The M.P. Bhumi Vikas Rules, 1984
The M.P. Bhumi Vikas Rules, 1984
Sections
1. Short title.
Section 12. Definitions.
Section 23. Applicability of the rules.
Section 34. Rules not to apply to operational construction of the Government.
Section 45. Existing Building.
Section 56. Alternative materials, methods of design and construction and tests.
Section 67. Department of building inspection.
Section 78. Power and duties of the building officer.
Section 89. Right of Entry.
Section 910. Inspection.
Section 1011. Constructions not according to Plan.
Section 1112. Occupancy Violations.
Section 1213. Board of Appeal.
Section 1314. Permission for Development or for Construction.
Section 1415. Development/Building permit issued prior to these Rules.
Section 1518. Preparation and signing of plans.
Section 1819. Notice for alteration only.
Section 1920. Notice for land adjoining the Government property.
Section 2021. Fees.
Section 2122. Withdrawal of application.
Section 2225. Revocation of Permission.
Section 2526. Licensing of Architect/Engineer etc.
Section 2627. Grant of permission or refusal.
Section 2728. Limitation period for grant or refusal of permission.
Section 2829. Reasons to be given when permission refused.
Section 2930. Owner to resubmit plan complying with objections.
Section 3031. Responsibilities and duties of the owner.
Section 3133. Documents at site.
Section 3334. Inspection.
Section 3435. Demolition of Building.
Section 3536. Architectural control.
Section 3637. Land use classification and uses permitted-Land use Classification.
Section 3738. Industries permitted in R 1 , R 2 and commercial zones.
Section 3839. Means of access.
Section 3940. Levelling etc. of means of access.
Section 4041. Access from Highways/Important Roads.
Section 411. For building above 18 metres and upto 24 m. height-
Section 12. For building above 24 m. height-
Section 243. Cul-De-Sacs.
Section 4344. Alley.
Section 4445. Intersection of Roads.
Section 4546. Building Line.
Section 4647. Community Open Spaces and Amenities.
Section 4748. Industrial Zones.
Section 4849. Other Amenities.
Section 4950. Requirements of site.
Section 5051. Surface Water Drains.
Section 5152. Distance from Electric Lines.
Section 5253. Size of Plots.
Section 5354. Classification of Buildings.
Section 5455. General.
Section 5556. Residential Buildings-Exterior open spaces.
Section 5657. Open spaces for other occupancies.
Section 5758. Projections.
Section 5859. Limitation to open space.
Section 5960. Group housing.
Section 6061. Floor Area Ratio.
Section 611. Proposed buildings shall be constructed on 20,000 Square Feet of land.
Section 12. In case of old buildings, the Software Unit should have been in existence for more than one year.
Section 24. The above relaxation shall be given only in existing FAR stipulated in rules. The provisions in rules for Ground Coverage. M.O.S. and Height of building shall remain unchanged.]
Section 462. Height Limit.
Section 6263. Height exceptions-Roof Structures.
Section 6364. Planting of trees.
Section 6465. Plinth.
Section 6566. Habitable rooms.
Section 6667. Kitchen.
Section 6768. Bathroom and Water Closets.
Section 6869. Ledge or Tand/Loft.
Section 6970. Mezzanine (Entresol) Floor.
Section 7071. Store room.
Section 7172. Garage.
Section 7273. Basement.
Section 7374. Parapet.
Section 7475. Boundary Wall.
Section 7576. Septic Tanks.
Section 7677. Staircase.
Section 7778. Roofs.
Section 7879. Lighting and Ventilation of Rooms.
Section 7982. Exit Requirements.
Section 8285. Quality of Materials and Workmanship.
Section 8586. Building Services.
Section 8687. Plumbing Services.
Section 8788. Requirement of water supply in buildings.
Section 8889. Requirements of Sanitary fittings.
Section 8990. Cinemas, Theatres and Public Assemble Halls.
Section 9091. Factories and Industrial Structures-Provisions of the Factories Act, 1948 (No. LXIII of 1948) to apply.
Section 9192. Petrol filling stations.
Section 9293. Signs and outdoor display structure-Provisions of Code to apply.
Section 9394. Special requirements of Low-Income Housing Group.
Section 9497. Issue of Service Certificate.
Section 9798. Completion certificate.
Section 981. Key Plan
Section 12. Site Plans
Section 23. Sub-Division/Layout Plan
Section 34. Building Plans
Section 45. Services Plans
Section 57. Ownership Title.
Section 72. Condition of "not more than 5 workers at a time are employed" is not applicable for industries listed after number 40].
Section 21. General.
Section 12. Planning. - (1) Type of Development
Section 23. General Building Requirements.
Section 34. Roads and Pathways.
Section 45. Other Requirements
Section 56. Site and Services Schemes.
Section 6
the-m-p-bhumi-vikas-rules-1984.json
•
104 Sections
•
Madhya Pradesh
{
"id": 19014,
"slug": "the-m-p-bhumi-vikas-rules-1984",
"title": "The M.P. Bhumi Vikas Rules, 1984",
"short_title": "The M.P. Bhumi Vikas Rules, 1984",
"act_number": "Published vide Notification No. 2869-32-84, dated ",
"act_year": 1984,
"act_type": "STATE",
"location": "Madhya Pradesh",
"law_status": "unknown",
"enactment_date": null,
"description": "The M.P. Bhumi Vikas Rules, 1984",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "1. Short title.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "2",
"title": "2. Definitions.",
"chapter": null,
"content": "(1) \"Accessory use\" means any use of the premises subordinate to the principal use and customarily incidental to the principal use;\n(2) \"Act\" means the Madhya Pradesh Nagar Tatha Gram Nivesh Adhiniyam, 1973 (No. 23 of 1973);\n(3) \"Alteration\" means a change from one occupancy to another or a structural change, such as an addition to the area or height, or the removal of part of a building, or any change to the structure, such as the construction of, cutting into or removal of any wall, partition, column, beam, joint, floor or other support, or a change to or closing of any required means of ingress or egress or a change of the fixtures or equipment;\n(4) \"Approved\" means approved by the Authority having jurisdiction of power;\n(5) \"Authority having jurisdiction\" (hereinafter referred to in these rules as \"Authority\") in relation to building activities means-\n(a)\nfor permission for development of land in planning area.\nThe Director of Town and Country Planning or any other officer\n\t\t\t\tauthorised by him in this behalf.\n(b)\nfor permission for development of land in non-planning area or\n\t\t\t\tfor construction/alteration, demolition of building in any area,-\n(i)\nin any area falling within the local limits of a Municipal\n\t\t\t\tCorporation or Municipality and over which Special Area\n\t\t\t\tDevelopment Authority has no jurisdiction.\nSuch Municipal Corporation or Municipal Council, as the case\n\t\t\t\tmay be, or such other. authority or officer authorised by or\n\t\t\t\tunder the relevant Municipal Law to grant such permission.\n(ii)\nin any area over which a Special Area Development Authority\n\t\t\t\thas jurisdiction.\nSuch Special Area Development Authority or such officer of the\n\t\t\t\tauthority as may be authorised by such authority in this behalf.\n(iii)\nin any area over which any Development Authority other than\n\t\t\t\tSpecial Area Development Authority has exclusive jurisdiction.\nSuch Development Authority, or such other officer of the\n\t\t\t\tDevelopment Authority as may be authorised by such Authority in\n\t\t\t\tthis behalf.\nExplanation.\n(6) \"Balcony\" means a horizontal projection, including a handrail or balustrade, to serve as passage or a sitting out place;\n(7) \"Basement or Cellar\" means the lower storey of a building below or party below ground level;\n(8) \"Building Activities\" means-\n(a) erection, re-erection, making material alteration and demolition of any building:\n(b) development of land as a composite building scheme and corporate development;\n(c) development and redevelopment of any tract of land which includes division and sub-division into plots or various land uses within a colony.\n[(9) \"Height of a Building\" means the vertical distance of the building which shall be measured from a reference level which would be either the center of the approach road from which the access is being taken or the average height of the plot above this level, whichever is higher. This level shall be construed as the ground level and the vertical distance of the structure shall be calculated from such level to the top of the slab of the topmost floor. Space below this level shall be considered as basement. In case of pitched/sloping roofs, the midpoint between the roof ridge and the eaves level shall be taken as the highest point and the vertical distance from the construed ground level, measured upto this point. If the built from below the road level is used as habitable accommodation because of the advantage of existing topography such area shall be permitted as habitable area and shall be counted in the Floor Area Ratio, Machine rooms, mumptee, lift, AC structure and water storage tank of topmost floor shall be exempted from the calculation of vertical distance.]\n(10) \"Building line\" means the line up to which the plinth of a building adjoining a street or an extension of a street or a strip of land earmarked or reserved for future construction of street may lawfully extend. It includes the lines prescribed, if any, in any scheme. The building line may change from time to time as decided by the Authority;\n(11) \"Chajja\" means a sloping or horizontal structural overhang usually provided over opening on external walls to provide protection from sun and rain and includes architectural extension;\n(12) \"Chimney\" means an upright shaft containing and encasing one or more flues provided for the conveyance to the outer air of any product of combustion resulting from the operation of any heat producing appliances or equipment, employing solid, liquid or gaseous fuel;\n(13) \"Chowk or Courtyard\" means a space permanently open to the sky, enclosed fully or partially by building and may be at ground level or any other level within or adjacent to a building;\n(14) \"Chowk, Inner\" means a Chowk enclosed on all sides;\n(15) \"Chowk Outer\" means as Chowk where one of its sides is not enclosed;\n(16) \"Code\" means the National Building Code of India as published by the Indian Standards Institution;\n(17) \"Conversion\" means the change of occupancy or premises to any occupancy or use requiring additional occupancy permit;\n(18) \"Corporation\" means a Corporation established under the Madhya Pradesh Municipal Corporation Act, 1956 (No. 23 of 1956);\n[(19) \"Covered Area\" means the area of the land covered by the the building at the ground floor level and shall be counted as the ground coverage. This shall exclude the area covered by projections at slab level and area of the plinth not covered by roof at top. Cantilevered projections up to an extend of one third of the Marginal open space shall be permissible on the upper slab level with a clear height for vehicular/pedestrian movement. These projections cannot be made at height below 2.5 meter from the ground level. This projection shall not construe to be covered area. Area covered on the second and third floor levels as cantilever projection with at least 5.5 meter clear space below for movement, but not within the setback/marginal open space, shall not be counted in covered area. All areas in the building shall be counted in covered areas except for service ducts, garrage on ground floor and lift wells;]\n(20) \"Cut de Sac\" means a lane, one end of which terminates providing n,o further access;\n(21) \"Density\" means the residential density as expressed in these rules in terms of number of dwelling units per hectare.\nExplanation.\n(ii) Incidental open spaces are mainly open spaces required by these rules to be left around and in between two buildings to provide lighting and ventilation;\n(22) \"Development Authority\" means a Town and Country Development Authority established under Section 38 of the Madhya Pradesh Nagar Tatha Gram Nivesh Adhiniyam, 1973 (No. 23 of 1973) or a Special Area Development Authority constituted under Section 65 of the said Act or an Improvement Trust constituted under the Madhya Pradesh Town Improvement Trust Act, 1960 (No. 14 of 1961):\n(23) \"Drain\" means a line of pipes including all fittings and equipments, such as manholes, inspection chambers, traps, gullies and floor traps used for the drainage of a building, or a number of buildings, or yards, appurtenant to buildings, within the same curtilage, and shall include open channels used for carrying surface water;\n(24) \"Drainage\" means the removal of any liquid by a system constructed for this purpose;\n(25) \"Dwelling Unit/Tenement\" means an independent dwelling unit with separate facilities for living, cooking and sanitary requirement;\n(26) \"Exit\" means a passage, channel or means of egress from any building, storeys or floor area to a street or other open space of safety;\n(27) \"Fire Separation\" means the distance in metres measured from any other building on the site, or from other site, or from the opposite side of a street or other public space to the building;\n[(27-a) \"Forest House\" means a house in such areas and built subject to such conditions as specified in sub-rule (13) of Rule 17.]\n(28) \"Floor\" means the lower surface in a storey on which one normally walks in a building. The general term, \"floor\" unless otherwise specifically mentioned shall not refer to a 'Mezzanine Floor'.\n[(28-a) \"High rise building\" means a building-\n(i) which consists of more than six storeys; or\n(ii) which has a height of more than 18 metres;\" (exclusive of stilt parking of 2.4 m. height] .\n[(29) \"Floor Area Ratio\" means the ratio of the permissible total of built up area in a building on all floors to the total plot area of the land in question. (The ratio stipulates the maximum of built quantity and no variations or exceptions shall be allowed, except as specifically provided. The built up area as stated would construe the total built up area on all floors with the exception of lift wells, service ducts, machine room for lifts, water tanks, covered parking area, one entrance lobby/foyer on ground floor, corridors, arcades mumptee, staircases, but inclusive of covered projection exceeding the limits prescribed under Rule 58.]\n(30) \"Foundation\" means a part of structure which is in direct contact with, and transmits loads to the ground;\n(31) \"Private garage\" means a building whether permanent or temporary or a portion thereof designed and used for parking of private y owned mechanically propelled motor vehicles (of any description or other vehicles, in either case in private ownership);\n(32) \"Public garage\" means a building or portion thereof, other than a private garage, designed or used for repairing, servicing, hiring, selling or storing or parking of motor vehicles of any description or other vehicles;\n[(33) \"Group Housing\" means housing of a number of dwelling units on an undivided plot of land, built compositely and integrally where land building and services are held under a level right jointly, buildings and services are maintained jointly and the construction is undertaken by one Agency/Authority/Individual.]\n(34) \"Habitable room\" means a room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is used as a living room, but not including bathrooms, water closet compartments, laundries, serving and storage pantries, corridors, attics and spaces that are not used frequently or during extended periods;\n(35) \"Ledge or tand\" means a shelf like projection, supported in any manner whatsoever, except by means or vertical supports within a room itself but not having projection wider than one metre.\n(36) \"Licensed Architect/Structural Engineer/Engineer/Town Planner Supervisor Group\" means respectively a qualified architect, Structural Engineer/Engineer/Town planner/Supervisor/group who, in each case, has been licensed as such under these rules by the Authority;\n(37) \"Lift\" means an appliance designed to transport persons or materials between two or more levels in a vertical or substantially vertical direction by means of a guided car platform;\n(38) \"Loft\" means an intermediary floor between two floors or a residual space in a pitched roof, above normal floor level which is constructed or adopted for storage purposes;\n(39) \"Mezzanine Floor\" means an intermediate floor, between two floors above ground level;\n(40) \"Municipal Council\" means the Council constituted under the Madhya Pradesh Municipalities Act, 1961 (No. 37 of 1961);\n(41) \"Occupancy or Use Croup\" means the principal occupancy for which a building or a part of a building is used or intended to be used, for the purposes of classification of a building according to occupancy, an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it.\nExplanation.\n(i) \"Residential Buildings\" include any building in which sleeping accommodation is provided for normal residential purposes with or without cooking or dining or both facilities. It includes one or two or multi-family dwellings, lodging or rooming houses, dormitories, apartment houses and flats and residential hotels;\n(ii) \"Educational Buildings\" include any building used for school, college or day-care purposes for more than eight hours per week involving assembly for instruction, education or recreation incidental to educational buildings;\n(iii) \"Institutional Building\" include any building or part thereof which is used for purposes such as medical or other treatment or care of persons suffering from physical or mental illness, disease or infirmity, care of infants, convalescents or aged persons and for penal or correctional detention in which the liberty of the inmates is restricted. Institutional buildings ordinarily provide sleeping accommodation for the occupants. It includes hospitals, sanitoria, custodial institutions and penal institutions like jails, prisons, mental hospitals and reformatories;\n(iv) \"Assembly Building\" include any building or part of a building where groups of people congregate or gather for amusement recreation, social, religious, patriotic, civil, travel and similar purposes; for example theatres, motion picture houses, assembly halls, auditoria, exhibition halls, museums, skating rinks, gymnasium, restaurants, place of worship, dance halls, club rooms, passenger stations, and terminals of air, surface and other public transportation services, recreation piers and stadia;\n(v) \"Business building\" means any building or part of a building which is used for transaction of business for the keeping of accounts and records for similar purposes and include doctor's service facilities, city halls, town halls, Court houses, record and references libraries, where principal function of these is transaction of public business and the keeping of books and records;\n(vi) \"Mercantile building\" means any building or part of a building which is used as shops, stores, markets, for display and sale of merchandise either wholesale or retail Office storage and service facilities incidental to the sale of merchandise and located in the same building shall be included under this group; .\n(vii) \"Industrial Building\" means any building or part of a building or structure, in which products or materials of all kinds and properties are fabricated, assembled or processed and include assembly plants, laboratories, power plants, smoke houses, refineries, gas plants, mills, dairies, factories;\n(viii) \"Storage Building\" means any building or part of a building used primarily for the storage or sheltering of goods, wares or merchandise and include ware houses, cold storage,, freight depots, transit sheds, store houses, public garages hangers, truck terminals, grain elevators, barns and stables;\n(ix) \"Hazardous building\" means any building or part of a building which is used for the storage, handling, manufacture or processing of highly combustible or explosive materials or products which are liable to burn with extreme rapidity and/or which may produce poisonous fumes or explosions, for the storage, handling, manufacturing or processing whereof involve highly corrosive, toxic or noxious alkalies acids or other liquids or chemicals producing flame, fumes and explosive, poisonous, irritant or corrosive gases; and tor the storage, handling or processing of any material producing explosive mixtures of dust or which result in the division of matter into fine particles subject to spontaneous ignition;\n(42) \"Occupier\" includes any person for the time being/paying or liable to pay rent or any portion of the building in respect of which the ward is used, or compensation or premium on account of occupation of such building and also a rent-free tenant but doe not include a lodger, and the words 'occupy' and occupation shall be construed accordingly;\n(43) \"Open space\" means an area forming an integral part of the plot left open to the sky;\n(44) \"Front open space\" means an open space across the front of a plot between the building line and the front boundary of the plot;\n(45) \"Rear open space\" means an open space across the rear of a plot between the rear of the building and the rear boundary of the plot,\n(46) \"Side open space\" means an open space across the side of the plot between the side of the building and the side boundary of the plot,\n(47) \"Operational Construction\" means a construction put up by Government Department for operational purposes;\n(48) \"Owner\" means the person who has legal title for land or building and also includes :-\n(a) an agent or trustee who receives the rent on behalf of the owner;\n(b) an agent or trustee who receives the rent of or is entrusted with or is concerned with any building devoted to religious or charitable purposes;\n(c) a receiver, executor or administrator or a manager appointed by any Court of competent jurisdiction to have the charge of or to exercise the rights of the owner; and\n(d) a mortgagee in possession;\n(49) \"Parapet\" means a low wall or railing built along the edge of a roof or a floor;\n(50) \"Parking space\" means an area enclosed or un-enclosed, covered or open, sufficient in size to part vehicles together with a driveway connecting the parking space with a street or an alley and permitting ingress and egress of the vehicle;\n(51) \"Permission\" means an authorisation in writing by the Authority to carry out work of development or building, and regulated by these rules, which otherwise would be unlawful;\n(52) \"Plinth\" means the portion of a structure between the surface of the surrounding ground and surface of the floor, immediately above the ground;\n(53) \"Plinth area\" means a built up covered area measured at the plinth;\n(54) \"Room height\" means a vertical distance measured from the finished floor surface to the finished ceiling surface. Where a finished ceiling is not provided, the underside of joints or beams or tie-beams shall determine the upper point of measurement;\n(55) \"Row housing/Row type building\" means a row of buildings with only front, rear and interior open spaces;\n(56) \"Sanctioned plan\" means the set of plans and specifications submitted under the rules in connection with a building and duly approved and sanctioned by the Authority;\n(57) \"Semi-detached Building\" means a building detached on three sides;\n(58) \"Service lane\" means a road/lane provided at the rear or side of a plot for service purposes;\n(59) \"Set back line\" means a line usually parallel to the plot boundaries and laid down in each case by the Authority beyond which nothing can be constructed towards the site boundaries.\n(60) \"Site\" means a parcel of land enclosed by definite boundaries;\n(61) \"Site corner\" means a site at the junctions of two or more intersecting street; 6\n(62) \"Site interior or tandem\" means site, access to which is by a passage from a street, whether such passage forms part of the site or not;\n(63) \"Storey\" means the portion of a building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it;\n(64) \"Street\" means any means of access, namely, highway, street, lane, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether a thoroughfare or not, over which the public have a right of passage or access or have passage and had access uninterruptedly for a specified period whether existing or proposed in any scheme and includes all bunds, channels, ditches, storm water drains, culverts sidewalks, traffic inslands, roadside trees and hedges retaining walls, fences, barriers and railines within the street lines;\n(65) \"Street level or grade\" means the officially established elevation or grade of the central line of the street upon which a plot fronts and if there is no officially established grade, the existing grade of the street at its mid-point;\n(66) \"Street line\" means the line defines the side limits of a street;\n(67) \"To erect\" or \"to erect a building\" means-\n(a) to erect a new building on any site whether previously built upon or not;\n(b) to re-erect any building of which portions above the plinth level have been pulled down, burnt or destroyed; and\n(c) conversion from one occupancy to another;\n(68) \"To abut\" means to abut on a street such that any portion of the building is on the road boundary;\n(69) \"Travel distance\" means distance from the remotest point on a floor of a building to a place of safety, whether it is vertical exist, or a horizontal exist or an outside exist measured along the line of travel;\n(70) \"Varandah\" means covered area with atleast one side open to the outside with the exceptions of parapet which may be of the height of one metre on the upper floors as may be provided on the open side;\n(71) \"Water Closet (WC)\" means a privy with arrangement for flushing the pan with water;\n(72) \"Window\" means an opening to the outside than a door which provides all or part of the required natural light or ventilation or both to an interior space.",
"footnote": "",
"is_definition": true,
"sort_order": 1
},
{
"number": "3",
"title": "3. Applicability of the rules.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "4",
"title": "4. Rules not to apply to operational construction of the Government.",
"chapter": null,
"content": "(i) lands to which sub-section 4 of Section 1 of the Act applies; and\n(ii) operational constructions.\n(a) new residential buildings (other than gate-lodges, quarters for limited essential operational staff);\n(b) roads and drains in colonies, hospitals, clubs, institutions and schools.",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "5",
"title": "5. Existing Building.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "6",
"title": "6. Alternative materials, methods of design and construction and tests.",
"chapter": null,
"content": "Part II\nOrganisation and Enforcement",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "7",
"title": "7. Department of building inspection.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "8",
"title": "8. Power and duties of the building officer.",
"chapter": null,
"content": "(i) shall receive all applications for permission under Rule 17 and may issue permission;\n(ii) shall examine the premises for which permissions have been issued and ensure compliance with these rules;\n(iii) may as and when necessary issue all necessary notices or orders to (a) remove illegal or unsafe construction, (b) require necessary safeguards during development or construction, (c) require adequate exit facilities in existing buildings and (d) ensure compliance with all the requirements of safety, health and general welfare of the public as contained in these rules.",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "9",
"title": "9. Right of Entry.",
"chapter": null,
"content": "(i) in the case of any building used as a dwelling house, or upon any enclosed part of garden attached to such building, no such entry shall be made except between the hours of sunrise and sunset or without giving its occupiers atleast 24 hours, notice in writing of the intention to enter;\n(ii) sufficient opportunity shall in every instance be given to enable to women (if any) to withdraw from such land or building;\n(iii) due regard shall always be had so far as may be compatible with the exigencies of the purpose for which the entry is made, to the social and religious usages of the occupants of the land or building entered.",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "10",
"title": "10. Inspection.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "11",
"title": "11. Constructions not according to Plan.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "12",
"title": "12. Occupancy Violations.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "13",
"title": "13. Board of Appeal.",
"chapter": null,
"content": "(i) a District Judge or Additional District Judge or a retired officer having not less than 5 years administrative experience as Collector or Additional Collector as the Chairman.\n(ii) The Joint or Deputy Director, Town and Country Planning for the area as a member.\n(iii) A representative nominated by the Authority as a member : Provided that if any appeal involves any matter falling under clause (c) or of sub-rule (2) and the Board does not have a member having requisite qualification and experience as a Civil Engineer the Chairman may coopt an officer of State P.W.D. not below the rank of a Superintendent Engineer for hearing such appeal.\n(a) conditions, if any, attached to the grant of permission;\n(b) the grounds on which permission has been refused;\n(c) suitability of alternative materials or methods of design or construction.\nPart III\nPermission and Inspection",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "14",
"title": "14. Permission for Development or for Construction.",
"chapter": null,
"content": "(i) Such alteration under below mentioned heads in a building, as do not otherwise violate any provisions regarding general building requirements, structural stability and fire safety requirements of these rules,-\n(a) opening and closing of a window or door or ventilator;\n(b) providing inter-communication doors;\n(c) providing partitions;\n(d) providing false ceilings;\n(e) gardening;\n(f) white washing;\n(g) painting;\n(h) re-tiling and repairing of roof;\n(i) plastering and patch work;\n(j) re-flooring;\n(k) constructions of sun shades on one's own land;\n(l) re-erection of portions of buildings damaged by earth-quake or other natural calamities, to the same extent and specifications as existed prior to such damage;\n[(m) re-erection of portion of buildings damaged by any other calamity as may be notified by the District Collector with the previous approval of the State Government to the same extent and specification as existed prior to damage] .\n(ii) carrying out works in compliance with any order or directions made by any authority under any law for the time being in force;\n(iii) carrying out works by any authority in exercise of its powers under any law for the time being in force;\n(iv) carrying out by the Central or the State Government or any local authority any work,-\n(a) required for the maintenance or improvement of a highway, road or public street, being works carried out on land within the boundaries of such highway, road or public street;\n(b) for the purpose of inspecting, repairing or renewing any drains, sewers, mains, pipes, cables, telephone or other apparatus including the breaking open of any street or other land for that purpose :\n(A) Site clearance committee within Municipal Corporation area\n(1)\nMunicipal Commissioner\nChairman\n(2)\nSuperintendent of Police or his nominee not below the rank of\n\t\t\t\tDeputy Superintendent of Police or City Superintendent of Police,\n\t\t\t\tas the case may be.\nMember\n(3)\nExecutive Engineer of PWD (B & R) nominated by the\n\t\t\t\tSuperintending Engineer\nMember\n(4)\nDivisional Engineer of the respective jurisdiction the Madhya\n\t\t\t\tPradesh Electricity Board\nMember\n(5)\nA representative of the Fire Authority or an officer not below\n\t\t\t\tthe rank of Assistant Fire Officer of any Corporation in the\n\t\t\t\tdistrict nominated by the Collector\nMember\n(6)\nJoint Director/Deputy Director of the Town & Country\n\t\t\t\tPlanning Department to be nominated by the Director, Town &\n\t\t\t\tCountry Planning.\nMember\n(B) Site Clearance Committee outside Municipal Corporation area\n(1)\nCollector of the District\nChairman\n(2)\nChief Executive Officer of Zila Panchayat/Chief Municipal\n\t\t\t\tOfficer of urban local body as the case may be, of the authority\n\t\t\t\tconcerned.\nMember\n(3)\nSuperintendent of Police or his nominee not below the rank of\n\t\t\t\tDeputy Superintendent of Police or City Superintendent of Police,\n\t\t\t\tas the case may be.\nMember\n(4)\nExecutive Engineer of PWD (B & R) nominated by the\n\t\t\t\tSuperintending Engineer.\nMember\n(5)\nDivisional Engineer of the respective jurisdiction of the\n\t\t\t\tMadhya Pradesh Electricity Board.\nMember\n(6)\nA representative of the Fire Authority or an Officer not below\n\t\t\t\tthe rank of Assistant Fire Officer of any Corporation in the\n\t\t\t\tdistrict nominated by the Collector.\nMember\n(7)\nJoint Director/Deputy Director of the Town & Country\n\t\t\t\tPlanning Department to be nominated by the Director, Town &\n\t\t\t\tCountry Planning.\nMember Secretary]\n(v) the erection (including wells) made in the ordinary course of agricultural operation;\n(vi) the construction of a road intended to give access to land solely for agricultural purposes;\n(vii) the normal use of land which has been used temporarily for other purposes like marriage pandals, or for festive occasions; and\n(viii) in case of land, normally used for no purpose or occasionally used for any purpose, the use of land for the other purpose or occasions, not involving permanent diversion or diversion for substantial period.",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "15",
"title": "15. Development/Building permit issued prior to these Rules.",
"chapter": null,
"content": "[16. Application for permission for Development or for Building.\n17. (1) Information Accompanying Notice.\n(2) Drawing sheet Sizes\n(a) The size of drawing sheets shall be any of those specified in Table 1.\nTable 1\nTable 1\nDrawing Sheet Sizes\nDrawing Sheet Sizes\n[Rule 17 (2)(a)]\nS.No.\nS.No.\nDesignation\nDesignation\nTrimmed sized mm.\nTrimmed sized mm.\nUntrimmed size mm.\nUntrimmed size mm.\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\n(4)\n(4)\n1.\nA0\n841 X 1,189\n980 X 1,230\n2.\nA1\n594 X 841\n625 X 880\n3.\nA2\n420 X 594\n450 X 625\n4.\nA3\n297 X 420\n330 X 450\n5.\nA4\n210 X 297\n240 X 330\n6.\nA5\n148 X 210\n165 X 240\n(b) Recommended Notation for Colouring Plans. - The plans shall be coloured as specified in Table-2.\n(b) Recommended Notation for Colouring Plans.\nTable 2\nTable 2\nColouring Plans\nColouring Plans\n[Rule 17 (2)(b)]\nSl. No.\nItem\nSite plan\nBuilding Plan\nWhite plan\nBlue print\nAmmonia Print\nWhite plan\nBlue Print\nAmmonia Print\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n(7)\n(8)\n1.\nPlot lines\nThick Black\nThick Black\nThick Black\nThick Black\nThick Black\nThick Black\n2.\nExisting street\nGreen\nGreen\nGreen\n3.\nFuture street, if any\nGreen dotted\nGreen dotted\nGreen dotted\n4.\nPermissible building lines\nThick dotted black\nThick dotted black\nThick dotted black\n5.\nOpen spaces\nNo Colour\nNo Colour\nNo Colour\nNo Colour\nNo Colour\nNo Colour\n6.\nExisting work\nBlack (out line)\nWhite\nBlue\nBlack\nWhite\nBlue\n7.\nWork proposed to be demolished\nYellow hatched\nYellow hatched\nYellow hatched\nYellow hatched\nYellow hatched\nYellow hatched\n8.\nProposed work (See Note 1)\nRed filled in\nRed\nRed\nRed\nRed\nRed\n9.\nDrainage and Sewerage work\nRed dotted\nRed dotted\nRed dotted\nRed dotted\nRed dotted\nRed dotted\n10.\nWater supply work\nBlack dotted thin\nBlack dotted thin\nBlack dotted thin\nBlack dotted thin\nBlack dotted thin\nBlack dotted thin\nNote 1. - For entirely new construction this need not be done. For extension of an existing work this shall apply.\nNote 1.\nNote 2. - For land development, sub-division, layout, suitable colouring notations shall be used which shall be indexed.\nNote 2.\n(3) Key Plan.\n(4) Site Plan.\n(a) the boundaries of the site with dimensions and of any contiguous land belonging to the applicant indicating Khasra number or any other equivalent local denominations and in case the contiguous land owned by the applicant had been sub-divided earlier, public facilities provided in it and all streets within it opening out in the site for which the permission is being sought;\n(b) the position of the site in relation to neighbouring street;\n(c) the name of the street in which the building is proposed to be situated, if any;\n(d) all existing buildings standing on, over or under the site including service lines;\n(e) the position of the building, and of all other buildings (if any) which the applicant intends to erect upon his contiguous land referred to in (a) in relation to,-\n(i) the boundaries of the site and in case where the site has been partitioned, the boundaries of the portion owned by the applicant and also of the portions owned by others;\n(ii) all adjacent streets, buildings (with number of storeys and height) and premises within a distance of 12 m of the site and of the contiguous land (if any) referred to in (a); and\n(iii) if there is no street within a distance of 12 m of the site, the nearest existing street;\n(f) the means of access from the street to the building, and to all other buildings (if any) which the applicant intends to erect upon his contiguous land referred to in (a);\n(g) space to be left about the building to secure a free circulation of air, admission of light and access for scavenging purposes;\n(h) the width of the street (if any) in front and of the street (if any) at the side or near the buildings;\n(i) the direction of north point relative to the plan of the buildings;\n(j) the position of all existing features like high tension line, telegraph and electrical poles, underground pipe lines, trees, grave yards, religious buildings, railway lines, etc. within a distance of 30 metres from the nearest edge of the site, all major physical features of land proposed to be developed which include the approximate location and size of any water body, flood affected areas and contours at an interval of 0.3 metres, in case of the site which has a slope more than 1 in 20;\n(k) present and proposed use of the land; and\n(l) such other particulars as may be prescribed by the Authority.\n(5) Sub-Division/Layout Plan.\n(a) scale used and north point;\n(b) the location of all proposed and existing roads with their existing/proposed/prescribed width within the land;\n(c) dimensions of plot alongwith building lines showing the setbacks with dimensions within each plot;\n(d) the location of drains, sewers, public facilities and services, and electrical lines, etc.\n(e) table indicating size, area and use of all the plots in the sub-division/layout plan;\n(f) a statement indicating the total area of the site, area utilized under roads, open spaces for parks, play-grounds, recreation spaces and development plan reservations, schools, shopping and other public places alongwith their percentage with reference to the total area of the site proposed to be subdivided; and\n(g) in case of plots which are sub-divided in built-up areas in addition to the above, the means of access to the sub-division from existing streets.\n(6) Building Plan.\n(a) include floor plans of all floors together with the covered area clearly indicating the size and spacings of all framing members and sizes of rooms and the position of staircases, ramps and liftwells;\n(b) show the use of occupancy of all parts of the building;\n(c) show exact locations of essential services, for example, water closet, sink, bath including the water supply and drainage line;\n(d) include sectional drawing showing clearly the sizes of footings, thickness of basement wall, wall construction, size and spacing of framing members, floor slabs and roof slabs with their materials and size and locations of doors, windows and other openings. The section shall indicate the heights of buildings and rooms and also the height of the parapets; and the drainage and the slope of the roof. At least one section should be taken through the staircase;\n(e) schedule showing calculations and designs in respect of RCC work, if any, involving structural engineering such as roof, slabs, columns, frame etc.;\n(f) show all street elevations;\n(g) indicate details of served privy, if any;\n(h) give dimensions of the projected portions beyond the permissible building line;\n(i) include terrace plan indicating the drainage and the slope of the roof;\n(j) give indications of the north point relative to the plan, and the scale used;\n(k) schedule of built up area floor-wise, F.A.R., proposed schedule of set backs and coverage; and\n(l) for commercial building, indicate the placement and size of display boards;\n(ii) [Building Plan for high rise/special Building] . - [For high rise buildings] and for special buildings like educational assembly, institutional, industrial, storage and hazardous and mixed occupancies with any of the aforesaid occupancies having area more than 500 square metres the following additional information shall be furnished or indicated in the Building Plan in addition to the items given in item (i) above as applicable-\n[Building Plan for high rise/special Building] .\n(a) access to fire appliances/vehicles with details of vehicular turning circle and clear motorable accessway around the buildings;\n(b) size (width) of main and alternate staircases along with balcony approach, corridor, ventilated lobby approach,\n(c) location and details of lift enclosures;\n(d) location and size of fire lift;\n(e) smoke stop lobby/door, where provided;\n(f) refuse chutes, refuse chamber, service duct;\n(g) vehicular parking spaces;\n(h) refuse area, if any;\n(i) details of building services-Air-conditioning system with position of fire dampers, mechanical ventilation system, electrical services, boilers, gas pipes;\n(j) details of exits including provision of ramps, etc. for hospitals and special risks;\n(k) location of generator, transformer and switch gear room;\n(l) smoke exhauster system, if any;\n(m) details of fire alarm system net work;\n(n) location of centralized control, connecting all fire alarm systems, built-in-fire protection arrangements and public address system etc.;\n(o) location and dimensions of static water storage tank and pump room along with fire service inlets for mobile pump and water storage tank;\n(p) location and details of fixed fire protection installations such as sprinklers, wet risers hose-reels, drenchers, carbon-dioxide installations; and\n(q) location and details of first aid fire fighting equipments or installations.\n[(iii) in respect of high rise buildings, the following additional information shall be given in addition to the information accompanying the notice, that is to say-\n(a) Urban Planning :\n- Land use as per Master Plan\n- Land use as per Zonal Plan (if any)\n- Land use as per Layout Plan (if any)\n- Proposed density.\n(b) Traffic Planning :\n- Width of existing road.\n- Width of proposed road.\n- Provision of service road.\n- A comprehensive circulation plan of the plot and of its adjoining areas.\n- Arrangements for parking vehicles.\n(c) Fire prevention, fighting and protection Planning:\n- Details of fire detection and fire fighting arrangements,\n(d) Planning of Services :\n- Internal water, sewerage, drainage, power, tele-communication, garbage disposal and scavenging of common spaces.\n- Peripheral water, sewerage, drainage and power.\n- Trunk water, sewerage, drainage, power, tele-communication and garbage disposal.\n(e) Architecture:-\n- Plans of each floor.\n- Necessary number of cross-sections.\n- Elevations of each sides.\n- Details of toilet blocks and kitchen.\n- Details of landscaping from Electric poles, Telephone poles.\n- Systems of power connections from Electric poles, Telephone poles, Dust bins numbering parking of different vehicles, covering of drains, over-head tanks, underground water tank, tree plantation and landscaping.]\n(7) Service Plan.\n(8) Specification.\n(ii) Every application for permission for sub-division of land shall also be accompanied by the following statements :-\n(a) a statement containing general specifications of all improvements proposed to be made within the area e.g., grading and paving of roads and lanes, provisions of gutters, side drains, provision for sufficient, safe and assured water supply, arrangement of sewage disposal, street lighting and development of parks and play-fields and public utility;\n(b) the purpose for which the land is to be used and particulars of proposed distribution of land under different uses;\n(c) general specifications of the material to be used, estimated cost of the proposed development of the area; and\n(d) any other statement required by the Authority.\n(9) Supervision.\n(10) Certificate of structural design.\n(11) Proof of title etc.\n(a) attested copy of the original sale deed, lease deed, or any ether document under which right, title or interest in land or plot is claimed;\n(b) attested copy of the Khashra plan and Khatauni record, if any; or\nKhashra\nKhatauni\n[(i) attested copy of No objection Certificate from Nazul (Provided that in case the No Objection Certificate for the entire approved layout has been taken from the concerned Nazul authority, Individual plot owners in the layout shall not be required to submit Individual No Objection Certificates from the Nazul authority :\n(c) other documents acceptable to the Authority.\n(i) Minimum size of the plot shall be 4045 sqm (one acre.)\n(ii) Maximum F.A.R. shall be 0.10.\n(iii) The maximum height of structure shall be 6.5 meters with sloping roof.\n(iv) The Forest House shall have a minimum of 200 live trees per acre to be planted before the application for building constructions is made to the Authority for approval.\n(v) The Forest House shall only be permitted on that land which is accessible by public passage/road, OR the area layout plan approved by the Director.\n(vi) The Forest House shall have a minimum 10 metres set back from all sides.]",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "18",
"title": "18. Preparation and signing of plans.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "19",
"title": "19. Notice for alteration only.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "20",
"title": "20. Notice for land adjoining the Government property.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "21",
"title": "21. Fees.",
"chapter": null,
"content": "(1) Validity of Notice subject to payment of Fees.\n(2) Fees not Refundable.\n(3) Scale of Fees.\n(a) For permission for development-\n(i)\nfor development of area upto 1 hectare.\nRs. 500.00\n(ii)\nfor development of area exceeding 1 hectare but not exceeding\n\t\t\t\t2.5 hectares.\nRs. 1000.00\n(iii)\nfor development of area exceeding 2.5 hectares but not\n\t\t\t\texceeding 5 hectares.\nRs. 1500.00\n(iv)\nfor development of area exceeding 5 hectares, for every 5\n\t\t\t\thectares or part there of, additional fee at.\nRs. 500.00\n(b) For permission for buildings other than high rise buildings\nItem No.\nType of Construction\nBuilt up area\nFees chargeable in rupees\nSq. meter to\nSq. metre\n(1)\n(2)\n(3)\n(4)\n(5)\n1.\nA building intended to be exclusively for residence.\n0 76 126 201 301 401 601 751 1001 1251 1501 2001 above\n\t\t\t\t2500\n75 125 200 300 400 600 750 1000 1250 1500 2000 2500\n200.00 350.00 600.00 900.00 1200.00 2000.00 2500.00 3500.00 5000.00 7000.00 10000.00 15000.00 25000.00\n2.\nA building intended to be used as shop, store house, factory\n\t\t\t\tor for carrying on trade or business or any other commercial or\n\t\t\t\tindustrial purpose.\nFee specified in item No. 1 together with an additional charge\n\t\t\t\tof 50% of such amount of fees, except that for a built up area\n\t\t\t\tabove 2500 square metres the fees chargeable shall be Rs.\n\t\t\t\t40,000/-.\n3.\nA building intended to be used as administrative block in a\n\t\t\t\tfactory.\nFees as prescribed in item No. 1.\n4.\nA building intended to be used for shop-cum-residence\n\t\t\t\tpurposes.\nFees specified in item No. 1 together with an additional\n\t\t\t\tcharge of 50% of such amount of fees.\n5.\nA building intended to be used as Cinema theatre.\nUpto 800 seating capacity, Rs. 15,000.00 Above 800 seating\n\t\t\t\tcapacity Rs. 25,000.00\n6.\nA building intended to be used for any social charitable,\n\t\t\t\tcultural, educational purposes, Dharamshala and similar types of\n\t\t\t\tbuildings and for any other purposes not specifically provided\n\t\t\t\tfor.\n50% of fees specified in item No. 4.\n7.\nAddition or alteration with built up area or external addition\n\t\t\t\tor alteration which does not add to the built up area such as\n\t\t\t\tCourt yard compound wall, alteration in elevation or roofing such\n\t\t\t\tas tiles to A.C. Sheet or flat surface, additional opening or\n\t\t\t\tclosing not covered by provision to sub rule (1) of Rule 14.\nRs. 50.00 in each case of building mentioned in item Nos. 1,3\n\t\t\t\tand 6. Rs. 200.00 in each case of building mentioned in item\n\t\t\t\tNos. 2, 4 and 5.\n8.\nIn case of addition or alteration in the proposed plan:\nUp to 5% Above 5% and up to 10% Above 10%\nNil Rs. 50.00 Fresh application according to the rules\n\t\t\t\tshall be necessary\n9.\nRevalidation of the building permission.\n10% of the amount of fees charged originally in respect of the\n\t\t\t\tbuilding concerned.\n(c) For permission for high-rise buildings.\nItem No.\nItem No.\nType of construction\nType of construction\nFees chargeable in rupees.\nFees chargeable in rupees.\n1.\nA building intended to be exclusively for residence.\nRs. 10.00 per Sq. Mtr. floor area space.\n2.\nA building intended to be used as shops, store house, factory\n\t\t\t\t\tor for carrying on trade or business or any other commercial or\n\t\t\t\t\tindustrial purpose.\nFees as prescribed in Item No. 1 with additional charges of\n\t\t\t\t\t100% of amount of fees.\n3.\nA building intended to be used as administrative block in a\n\t\t\t\t\tfactory.\nFees as prescribed in Item No. 1.\n4.\nA building intended to be used for shop-cum-residence\n\t\t\t\t\tpurposes.\nFees specified in Item No. 1 together with additional charges\n\t\t\t\t\tof 50% of such amount of fees.\n5.\nA building intended to be used for any special, charitable,\n\t\t\t\t\tcultural, educational purposes including hospital, school, club,\n\t\t\t\t\tDharamshala and similar types of buildings and for any other\n\t\t\t\t\tpurpose not specifically provided for.\n50% of fees specified for Item No. 1.\nOLD LAW 6\nLegislative Changes and Previous Position\nLegislative Changes and Previous Position\nClauses (b) and (c) before substitution were as under:-\n\"(b) For permission for buildings other than high rise building.\nItem No.\nType of Construction\nBuilt up area\nFees chargeable in rupees\nSq. meter to\nSq. metre\n(1)\n(2)\n(3)\n(4)\n(5)\n1.\nA building intended to be exclusively for residence.\n0 76 126 201 301 401 601 751 1001 1251 1501 2001 above\n\t\t\t\t2500\n75 125 200 300 400 600 750 1000 1250 1500 2000 2500\n100.00 200.00 300.00 450.00 700.00 1000.00 1500.00 2500.00 3000.00 4000.00 5000.00 6500.00 8500.00\n2.\nA building intended to be used as shop, store house, factory\n\t\t\t\tor for carrying on trade or business or any other commercial or\n\t\t\t\tindustrial purpose.\nFee specified in item No. 1 together with an additional charge\n\t\t\t\tof 50% of such amount of fees, except that for a built up area\n\t\t\t\tabove 2500 square metres the fees chargeable shall be Rs.\n\t\t\t\t15,000/-\n3.\nA building intended to be used as administrative block in a\n\t\t\t\tfactory.\nFees as prescribed in item No. 1.\n4.\nA building intended to be used for shop-cum-residence\n\t\t\t\tpurposes.\nFees specified in item No. 1 together with an additional\n\t\t\t\tcharge of 25 of such amount of fees.\n5.\nA building intended to be used as Cinema theatre.\n0 to 800 seating capacity, Rs. 4,000.00 800 and above\n\t\t\t\tseating capacity Rs. 7,500.00\n6.\nA building intended to be used for any social charitable,\n\t\t\t\tcultural, educational purposes, incluiding for Hospital, School,\n\t\t\t\tClub, Dharamshala and similar types of buildings and for any\n\t\t\t\tother purposes not specifically provided for.\n50% of fees specified in item No. 1.\n7.\nAddition or alteration with built up area or external addition\n\t\t\t\tor alteration which does not add to the built up area such as\n\t\t\t\tCourt yard compound wall, alteration in elevation or roofing such\n\t\t\t\tas tiles to A.C. Sheet or flat surface, additional opening or\n\t\t\t\tclosing not covered by provision to sub rule (1) of Rule 14.\nRs. 25.00 in each case of building mentioned in item Nos. 1,3\n\t\t\t\tand 6. Rs. 100.00 in each case of building mentioned in item\n\t\t\t\tNos. 2, 4 and 5.\n8.\nIn case of addition or alteration in the proposed plan:\nUp to 5% Above 5% and up to 10% Above 10%\nNil Rs. 50.00 Fresh application according to the rules\n\t\t\t\tshall be necessary\n9.\nRevalidation of the building permission.\n5% of the amount of fees charged originally in respect of the\n\t\t\t\tbuilding concerned.\n(c) For permission for high-rise buildings.\nItem No.\nItem No.\nType of construction\nType of construction\nFees chargeable in rupees.\nFees chargeable in rupees.\n1.\nA building intended to be exclusively for residence.\nRs. 5.00 per Sq. Mtr. floor area space.\n2.\nA building intended to be used as shops, store, house,\n\t\t\t\t\tfactory or for carrying on trade or business or any other\n\t\t\t\t\tcommercial or industrial purpose.\nFees as prescribed in Item No. 1 with additional charges of\n\t\t\t\t\t100% of amount of fees.\n3.\nA building intended to be used as administrative block in a\n\t\t\t\t\tfactory.\nFees as prescribed in Item No. 1.\n4.\nA building intended to be used for shop-cum-residence\n\t\t\t\t\tpurposes.\nFees specified in Item No. 1 together with additional charges\n\t\t\t\t\tof 25% of such amount of fees.\n5.\nA building intended to be used for any social, charitable,\n\t\t\t\t\tcultural, educational purposes including hospital, school, club,\n\t\t\t\t\tDharamshala and similar types of buildings and for any other\n\t\t\t\t\tpurpose not specifically provided for.\n50% of fees specified for Item No. 1.\n(4) Standard Plan Permission.",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "22",
"title": "22. Withdrawal of application.",
"chapter": null,
"content": "[23. Duration of sanction.\n[24. Deviation during construction.\n(a) Front M.O.S.\n(b) Building Height\n(c) Parking/Public utility space.]",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "25",
"title": "25. Revocation of Permission.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "26",
"title": "26. Licensing of Architect/Engineer etc.",
"chapter": null,
"content": "Designation\nDesignation\nMinimum Qualification\nMinimum Qualification\n1.\nArchitect\nArchitects registered under the Architects Act, 1972.\n2.\nStructural Engineer\nGraduate in Civil Engineering of recognised Indian or Foreign\n\t\t\t\t\tUniversity and Chartered Engineer or Associate Member in Civil\n\t\t\t\t\tEngineering Division of Institution of Engineers (India) or\n\t\t\t\t\tequivalent Overseas Institution with three years experience in\n\t\t\t\t\tstructural engineering practice with designing and field work:\nProvided that the three years experience shall be relaxed to-\n(a) two years in case of postgraduate degree of recognised\n\t\t\t\t\tIndian or Foreign University with branch of Structural\n\t\t\t\t\tEngineering;\n(b) one year in case of Doctorate in Structural Engineering.\n3.\nEngineer\nThe Corporate Membership (Civil) of the Institution of\n\t\t\t\t\tEngineers (India) or such Degree or Diploma in Civil, Municipal\n\t\t\t\t\tor Structural Engineering which makes him eligible for such\n\t\t\t\t\tmembership.\n4.\nSupervisor\nThe qualification in Architecture or Engineering equivalent\n\t\t\t\t\tto the minimum qualification prescribed for direct recruitment\n\t\t\t\t\tto non-gazetted service as Architectural assistant or sub\n\t\t\t\t\tengineer by the Government of India or the State Government with\n\t\t\t\t\t5 years experience in building design, construction and\n\t\t\t\t\tsupervision.\nOR\n3 years Diploma in Engineering (Civil) or in Architecture\n\t\t\t\t\tfrom recognised Board with 5 years experience in building\n\t\t\t\t\tdesign, construction and supervision.\n5.\nTown Planner\nAssociate Membership of the Institute of Town Planner or\n\t\t\t\t\tPost-Graduate Degree or Diploma in Town and Country Planning\n\t\t\t\t\twhich makes him eligible for such membership or recognised by\n\t\t\t\t\tthe State Government for the post of Assistant Director Town\n\t\t\t\t\tPlanning holding a degree in Architecture or Civil Engineering\n\t\t\t\t\tor equivalent thereto:\nProvided that no person who immediately before the coming\n\t\t\t\t\tinto force of these rules, in any area, was holding a licence\n\t\t\t\t\tfrom any municipal corporation/municipal council for carrying\n\t\t\t\t\tout any work which is now in this rule included within the\n\t\t\t\t\tcompetence of a supervisor shall be refused a licence to work as\n\t\t\t\t\tsupervisor merely on the ground of qualification prescribed in\n\t\t\t\t\tthe rule.\n(i) certificates on which the claim is based; and\n(ii) receipt in token of payment of licence fee.\nFee.\n(i)\nFor Architect, Structural Engineer, Engineer & Town\n\t\t\t\tPlanner\nRs. 500.00\n(ii)\nFor Supervisor\nRs. 250.00\n(iii)\nFor a Group or Agency\nRs. 1250.00]\nCompetence of the licensee.\n(A) Architect. - Competence. - The licensed Architect shall be competent to carryout the work related to the permission for building and shall be entitled to submit :\n(A) Architect. - Competence.\n[(a) all plans and information connected with permission for all buildings irrespective of size and height;]\n(b) structural details and calculations for residential buildings on plot up to 500 square metres and up to three storeys or 11 metres in height;\n(c) certificate of supervision and completion of all buildings:\n(d) all plans and related information connected with permission for development of area up to 1 hectare; and\n(e) certificate of supervision for development of land area up to 1 hectare.\n(B) Structural Engineer. - Competence. - The licensed Structural Engineer shall be competent to carry out the work relating to permission of building etc. and shall be entitled to submit :\n(B) Structural Engineer. - Competence.\n[(a) all plans and information connection with permission for residential buildings on plot upto 500 sqm. and upto three storeys or 11 m in height;]\n(b) the structural details and calculation for all buildings;\n(c) certificate of supervision and completion of all buildings;\n(d) all plans and related information connected with permission for development of area up to one hectare;\n(e) certificates of supervision for development of land are up to one hectare.\n(C) Engineer. - Competence. - The licensed engineer shall be competent to carry out the work related to the permission for building as given below and shall be entitled to submit :\n(C) Engineer. - Competence.\n[(a) all plans and information connected with residential buildings on plot upto 300 sqm. and upto two storeys or 7.5 m in height;]\n(b) structural details and calculation for all buildings up to 500 square metres and four storeys (15m);\n(c) certificate of supervision and completion for all buildings;\n(d) all plans and related information connected with permission for development of area up to 1 hectare; and\n(e) certificate of supervision for development of land of area up to 1 hectare.\n(D) Supervisor-Competence. - The licensed Supervisor shall be entitled to submit :\n(D) Supervisor-Competence.\n(a) all plans and related information connected with the permission for residential buildings up to 200 square metres and up to two storeys or 7.5 metres height;\n(b) certificate of supervision for buildings in (a).\n(E) Town Planner-Competence. - The licensed Town Planner shall be entitled to submit :\n(E) Town Planner-Competence.\n(a) all plans and related information connected with permission for development of all areas;\n(b) certificate of supervision for development of land of all areas.\n(F) Group or Agency. - When an agency or a group of qualified architects, engineers, town planners is practising, then the qualification and competence of work shall be the combination of the individual qualifications and competence.\n(F) Group or Agency.",
"footnote": "",
"is_definition": false,
"sort_order": 21
},
{
"number": "27",
"title": "27. Grant of permission or refusal.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 22
},
{
"number": "28",
"title": "28. Limitation period for grant or refusal of permission.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 23
},
{
"number": "29",
"title": "29. Reasons to be given when permission refused.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 24
},
{
"number": "30",
"title": "30. Owner to resubmit plan complying with objections.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 25
},
{
"number": "31",
"title": "31. Responsibilities and duties of the owner.",
"chapter": null,
"content": "(a) permit the Authority or person authorised by it or the Building Officer or person duly authorised by him to enter the building or premises for which the permit has been granted at any reasonable time for the purpose of ensuring the compliance of these rules;\n(b) submit a document of ownership of or right or interest in relation to the site;\n(c) obtain, where applicable, from the Authority, permission relating to building, zoning, grades, sewers, water-mains, plumbing, signs, blasting, street, occupancy, electricity, highways, and all other permissions required in connection with the proposed work;\n(d) give notice to the Authority of the intention to start work on the building site ( See Appendix E);\n(e) give notice in writing to the Building Officer to arrange inspection when the work reaches plinth level ( See Appendix F);\n(f) give written notice to the Authority regarding completion of work described in the permission ( See Appendix G); and\n(g) obtain permission for occupancy ( See Appendix H) from the Authority prior to any :\n(i) occupancy of the building or part thereof after construction or alteration of that building or part; or\n(ii) change in the class of occupancy of any building or part thereof.\n[(h) Upon the request of the owner, the authority will issue occupancy certificate of the building within 30 days from the receipt of such request. If such permission is not issued within 30 days from receipt of the application or suitable instructions for changes have not been issued by the authority within the period it would be deemed that the occupancy permission has been issued as per clause (g).]\n32.",
"footnote": "",
"is_definition": false,
"sort_order": 26
},
{
"number": "33",
"title": "33. Documents at site.",
"chapter": null,
"content": "(a) posted in conspicuous place on the property in respect of which the permission was issued, a copy of the permission for building and/or development, as the case may be; and\n(b) a copy of the approved drawings and specifications referred to in Rule 17 on the property in respect of which the permission was issued.",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
{
"number": "34",
"title": "34. Inspection.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 28
},
{
"number": "35",
"title": "35. Demolition of Building.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 29
},
{
"number": "36",
"title": "36. Architectural control.",
"chapter": null,
"content": "Note. - This clause is intended to very few structures to come up in the vicinity of historically important structures or monuments recognised or declared under any law for the time being in force and the scrutiny shall be limited to the external architectural features only so as to ensure an aesthetic continuance of the existing structures with the new.\nNote.\nPart IV\nDevelopment Control",
"footnote": "",
"is_definition": false,
"sort_order": 30
},
{
"number": "37",
"title": "37. Land use classification and uses permitted-Land use Classification.",
"chapter": null,
"content": "(i)\nResidential Zone\nResidential\n(R 1 )\nResidential with shop Lines at Ground Floor\n(R 2 )\n(ii)\nCommercial Zone\nLocal Commercial Area\n(C 1 )\nDistt. Commercial Area\n(C 2 )\n(iii)\nIndustrial Zone\nService Industries\n(I 1 )\nGeneral Industries\n(I 2 )\nSpecial Industries\n(I 3 )\n(iv)\nGreen Zone.\n(v)\nSpecial Reservations.",
"footnote": "",
"is_definition": false,
"sort_order": 31
},
{
"number": "38",
"title": "38. Industries permitted in R 1 , R 2 and commercial zones.",
"chapter": null,
"content": "(i) industries, listed in Part-I of Appendix J may be allowed in zone R 1 ; provided that not more than 5 workers at a time are employed in such industry and it does not employ or use any steam, electricity, oil, water or any other mechanical power :\n(ii) industries listed in Part I and Part II of Appendix J may be allowed in R 2 zone provided that an industry in Part II uses only electricity with a maximum load of power indicated against each and as per conditions laid down therein;\n(iii) industries listed in Part III of Appendix J with a maximum power load of 5 K.W. may be allowed in commercial zone, in addition to industries listed in Part I and Part II.\n(2) Building use and occupancies to be according to Development plan.\n(3) Uses to be in conformity with the Zone.\n(4) Uses as Specifically Designated on Development Plan.\n(5) Non-conforming Uses.",
"footnote": "",
"is_definition": false,
"sort_order": 32
},
{
"number": "39",
"title": "39. Means of access.",
"chapter": null,
"content": "(1) No building to deprive any other Building of means of Access.\n(2) Building/plot to abut on a public/private means of Access.\n(3) Construction of Building not to encroach upon an area set upon for means of Access.\n(4) Width of means of Access.\nTable 3\nTable 3\nWidth and length of means of access\nWidth and length of means of access\n[Rule 39 (4)]\nS.No.\nS.No.\nWidth of Means of access in metres\nWidth of Means of access in metres\nLength of means of access in metres\nLength of means of access in metres\n1.\n6.0\n100\n2.\n7.5\n150\n3.\n9.0\n250\n4.\n12.0\n400\n5.\n18.0\n1000\n6.\n24.0\nabove 1000\nNote. - (1) The means of access shall be clear of marginal open spaces of at least 3 metres from the existing building line.\nNote.\n(2) If the development is only on one side of the means of access, the prescribed width may be reduced by 1 metre in each case.\n(b) Other Building. - For all industrial buildings, theatres, cinema houses, assembly halls, stadia, educational buildings, markets, other buildings which attract large crowd, the means of access shall not be less than the following-\n(b) Other Building.\nWidth of means of access in metres\nWidth of means of access in metres\nLength of means of access in metres\nLength of means of access in metres\n12.0\n200\n15.0\n400\n18.0\n600\n24.0\nabove 600\n(5) Pathways.\n(6) Width of Pathway for low income housing schemes.\n(7) Length of means of access.\n(8) Authority may require larger width of means of access in general interest.\n(9) Boundary of plots in existing built up area to be shifted with reference to control line of street.",
"footnote": "",
"is_definition": false,
"sort_order": 33
},
{
"number": "40",
"title": "40. Levelling etc. of means of access.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 34
},
{
"number": "41",
"title": "41. Access from Highways/Important Roads.",
"chapter": null,
"content": "42. [Additional Provisions for buildings other than residential buildings] .\n(a) The width of the main street on which the building abuts shall not be less than 12 metres and one end of this street shall join another street of width not less than 12 metres;\n(b) The approach to the building and open spaces on its all sides upto 6 metres width and the layout for the same shall be done in consultation with Fire Authority of the city as approved by the Government and the same shall be hard surface capable of taking the weight of fire engine, weighing up to 18 tonnes. The said open space shall be kept free of obstructions and shall be motorable; and\n(c) Main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5 metres. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If main entrance at boundary wall is built over, the minimum clearance shall be 4.5 metres.\n[42A. Additional provisions for buildings above 12.5 m. height.\n(i) the size of the plot shall not be less than 1000 sq. m. and minimum plot frontage shall not be less than 18 metres. Allowable coverage shall not exceed 30%.\n(ii) the width of main street on which frontage of the building abuts shall not be less than 12 metres.\n(b) High rise buildings :-",
"footnote": "",
"is_definition": false,
"sort_order": 35
},
{
"number": "1",
"title": "1. For building above 18 metres and upto 24 m. height-",
"chapter": null,
"content": "(i) The size of the plot shall not be less than 1500 Sq. m. and minimum plot frontage shall not be less than 21 metres. Allowable coverage shall not exceed 30%.\n(ii) The width of main street on which frontage of the building abuts shall not be less than 18 metres.",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
{
"number": "2",
"title": "2. For building above 24 m. height-",
"chapter": null,
"content": "(i) The size of the plot shall not be less than 2d00 Sq. m. and minimum plot frontage shall not be less than 30 metres. Allowable coverage shall not exceed 30%.\n(ii) The width of main street on which frontage of the building abuts shall not be less than 30 metres.\n(c) For building having height more than 12.5 metres and upto 18 metres the necessary drawings and details shall be submitted to the authority incorporating all the fire fighting measures recommended in National Building Code Part-IV. The occupancy permit shall be issued only after ensuring that the fire fighting provisions are physically provided.\n(d) For all high rise buildings site clearance from District Committee under third proviso to sub-rule (1) of Rule 14 shall be necessary. After the site clearance by the committee, the planning permission from the Town & Country Planning and building permission from the Authority shall be necessary.\n(e) The approach to the building and open spaces on its all sides upto 6 metres width and its layout shall be proposed in consultation with the Fire Authority of the city as approved by the Government and its surface shall be as hard as is required to bear the weight of fire engine of 18 tonnes. The said open space shall be kept free of obstructions and shall be motorable; and\n(f) Main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5 metres. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If the main entrance at boundary wall is built over the minimum clearance shall be 4.5 metres.]",
"footnote": "",
"is_definition": false,
"sort_order": 37
},
{
"number": "43",
"title": "43. Cul-De-Sacs.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
{
"number": "44",
"title": "44. Alley.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 39
},
{
"number": "45",
"title": "45. Intersection of Roads.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
{
"number": "46",
"title": "46. Building Line.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 41
},
{
"number": "47",
"title": "47. Community Open Spaces and Amenities.",
"chapter": null,
"content": "(1) Residential and Commercial Zones.\n(2) Minimum area.\n(i) 10 per cent of the area of the layout; or\n(ii) 0.3 to 0.4 hectare/1000 persons; for low income housing the open spaces shall be 0.2 hectare/1000 persons.\n(3) Area of recreational space.\n(4) Minimum average dimension of recreational space.\n(5) Pavilion/gymnasia.\n(6) Independent means of access.",
"footnote": "",
"is_definition": false,
"sort_order": 42
},
{
"number": "48",
"title": "48. Industrial Zones.",
"chapter": null,
"content": "(1) Amenity open space in Industrial Zones.\n(2) Amenity open space in Industrial plots.",
"footnote": "",
"is_definition": false,
"sort_order": 43
},
{
"number": "49",
"title": "49. Other Amenities.",
"chapter": null,
"content": "Table 4\nTable 4\n[Rule 49 (1)]\nCommunity Facilities and other Sub-Divisions Requirements\nCommunity Facilities and other Sub-Divisions Requirements\nNo.\nFacilities required\nScale of provision (No required)\nArea required and remark\nMain type\nSub-type\n(1)\n(2)\n(3)\n(4)\n(5)\n1.\nEducational facilities.\nNursery School (3 to 5 age group)\n1 for 4000 population.\n0.1 hectare.\nPrimary School (5 to 11 age group).\n1 for 4000 population.\n0.6 hectare for density up to 250\n\t\t\t\t\tpersons per hectare.\n0.5 hectare for density from 251\n\t\t\t\t\tto 500 persons per hectare.\n0.4 hectare for density of 501 persons per hectare &\n\t\t\t\t\tabove\nHigh School (11 to 16 age group).\n1 for 16000 population.\n2.0 hectares for density up to 250\n\t\t\t\t\tpersons per hectare.\n1.8 hectares for density from 251 to 500 persons per hectare.\nDegree College\n1 for 80000 population.\n4 to 6 hectares.\n2.\nHealth Facilities\nHealth center\n1 for every 16000 population\n1.0 hectare with residential staff quarters\nGeneral Hospital\n1 for every 80000 population\n4.0 hectare for 200 beds with ancillaries and staff quarters.\n3.\nCommercial facilities including shopping facilities\nConvenience shopping centre.\nup to 10 shops for 4000 population.\n0.05 to 0.1 hectare\nLocal shopping centre.\nup to 20 shops for 16000 population.\n0.4 hectare.\nZonal shopping centre.\nup to 80 to 100 shops for 80000 population.\n2.5 hectare.\n4.\nCommunication facilities and essential services.\nSub-post office\n1 for every 10000 population\n40 square meters\nPost and Telegraph Office cum Delivery and Booking including\n\t\t\t\t\tTelephone exchange of 1000 lines.\n1 for every 10000 population.\n1.0 hectare.\nElectric Sub-station\n1 in all shopping centers.\n12 meters.\nPolice Station with staff quarters.\n1 for every 50000 population.\n0.8 hectare.\nPolice post with staff quarters\n1 for every 20000 population.\n0.4 hectare.\nFire Station staff quarters.\n1 for every 5 kilometer radial distance.\n0.8 hectare\n5.\nSocial and Cultural Facilities\nReligious building\n1 for every 15000 population\n0.8 hectare location not on a intersection of roads and 60\n\t\t\t\t\tmeters away from Junctions.\nCommunity Hall and library.\n1 for every 15000 population.\n0.3 hectare.\nCinemas\n1 for every 25000 population\n0.3 hectare with parking location in Zonal shopping centers,\n\t\t\t\t\tbusiness and commercial area not in residential zone.\n6.\nFacilities for industrial area.\nLabour Welfare Center.\n1 for every 40 Hectare.\n0.2 hectare.\nConvenience shops\n5 shops of 10 square meters each.\n0.2 hectare.\nBus station.\nHealth center\n1 for every 200 hectare.\n0.6 hectare.\nPost Office\n0.04 hectare.\nTelephone exchanges\n0.06 hectare.\nBank\n200 square meters.\nPetrol pump cum-service-station.\n30 meters x 45 meters.\nPolice Station with staff quarters.\n0.4 hectare.\nFire station staff quarters.\n0.8 hectare.\nNote. - The requirements of essential amenities for low income housing shall be as given in Appendix L.\nNote.",
"footnote": "",
"is_definition": false,
"sort_order": 44
},
{
"number": "50",
"title": "50. Requirements of site.",
"chapter": null,
"content": "(a) if the authority considers that the site is insanitary or that it is dangerous to construct a building on it;\n(b) if the site is within a distance of 9 metres of the highest water mark, and if there be major water course nearby the distance of the plot from the same shall be 9 metres from average high flood mark or 15 metres from the defined boundary of water course, whichever is more;\n(c) if the owner of the building has not shown to the satisfaction of the Authority all the measures required to safeguard the construction from constantly getting damp;\n(d) if the building is for assembly use like cinemas and theatres as well as for public worship, which has not been previously cleared by the Authority;\n(e) if the building is proposed on any area filled up with carcases, excreta, filthy and offensive matter, till the production of certificate from Health Officer and Municipal Engineer to the affect that it is from the health and sanitary point of view, fit to be built upon;\n(f) if the site is not drained properly or is incapable of being well drained;\n(g) if the use of the said site is for the purpose which in the opinion of the Authority, will be a source of annoyance to the health and comfort of the inhabitants of the neighbourhood;\n(h) if the plot has not been approved as a building site either by Authority or City Improvement Trust/Board or Planning Authority;\n(i) if the proposed occupancy of the building on the site does not conform to the land use proposals in the development plans or zoning regulations;\n(j) if the building has to be constructed over/under a Municipal drain/sewer line or water main or overhead transmission line.",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
{
"number": "51",
"title": "51. Surface Water Drains.",
"chapter": null,
"content": "(2) Written permission required to join water drain to a Sewer.",
"footnote": "",
"is_definition": false,
"sort_order": 46
},
{
"number": "52",
"title": "52. Distance from Electric Lines.",
"chapter": null,
"content": "Vertically Metre\nVertically Metre\nHorizontally Metre\nHorizontally Metre\n(a)\nLow and Medium voltage lines and service lines.\n2.5\n1.2\n(b)\nHigh voltage lines up to and including 33000 volts.\n3.7\n1.2\n(c)\nExtra high voltage lines beyond 33000 volts.\n(See Note)\nNote. - For building close to extra high voltage lines beyond 33000 volts clear horizontal corridor of 15 metres, or as specified in the latest version of the Indian Electricity Rules shall be provided.\nNote.",
"footnote": "",
"is_definition": false,
"sort_order": 47
},
{
"number": "53",
"title": "53. Size of Plots.",
"chapter": null,
"content": "(i) Subject to the limitation of the Urban Land (Ceiling and Regulation) Act, 1976 (No. 33 of 1976), each plot shall have a minimum size/front-age corresponding to the type of development as given below :-\nType of Development\nType of Development\nPlot size Square Metre\nPlot size Square Metre\nFrontage Metre.\nFrontage Metre.\nDetached building\nAbove 250\nAbove 12\nSemi-detached building\n125-250\n8 to 12\nRow type building\n50-125\n4.5 to 8\n(ii) For Low Income Group Housing, the minimum plot size shall be as follows, with a coverage not exceeding 75 per vent :-\nType of development\nType of development\nMinimum plot size\nMinimum plot size\nIncremental housing with one room cooking and combined bath\n\t\t\t\tand W.C. on ground floor and future extension of one room and a\n\t\t\t\tbath on first/ground floor.\n30 square metres.\nTwo roomed house on each floor for group housing/individual\n\t\t\t\townership house.\n40 square metres.\nNote. - (1) The minimum size of plots takes into account the need for incremental housing. In the case of cities with population less than 0.5 million, the size of the plot may be increased by 33⅓ percent.\nNote.\nNote. - (2) In exceptional cases in metropolitan cities with population more than 1 million the size of plots may be brought down to 25 square metres in case of low income house colonies located in congested areas or in areas as decided by the Authority:\nNote.\n[Provided that in case of a high rise building the plot shall not be less than 1500 Sq. metres and the width of the plot shall not be less than 21 metres. Subject to the minimum road width stipulation being fulfilled for the relevant category of plots.]\n(2) Industrial.\n(3) Other land uses.\nmangal karyalaya\n(i) Assembly Halls/Cinema Theatres. - The minimum size of plot for assembly building/cinema theatres used for public entertainment with fixed seats shall be on the basis of seating capacity of the building at the rate of 3 metres per seat.\n(i) Assembly Halls/Cinema Theatres.\n(ii) Mangal Karyalaya/Kalyan Mandapam/Barat Ghar/Community Halls. - The size of plot shall not be less than 1000 square metres.\n(ii) Mangal Karyalaya/Kalyan Mandapam/Barat Ghar/Community Halls.\n(iii) Petrol filling Station. - The size of plot shall not be less than :-\n(iii) Petrol filling Station.\n(a) 32 metres X 17 metres in the case of Petrol Filling Station with Kiosk without service bay;\n(b) 37 metres X 31 metres in the case of Petrol Filling Station with service bay.\nPart V\nGeneral Building Requirements\n(i) Classification\n(i) Classification",
"footnote": "",
"is_definition": false,
"sort_order": 48
},
{
"number": "54",
"title": "54. Classification of Buildings.",
"chapter": null,
"content": "(a) Residential;\n(b) Educational;\n(c) Institutional;\n(d) Assembly;\n(e) Business;\n(f) Mercantile (will include both retail and wholesale stores);\n(g) Industrial (will include low, moderate and high fire hazards);\n(h) Storage;\n(i) Hazardous.\n(ii) Open Spaces (within a Plot)\n(ii) Open Spaces (within a Plot)",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
{
"number": "55",
"title": "55. General.",
"chapter": null,
"content": "(2) Open spaces to cater for lighting and ventilation requirement.\n(3) Open spaces separate for each building or wing.\n(4)",
"footnote": "",
"is_definition": false,
"sort_order": 50
},
{
"number": "56",
"title": "56. Residential Buildings-Exterior open spaces.",
"chapter": null,
"content": "(1) Front open space.\nFront open space Min.\nFront open space Min.\nWidth of street facing the plot\nWidth of street facing the plot\n(i)\n1.5 metres\nupto 7.5 metres.\n(ii)\n3.0 metres\n7.5 to 18 metres*\n(iii)\n4.5 metres\n18 to 30 metres.\n(iv)\n6.0 metres\nabove 30 metres.\n*For building up to a maximum height of 7 metres.\nNote. - In case the two or more sides of the building front a street, the values apply to the average width subject to a minimum of 1.8 metres for cases (ii) (iii) and (iv).\nNote.\n(b) For streets less than 7.5 metres in width the distances of the building (building line) shall be at 5 metres from the centre line of the street.\nNote. - This limiting distance has to be determined by the Authority for the individual road/street width taking into account the traffic flow.\nNote.\n(2) Rear Open Space.\n(b) Rear open space to extend through the rear wall. - The rear open space shall be co-extensive with the entire face of the rear wall. If a building abuts on two or more streets, such rear open space shall be provided throughout the entire face of the rear wall. Such rear wall shall be the wall on the opposite side of the face of the building abutting on the wider street unless the Authority otherwise directs.\n(b) Rear open space to extend through the rear wall.\n(3) Side open space.\n(i) For detached buildings there shall be minimum side open spaces of 5 metres on both the sides.\nNote. - For detached residential building upto 7 metres in height on plots with a frontage less than 12 metres one of the side open space may be reduced to 1.5 metres.\nNote.\n(ii) For semi-detached buildings there shall be a minimum side open space of 3 metres on one side.\nNote. - For semi-detached, buildings up to 7 metres in height on plots with a frontage less than 9 metres ( See Rule 53(i) the side open space may be reduced to 1.5 metres.\nNote.\n(iii) For row-type buildings, no side open space is required.\n(b) In the case of semi-detached buildings, the open spaces provided on one side shall be as in this sub-rule and all habitable rooms shall abut either on this side open space or front and rear open spaces or an interior open space.\n(4) Provision of sub-rules (2) and (3) not to apply to certain parking lock up garage.\n(5) Provision of sub-rules (1) to (3) to apply to residential building up to 10 metres in height.\n(6) Open space for building of more than 10 metres height.\nTable 5\nTable 5\nOpen spaces for different heights of buildings\nOpen spaces for different heights of buildings\n[Rule 56 (6)]\nS.No.\nS.No.\nHeight of building in metres\nHeight of building in metres\nOpen spaces to be left around building\n\t\t\t\t\texcepting front on plot in metres\nOpen spaces to be left around building\n\t\t\t\t\texcepting front on plot in metres\n1.\n10\n3\n2.\n15\n5\n3.\n18\n6\n4.\n21\n7\n5.\n24\n8\n6.\n27\n9\n7.\n30\n10\n8.\n35\n11\n9.\n40\n12\n10.\n45\n13\n11.\n50\n14\n12.\n53 and above\n15\nNote 1. - For buildings above 24 metres in height, there shall be a minimum front open space of 6 metres.\nNote 1.\nNote 2. - Where rooms do not derive light and ventilation from exterior open space the width of such exterior open space as given in column (3) may be reduced by 1 metre subject to a minimum of 3 metres and a maximum of 8 metres. No further projections shall be permitted.\nNote 2.\nNote 3. - If the length or depth of the building exceeds 40 metres, add to column (3) 10 per cent of length or depth of building minus 4.0 metres.\nNote 3.\n(8) Interior open spaces. - (a) Inner Courtyard.\n(ii) Further the inner courtyard shall have an area, through out its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard; provided that when any room (excluding staircase bay and bath rooms and water closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.\n(iii) Where only water closet and bath room are abutting on the interior courtyard, the size of the interior courtyard shall be in line with the provision for ventilation shaft as given in clause (b).\n(b) Ventilation Shaft. - For ventilating the spaces for water closet and bath room if not opening on the front, side, rear and interior open spaces, shall open on to the ventilation shaft, the size of which shall not be less than the values given below :-\n(b) Ventilation Shaft.\nHeight of buildings in metres\nHeight of buildings in metres\nSize of ventilation shaft in square metres\nSize of ventilation shaft in square metres\nMinimum size of shaft in metres\nMinimum size of shaft in metres\nUpto 10\n1.2\n0.9\n12\n2.8\n1.2\n18\n4.0\n1.5\n24\n5.4\n1.8\n30\n8.0\n2.4\nabove 30\n9.0\n3.0\nNote 1. - For buildings above 30 metres mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft.\nNote 1.\nNote 2. - For fully air-conditioned residential buildings for lodging purposes the ventilation shaft need not be insisted provided the air-conditioning system works in an uninterrupted manner; also there is an alternate source of power supply.\nNote 2.\n(c) Outer Courtyard. - The minimum width of outer courtyard (as distinguished from its depth) shall be not less than 24 metres. If the width of the outer courtyard is less than 2.4 metres, then it shall be treated as a notch and the provisions of outer courtyard shall not apply. However, if the depth of outer courtyard is more than the width, the provisions of Rule 55 (3) shall apply for the open spaces to be left between the wings.\n(c) Outer Courtyard.\n(9) Joint open air space.\n(b) If such interior or exterior open air space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in sub-rules (5) and (6) of Rule 56 abutting on such open air space.\n(c) If such interior or exterior open air space is jointly owned by more than one person, then its width shall also be as specified in Rules 59 provided that every such person agrees in writing to allow his portion of such joint open air space to be used for the benefit of every building abutting on such joint open air space and provided he sends such written consent to the Authority for record. Such common open air space shall thenceforth be treated as a permanently open air space required for the purposes of these rules. No boundary wall between such joint open air space shall be erected or raised to a height of more than 2.0 metres.",
"footnote": "",
"is_definition": false,
"sort_order": 51
},
{
"number": "57",
"title": "57. Open spaces for other occupancies.",
"chapter": null,
"content": "(a) Educational Buildings. - Except for nursery schools, the open spaces around the building shall be not less than 6 metres;\n(a) Educational Buildings.\n(b) Institutional Buildings. - The open spaces around the building shall be not less than 6 metres; and\n(b) Institutional Buildings.\n(c) Assembly Buildings. - The open space at front shall be not less than 12 metres and the other spaces around the building shall be not less than 6 metres.\n(c) Assembly Buildings.\nNote. - However if assembly buildings are permitted in purely residential zones, the open spaces around the building shall not be less than 12 metres.\nNote.\n(d) Business Mercantile and Storage Buildings. - The open spaces around the buildings shall be not less than 4.5 metres. Where these are situated in purely residential zone or residential with shops line zone, the open spaces may be relaxed.\n(d) Business Mercantile and Storage Buildings.\n(e) Industrial Buildings. - The open spaces around the buildings shall be not less than 4.5 metres for heights up to 16 metres with an increase of the open spaces of 0.25 metres for every increase of 1 metre or fraction thereof in height above 16 metres.\n(e) Industrial Buildings.\n(f) Hazardous Occupancies. - The open spaces around the building shall be as specified for industrial buildings [ See clause (e) above],\n(f) Hazardous Occupancies.",
"footnote": "",
"is_definition": false,
"sort_order": 52
},
{
"number": "58",
"title": "58. Projections.",
"chapter": null,
"content": "(1) Projection into open spaces.\n(a) Cornice, roof or weather shade not more than 0.75 metre wide;\n(b) Sunshade over windows/ventilators or other openings not more than 0.75 metre wide;\n(c) Canopy at level not lower than lintel level of the first floor, but not to be used as a sit out with clearance of 1.5 metres between the plot boundary and the canopy;\n[(d) Projected balcony at higher floors of width not more than 1.20 metre:\n(e) Projecting rooms balconies [ See clause (d)] at alternate floors such that rooms of the lower two floors get light and air and the projection being not more than the height of the storey immediately below.\n(2) Accessory Building.\n(a) in existing buildings, sanitary block 2.4 metres in height subject to a maximum of 4 square metres in the rear open space at a distance of 1.5 metres from the rear boundary may be permitted.\n(b) Parking lock up garages not exceeding 2.6 metres from plinth level in height and an area not exceeding 20 square metres shall be permitted in the side or rear open spaces at a distance of 7.5 metres from any road line or the front boundary of the plot:\n(c) Suction tank and pump room each up to 2.5 square metre in area.\n(3) Projections into street.\n(4) Porticoes in existing developed area.\n(a) porticoes may be allowed on such roads leaving a minimum clear space of 19 meters between kerbs;\n(b) it shall not be less than 3 meters wide;\n(c) nothing shall be allowed to be constructed on the portion which shall be used as an open terrace;\n(d) nothing shall be allowed to project beyond the line or arcades; and\n(e) the space under the portico shall be paved and channelled according to the directions of the authority.\n(5) Sunshades over windows and ventilators.\n(a) No sun-shade shall be permitted over the road or over any drain or over any portion outside the boundaries of the site below a height of 2.8 meters from the road level;\n(b) Sunshades provided above a height of 2.8 meters from the ground level shall be permitted to project up to a maximum width of 60 centimetres of the road over which they project exceeds 9 meters in width; and\n(c) No Sunshade shall be permitted on roads less than 9 meters width or on roads having no footpath.",
"footnote": "",
"is_definition": false,
"sort_order": 53
},
{
"number": "59",
"title": "59. Limitation to open space.",
"chapter": null,
"content": "(1) Safeguard against reduction of open spaces.\n(2) Additions or Extensions to a building.",
"footnote": "",
"is_definition": false,
"sort_order": 54
},
{
"number": "60",
"title": "60. Group housing.",
"chapter": null,
"content": "(1) Multi-storied blocks to be preferred.\n(2) Access to dwelling in low-cost housing.\n(3) Minimum size of plots.\n(4) No limitation on floors and height.\nTable 6\nTable 6\nFloor area Ratio and coverage for group housing\nFloor area Ratio and coverage for group housing\n[Rule 60(4)]\nS.No.\nS.No.\nGross residential density Persons/Hectare\nGross residential density Persons/Hectare\nMaximum coverage in per cent.\nMaximum coverage in per cent.\nFloor area ratio\nFloor area ratio\n1.\n125\n25\n0.75\n2.\n250\n30\n1.25\n3.\n425\n33 ½\n1.50\n4.\n500\n35\n1.75\n5.\n625\n35\n2.00\nNote. - The coverage shall be calculated on the basis of the whole area reserved for group housing after deducting\nNote.\n(i) the area of any highway, any road upto 25 metres and major residential road of 18 metres wide road around the Group Housing Area (residential street, loop street, cul-de-sac, service lanes and footpaths shall not be deducted);\n(ii) the area of school (excluding sites for Nursery Schools) and other community facilities within the Group Housing Area; and\n(iii) the open space except playgrounds and toilets of local nature.\n(iii) Area and Height Limitations\n(iii) Area and Height Limitations",
"footnote": "",
"is_definition": false,
"sort_order": 55
},
{
"number": "61",
"title": "61. Floor Area Ratio.",
"chapter": null,
"content": "Table 7\nTable 7\nF.A.R. for different use group\nF.A.R. for different use group\n[Rule 61]\nS. No.\nUse Group\nRemarks\n1.\nResidential\nF.A.R. and Density may be adopted as provided in the\n\t\t\t\tDevelopment Plans of respective places.\n2.\nBusiness Commercial\n1.00 1.20 1.50 3.00\nNeighbourhood shopping centre. Sub-district shopping\n\t\t\t\tcentre/District shopping centre. Central Business district\n\t\t\t\tarea Office areas.\n3.\nEducation\n1.00\n4.\nInstitutional\n1.50\n5.\nAssembly\n1.50\n6.\nIndustrial\n0.60 0.55 0.50 0.45 0.40 0.30\nUpto to 250 square metres 250 to 300 square metres 300\n\t\t\t\tsquare metres to 0.2 hectare. 0.8 to 1.2 hectare 1.2 to 2.8\n\t\t\t\thectare above 2.8 hectares.\n[Note 1.] - In case where the owner of the plot surrenders and vests in the Authority a portion of the plot for the prescribed road width of a public road without claiming any compensation he shall be allowed floor area ratio calculated by adding twice the area as surrendered by him to the remaining area of his plot.\n[Note 1.]\n[(2) In case of redevelopment of Jhuggi-Jhopadi area, an additional FAR upto a limit of 0.50 may be allowed in addition to the permissible F.A.R. that area, provided that the permissibility of building height is maintained.\n(3) For plots from 200 Sq.m. to 500 Sq.m. only one servant quarter and for plots above 500 Sq.m. 2 servant quarters shall be permitted in addition to the F.A.R. stipulated. The size of one servant quarter shall not be more than 20 Sq.m. which shall include one dwelling room having floor area not less than 11 Sq.m. and the remaining 9 Sq.m. may be used for cooking verandah and one toilet.\n(4) For Flatted Development (i.e., residential units in flats) and Group Housing of four or more floors, on plots of 425 Sq. m. or more in area, if the covered parking with a height of 2.4 meter is provided within the permissible ground coverage, such area of parking shall not be counted for the purpose of Floor Area Ratio and permissible height calculations.\n(5) In case of redevelopment of areas in the old part of any city/town (after redevelopment plan having been prepared) the old and dilapidated structures may be reconstructed and if needed, an additional F.A.R. upto an extent of 0.25 shall be sanctioned in addition to normal prescribed F.A.R. of the area subject to the height restrictions of buildings in that area :\nProvided that no such benefit shall be given if a redevelopment plan for the area has not been prepared.]\n[6. The following relaxation of FAR shall be allowed to establish Software Units under information Technology in different cities of the State\n(a) Relaxation up to 25% in existing FAR in Indore, Bhopal, Gwalior and Jabalpur.\n(b) There shall be no restriction on FAR in rest of the towns of the State for Software Units.\nThe above relaxation shall be allowed subject to following conditions:",
"footnote": "",
"is_definition": false,
"sort_order": 56
},
{
"number": "1",
"title": "1. Proposed buildings shall be constructed on 20,000 Square Feet of land.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 57
},
{
"number": "2",
"title": "2. In case of old buildings, the Software Unit should have been in existence for more than one year.",
"chapter": null,
"content": "3. 75% of the total built-up area of the proposed building shall be used for its units and remaining part should be utilised for ancillary purposes.",
"footnote": "",
"is_definition": false,
"sort_order": 58
},
{
"number": "4",
"title": "4. The above relaxation shall be given only in existing FAR stipulated in rules. The provisions in rules for Ground Coverage. M.O.S. and Height of building shall remain unchanged.]",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 59
},
{
"number": "62",
"title": "62. Height Limit.",
"chapter": null,
"content": "(a) the maximum height of building shall not exceed one and half times the width of road abutting plus the front open spaces;\n(b) if a building abuts on two or more streets of different widths, the building shall be deemed to face such street as has the greater width and the height of the building shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres along the narrower street subject to conformity of Rule 56; and\n(c) for building in vicinity of aerodromes, the maximum height of such buildings shall be as given in Table 8 :\nTable 8\nTable 8\nHeight Restrictions near Aerodromes\nHeight Restrictions near Aerodromes\n[Rule 62 (c)]\nS. No.\nLimits of distance from the aerodrome reference point of\n\t\t\t\t\tbuildings, structures or installations measured horizontally.\nPermissible height of building, structures or installation\n\t\t\t\t\tfrom aerodrome reference point.\n1.\nInternational Civil Airports and their alternates\n(a) Between 8534 Meters and 22224 M\n152 Meters\n(b) Between 7315 Meters and 8534 M\n122 Meters\n(c) Between 6096 Meters and 7315 M\n91 Meters\n(d) Between 4877 Meters and 6096 M\n61 Meters\n(e) Between 4267 Meters and 4877 M\n49 Meters\n(f) Between 3658 Meters and 4267 M\n37 Meters\n(g) Between 3048 Meters and 3658 M\n24 Meters\n(h) Between 2438 Meters and 3048 M\n12 Meters\n(i) Between 2438 Meters and less\nNil, except with the prior concurrence of the Local Aerodrome\n\t\t\t\t\tAuthorities.\n2.\nOther Civil Airports and Civil Aerodromes\n(a) Between 7925 metres and 2224 m\n152 Meters\n(b) Between 6709 metres and 7925 m\n122 Meters\n(c) Between 5486 metres and 6709 m\n91 Meters\n(d) Between 4267 metres and 5486 m\n61 Meters\n(e) Between 3658 metres and 4267 m\n49 Meters\n(f) Between 3043 metres and 3658 m\n37 Meters\n(g) Between 2438 metres and 3048 m\n24 Meters\n(h) Between 1829 metres and 2438 m\n12 Meters\n(i) Between 1829 metres and less\nNil, except with the prior concurrence of the Local Aerodrome\n\t\t\t\t\tAuthority.\nNote 1. - For serial Nos. (g), (h) and (i) no trees should be planted within the limits of the distances indicated.\nNote 1.\nNote 2. - Irrespective of their distance from the aerodrome (that is beyond 22224 Meters of the aerodrome/aerodrome reference point) not radio masts or such similar type of installations exceeding 152 Meters in height should be erected without prior permission to the concerned civil aviation authority.\nNote 2.\nNote 3. - No building, structure or installation exceeding the height indicated in 1 and 2 of the table should be permitted without prior consultation with the local aerodrome authority.\nNote 3.\nNote 4. - The location of a slaughter house/butcher house and other areas for activities like depositing of garbage in garbage dumps which would generate the collection of high flying birds like eagles/hawks, etc, shall not be permitted within a radius of 10 kilometres from aerodrome reference points.\nNote 4.",
"footnote": "",
"is_definition": false,
"sort_order": 60
},
{
"number": "63",
"title": "63. Height exceptions-Roof Structures.",
"chapter": null,
"content": "(a) roof tanks and their supports;\n(b) Ventilating, air-conditioning, lift rooms and similar service equipment;\n(c) roof structure other than plant-houses; and\n(d) chimneys and parapet walls and architectural features not exceeding 1 meter in height.",
"footnote": "",
"is_definition": false,
"sort_order": 61
},
{
"number": "64",
"title": "64. Planting of trees.",
"chapter": null,
"content": "(iv) Requirements of parts of building\n(iv) Requirements of parts of building",
"footnote": "",
"is_definition": false,
"sort_order": 62
},
{
"number": "65",
"title": "65. Plinth.",
"chapter": null,
"content": "(1) Main Building.\n(2) Interior courtyard.",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
{
"number": "66",
"title": "66. Habitable rooms.",
"chapter": null,
"content": "(1) Height.\n(a) Educational building. - Ceiling height 3.6 metres for all regions; in cold region 3 metres.\n(a) Educational building.\n(b) Industrial building. - Ceiling height 3.6 metres except when air-conditioned 3 metre (Factory Act, 1948 and rules thereunder shall govern such height where applicable).\n(b) Industrial building.\n(3) Size.\n(ii) However in the case of special housing schemes for Economically Weaker Section of Society, low income group housing, slum clearance scheme or industrial labour housing schemes, the norms for the size of the rooms shall be as follows:-\n(a) A single room tenament shall consist of a room not less than 9.5 square metres in area with a minimum width of 2.4 metres and a multipurpose space of area not less than 4.0 square metres, with a minimum width of 1.5 metres;\n(b) In the case of double room tenament there shall be a living room not less than 9.5 square metres in area and another room not less than 7.5 square metres in area.",
"footnote": "",
"is_definition": false,
"sort_order": 64
},
{
"number": "67",
"title": "67. Kitchen.",
"chapter": null,
"content": "(1) Height.\n(2) Size.\n(3) Other requirements.\n(a) unless separately provided in a pantry, means for the washing of kitchen utensils which shall lead directly or through a sink to a grated and trapped connection to the waste pipe;\n(b) an impermeable floor;\n(c) a flue, if found necessary; and\n(d) a window or ventilator or opening of size not less than as specified in note 3 sub-rule (3) of Rule 80.",
"footnote": "",
"is_definition": false,
"sort_order": 65
},
{
"number": "68",
"title": "68. Bathroom and Water Closets.",
"chapter": null,
"content": "(1) Height.\n(2) Size.\n(ii) In case of Special Housing Scheme referred to in Rule 66 (3) (ii), the sizes of bathrooms/water closets shall be as follows:-\n(a) independent water closet-1.1 m X 0.9 metre\n(b) independent bathroom-1.3 m X 1.1 metres\n(c) combined bathroom and closet-2.0 square metres with minimum width of 1.1 metres.\n(d) Water closet with wash basin-1.3 square metres.\n(3) Other requirements.\n(a) be so situated that at least one of its walls shall open to external air;\n(b) not be directly over or under any room other than another water-closet, washing place, bath or terrace, unless it has a water tight floor;\n(c) have the platform or seat made of watertight non-absorbent material;\n(d) be enclosed by wall or partitions and the surface of every such wall or partition shall be finished with a smooth impervious material to a height of not less than 1 metre above the floor of such a room;\n(e) be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards verandah or any other room; and\n(f) have a window or ventilator, opening to a shaft or open space, of area not less than 3 square metres with side not less than 0.3 metre.",
"footnote": "",
"is_definition": false,
"sort_order": 66
},
{
"number": "69",
"title": "69. Ledge or Tand/Loft.",
"chapter": null,
"content": "(1) Height.\n(2) Size.\n(3) Loft.",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
{
"number": "70",
"title": "70. Mezzanine (Entresol) Floor.",
"chapter": null,
"content": "(1) Height.\n(2) Size.\n(3) Other requirements.\n(a) it conforms to the standards of living rooms as regards lighting and ventilation in case the size of mezzanine floor is 9.5 square metres or more;\n(b) it is so constructed as not to interfere, under any circumstances, with the ventilation of the space over and under it;\n(c) such mezzanine floor is not sub-divided into smaller compartments;\n(d) such mezzanine floor or any part of it shall not be used as a kitchen; and\n(e) in no case a mezzanine floor shall be closed so as to make it liable to be converted into unventilated compartments.",
"footnote": "",
"is_definition": false,
"sort_order": 68
},
{
"number": "71",
"title": "71. Store room.",
"chapter": null,
"content": "(1) Height.\n(2) Size.",
"footnote": "",
"is_definition": false,
"sort_order": 69
},
{
"number": "72",
"title": "72. Garage.",
"chapter": null,
"content": "(1) Height.\n(2) Size.\n(a) Private Garage. - 2.5 metres X 5.0 metres minimum :\n(a) Private Garage.\n(b) Public Garage. - Based on the number of vehicles parked etc. ( See Rule 82-parking space).\n(b) Public Garage.",
"footnote": "",
"is_definition": false,
"sort_order": 70
},
{
"number": "73",
"title": "73. Basement.",
"chapter": null,
"content": "(a) Storage or house-hold or other goods of ordinarily combustible materials;\n(b) Strong rooms, bank cellars;\n(c) Air-conditioning equipment and other machine used for services and utilities of the building; and\n(d) Parking spaces.\n(a) Every basement shall be in every part at least 2.4 metres in height from the floor to the underside of the roof slab or ceiling;\n(b) adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to these rules. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems, or the like;\n(c) the minimum height of the ceiling of any basement shall be 0.9 metre and maximum of 1.2 metres above the average surrounding ground level;\n(d) adequate arrangements shall be made such that surface drainage does not enter the basement;\n(e) the walls and floors of the basement shall be watertight and be so designed that the effect of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given; and\n(f) the access to the basement shall be separate from the main and alternate staircase providing access and exit from higher floors. Where the staircase is continuous in case of building served by more than one staircase the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors. Open ramps shall be permitted if they are constructed within the building line subject to the provision of clause (d).\n(a) the minimum frontage of the plot shall be 21 metres and the minimum average depth be 30 metres and Such plot abuts 18 metres wide road; and\n(b) they shall be allowed only in detached buildings.",
"footnote": "",
"is_definition": false,
"sort_order": 71
},
{
"number": "74",
"title": "74. Parapet.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
{
"number": "75",
"title": "75. Boundary Wall.",
"chapter": null,
"content": "(a) Except with the special permission of the Authority, the maximum height of the compound wall shall be 1.5 metres above the centre line of the front street. Compound wall up to 2.4 metres height may be permitted if the top 0.9 metre is of open type construction of a design to be approved by the Authority;\n(b) the rear and side compound walls shall not have a height more than 3 metres above the central line of the service road in case it exists, otherwise 2 metres shall be measured above the central line of the front street. In case of a corner plot the height of the boundary wall abutting on the side road shall also not be more than 1 5 metres till the Court yard width starts; and\n(c) the provisions of (a) and (b) are not applicable to boundary walls of jails, electric sub-stations, transformer stations, institutional buildings like, sanatoria, hospitals, industrial buildings like workshops, factories and educational buildings like schools, colleges, including the hostels, and other uses of public utility undertaking, where height up to 2.4 metres may be permitted by the Authority.",
"footnote": "",
"is_definition": false,
"sort_order": 73
},
{
"number": "76",
"title": "76. Septic Tanks.",
"chapter": null,
"content": "(i) Location of Septic Tanks and Sub-Surface absorption systems. - A sub-soil dispersion system shall not be within 18 metres from any source of drinking water, such as well, to mitigate the possibility of bacterial pollution of water supply. It shall also be as removed from the nearest habitable building as economically feasible but not within 2 metres thereof so that there is no damage to the structures.\nLocation of Septic Tanks and Sub-Surface absorption systems.\n(ii) Other Requirements :-\n(a) Dimensions of septic tanks-Septic tanks shall have minimum width of 75 centimetres minimum depth of one metre below the water level and a minimum liquid capacity of one cubic metre. Length of tanks shall be 2 to 4 times the width;\n(b) Septic tanks may be constructed of brick work, stone masonry concrete or other suitably materials as, approved by the Authority;\n(c) under no circumstances should effluent from a septic tank be allowed into an open channel drain or body of water without adequate treatment;\n(d) minimum nominal diameter of pipe shall be 100 millimetres. Further, at junctions of pipes in manholes, direction of flow from a branch connection should not make an angle exceeding 45 degrees with the direction of flow in the main pipe;\n(e) the gradients of land drains, under-drainage as well as the bottom of dispersion trenches and soakways should be between 1:300 and 1:400;\n(f) every septic tank shall be provided with ventilating pipe of at least 50 millimeter diameter. The top of the pipe shall be provided with a suitable cage of mosquito proof wire mesh. The ventilating pipe shall extend to a height which would cause no smell nuisance to any building in the area. Generally, the ventilating pipe may extend to a height of about 2 metres when the septic tank is at least 15 metres away from the nearest building and to a height of 2 metres above the top of the building when it is located closer than 15 metres;\n(g) when the disposal of septic tank effluent is to seepage pit, the seepage pit may be of any suitable shape with the least cross-sectional dimension of 90 centimetres and not less than 100 centimetres in depth below the invert level of the inlet pipe. The pit may be lined with stone, brick or concrete blocks with dry open joints which should be backed with at least 7.5 centimetres of clean coarse aggregate. The lining above the inlet level should be finished with mortar. In the case of pits of large dimensions, the top portion may be narrowed to reduce the size of the reinforced cement concrete cover slabs. Where no lining is used, specially near trees, the entire pit should be filled with loose stones. A masonry ring may be constructed at the top of the pit to prevent damage by flooding of the pit by surface run off. The inlet pipe may be taken down a depth of 90 centimetres from the top as an anti-mosquito measures; and\n(h) when the disposal of septic tank effluent is to a dispersion trench, the dispersion trench shall be 50 to 100 centimetres deep and 30 to 100 centimetres wide excavated to a slight gradient and shall be provided with 10 to 25 centimetres of washed gravel or crushed stones. Open jointed pipes placed inside the trench shall be made of unglazed earthenware clay or concrete and shall have minimum internal diameter of 75 to 100 millimeters. Each dispersion trench should not be longer than 30 metres and trenches should not be placed closer than 1.8 metres.",
"footnote": "",
"is_definition": false,
"sort_order": 74
},
{
"number": "77",
"title": "77. Staircase.",
"chapter": null,
"content": "(2) Minimum Width.\n(i)\nResidential buildings (dwellings)\n0.85 metres.\nNote . - For new housing with two storeys the\n\t\t\t\tminimum width shall be 0.75 metre.\nNote\n(ii)\nResidential hotel buildings\n1.5 metres.\n(iii)\nAssembly buildings like auditorium, theatres and cinemas\n1.5 metres.\n(iv)\nEducational buildings-upto 24 m in height\n1.5 metres.\nmore than 24 m in height.\n2.0 metres.\n(v)\nInstitutional buildings-upto 10 beds\n1.5 metres.\nmore than 10\n\t\t\t\tbeds\n2.0 metres.\n(vi)\nAll other buildings\n1.5 metres.\n(4) Minimum Tread.\n(5) Maximum Riser.\n(6) Head Room.",
"footnote": "",
"is_definition": false,
"sort_order": 75
},
{
"number": "78",
"title": "78. Roofs.",
"chapter": null,
"content": "(v) Lighting and Ventilation\n(v) Lighting and Ventilation",
"footnote": "",
"is_definition": false,
"sort_order": 76
},
{
"number": "79",
"title": "79. Lighting and Ventilation of Rooms.",
"chapter": null,
"content": "Note 1. - If a window is partly fixed, the openable area shall be counted.\nNote 1.\nNote 2. - No portion of a room shall be assumed to be lighted, if it is more than 7.5 metres away from the opening assumed for lighting that portion.\nNote 2.\nNote 3. - Area of openings as given in this sub-rule shall be increased by 25 per cent in case of a kitchen.\nNote 3.\n(vi) Lifts\n(vi) Lifts\n[80. Provision of Lifts.\n(vii) Parking Space\n(vii) Parking Space\n[81. Parking Space.\n(viii) Exits\n(viii) Exits",
"footnote": "",
"is_definition": false,
"sort_order": 77
},
{
"number": "82",
"title": "82. Exit Requirements.",
"chapter": null,
"content": "(1) General.\n(a) every building meant for human occupancy shall be provided with exits sufficient to permit safe escape of occupants in case of fire or other emergency;\n(b) in every building exits shall comply with the minimum requirements of this part except those not accessible for general public use;\n(c) all exits shall be free of obstruction;\n(d) no building shall be altered so as to reduce the number, width or protection of exits to less than that required;\n(e) exits shall be clearly visible and the routes to reach the exit shall be clearly marked and sign posted to guide the population of floor concerned;\n(f) all exit ways shall be properly illuminated;\n(g) fire fighting equipment, where provided along exits, shall be suitably located and clearly marked but must not obstruct the exit way and yet there should be clear indication about its location from either side of the exit way;\n(h) alarm devices shall be installed to ensure prompt evacuation of persons inside through the exits;\n(i) all exits shall provide continuous means of access to the exterior of a building or to an exterior open space leading to a street; and\n(j) exits shall be so arranged that they may be reached without passing through another occupied unit, except in the case of residential buildings.\n(2) Types of Exits.\n(b) Lifts and escalators shall not be considered as exits.\n(3) Number and size of Exits.\n(i) Arrangement of Exit. - Exits shall be so located that the travel distance on the floor shall not exceed 22.5 metres for residential, educational, institutional and hazardous occupancies and 30 metres for assembly, business, mercantile, industrial and storage occupancies. Whenever more than one exit is required for a floor of a building, exits shall be placed as remote from each other as possible. All the exits shall be accessible from the entire floor area at all floor levels.\n(i) Arrangement of Exit.\n(ii) Occupant Load. - The population in rooms, areas of floors shall be calculated based on the occupant load given in Table 9 :\n(ii) Occupant Load.\nTable 9\nTable 9\nOccupant Load\nOccupant Load\n[Rule 82]\nS. No.\nS. No.\nGroup of Occupancy\nGroup of Occupancy\nOccupant load Gross Area* in square metres\n\t\t\t\t\tper person\nOccupant load Gross Area* in square metres\n\t\t\t\t\tper person\n1.\nResidential\n12.5\n2.\nEducational\n4\n3.\nInstitutional\n15#\n4.\nAssembly-\n(a) with fixed or loose seats and dance floor\n0.6$\n(b) without seating facilities including dining rooms\n1.5$\n5.\nMercantile-\n(a) street floor and sales basement\n3\n(b) upper sale floors\n6\n6.\nBusiness and Industrial\n10\n7.\nStorage\n30\n8.\nHazardous\n10\n* The gross area shall mean plinth area or covered area.\n# Occupant load in dormitory portions of homes for the aged, orphanages, insane asylums and the like, where sleeping accommodation is provided, shall be calculated at not less than 7.5 square metres gross area/person.\n$ The gross area shall include, in addition to the main assembly room or space, any occupied connecting room or space in the same storey or in the storeys above or below, where entrance is common to such rooms and spaces and they are available for use by the occupants of the assembly place. No deductions shall be made in the gross area for corridors, closets or other sub-divisions, and area shall include all space serving the particular assembly occupancy.\n(iii) Capacity of Exits. - The capacity of exits (doors and stairways) indicating the number of persons that could be safely evacuated through a unit exit width of 50 centimetres shall be as given in Table 10 :\n(iii) Capacity of Exits.\nTable 10\nTable 10\n[Rule 82 (3)(iii)]\nS. No.\nS. No.\nGroup of occupancy\nGroup of occupancy\nNumber of occupants\nNumber of occupants\nStairways\nStairways\nDoors\nDoors\n1.\nResidential\n25\n75\n2.\nEducational\n25\n75\n3.\nInstitutional\n25\n75\n4.\nAssembly\n60\n90\n5.\nBusiness\n50\n75\n6.\nMercantile\n50\n75\n7.\nIndustrial\n50\n75\n8.\nStorage\n50\n75\n9.\nHazardous\n25\n40\n(iv) Number of staircases. - For all other buildings excepting single and multi-family dwellings below 15 metres in height, there shall be a minimum of two stairways and one of them shall be an enclosed stairway and the other shall be on the external wall of building and shall open directly to the exterior, interior open space or to any open place of safety.\n(iv) Number of staircases.\n(v) Minimum width for stairways. - Notwithstanding the detailed provision for exits as per clause (i) to (iii) above the provisions of sub-rule (2) of Rule 77 will govern the width of stairways.\n(v) Minimum width for stairways.\n(4) Other requirements of individual exits.\n(I) Doorways\n(a) Every exit doorway shall open into an enclosed stairway, a horizontal exit, or a corridor or passage way providing continuous and protected means of egress.\n(b) No exit doorway shall be less than 100 centimetres in width. Doorway, shall be not less than 200 centimetres in height. Doorways for bathrooms, water closet or stores shall not be less than 75 centimetres.\n(c) Exit doorways shall, as far as possible, open outwards, that is, away from the room but shall not obstruct the travel along any exit. No door, when opened, shall reduce the required width of stairway or landing to less than 90 centimetres over head or sliding doors shall not be installed.\n(d) Exit door shall not open immediately upon a flight of stairs; a landing equal to at least the width of the door shall be provided in the stairway at each doorway level of landing shall be the same as that of the floor which it serves.\n(e) Exit doorways shall be openable from the side which they serve without the use of a key.\n(II) Revolving Doors\n(a) Revolving doors shall not be used as required exits except in residential, business and mercantile occupancies, but shall not constitute more than half the total required door width.\n(b) When revolving doors are considered as required exit way the following assumptions shall be made\n(i) each revolving door shall be credited one half a unit exit width;\n(ii) revolving doors shall not be located at the foot of a stairway. Any stairway served by a revolving door shall discharge through a lobby or foyer.\n(III) Stairways.\n(a) interior stairs shall not be constructed of ordinarily combustible materials throughout.\n(b) interior staircase shall be constructed as a self-contained unit with at least one side adjacent to an external wall. Wherever a building is not identified by clause (ii) of sub-rule (6) of Rule 17 exceeds 10.5 metres in height and is served by a staircase the same shall be of enclosed type.\n(c) A staircase shall not be arranged round a lift shaft unless the latter if entirely enclosed by a material of fire resistance rating as that for type of construction itself. For buildings more than 15 metres in height, the staircase location shall be to the satisfaction of the competent fire Authority as approved by the Government.\n(d) The minimum width of treads shall be governed by sub-rule (4) of Rule 77. The treads shall be constructed and maintained in a manner to prevent slipping.\n(e) The maximum height of riser shall be governed by sub-rule (5) of Rule 77.\n(f) Handrails shall be provided with a minimum height of 90 centimetres from the centre of the tread.\n(g) The minimum headroom in a passage under the landing of a staircase and under the staircase shall be governed by sub-rule (6) of Rule 77.\n(h) No living space, store or other fire risk shall open directly into the staircase.\n(i) External exit door of staircase enclosure at ground level shall open directly to the open spaces or can be reached without passing through any door other than a door provided to form a drought lobby.\n(j) In the case of assembly, institutional residential hotels and business buildings the exit sign with arrow indicating the way to the escape route shall be provided at a height of 0.5 metre from the floor level on the wall and shall be illuminated by electric light connected to corridor circuits. All exits way marking signs should be flush with the wall and so designed that no mechanical damage shall occur to them due to moving of furniture or other heavy equipments. Further all landings of floor shall have floor indication boards indicating the number of floor as defined in Rule 2 (28). The floor indication board shall be placed on the wall immediately facing the flight of stairs and nearest to the landing. It shall be of size not less than 0.5 X 0.5 metre.\n(k) In case of single staircase it shall terminate at the ground floor level and the access to the basement shall be by a separate staircase. Wherever the building is served by more than one staircase one of the staircase may lead to basement level provided the same is separated at ground level by either a ventilated lobby with the discharge points at two different ends or through enclosure.\n(IV) Fire Escape or External Stair\n(a) Fire escapes shall not be taken into account in calculating the evacuation time of a building.\n(b) All fire escape shall be directly connected to the ground.\n(c) Entrance to fire escape shall be separate and remote from the internal staircase.\n(d) The route to fire escape shall be free from obstructions at all times, except a doorway leading to the fire escape which shall have the required fire resistance.\n(e) Fire escape shall be constructed of non-combustible materials.\n(f) Fire escape stairs shall have straight flight not less than 75 centimetres wide with 15 centimetres treads and risers not higher than 19 centimetres. The number of risers shall be limited to 16 per flight.\n(g) Handrails shall be of a height not less than 90 centimetres.\n(V) Spiral Stairs (fire escape).\n(a) The use of spiral staircase shall be limited to low occupant load and to a building of height of 9 metres unless they are connected to platforms, such as balconies and terraces to allow escapes to pause.\n(b) A spiral fire escape shall be not less than 150 centimetres in diameter and shall be designed to give adequate headroom.\n(VI) Roof Exit.\n(VII) Ramps.\n(a) Ramps with a slope of not more than 1 in 40 may be permitted for and shall comply with all the applicable requirements of required stairways as to enclosure, capacity and limiting dimensions, Ramps shall be surfaced with approved non-slipping material.\n(b) The minimum width of the ramps in hospitals shall be 2.25 metres.\n(c) Handrails shall be provided on both side of the ramp.\n(d) Ramps shall lead directly to outside open space at ground level of courtyards or safe place.\n(VIII) Corridors.\n(a) The minimum width of a corridor shall be 1.0 metre.\n(b) For building more than 15 metres in height the interconnecting corridor between staircases shall be provided with at least one smoke stop door across the corridor or enclosed space between the doors in the enclosing walls of any two staircases.\n(IX) Refuge areas.\n(a) For all buildings exceeding 15 metres in height excepting multi-family building, one refuge area on the floor immediately above 18 metres shall be provided.\n(b) Refuge area shall be provided on the external walls as cantilever projections or in any other manner (which will not be covered in floor area ratio) with a minimum area of 15 square metres and to be calculated based on the population on each floor at the rate of 1 square metres per person.\n(X) Fire and Structural Safety and Services\n[82A. Facilities for physically handicapped persons in all Public buildings/Public residence.\n(1) Access Path/Walk way.\n(2) Parking.\n(a) Surface parking for two car spaces shall be provided near entrance for the physically handicapped persons with maximum travels distance of 30.0 meter from building entrance;\n(b) The width of parking bay shall be minimum 3.6 meter ;\n(c) The information stating that the space is reserved for wheel chair users shall be conspicuously displayed;\n(d) Guiding floor material shall be provided or a device which guides visually impaired persons with audible signals or other devices which serves the same purpose shall be provided.\n(3) Building requirements.\n(a) Approach to plinth level;\n(b) Corridor connecting the entrance/exit for the handicapped;\n(c) Stair-ways;\n(d) Lift;\n(e) Toilet;\n(f) Drinking water\n(4) Approach to plinth level.\n(5) Ramped Approach.\n(6) Stepped Approach.\n(7) Exit/Entrance Door.\n(8) Entrance Landing.\n(9) Corridor connecting the entrance/exit for the handicapped.\n(a) Guiding floor materials shall be provided or devices that emit sound to guide visually impaired persons;\n(b) The minimum width shall be 1500 mm ;\n(c) In case there is a difference of level slope ways shall be provided with slope of 1 : 2;\n(d) Handrails shall be provided for ramps/slope ways.\n(10) Stair ways.\n(a) The minimum width shall be 1350 mm;\n(b) Height of the riser shall not be more .than 150 mm. and width of the tread 300 mm. The steps shall not have abrupt (square) nosing;\n(c) Maximum number of risers on a height shall be limited to 12;\n(d) Handrails shall be provided on both sides and shall extend 300 mm. on the top and bottom of each flight of steps.\n(11) Lifts.\nClear internal depth\n:\n1100 mm.\nClear internal width\n:\n2000 mm.\nEntrance door width\n:\n900 mm.\n(a) A handrail not less than 600 mm. long at 1000 mm. above floor level shall be fixed adjacent to the control panel.\n(b) The lift lobby shall be of an inside measurement of 1800 mm. x 1800 mm. or more;\n(c) The time of an automatically closing door should be minimum 5 seconds and the closing speed should not exceed 0.25 Meter per Second;\n(d) The interior of the cage shall be provided with a device that audibly indicate the floor the cage has reached and indicates that the door of the cage for entrance/exit is either open or closed.\n(12) Toilets.\n(a) The minimum size shall be 1500 mm x 1750 mm;\n(b) Minimum clear opening of the door shall be 900 mm. and the door shall swing out;\n(c) Suitable arrangement of vertical/horizontal Handrails with 50 mm. clearance from wall shall be made in the toilet;\n(d) The W. C. seat shall be 500 mm. from the door.\n(13) Drinking Water.\n(14) Designing for Children.\n[83. Fire protection Requirements.\n(b) No high rise building shall be approved unless cleared, in writing by the Fire Authority.\n(c) Every building shall be designed and constructed to ensure fire safety and this shall be done in accordance with Para IV.\n[84. Structural Design.\nFor R.C.C. Construction & Pucca-brick construction\n(i) IS : 1893 - 1986\n(ii) IS : 13920 - 1993 (to be read with IS : 456, IS : 1893)\n(iii) IS : 4326 - 1993 (to be read with IS : 1893)\nFor low-strength masonary or clay mud and blocks\n(iv) IS : 13827 - 1993\n(v) IS : 13828 - 1993\nFor Repair & Strengthening\n(vi) IS : 13935 - 1993]",
"footnote": "",
"is_definition": false,
"sort_order": 78
},
{
"number": "85",
"title": "85. Quality of Materials and Workmanship.",
"chapter": null,
"content": "(2) Quality of materials may be relaxed in LIG Scheme.\n(3) Used Materials.\n(4) Storage of Materials.\n(5) Burrow pits dug in the course of construction.\n(6) Demolition.\n(a) Before commencing any work of demolition, a careful and detailed study shall be made of the structure to be demolished including its surroundings. While working out the plan of demolition, safety of the adjoining structures shall be ensured and a certificate to that effect by the Licensed Technical Personnel shall be produced. The final plan of sequence of operations shall have to be approved by the Authority.\n(b) Before commencing any demolition work, specific permission shall be obtained from the Authority, and shall be pasted prominently at the site.\n(c) If the structure to be demolished is one which may have hidden damage caused by fire, flood, or earthquake, measures necessary to prevent accidental collapse, such as bracing, shoring, and the like shall be provided to the satisfaction of the Authority.\n(d) Prominent danger signs shall be pasted all around the property and all openings giving access to the structures shall be barricaded and closed to all except the workmen. During night, warning light shall be placed on or above all barricades.\n(e) All gas, water, electrically, steam and other service lines shall be shut off outside the property line after notifying the service companies and authorities concerned and obtaining their approval. Any temporary service connections required for the demolition work shall be separately taken and arranged in such a manner as to afford safety to the workmen.\n(f) When work is not in progress, watchman shall be provided to prevent unauthorised entry of the public into the danger zone.\n(g) All necessary safety appliances shall be issued to workers before starting of work.\n(h) Safety distances to ensure the safety of the public shall be clearly marked and indicated by signs. All main roads shall be kept open. Diversions for pedestrians shall be constructed, where necessary for safety.",
"footnote": "",
"is_definition": false,
"sort_order": 79
},
{
"number": "86",
"title": "86. Building Services.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 80
},
{
"number": "87",
"title": "87. Plumbing Services.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 81
},
{
"number": "88",
"title": "88. Requirement of water supply in buildings.",
"chapter": null,
"content": "Table-11\nTable-11\n\"Per Capita\" water requirements for various occupancies/use\n\"Per Capita\" water requirements for various occupancies/use\nSl. No.\nSl. No.\nType of occupancy\nType of occupancy\nConsumption per head per day (in litres)\n\t\t\t\t\tsubject to availability\nConsumption per head per day (in litres)\n\t\t\t\t\tsubject to availability\n1.\nResidential\n(a) in living units\n135\n(b) Hotels with lodging accommodation (per bed)\n180\n2.\nEducational\n(a) Day Schools\n45\n(b) Boarding Schools\n135\n3.\nInstitutional (Medical Hospitals)\n(a) Number of beds not exceeding 100\n340\n3.\nInstitutional (Medical Hospitals)\n(a) Number of beds not exceeding 100\n340\n(b) Number of beds exceeding 100\n450\n(c) Medical quarters and hostels\n135\n4.\nAssembly-Cinema theatres, auditoria and like (Per seat of\n\t\t\t\t\taccommodation)\n15\n5.\nGovernment or Semi/public business\n45\n6.\nMercantile (Commercial)\n(a) Restaurants (per seat)\n70\n(b) other business buildings\n45\n7.\nIndustrial\n(a) Factories where bath rooms are to be provided\n45\n(b) Factories where no bath rooms required to be provided\n30\n8.\nStorage (including warehousing)\n30\n9.\nHazardous\n30\n10.\nIntermediate stations (excluding mail and express stops)\n45 (25)*\n11.\nJunction stations\n70 (45)\n12.\nTerminal stations\n45\n13.\nInternational and Domestic Airports\n70\n* The values in parenthesis are for stations where bathing facilities are not provided.\nNote. - The number of persons for serial Nos. 10 to 13 shall be determined by the average of passengers handled by the station daily, due consideration may be given to the staff and workers likely to use the facilities.\nNote.\nTable-12\nTable-12\nFlushing Storage Capacities subject to availability\nFlushing Storage Capacities subject to availability\nS.No.\nS.No.\nClassification of Building\nClassification of Building\nStorage capacity\nStorage capacity\n1.\nFor tenements having common conveniences\n900 litres net per water closet seat.\n2.\nFor residential premises other than tenements having common\n\t\t\t\t\tconveniences.\n270 litres net for one water closet seat and 180 liters for\n\t\t\t\t\teach additional seat in the same-flat.\n3.\nFor factories and workshops.\n900 litres per water closet and 180 litres per urinal seat.\n4.\nFor cinemas, public assembly halls etc.\n900 litres per water closet seat and 350 litres per urinal\n\t\t\t\t\tseat.\nTable-13\nTable-13\nDomestic Storage Capacities\nDomestic Storage Capacities\nNo.\nNo. of floors\nStorage capacity\nRemarks\nFor premises occupied as tenements with common conveniences.\n1.\nFloor 1 (Ground)\nNil\nProvided no down-take fittings are installed.\n2.\nFloor 2, 3, 4, 5 and upper floors\n500 litres per tenement\nFor premises occupied as Flats or Blocks.\n1.\nFloor 1\nNil\nProvided no down take fittings are installed.\n2.\nFloor 2, 3, 4, 5 and upper floors\n500 litres per tenement\nNote 1. - If the premises are situated at a place higher than the roac level in front of the premises storage at ground level shall be provided on the same lines as on floor 2.\nNote 1.\nNote 2. - The above storage may be permitted to be installed provided that the total domestic storage calculated on the above basis is not less than the storage calculated on the number of downtake fittings according to the scales given below :-\nNote 2.\nDown take taps\n70 litres each\nDown take taps\n135 litres each\nBath-tubs\n200 litres each",
"footnote": "",
"is_definition": false,
"sort_order": 82
},
{
"number": "89",
"title": "89. Requirements of Sanitary fittings.",
"chapter": null,
"content": "Table-14\nTable-14\nSanitation Requirements for shops and Commercial Offices\nSanitation Requirements for shops and Commercial Offices\nS.No.\nS.No.\nFitments\nFitments\nFor Personnel\nFor Personnel\n1.\nWater closet\nOne for every 25 persons or part thereof exceeding 15\n\t\t\t\t\t(including employees and customers).\nFor female personnel 1 for every 15 persons or part thereof\n\t\t\t\t\texceeding 10.\n2.\nDrinking Water Fountain\nOne for every 100 persons with a minimum of one on each\n\t\t\t\t\tfloor.\n3.\nWash Basin\nOne for every 25 persons or part thereof.\n4.\nUrinals\nSame as at serial No. 3 of Table 19.\n5.\nCleaner's Sink\nOne per floor minimum, preferably in or adjacent to sanitary\n\t\t\t\t\trooms.\nNote. - Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. For male-female calculation of ratio 1:1 may be assumed.\nNote.\nTable-15\nTable-15\nSanitation Requirements for hotels\nSanitation Requirements for hotels\nS. No.\nFitments\nFor residential public and staff\nFor public rooms\nFor non-residential staff\nFor males\nFor females\nFor male\nFor female\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closet\n1 per 8 persons omitting occupants of the room with attached\n\t\t\t\twater closet, minimum of 2 in both sexes lodged\n1 per 100 persons upto 400 persons for over 400 add at the\n\t\t\t\trate of 1 per 250 persons or part thereof\n2 for 100 persons up to 200 persons over 200 add at the rate\n\t\t\t\tof 1 per 100 or part thereof\n1 for 1-15 2 for 16-35 3 for 36-65 4 for 66-100\n1 for 1-12 2 for 13-25 3 for 26-40 4 for 41-57\n2.\nAblution taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closet\n\t\t\t\tand urinal.\n3.\nUrinals\n1 for 50 persons or part thereof\nPersons Nil up to 6 1 for 7-20 2 for 21-40 3 for\n\t\t\t\t41-70 4 for 71-100\n4.\nWash basins\n1 per 10 persons omitting the wash basins installed in the\n\t\t\t\troom suites\n1 per water closet and urinal provided\n1 for water closet provided\nPersons 1 for 1-15 2 for 16-35 3 for 36-65 4 for\n\t\t\t\t66-100\nPersons 1 for 1-12 2 for 13-25 3 for 26-40 4 for\n\t\t\t\t41-57 5 for 58-77 6 for 78-100\n5.\nBaths\n1 per 10 persons omitting occupants of the room with bath in\n\t\t\t\tsuite\n6.\nSlop sinks\n1 for 30 bed rooms (one per floor minimum)\n7.\nKitchen sinks\n1 in each kitchen\n1 in each kitchen\n1 in each kitchen\n1 in each kitchen\n1 in each kitchen\nNote. - It may be assumed that the two-thirds of the number are males and one third females.\nNote.\nTable-16\nTable-16\nSanitation requirements for Educational Occupancy\nSanitation requirements for Educational Occupancy\nNo.\nFitments\nNursery Schools\nBoarding Institution\nOther Educational Institutions\nFor Boys\nFor Girls\nFor Boys\nFor Girls\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closet\nOne per 30 pupils or part thereof\nOne per 8 pupils or part thereof\nOne per 6 pupils or part thereof\nOne per 80 pupils or part thereof\nOne per 50 pupils or part thereof\n2.\nAblution Tap\nOne in each water closet\nOne in each water closet\nOne in each water closet\nOne in each water closet\nOne in each water closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity.\n3.\nUrinals\nOne per 25 pupils or part thereof\nOne per 20 pupils or part thereof\n4.\nWash Basin\nOne per 30 pupils or part thereof\nOne per 8 pupils or part thereof\nOne per 60 pupils or part thereof\nOne per 80 pupils or part thereof\nOne per 80 pupils or part thereof\n5.\nBaths\nOne bath sink per 40 pupils\nOne or every 8 pupils or part thereof\nOne for every 6 pupils or part thereof\nNil\nNil\n6.\nDrinking water fountains\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\nOne for every 50 pupils or part thereof\n7.\nCleaners sink\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nNote. - For teaching staff, the schedule of fitments shall be the same as in the case of office buildings (table 19).\nNote.\nTable 17\nTable 17\nSanitation Requirements for Institutional (Medical) occupancy Hospitals\nSanitation Requirements for Institutional (Medical) occupancy Hospitals\nS. No.\nFitments\nHospitals with indoor patient wards\nHospitals with outdoor patient wards\nAdministrative building\nFor males and for females\nFor males\nFor females\nFor male personnel\nFor female personnel\n1\n2\n3\n4\n5\n6\n7\n1.\nWater Closet\nOne for every 8 beds or part thereof\nOne for every 100 persons or part thereof\nTwo for every 100 persons or part thereof\nOne for every 25 persons or part thereof\nOne for every 15 person of part thereof\n2.\nAblution Taps\nOne in each water Closet\nOne in each water Closet\nOne in each water Closet\nOne in each water Closet\nOne in each water Closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closet\n\t\t\t\tand urinals.\n3.\nWash Basins\n2 up to 30 bed add one for every additional 30 beds or part\n\t\t\t\tthereof.\nOne for every 100 persons or part thereof\nOne for every 100 persons or part thereof\nOne for every 25 persons or part thereof\nOne for every 4 persons or part thereof\n4.\nBaths with shower\nOne Bath with shower for every 8 beds or part thereof\n–\n–\nOne on each floor\nOne on each floor\n5.\nBed pan washing sinks\nOne for each ward\n–\n–\n–\n–\n6.\nCleaners sink\nOne for each ward\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\n7.\nKitchen sinks and dish washes (where kitchen is provided)\nOne for each ward\n–\n–\n–\n–\n8.\nUrinals\n–\nOne for every 50 persons or part thereof\n–\n–\nOne up to 20 persons 2-for 21-45 persons 3-for 46-70\n\t\t\t\tperson 4-for 71-100 persons for 101 to 200 persons add at\n\t\t\t\tthe rate of 3 percent For over 200 persons add at the rate of\n\t\t\t\t2.5 percent\nTable 18\nTable 18\nSanitation requirements for Institutional (Medical) Occupancy (Staff Quarters & Hostels)\nSanitation requirements for Institutional (Medical) Occupancy (Staff Quarters & Hostels)\nS. No.\nFitments\nDoctor's Dormitories\nNurses Hostel\nFor male staff\nFor female staff\n1\n2\n3\n4\n5\n1.\nWater closet\nOne for 4 persons\nOne for 4 persons\nOne for 4 persons or part thereof\n2.\nAblution taps\nOne in each water closet\nOne in each water closet\nOne in each water closet\n3.\nWash Basins\nOne for every 8 persons or part thereof\nOne for every 8 persons or part thereof\nOne for every 8 persons or part thereof\n4.\nBaths (with shower)\nOne for 4 persons or part thereof\nOne for 4 persons or part thereof\nOne for 6 persons or part thereof\n5.\nCleaner's sinks\nOne per floor minimum\nOne per floor minimum\nOne per floor minimum\nTable 19\nTable 19\nSanitation Requirements for Governmental and public business occupancies and offices\nSanitation Requirements for Governmental and public business occupancies and offices\nS. No.\nFitments\nFor males personnel\nFor female personnel\n1\n2\n3\n4\n1.\nWater closet\nOne for every 25 persons or part thereof\nOne for every 15 persons or part thereof\n2.\nAblution taps\nOne in each water closet.\nOne in each water closet\nOne water tap with draining arrangement shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand urinals.\n3.\nUrinals\nNil up to 6 persons One for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons For 101\n\t\t\t\tto 200 persons add at the rate of 3 percent. For over 200\n\t\t\t\tpersons add at the rate of 2.5 percent.\n4.\nWash basins\nOne for every 250 persons or part thereof.\n5.\nDrinking water fountains\nOne for every 100 persons with a minimum of one for each\n\t\t\t\tfloor.\n6.\nBaths\nPreferably one on each floor\n7.\nCleaners Sinks\nOne per floor minimum preferably in or adjacent to sanitary\n\t\t\t\trooms\nTable - 20\nTable - 20\nSanitation requirements for residences\nSanitation requirements for residences\nS. No.\nFitments\nDwelling with individual conveniences\nDwelling without individual Conveniences\n(1)\n(2)\n(3)\n(4)\n1.\nBath Rooms\n1 provided with water tap\n1 for every three tenements\n2.\nWater closet\n1\n1 for every three tenements\n3.\nSink (or NAHANI) in the floor\n1\n4.\nWater Tap\n1\n1 with draining arrangements in each tenement in common bath\n\t\t\t\trooms and common water closets\nNote. - Where only one water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.\nNote.\nTable 21\nTable 21\nSanitation Requirements for Assembly Occupancy Buildings (Cinema, Theatres and Auditoria)\nSanitation Requirements for Assembly Occupancy Buildings (Cinema, Theatres and Auditoria)\nS. No.\nFitments\nFor public\nFor staff\nMale\nFemale\nMale\nFemale\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n1.\nWater closets\n1 per 100 persons up to 400 persons.\n3 per 100 persons up to 200 persons.\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\nFor over 400 persons, add at the rate of 1 per 250 persons or\n\t\t\t\tpart thereof.\nFor over 200 persons add at the rate of 2 per 100 persons or\n\t\t\t\tpart thereof.\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand urinals.\n3.\nUrinals\n1 for 50 persons or part thereof\nNil up to 6 persons. 1 for 7-20 persons. 2 for 21-45\n\t\t\t\tpersons.\n4.\nWash basins\n1 for every 200 persons or part thereof.\n1 for every 200 persons part thereof.\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n5.\nDrinking water Fountains\n1 for 100 persons or part thereof\nNote. - It may be assumed that two-thirds of the number are males and one-third females.\nNote.\nTable-22\nTable-22\nSanitation Requirements for Assembly Occupancy Buildings (Art Galleries, Libraries and Museums)\nSanitation Requirements for Assembly Occupancy Buildings (Art Galleries, Libraries and Museums)\nS. No.\nFitments\nFor public\nFor staff\nMale\nFemale\nMale\nFemale\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n1.\nWater closets\n1 per 200 persons up to 400 persons. For over 400 persons, add\n\t\t\t\tat the rate of 1 per 250 person or part thereof.\n1 per 100 persons up to 200 persons. For over 200 persons, add\n\t\t\t\tat the rate of 1 per 150 person or part thereof.\n1 for 1-15 persons 2 for 16-35 persons\n1 for 1-12 persons 2 for 13-25 persons\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet.\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 per sons or part thereof in the vicinity of water\n\t\t\t\tclosets and urinals.\n3.\nUrinals\n1 for 50 persons\nNil up to 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\tperson\n4.\nWash basins\n1 for every 200 persons or part thereof. For over 400 persons\n\t\t\t\tadd at the rate of 1 per 250 persons or part thereof.\n1 for every 200 persons or part thereof. For over 200 persons\n\t\t\t\tadd at the rate of 1 per 150 persons or part thereof.\n1 for 1-15 persons 2 for 16-25 persons\n1 for 1-12 persons 2 for 13-25 persons\n5.\nCleaners Sinks\n1 per floor minimum.\nNote. - It may be assumed that two-thirds of the number are males and one-third females.\nNote.\nTable-23\nTable-23\nSanitation Requirements for Restaurants\nSanitation Requirements for Restaurants\nS. No.\nFitments\nFor public\nFor staff\nMale\nFemale\nMale\nFemale\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n1.\nWater closets\n1 for 50 seats upto 200 seats. For over 200 seats add at\n\t\t\t\tthe rate of one per 100 seats or part thereof.\n1 for 50 seats upto 200 seats. For over 200 seats, add at\n\t\t\t\tthe rate of one per 100 seats or part thereof.\n1 for 1-15 persons. 2 for 16-35 persons 3 for 36-65\n\t\t\t\tpersons 4 for 66-100 persons\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t78-100 persons\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet\n1 in each water closet\n1 in each water closet.\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand urinals.\n3.\nUrinals\nOne per 50 seats.\nNil upto 6 persons 1 for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons\n4.\nWash basins\n1 for every water closet provided.\n5.\nKitchen sinks and dish washer\n1 in each kitchen.\n6.\nStop or service sink.\n1 in the restaurant.\nNote. - It may be assumed that two-thirds of the number are males and one-third females.\nNote.\nTable - 24\nTable - 24\nSanitation Requirements for Factories\nSanitation Requirements for Factories\nS. No.\nFitments\nFor Male personnel\nFor Female personnel\n(1)\n(2)\n(3)\n(4)\n1.\nWater closets\n1 for 1-15 persons 2 for 16-35 persons 3 for 36-65\n\t\t\t\tpersons 4 for 66-100 persons For 101 to 200 persons, add at\n\t\t\t\tthe rate of 3 percent. For over 200 persons and at the rate of\n\t\t\t\t2.5 percent\n1 for 1-12 persons 2 for 13-25 persons 3 for 26-40\n\t\t\t\tpersons 4 for 41-57 persons 5 for 58-77 persons 6 for\n\t\t\t\t78-100 persons For 101 to 200 persons, add at the rate of 5\n\t\t\t\tpercent. For over 200 persons add at the rate of 4 percent.\n2.\nAblution Taps\n1 in each water closet\n1 in each water closet.\nOne water tap with draining arrangements shall be provided for\n\t\t\t\tevery 50 persons or part thereof in the vicinity of water closets\n\t\t\t\tand in urinals.\n3.\nUrinals\nNil up to 6 persons. 1 for 7-20 persons 2 for 21-45\n\t\t\t\tpersons 3 for 46-70 persons 4 for 71-100 persons For 101\n\t\t\t\tto 200 persons add at the rate of 3 percent. For over 200\n\t\t\t\tpersons add at the rate of 2.5 percent.\n4.\nWashing taps with draining arrangements\n1 for every 25 persons or part thereof.\n1 for every 25 persons or part thereof.\n5.\nDrinking water Fountains\n1 for every 100 persons with a minimum of one on each floor.\n6.\nBaths (preferably showers)\nAs required for particular trades or occupations.\nNote. - For many trades of a dirty or dangerous character, more extensive provisions are required.\nNote.\nTable - 25\nTable - 25\nSanitary Requirements for Large Stations and Airports\nSanitary Requirements for Large Stations and Airports\nSl.No.\nPlace\nWC for Males\nWC for female\nUrinals for Males only\n(1)\n(2)\n(3)\n(4)\n(5)\n1.\nJunction station intermediate stations and bus stations.\n3 for first 1000 persons and 1 for every subsequent 1000\n\t\t\t\tpersons or part there of.\n4 for first 1000 persons and 1 for every additional 1000\n\t\t\t\tpersons or part thereof.\n4 for every 1000 persons and 1 for a very additional 1000\n\t\t\t\tpersons or part thereof.\n2.\nTerminal stations and bus terminals\n4 for first 1000 persons and 1 for every subsequent 1000\n\t\t\t\tpersons or part thereof.\n5 for first 1000 persons and 1 for every subsequent 2000\n\t\t\t\tpersons or part thereof.\n6 for first 1000 persons and 1 for every additional 1000\n\t\t\t\tpersons or part thereof.\n3.\nDomestic Airports, Min.\nfor 200 persons\nfor 400 persons\nfor 600 persons\nfor 800 persons\nfor 1000 persons\n2*\n5\n9\n12\n16\n18\n4*\n8\n15\n20\n26\n29\n2*\n6\n12\n16\n20\n22\n4.\nInternational airports\nfor 200 persons\nfor 600 persons\nfor 1000 persons\n6\n12\n18\n10\n20\n29\n8\n16\n22\nNote. - Provision for wash basins, baths including shower stalls, shall be in accordance with Part IX Section 2 Drainage and Sanitation of the Code.\nNote.\n(x) Special Requirements of Individual Occupancies\n(x) Special Requirements of Individual Occupancies",
"footnote": "",
"is_definition": false,
"sort_order": 83
},
{
"number": "90",
"title": "90. Cinemas, Theatres and Public Assemble Halls.",
"chapter": null,
"content": "(2) Set back from regular line of the street for Cinema/Assembly buildings.",
"footnote": "",
"is_definition": false,
"sort_order": 84
},
{
"number": "91",
"title": "91. Factories and Industrial Structures-Provisions of the Factories Act, 1948 (No. LXIII of 1948) to apply.",
"chapter": null,
"content": "(2) Location of Factory.\n(3) Disposal of Trade Waste and Effluent.\n(4) Planning, design and construction of factories to be to the satisfaction of Chief Inspector of Factories.",
"footnote": "",
"is_definition": false,
"sort_order": 85
},
{
"number": "92",
"title": "92. Petrol filling stations.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 86
},
{
"number": "93",
"title": "93. Signs and outdoor display structure-Provisions of Code to apply.",
"chapter": null,
"content": "(3) General.\n(a) any sign that by reason of its shape, position or colour may be confused with an authorised traffic sign or signal;\n(b) any sign containing the word \"Stop\" \"Lock\" \"Danger\" or other similar word that might mislead or confuse the travellers;\n(c) any sign that is attached to or printed on a rock or other natural objects; and\n(d) any sign that is located within a public right-of-way unless it is an official street name, traffic signs or signal or other official sign.\n(4) Ground Signs.\n(a) Dimension. - No ground sign shall be erected to a height exceeding 9 metres above the ground. Lighting reflections may extend beyond the top of face of the sign;\n(a) Dimension.\n(b) Supports and Anchorage. - Every ground sign shall be firmly supported and anchored to the ground, supports and anchors shall be of treated timber in accordance with good practice or metal treated for corrosion resistance or masonry or concrete;\n(b) Supports and Anchorage.\n(c) Obstruction to Traffic. - No ground sign shall be erected so as to obstruct from access to or egress from any building; and\n(c) Obstruction to Traffic.\n(d) Set Back. - No ground sign shall be set nearer to the street line than the established building line.\n(d) Set Back.\n(5) Roof sign.\n(a) Location. - No roof sign shall be placed on or over the roof of any building, unless the entire roof construction is of noncombustible material;\n(a) Location.\n(b) Projection. - No roof sign shall project beyond the existing building line of the building on which it is erected or shall extend beyond the roof in any direction: and\n(b) Projection.\n(c) Support and Anchorage - Every roof sign shall be thoroughly secured and anchored to the building on or over which it is erected All loads shall be safely distributed to the structural members of the building.\n(c) Support and Anchorage\nWall signs\n(a) Dimensions - The total area of the sign shall not exceed 10 per cent of the total area of the facede on which the sign is created. The facede of the building shall be sub-divided into blocks of uniform height and the area of the sign erected on a particular block shall not exceed 10 per cent of the area of that block;\nDimensions\n(b) Projection -No wall sign shall extend above the top of the wall or beyond the ends of the wall to which it is attached. At any place where pedestrians may pass along a wall, any wall sign attached thereto shall rot project more than 7.5 centimetres therefrom within a height of 2.5 metres measured from the level of such place,\nProjection\n(c) Support and Attachment -Every wall sign shall be securely attached to walls. Wooden blocks or anchorage with wood used in connection with screws, staples or nails shall not be considered proper anchorage, except in the case of wall signs attached to walls\nSupport and Attachment\n(d) Reflectors -Lighting reflectors may project 2.4 metres beyond the face of the wall provided such reflectors are at least 4 metres above the footpath level, but in no case shall such reflectors project beyond a vertical plane one metre inside the kerb line.\nReflectors\nProjecting Signs",
"footnote": "",
"is_definition": false,
"sort_order": 87
},
{
"number": "94",
"title": "94. Special requirements of Low-Income Housing Group.",
"chapter": null,
"content": "95 Power of Relaxation.\n[96. Plinth construction check survey.",
"footnote": "",
"is_definition": false,
"sort_order": 88
},
{
"number": "97",
"title": "97. Issue of Service Certificate.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 89
},
{
"number": "98",
"title": "98. Completion certificate.",
"chapter": null,
"content": "Appendix A\nAppendix A\n[Rule 17(1)]\nForm for First Application to Develop, Erect, Re-Erect or to Make Alteration in any Place in a Building\nForm for First Application to Develop, Erect, Re-Erect or to Make Alteration in any Place in a Building\nI hereby give notice that I intend to develop, erect, re-erect or to make alteration in the building No....................or to...................on/in Plot No................in colony/Street...................Mohalla/Bazar/Road. ................City.................and in accordance with the Rule 17 of the Madhya Pradesh Bhumi Vikas Rules, 1984. I forward herewith the following plans and specifications in quadruplicate duly signed by me and................ the Architect/Structural Engineer/Engineer/Supervisor/Town Planner.\n(Name in Block letters)",
"footnote": "",
"is_definition": false,
"sort_order": 90
},
{
"number": "1",
"title": "1. Key Plan",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 91
},
{
"number": "2",
"title": "2. Site Plans",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 92
},
{
"number": "3",
"title": "3. Sub-Division/Layout Plan",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 93
},
{
"number": "4",
"title": "4. Building Plans",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 94
},
{
"number": "5",
"title": "5. Services Plans",
"chapter": null,
"content": "[6. Specifications, General and Detailed]",
"footnote": "",
"is_definition": false,
"sort_order": 95
},
{
"number": "7",
"title": "7. Ownership Title.",
"chapter": null,
"content": "I, request that the development construction may be approved and permission accorded to me to execute the work.\nSignature of the Owner.........\nName of the Owner..............\nAddress of the Owner...........\nAppendix B\nAppendix B\n[Rule 17 (9)]\nForm for Supervision\nForm for Supervision\nSignature of Architect/Structural Engineer/Engineer,\n\t\t\t\tSupervisor/Town Planner\n................\nName of Architect/Structural Engineer /Engineer /Supervisor\n\t\t\t\t/Town Planner\n................\n(in block letters)\nLicence No. of Architect/Structural Engineer / Engineer\n\t\t\t\t/Supervisor /Town Planner\n................\nAddress of Architect/Structural\n\t\t\t\tEngineer/Engineer/Supervisor/Town Planner\n................\nAppendix C\nAppendix C\n[Rule 26]\nForm of Licence Issued under Madhya Pradesh Bhumi Vikas Rules, 1984 To work as Architect/structural Engineer/engineer/supervisor/town Planner\nForm of Licence Issued under Madhya Pradesh Bhumi Vikas Rules, 1984 To work as Architect/structural Engineer/engineer/supervisor/town Planner\nDate...........\nPlace Date\nSeal of Authority\nSignature & designation of the authorised Officer to\n\t\t\t\tgrant licence.\nConditions\nConditions\nA. Architect\n(a) all plans and information connected with building permit;\n(b) structural details and calculations for residential buildings on plot up to 500 square metres and up to three storeys or 11 metres in height;\n(c) certificate of the supervision and completion of all buildings;\n(d) all plans and related information connected with development permit of area up to one hectare; and\n(e) certificate of supervision c*f development of land of area upto one hectare.\nB. Structural Engineer\n(a) all plans and information connected with permission for all buildings irrespective of size and height;\n(b) structural details and calculations for all buildings;\n(c) certificate of supervision and completion of all buildings;\n(d) all plans and related information connected with permission for development of area up to one hectare;\n(e) certificate of supervision for development of land upto one hectare in area.\nC. Engineer\n(a) all plans and information connected with building permit;\n(b) structural details and calculations for all buildings;\n(c) certificate of supervision and completion for buildings up to 500 sq. metres and 4 storeys (15m);\n(d) all plans and related information connected with development permit of area up to one hectare; and\n(e) certificate of supervision for development of land of area up to one hectare.\nD. Supervisor\n(a) all plans and related information connected with building permit for residential buildings up to 200 square Metres and up to two storeys or 7.5,metres in height.\n(b) certificate of supervision for buildings in (a).\nE. Town Planner\n(a) all plans and related information connected with development permit of all areas;\n(b) certificate of supervision for development of land of all areas.\nb. Group of Agency\nAppendix D\nAppendix D\n[Rule 27]\nForm for Sanction of Refusal of Permission of Development Permission for Building\nForm for Sanction of Refusal of Permission of Development Permission for Building\nWith reference to your application.......................dated...............for grant of permit for the development of land/building in khasra No. . . .................on/in plot No......................in colony/street................. Mohalla/Bazar........................City No.....................I have to inform you that the sanction has been refused/granted by the Authority on the following grounds/subject to the following terms and conditions :-\n2.\n3.\n4.\n5. or\n................ Signature of the Authority Name and Designation Address of Authority\nAppendix E\nAppendix E\n[Rule 31 (2)(d)]\nForm for Notice for Commencement\nForm for Notice for Commencement\nSignature of Owner Name of Owner (in block letters) Address of Owner\nAppendix F\nAppendix F\n[Rule 31 (2)(c)]\nForm of Notice for Inspection of Building at Plinth Level\nForm of Notice for Inspection of Building at Plinth Level\nSignature of the owner Name of owner (in block letters) Address of owner\nAppendix G\nAppendix G\n[Rule 31 (2)(f)]\nForm for Completion Certificate\nForm for Completion Certificate\nSignature of Architect/Structural Engineer/Engineer,\n\t\t\t\tSupervisor/Town Planner\n................\nName of Architect/Structural Engineer /Engineer /Supervisor\n\t\t\t\t/Town Planner\n................\n(in block letters)\nLicence No. of Architect/Structural Engineer / Engineer\n\t\t\t\t/Supervisor /Town Planner\n................\nAppendix H\nAppendix H\n[Rule 31 (2)(g)]\nForm for Occupancy Permit\nForm for Occupancy Permit\n1.\n2.\n3.\nOne set of completion plans duly certified is returned herewith.\nSignature of the Authority.\nAppendix J\nAppendix J\n[Rule 38 (1)]\nIndustries Permitted in Residential and Commercial Zones\nIndustries Permitted in Residential and Commercial Zones\nPart I\nA List of Industries which may be Permitted in Zone R1\n(i) Blanco cake\n(ii) School chalk\n(iii) Tailoring chalk\n(iv) Chalk crayon\n(i) Desktop\n(ii) Personnel Computer\n(iii) Servers\n(iv) Work-Station\n(v) Nodes\n(vi) Terminals\n(vii) Net-work P.C.\n(viii) Home P.C. ,\n(ix) Lap-top Computer\n(x) Note Book Computer\n(xi) Palm Top Computer PDA.\n(i) Net-work Interface Card (NIC)\n(ii) Adapter-Ethornet/PCI/EISA/Conmbao/PCMCIA.\n(iii) SIMMS-Memory\n(iv) DIMMs-Memory\n(v) Central Processing Unit (CPU)\n(vi) Controller-SCSI/Array\n(vii) Processors-Processor/Processor Power Module/Upgrade\n(i) Hard Disk Drives/Hard Drives\n(ii) Raid Devices & their Controllers\n(iii) Floppy Disk Drives\n(iv) C.D. ROM Drives\n(v) Tape-Drives-DLT Drives DAT\n(vi) Optical Disk Drives\n(vii) Other Digital Storage Devices\n(viii) CD WRITE-RE WRITE DEVICES.\n(i) Key Board\n(ii) Monitor\n(iii) Mouse\n(iv) Multi-media Kits.\n(i) Dot-Metrix\n(ii) Laserjet\n(iii) Inkjet\n(iv) Deskjet\n(v) LED Printers\n(vi) Line Printers\n(vii) Glotters\n(viii) Pass-book Printers.\n(i) Hobs\n(ii) Routers\n(iii) Electronic Switches\n(iv) Concentrators\n(v) Trans-receivers.\n(i) Application Software\n(ii) Operating system\n(iii) Middleware/Firmware.\n(i) Switch, mode power supplies\n(ii) Uninterrupted power supplies.\n(i) Fibre Cable\n(ii) Signal Single Cable (Copper)\n(iii) Cables\n(iv) Connectors, Terminal Blocks\n(v) Jack panels, patch cord\n(vi) Mounting Cord, patch panels\n(vii) Bread Borads, wiring blocks\n(viii) Surface mount boxes.\n(i) C.D. ROM/Compact Disk\n(ii) Floppy Disk\n(iii) Tapes DA/DLT\n(iv) Prints Ribbons\n(v) Toners for printers\n(vi) Inkjet Cartridges\n(vii) Inks for Output devices.\n(i) Printed Circuit Board assembly/populated.\n(ii) Printed Circuit Board/PLB\n(iii) Transistors\n(iv) Integrated Circuits/ICs\n(v) Diodes/Thyristor/LED\n(vi) Resistors\n(vii) Capacitors\n(viii) Switches (On/off, Push button, Rocker etc).\n(ix) Plugs/Sockets/relays used for Computers/Electronic.\n(x) Magnetic heads for Computer devices and Print heads for Computer Printers.\n(xi) Connectors\n(xii) Microphones/Speakers used in Computers\n(xiii) Fuses.\n(i) Videophones\n(ii) Fax Cards\n(iii) Multiplexers/Muxes\n(iv) Modome\n(v) Amtonna & Mest\n(vi) Wireless datacom equipment-including Set\n(vii) Top Boxes for both Video and Digital Signalling\n(viii) VSATS\n(ix) Video Conferencing Equipments.\nNote. - 1. Whole-salers, retailers, marketing agents, distributors consignment and forwarding agents dealing in the above items shall not be included.\nNote.",
"footnote": "",
"is_definition": false,
"sort_order": 96
},
{
"number": "2",
"title": "2. Condition of \"not more than 5 workers at a time are employed\" is not applicable for industries listed after number 40].",
"chapter": null,
"content": "Part II\nList of Industries Which may be Permitted in Zone R2\nList of Industries Which may be Permitted in Zone R2\nThese products will include only-\n(i) Paper pins\n(ii) Blouse hooks\n(iii) Gem clips\n(iv) Glued staples\n(v) Curtain rings\n(vi) Key rings\nPart III\nList of Items Manufacture of Which may be Allowed in Commercial areas with A Restricted Power Load of 5 K.W.\nList of Items Manufacture of Which may be Allowed in Commercial areas with A Restricted Power Load of 5 K.W.\nCommercial/Hosiery/Paper Products\nCommercial/Hosiery/Paper Products\n(i) Plates\n(ii) Cups\n(iii) Envelops\n(iv) Drinking Straws\n(v) Paper bags.\n(a) Switches other than Reed Relays\n(b) Relays other than Reed Relays\nMechanical\nMechanical\nAppendix K\nAppendix K\n[Rule 49 (3)]\nForm for Obtaining Proposals of Development Plan\nForm for Obtaining Proposals of Development Plan\nI hereby intend to develop/redevelop the land of khasra No.........on/in plot No..........in Colony/Street................... in Mohalla/Bazar....... in City..........The proposals of the Development Plan/Zonal Development Plan pertaining to the area may be made available for the preparation of sub-division plan for the land referred to above. The necessary payment for procuring the proposals of Development Plan/Zonal Development Plan has been made and the attested copy of receipt in enclosed.\nSignature of Owner Name of Owner (in block letters) Address of Owner\nAppendix L\nAppendix L\n[Rule 81]\nOff-Street Parking Spaces\nOff-Street Parking Spaces\n(a) Motor Vehicles -Space shall be provided as specified in the following Table for parking motor vehicles (cars).\nMotor Vehicles\nTable\nTable\nOff-Street parking spaces\nOff-Street parking spaces\n(Clause L-(3))\nOne car parking space for every\nSl. No.\nOccupancy\nPopulation 2,00,000 to 10,00,000\nPopulation 50,000 to 2,00,000\nPopulation less than 50,000\n(1)\n(2)\n(3)\n(4)\n(5)\n1.\nResidential (i) Multi-family\n(a) 2 tenements having carpet area 101 to 200 square\n\t\t\t\tmeters. (b) 1 tenements Exceeding 201 sq. meters carpet area.\n(ii) Lodging establishments tourist Homes and hotels, with\n\t\t\t\tlodging accommodations.\n4 guest rooms\n8\n12\n2.\nEducational\n70 square meters carpet area of fraction there of\n\t\t\t\tAdministrative office area and public service areas.\n3.\nInstitutional (Medical)\n10 beds (private) 15 beds (public)\n15 (private) 25 (public)\n20 (private) 30 (public)\n4.\n(i) Assembly Halls, Cinema Theatres\n25 seats\n80\n120\n(ii) Restaurants Up to first 20 seats nil, one for every\n\t\t\t\tAdditional\n20 seats\n40\n60\n(iii) Marriage Halls, Community Hall\n200 square meters plot area.\n400 square meter plot area.\n600 square meter plot area.\n5.\n(i) Business office and firms for private business.\n100 square meters carpet area or fraction thereof.\n200 square meter carpet area of fraction thereof.\n300 square meter carpet area or fraction there of.\n(ii) Public/or semi-public offices.\n200 square meters carpet area.\n300 squire meters carpet area.\n500 square meters carpet area.\n6.\nMercantile\n100 square meters carpet area or fraction thereof.\n200 square meters carpet area or fraction thereof.\n300 square meters carpet area or fraction thereof.\n7.\nIndustrial\n200 square meters carpet area or fraction thereof.\n300 square meter carpet area or fraction thereof.\n400 square meters carpet area or fraction thereof.\n8.\nStorage\n500 square meters or part thereof.\nNote 1. - In the case of auditoria for educational buildings parking space shall be provided as Per Serial No. 4.\nNote 2. - For plots upto 100 square metres as in the case of shops. Parking space need not be insisted on.\nNote 3. - For other institutions transport/communication centre parking space requirement shall be assessed based on proposed building.\nNote 4. - The requirement for off-street parking for metropolitan city with population more than 4,00,000 shall be broadly based on column (3) and appropriately adopted to suit the increased traffic generated, the traffic pattern as well as the nature of vehicles in the city.\n(b) Other type of vehicles -For non-residential building, in addition to the parking areas provided in (a) above, 25 to 50 per cent, additional parking space shall be provided for parking other types of vehicles and the additional spaces required for other vehicles shall be as decided by the Authority, keeping in the nature of traffic generated in the city.\nOther type of vehicles\n[Appendix L-(A)]\n[Appendix L-(A)]\n[ See Rule 81]\nNote. - Area for each car space :-\nNote.\n(i)\nBasement\n35 Sq. m.\n(ii)\nStilts\n30 Sq. m.\n(iii)\nOpen\n25 Sq. m.\nAppendix M\nAppendix M\n[Rule 94]\nSpecial Requirements for Low Income Housing Only\nSpecial Requirements for Low Income Housing Only",
"footnote": "",
"is_definition": false,
"sort_order": 97
},
{
"number": "1",
"title": "1. General.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 98
},
{
"number": "2",
"title": "2. Planning. - (1) Type of Development",
"chapter": null,
"content": "(2) Density.\nTable\nTable\nMaximum Densities Low Income Housing\nMaximum Densities Low Income Housing\n[Clause M-2(2)]\nS.No.\nDensity in Dwelling Units/ha for plinth Area of\n\t\t\t\tUnit of No. of\nStoreys\n20 square metres\n30 square metres\n(i)\n130\n85\n1\n(ii)\n250\n170\n2\n(iii)\n300\n225\n3\n(iv)\n350\n260\n4\n(v)\n400\n300\n5\nNote 1. - These densities are applicable to a cluster of dwellings up to 400 with a family of 5 members.\nNote 2. - Vertical incremental housing shall be permitted in single ownership plot.\nNote 3. - These densities include provision for open spaces convenient-shopping, nursery, and all internal roads and pathways, but do not include peripheral road around the cluster.\nNote 4. - The minimum density shall be 75 per cent of the above.\nSize of Plot/Plinth Area.\nMinimum Plot Size-\n30 square metres\nIncremental housing with one room, cooking space and combined\n\t\t\t\tbath and WC on ground floor and future extension of one room and\n\t\t\t\ta bath on the first floor/ground floor.\n40 square metres\nTwo roomed house on each floor for Group Housing/Individual\n\t\t\t\townership house.\nNote 1. - The minimum size of plots takes into account the need of incremental housing. In the case of cities (other than metropolitan cities) with population less than 0.5 million, the size of the plots may be increased by 33⅓ per cent.\nNote 1.\nNote 2. - In exceptional cases in metropolitan cities with population more than 1 million, the size of plots may be brought down to 25 square metres in cases of low income house colonies located in congested areas or in areas as decided by the Authority.\nNote 2.\n(ii) Minimum Frontage. - The minimum frontage of the plot shall be 3.6 metres in width.\nMinimum Frontage.\nNote. - The minimum frontage of 3.6 metres is desirable. For an economical layout, group housing appears to be a good solution. But if plotted development is to be adopted and if there are occasions when sufficient frontage is not available the same may be reduced to 3 metres.\nNote.\nHeight of building\nNote. - For building up to the height of 15 metres, there is no need to provide lifts.\nNote.",
"footnote": "",
"is_definition": false,
"sort_order": 99
},
{
"number": "3",
"title": "3. General Building Requirements.",
"chapter": null,
"content": "Plinth.\nSize of room.\n(i) In the case of one-roomed house, the size of the multipurpose room including space for cooking shall be not less than 10 square metres with a minimum width of 2.4 metres.\n(ii) In the case of two-roomed house, the size of a room shall not be less than 6.5 square metres with a minimum width of 2.1 metres provided that total area of both rooms is not less than 15 square metres. In case of incremental housing to be developed as a future two roomed house, the total area of rooms to be provided in the initial and later stages should not be less than 16 square metres.\n(b) W.C./Bath Room-\n(i) Size of independent water closet shall be 0.9 X 1.0 metres.\n(ii) Size of independent bath shall be 1.0 X 1.2 metres.\n(iii) Size of combined bath and water closet shall be 1.0 X 1.8 metres and this may be permitted in one roomed house.\n(c) Kitchen. - The size of a cooking alcove serving as cooking space shall not be less than 2.4 square metres with minimum width of 1.2 metres. The size of individual kitchen provided in two-roomed house shall not be less than 3.3 square metres with a minimum width of 1.5 metres.\nKitchen.\n(d) Balcony. - The minimum width of individual balcony, where provided, shall be 0.9 metre.\nBalcony.\nMinimum Height.\n(a) Habitable Room-2.6 metres\n(b) Kitchen-2.4 metres\n(c) Bath/W.C. - 2.2 metres\n(d) Corridor-2.1 metres.\n(ii) In the case of sloping roofs, the average height of roof for habitable rooms shall be 2.6 metres and the minimum height at eaves shall be 2.0 metres.\nLighting and Ventilation.\nNote. - The window and other opening shall abut on to open spaces either through areas left open within the plot or the front, side and rear spaces provided in the layouts which shall be treated as deemed to be sufficient for light and ventilation purposes.\nNote.\nStairs.\n(a) Minimum Width\n(i) 2 storeyed-straight\n0.60 metre\n(ii) 2 storeyed-winding\n0.75 metre\n(iii) 3 or more storeyed-straight\n0.75 metre\n(iv) 3 or more storeyed-winding\n0.90 metre\n(b) Riser 20 Centimetres Max.\n(c) Tread\n(i) 2 storeyed\n22.5 centimetres min.\n(ii) 3 storeyed or more\n25 centimetres minimum.\nNote. - This could be reduced to 20 centimetres as the clear tread between perpends, with possibility of open rise as well as nosing and inclined riser to have an effective going of 22.5 centimeter.\nNote.\n(d) Head Room. - The minimum clear head room shall be 2.1 metres.\nHead Room.\nCirculation Area.",
"footnote": "",
"is_definition": false,
"sort_order": 100
},
{
"number": "4",
"title": "4. Roads and Pathways.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 101
},
{
"number": "5",
"title": "5. Other Requirements",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 102
},
{
"number": "6",
"title": "6. Site and Services Schemes.",
"chapter": null,
"content": "(a) the infrastructural needs for a permanent housing depending upon requirements.\n(b) a service sanitary core in the plot;and\n(c) permission to allow temporary construction or a developed plinth may be provided, where feasible.\n[Appendix N-1]\n[Appendix N-1]\n[ See Rule 78]\nRain Water Harvesting through Percolation Pits\nRain Water Harvesting through Percolation Pits\n[Appendix N-2] Rain Water Harvesting through Pebble Bed (Building Complexes)\n[Appendix N-2]\nRain Water Harvesting through Pebble Bed\nRain Water Harvesting through Pebble Bed\n(Building Complexes)\n[Appendix N-3]\n[Appendix N-3]\nRain Water Harvesting through Service Well Cum Recharge Well\nRain Water Harvesting through Service Well Cum Recharge Well\n[Appendix-O]\n[Appendix-O]\nGuiding/warning floor material.\n(a) The access path to the building and to the parking area;\n(b) The landing lobby towards the information board, reception, lifts, stair-cases and toilets;\n(c) Immediately at the beginning/end of walk-way where there is a vehicular traffic;\n(d) At the location abruptly changing in level or beginning/end or a ramp;\n(e) Immediately in front of an entrance/exit and the landing.\nProper Signage.",
"footnote": "",
"is_definition": false,
"sort_order": 103
}
],
"metadata": {
"Act ID": "mp111",
"Act Number": "Published vide Notification No. 2869-32-84, dated 18-9-1984, Madhya Pradesh Rajpatra (Asadharan), dated 12-11-1984, pp. 2853-2964",
"Enactment Date": "",
"Act Year": "1984",
"Short Title": "The M.P. Bhumi Vikas Rules, 1984",
"Type": "STATE",
"Location": "Madhya Pradesh"
},
"updated_at": "2026-09-29 21:55:20"
}