExceeding 33m & upto 39m\n2.0\n2.0\n3.0\n3.0\n3.66\n3.66\n7\nExceeding 39m & upto 45m\n3.0\n3.0\n3.66\n3.66\n4.50\n4.50\n8\nMore the 45m\n3.66\n3.66\n4.00\n4.00\n5.00\n5.00\nTable 10. Minimum front and rear setback for commercial/mercantile buildings\nTable 10. Minimum front and rear setback for commercial/mercantile buildings\nSl.\nSl.\nAverage Depth of plot (In meters)\nAverage Depth of plot (In meters)\nBuilding Height up to 16.4 m\nBuilding Height up to 16.4 m\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n(iv)\n(iv)\n1\nUpto 10m\nNo construction is allowed\n2\nExceeding 10m & upto 15m\n4.5\n3.0\n3\nExceeding 15m & upto 21m\n5.5\n4.0\n4\nExceeding 2Im & upto 27m\n6.0\n4.0\n5\nExceeding 27m & upto 33m\n6.5\n4.0\n6\nExceeding 33m & upto 39m\n7.0\n4.5\n7\nExceeding 39m & upto 45m\n7.5\n4.5\n8\nMore than 45m\n8.0\n5.0\nTable 11. Minimum side setbacks for commercial/mercantile buildings\nTable 11. Minimum side setbacks for commercial/mercantile buildings\nSl.\nSl.\nAverage width of plot (In meters)\nAverage width of plot (In meters)\nBuilding Hei ht up to16.4m\nBuilding Hei ht up to16.4m\nMinimum Left set back (m)\nMinimum Left set back (m)\nMinimum Right set back (m)\nMinimum Right set back (m)\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n(iv)\n(iv)\n1\nUpto 10m\nAt least one side 1.5 m.\n2\nExceeding 10m & upto 15m\n2.0\n2.0\n3\nExceeding 15m & upto 2Im\n2.5\n2.5\n4\nExceeding 21m & upto 27m\n3.0\n3.0\n5\nExceeding 27m & upto 33m\n4.0\n4.0\n6\nExceeding 33m & upto 39m\n4.0\n4.0\n7\nExceeding 39m & upto 45m\n5.0\n5.0\n8\nMore than 45m\n5.5\n5.5\nTable 12. Open spaces around industrial buildings\nTable 12. Open spaces around industrial buildings\nSl.\nSl.\nPlot Size\nPlot Size\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\nMinimum Sides set back (m)\nMinimum Sides set back (m)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\n1\n550 sqm to 1000 sqm\n9.0\n4.5\n4.5\n2\n1000 sqm to 5000 sqm\n10.0\n6.0\n6.0\n3\n5000 sqm to 30000 sqm\n12.0\n9.0\n9.0\n4\nAbove 30000 sqm\n15.0\n12.0\n10.0\nTable 13. Minimum set back for industrial building constructed over plot size upto 550 sqm.\nTable 13. Minimum set back for industrial building constructed over plot size upto 550 sqm.\nSl.\nSl.\nWidth of Plot\nWidth of Plot\nMinimum Front set back (m)\nMinimum Front set back (m)\nMinimum Rear set back (m)\nMinimum Rear set back (m)\nMinimum Sides set back (m)\nMinimum Sides set back (m)\n(i)\n(i)\n(ii)\n(ii)\n(iii)\n(iii)\n(iv)\n(iv)\n(v)\n(v)\n1\nUpto 10 mtrs.\n3.0\n3.0\n1.5\n2\nExceeding 10m & upto 12m\n4.0\n3.0\n2.0\n3\nExceeding 12m & upto 15m\n5.0\n3.0\n3.0\n4\nExceeding 15m & upto 18m\n6.0\n4.0\n4.0\n5\nExceeding 18m\n6.0\n4.5\n4.5",
        "footnote": "",
        "is_definition": false,
        "sort_order": 37
    },
    "prev_section": "35",
    "next_section": "37"
}