The Static And Mobile Pressure Vessels (Unfired) Rules, 1981
The Static And Mobile Pressure Vessels (Unfired) Rules, 1981
Sections
CHAPTER I
CHAPTER I
Section 11. Short title and commencement
Section 12. Definition
Section 25. Restriction on delivery and despatch
Section 56. Repair to pressure vessels
Section 67. Purging of pressure vessels used for flammable gases
Section 78. Prohibition of employment of children and intoxicated persons
Section 89. Prohibition of smoking, fires, lights, etc
Section 910. Special precautions against accidents
Section 10
CHAPTER II
CHAPTER II
Section 1012. Design code
Section 1213. Design pressure
Section 1314. Design of vessels for gases at low temperature
Section 1415. Filling capacity and filling pressure
Section 1516. Markings on pressure vessels
Section 1617. Painting of vessels
Section 1718. Fittings
Section 1819. Periodic testing of pressure vessels in service
Section 1920. Precautions to be observed in carrying out hydraulic test
Section 20
CHAPTER III
CHAPTER III
Section 2021. General
Section 2123. Foundations for pressure vessels
Section 2324. Fencing
Section 2425. Cleanliness
Section 2526. Earthing
Section 2627. No smoking
Section 2728. Fire protection
Section 2829. Loading and unloading facilities
Section 2930. Transfer operations
Section 3031. Electrical apparatus and installations
Section 3132. Lighting of storage and operating areas
Section 3233. Certificate of safety
Section 33
CHAPTER IV
CHAPTER IV
Section 3334. Application
Section 3435. Vehicles for transport of compressed gas
Section 3536. Design
Section 3637. Protection of valves and accessories
Section 3738. Equipment
Section 3839. Vehicle design considerations
Section 3940. Marking of vehicle
Section 4041. Fire protection
Section 4142. Operations
Section 4243. Certificate of safety [in prescribed pro forma ]
Section 4344. Inspection and maintenance of vehicles
Section 44
CHAPTER V
CHAPTER V
Section 4545. License for storage of compressed gas
Section 4546. Prior approval of specification and plans of vessels and premises proposed to be licensed
Section 4647. License for transport of compressed gas
Section 4748. Grant of license
Section 4850. Period for which licenses may be granted or renewed
Section 5051. Particulars of license
Section 5152. Power of licensing authority to alter conditions.
Section 5253. Prior approval necessary for alteration in the licensed premises
Section 5354. Amendment of license
Section 5455. Renewal of license
Section 5556. Refusal of license
Section 5657. Suspension and cancellation of license
Section 5758. Procedure on expiration, suspension or cancellation of license
Section 5859. Appeals
Section 5960. Procedure on death or disability of licensee
Section 6061. Loss of license
Section 6162. Production of license on demand
Section 6263. Procedure on reports of infringement
Section 6364. Executive control over authorities
Section 64
CHAPTER VI
CHAPTER VI
Section 6565. Powers to exempt
Section 65
CHAPTER VII
CHAPTER VII
Section 6766. Notice of accident
Section 6667. Inquiry into accidents
Section 6768. Inquiry into more serious accidents
Section 68
CHAPTER VIII
CHAPTER VIII
Section 7169. Powers of inspection, search, seizure, detention and removal
Section 691. Applicant's name** The replies to be given in this column. Applicant's calling _________________________________ Applicant's Full postal address _________________________________ 2. Situation of the premises where liquefied petroleum gas is to be stored. _________________________________ State _________________________________ District _________________________________ Town or Village _________________________________ Nearest Railway Station _________________________________ 3. Nature of comp
Section 17. Does (vehicle described above) fully conform to the requirements laid down in the rules and the design drawing approved by the Chief Controller.
Section 7
the-static-and-mobile-pressure-vessels-unfired-rules-1981.json
•
74 Sections
•
India (Central)
{
"id": 13201,
"slug": "the-static-and-mobile-pressure-vessels-unfired-rules-1981",
"title": "The Static And Mobile Pressure Vessels (Unfired) Rules, 1981",
"short_title": "The Static And Mobile Pressure Vessels (Unfired) Rules, 1981",
"act_number": "Published vide G.S.R. 45(E), dated 4.2.1981, publi",
"act_year": 1981,
"act_type": "CENTRAL",
"location": "India (Central)",
"law_status": "unknown",
"enactment_date": null,
"description": "The Static And Mobile Pressure Vessels (Unfired) Rules, 1981",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "CHAPTER I",
"chapter": "CHAPTER I",
"content": "Preliminary",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "1",
"title": "1. Short title and commencement",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 1
},
{
"number": "2",
"title": "2. Definition",
"chapter": null,
"content": "(a) \"Act\" means the Indian Explosives Act, 1884 (4 of 1884);\n(b) \"approved\" means a drawing, design, specification or code approved by the Chief Controller;\n[(bb) \"bottling plant\" means a premises where cylinders are filled with compressed gas;]\n(c) \"Chief Controller\" means the Chief Controller of Explosives;\n[(d) \"competent person\" means a person or an organisation recognised by the Chief Controller, for such gases and for such period as may be specified as competent for carrying out tests, examination, inspections and certification for installations and transport vehicles as stipulated in these rules, if such a person or organisation possesses the qualifications, experience and other requirements as set out in Appendix II to these rules and is recognised as per procedure laid down in rule 11-A:\n[(e) \"compressed gas\" means any permanent gas, liquefiable gas or gas dissolved in liquid or cryogenic liquid under pressure or gas mixture, which in a closed pressure vessel exercises a pressure exceeding one atmosphere (gauge) at maximum working temperature and includes Hydrogen Fluoride. In case of vessel without insulation or refrigeration, the maximum working temperature shall be considered as 550C;]\n(f) \"Controller of Explosives\" includes the Deputy Chief Controller of Explosives, Deputy Controller of Explosives and Assistant Controller of Explosives;\n(g) \"corrosion\" means all forms of wastage, and includes oxidation, scaling, mechanical abrasion and erosion;\n[(gg) \"critical temperature\" means the temperature above which gas cannot be liquefied by the application of pressure alone;]\n[(gg-a) \"cryogenic liquid\" means liquid form of permanent gas having normal boiling point below minus 1650 C;\n(gg-b) \"cryogenic pressure vessel\" means a pressure vessel intended for storage or transportation of cryogenic liquid and includes cold converters, vacuum insulated evaporators, vacuum insulated storage or transport tanks and thermosyphon tanks;]\n[(ggg) \"cylinder\" or \"gas cylinder\" means any closed metal container intended for storage and transport of compressed gas having the same meaning as assigned to it in clause (xvi) of rule 2 of the ] [Gas Cylinders Rules, 1981]\n(h) \"design\" includes drawings, calculation, specifications, models, codes and all other details necessary for the complete description of the pressure vessel and its construction;\n(i) \"design pressure\" means the pressure used in the design calculations of a vessel for the purpose of determining the minimum thickness of the various component parts of the vessel;\n[(ii) \"dispenser\" means an equipment installed in liquefied petroleum gas dispensing station, meant for dispensing liquefied petroleum gas as automotive fuel to motor vehicles;]\n(j) \"district authority\" means-\n(i) in towns having a Commissioner of Police, the Commissioner or a Deputy Commissioner of Police; and\n(ii) in any other place, the District Magistrate;\n(k) \"filling density\" means the ratio of weight of liquefiable gas allowed in a pressure vessel to the weight of water that the vessel will hold at 150C;\n[(kk) \"fill point\" means the point of the inlet pipe connection of a vessel where hose is connected for filling the compressed gas into the vessel;]\n(l) \"flammability range\" means the difference between the minimum and maximum percentage by volume of the gas in mixture with air that forms a flammable mixture at atmospheric pressure and ambient temperature;\n(m) \"flammable compressed gas\" means gas 13 per cent. or less of which when mixed with air forms a flammable mixture or whose flammable range with air is greater than 12 per cent.;\n(n) \"Form\" means the Form appended to these rules;\n(o) \"gas free\" in relation to a pressure vessel means the concentration of flammable or toxic gases or both if such pressure vessel is within the safe limits specified for persons to enter and carry out hot work in such vessels;\n[(p) \"Inspector\" means a professional organisation recognised by the Chief Controller for certifying pressure vessels and their fittings after carrying out stagewise inspection during fabrication as stipulated in the rules so as to ensure that the pressure vessels are designed and constructed in accordance with IS: 2825 or any other Code approved by the Chief Controller, if the constituent members of the organisation possesses the qualifications and experience and other requirements as set out in Appendix II to these rules and the recognition is granted as per procedure laid in rule 11-A;]\n(q) \"installation\" means any place which has been specially prepared for the storage of compressed gas in pressure vessels;\n(r) \"liquefiable gas\" means any gas that may be liquefied by pressure above 00C, but will be completely vaporised when in equilibrium with normal atmospheric pressure (760 mm Hg) at 300C;\n[(ra) \"liquefied petroleum gas\" includes hydrocarbon gases in liquefied state at normal ambient temperature by the application of pressure, and conforming to the Indian Standard Specification No. IS : 4576;\n(rb) \"liquefied petroleum gas dispensing station\" means a premises used for storing and dispensing liquefied petroleum gas as automotive fuel to the motor vehicles;\n(rc) \"motor vehicle\" means a vehicle having the meaning assigned to it in sub-section (28) of section 2 of the Motor Vehicles Act, 1988 (59 of 1988);\n(rd) \"petroleum service station\" means a premises used for storage of petroleum for the purpose of fuelling motor vehicles, and licensed in Form XII of the Petroleum Rules, 1976;]\n(s) \"permanent gas\" means a gas whose critical temperature is lower than 100C;\n[(t) \"pressure vessel\" means any closed metal container of whatever shape, intended for the storage and transport of any compressed gas which is subjected to internal pressure and whose water capacity exceeds one thousand litres and includes interconnecting parts and components thereof up to the first point of connection to the connected piping and fittings, but does not include containers wherein steam or other vapour is or is intended to be generated or water or other liquid is or is intended to be heated by the application of fire or the products of combustion or by electrical means, heat exchangers, evaporators, air receivers, steam type digestors, steam type sterilizers, autoclaves, reactors, calorifiers, pressure piping components, such as, separators or strainers and vessels containing a liquid under a blanket of compressed inert gas;]\n(u) \"safety relief device\" means an automatic pressure relieving device actuated by the pressure upstream of the valve and characterised by fully opened pop action, intended to prevent the rupture of a pressure vessel under certain conditions of exposure;\n(v) \"source of ignition\" means naked lights, fires, exposed incandescent materials, electric welding arcs, lamps, other than those specially approved for use in flammable atmosphere, or a spark or flame produced by any means;\n[(vv) \"tank truck loading or unloading gantry\" or \"hard stand\" means the position of parking of tank truck or mobile pressure vessel for loading or unloading of compressed gas into or from it;]\n(w) \"transport\" means the transport of a pressure vessel filled with any compressed gas from one place to another but does not include movement of the vessel from one place to another in the same premises;\n(x) \"vehicle\" means a mechanically propelled carriage designed to transport by land compressed gas in a pressure vessel mounted thereon, and shall not include a vessel forming the barrel of a rail tank wagon;\n(y) \"vessel\" means a pressure vessel;\n(z) \"water capacity\" means capacity in litres of the pressure vessel when completely filled with water at 150C.\n[3. General exemptions\n[4. Restriction on filling, manufacture and import\n(a) the particulars specified in Appendix I to these rules; and\n(b) a scrutiny fee of rupees five hundred in the manner specified under rule 11.\n(a) a test and inspection certificate of the vessel from the manufacturer or the inspecting agency of the country of origin;\n(b) the design details of the vessel, its fittings and particulars of specifications of the materials used in construction thereof; and\n(c) a scrutiny fee of rupees five hundred in the manner specified under rule 11.]",
"footnote": "",
"is_definition": true,
"sort_order": 2
},
{
"number": "5",
"title": "5. Restriction on delivery and despatch",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "6",
"title": "6. Repair to pressure vessels",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "7",
"title": "7. Purging of pressure vessels used for flammable gases",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "8",
"title": "8. Prohibition of employment of children and intoxicated persons",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "9",
"title": "9. Prohibition of smoking, fires, lights, etc",
"chapter": null,
"content": "[9-A. Supervision and operation within the licensed premises",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "10",
"title": "10. Special precautions against accidents",
"chapter": null,
"content": "(i) comply with the provisions of these rules and the conditions of any license issued thereunder;\n(ii) observe all precautions for the prevention of accident by fire or explosion; and\n(iii) prevent any person from committing any act referred in sub-rule (1).\n[11. Procedure for payment of fees\n[11-A. Procedure for grant and revocation of recognition to competent person and Inspector\n(a) if he has reason to believe that an Inspector or competent person has violated any condition stipulated in the letter of recognition or has carried out a test, examination and inspection or has acted, in a manner inconsistent with the intent or the purpose of these rules; or\n(b) for any other reason to be recorded in writing.]",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "10",
"title": "CHAPTER II",
"chapter": "CHAPTER II",
"content": "Construction And Fitments Of Pressure Vessels",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "12",
"title": "12. Design code",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "13",
"title": "13. Design pressure",
"chapter": null,
"content": "(a) the vapour pressure of the gas in the vessel at 550C, if the vessel is meant for the storage of liquefiable gases:-\n(b) the developed pressure of the gas in the vessel at 550C, if the vessel is meant for the storage of a permanent gas.\n[(c) the maximum allowable service pressure with additional allowances for vacuum and static head or surge due to acceleration or deceleration, as the case may be, in respect of the cryogenic liquid proposed to be stored or transported.]",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "14",
"title": "14. Design of vessels for gases at low temperature",
"chapter": null,
"content": "(ii) The capacity of the refrigeration system shall be adequate to maintain the gas in the vessel at a temperature so that its vapour pressure does not exceed the design pressure of the vessel and shall also remain below the pressure-setting of the relief valve on the vessel.\n(ii) The insulation shall be of sufficient thickness so that the thermal conductance at 150C (expressed in calories or sq. cm. per hour per degree centigrade temperature differential) does not exceed the limit prescribed by the Chief Controller.\n(ii) The materials of construction of the inner vessel, its piping and fittings shall be suitable for the service temperature and compatible for the specific cryogenic liquid.\n(iii) The outer vessel shall be made of steel not less than 3 mm nominal thickness or of aluminium not less than 4 mm nominal thickness and shall have required structural strength and capable for supporting the inner vessel together with cryogenic liquid, insulation and other fittings. The outer vessel of vacuum insulated cryogenic tanks shall be designed for a minimum collapsible pressure of one atmosphere (gauge). The suitable protecting coating shall be provided on the outer vessel to avoid corrosion. The outer vessel shall also be provided with suitable lifting arrangement and supports for installation or mounting.\n(iv) The inner supports between the inner vessel and the outer vessel shall be of non-inflammable materials and capable of supporting the inner vessel together with the maximum allowable cryogenic liquid. The supports shall be able to withstand expansion or contraction within the operating temperature range. Cryogenic pressure vessels meant for transport purpose, shall be able to withstand combined loading of vertical down of two, vertical upward of one and a half, longitudinal of one and a half and lateral of one and a half times the weight of the vessel with attachment and the full load of cryogenic liquid. The factor of safety of the supports shall be as per the design code.\n(v) The air in the annular space between the inner and outer vessel shall be evacuated and the space shall be filled with suitable insulating material compatible with the particular cryogenic liquid.]",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "15",
"title": "15. Filling capacity and filling pressure",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "16",
"title": "16. Markings on pressure vessels",
"chapter": null,
"content": "(i) manufacturer's name and identification marks;\n(ii) the standard or code to which the vessel is constructed;\n(iii) official stamp of the Inspector;\n(iv) design pressure in kg/cm2;\n(v) date of initial hydrostatic test and the subsequent test;\n(vi) hydrostatic test pressure in kg/cm2;\n(vii) water capacity in litres;\n(viii) gas capacity, if filled with liquefiable gas; and\n(ix) name or chemical symbol of the gas for which the vessel is to be used.",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "17",
"title": "17. Painting of vessels",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "18",
"title": "18. Fittings",
"chapter": null,
"content": "[(ii) Vessel connections .-Connections of vessels shall be designed and attached to the vessel in accordance with the Design Code specified under rule 12. All static vessels for storage of corrosive, flammable or toxic gas in liquefied state shall not have more than one pipe connection at the bottom for inlet or outlet, apart from the drainage. The drainage pipe, if provided, shall be extended beyond the shadow of the vessel and provided with two shut-off valves. No drainage pipe shall be provided direct from spherical vessel. The bottom inlet or outlet pipe for spherical vessel shall be integrally welded to the vessel and extended up to three metres beyond the shadow of the vessel, at the end of which, combination of manual and remote operated valve shall be provided.]\n[(ii) Vessel connections .-Connections of vessels shall be designed and attached to the vessel in accordance with the Design Code specified under rule 12. All static vessels for storage of corrosive, flammable or toxic gas in liquefied state shall not have more than one pipe connection at the bottom for inlet or outlet, apart from the drainage. The drainage pipe, if provided, shall be extended beyond the shadow of the vessel and provided with two shut-off valves. No drainage pipe shall be provided direct from spherical vessel. The bottom inlet or outlet pipe for spherical vessel shall be integrally welded to the vessel and extended up to three metres beyond the shadow of the vessel, at the end of which, combination of manual and remote operated valve shall be provided.]\n[(i-a) for cryogenic pressure vessels, the outer vessel shall be provided with a vacuum valve and safety relief device (disc) to release internal pressure. The discharge area of such device shall be at least 0.34 sq mm/litre of water capacity of the inner vessel. The relief device shall function at a pressure not exceeding the internal design pressure of the outer vessel;]\n(ii) the relief valves shall be spring loaded and shall be set-to-discharge and reach full flow conditions as required by the Design Code referred to in rule 12;\n(iii) weight loaded relief valves shall not be permitted;\n(iv) the relief valves shall be so designed that they cannot be inadvertently loaded beyond the set pressure;\n(v) the design of the valves shall be such that the breakage of any part will not obstruct free discharge of the liquid under pressure;\n(vi) safety relief valves on any vessel shall be set to start-to-discharge at a pressure not in excess of 110 per cent. of the design pressure of the vessel and shall have a total relieving capacity sufficient to prevent the maximum pressure in the vessel of more than 120 per cent. of the design pressure;\n[(vi-a)in case of cryogenic pressure vessels, the safety relief devices shall be set to discharge in such a manner that at least one such device shall be set at a pressure not higher than the maximum allowable working pressure and the other device may be set at a pressure not higher than 110% of the maximum allowable working pressure; ]\n(vii) each safety relief valve shall be plainly and permanently marked with the pressure in kg/cm2 at which it is set to discharge, with the actual rate of discharge of the device in cubic metres per minute of the gas at 150C and at atmospheric pressure, and with the manufacturer's name. The rated discharge capacity of the device shall be determined at a pressure of 120 per cent. of the design pressure of the vessel;\n(viii) connections of safety relief devices shall be of sufficient size to provide the required rate of discharge through the safety relief valves;\n(ix) safety relief valves shall be so arranged that the possibility of tampering is minimised and if the pressure setting or adjustment is external, the safety relief valve shall be provided with suitable means of sealing adjustment;\n(x) each safety relief valve shall be provided with shut-off valve between it and the vessel. The arrangement of the shut-off valve installed between the safety relief valve and the vessel shall be so designed as to afford full required capacity flow through at least one of the safety relief valves;\n(xi) safety relief valves shall have direct communication with the vapour space of the vessel;\n(xii) for vessels other than those mounted on the vehicles of over 4500 litres water capacity, relief valves shall be fitted with extended vent pipes adequately supported and having outlets at least 2 metres above the top of the vessel and at least 3.5 metres above the ground level and the vent pipes shall be fitted with loose-fitting rain caps;\n[(xiii) relief valves shall be tested by a competent person for correct operation not less than once in a year and a record of such test shall be maintained. The test certificate shall be issued in the prescribed pro forma .]\n(ii) all liquid and vapour connections on vessels, except those for relief valves, and drainage connections of small diameter, shall have an emergency shut-off valve, such as, an excess flow valve, an automatically operated valve or a remotely controlled valve. The emergency shut-off valve shall be in addition to the shut-off valve referred to in clause (i), unless the emergency shut-off valve is a remotely controlled valve which can be operated from a safe area and shall be of a type which shall not fail:\n(iii) where the emergency shut-off valve is of the excess flow type, its closing rate of flow shall be below the rate which is likely to result from a fracture of the line it is protecting, calculated under the most adverse weather conditions likely to be experienced. Excess-flow valves shall have a rated flow capacity sufficiently above normal flow requirements to prevent valve chatter.\n(ii) all liquid level indicators shall be suitable for operation at the design pressure of the vessel;\n(iii) every vessel shall, in addition, be equipped with a fixed maximum level indicating device depending upon the liquefiable gas or dissolved gas filled in the vessel;\n(iv) gauging devices that require bleeding of the contents of the vessel, such as, a rotary tube, fixed tube and slip tube shall be designed in such a manner that the same cannot be completely withdrawn in normal gauging operations.",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "19",
"title": "19. Periodic testing of pressure vessels in service",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "20",
"title": "20. Precautions to be observed in carrying out hydraulic test",
"chapter": null,
"content": "(i) before the test is carried out, each pressure vessel shall be thoroughly cleaned and examined externally, and as far as practicable, internally also for surface defects, corrosion and foreign matters. During the process of cleaning and removal of sludge, if any, all due precautions shall be taken against fire or explosion, if such sludge is of pyropheric nature or contains spontaneously combustible chemicals;\n(ii) as soon as the test is completed, the vessel shall be thoroughly dried internally and shall be clearly stamped with the marks and figures indicating the person by whom the test has been carried out and the date of test and a record shall be kept of all such tests;\n(iii) any vessel which fails to pass the hydraulic test or which for any other reason is found to be unsafe for use shall be destroyed or rendered unsuitable under intimation to the Chief Controller.",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "20",
"title": "CHAPTER III",
"chapter": "CHAPTER III",
"content": "Storage",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "21",
"title": "21. General",
"chapter": null,
"content": "(a) diameter of the vessel, in case of vessels with water capacity not exceeding forty thousand litres,\n(b) fifteen metres, if the water capacity of the vessels exceeds forty thousand litres.]\n[22. Location of pressure vessel\nTABLE 1\nMINIMUM SAFETY\nDISTANCES FOR CORROSIVE, TOXIC OR PERMANENT FLAMMABLE GASES\nSl. Nos Water capacity of vessel(in litres) Minimum distance From building or group of buildings or line of adjoining property Minimum distance between pressure vessels (1) (2) (3) (4) (i) (ii) (iii) (iv) (v) Not above 2000 Above 2000 but not above 10,000 Above 10,000 but not above 20,000 Above 20,000 but not above 40,000 Above 40,000 5 metres 10 metres 15 metres 20 metres 30 metres 1 metre 1 metre 1.5 metres 2 metres 2 metres\nSl.\nNos\nWater capacity of vessel(in litres)\nMinimum distance\nFrom building or group of buildings or line of\nadjoining property\nMinimum distance\nbetween pressure\nvessels\n(1)\n(2)\n(3)\n(4)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\nNot above 2000\nAbove 2000 but not above 10,000\nAbove 10,000 but not above 20,000\nAbove 20,000 but not above 40,000\nAbove 40,000\n5 metres\n10 metres\n15 metres\n20 metres\n30 metres\n1 metre\n1 metre\n1.5 metres\n2 metres\n2 metres\nTABLE 2\nMinimum safety distances for non-corrosive, non-flammable or non-toxic gases\nSl. Nos Water capacity of vessel(in litres) Minimum distance from building or group of buildings or line of adjoining property Minimum distance between pressure vessels (1) (2) (3) (4) (i) (ii) (iii) (iv) (v) Not above 2000 Above 2000 but not above 10,000 Above 10,000 but not above 20,000 Above 20,000 but not above 40,000 Above 40,000 3 metres 5 metres 7.5 metres 10 metres 15 metres 1 metre 1 metre 1.5 metres 2 metres 2 metres\nSl.\nNos\nWater capacity of vessel(in litres)\nMinimum distance from\nbuilding or group of\nbuildings or line of\nadjoining property\nMinimum distance\nbetween pressure\nvessels\n(1)\n(2)\n(3)\n(4)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\nNot above 2000\nAbove 2000 but not above 10,000\nAbove 10,000 but not above 20,000\nAbove 20,000 but not above 40,000\nAbove 40,000\n3 metres\n5 metres\n7.5 metres\n10 metres\n15 metres\n1 metre\n1 metre\n1.5 metres\n2 metres\n2 metres\nTABLE 3\nMinimum safety distances for liquefied\nflammable gases\nSl. No. Water capacity of vessel (in litres) Minimum distance from building or group of buildings or line of adjoining property Minimum distance between vessels Above ground level Underground or Aboveground vessels covered with earth(mound) Above ground level Underground or aboveground vessels covered with earth(mound) (1) (2) (3) (4) (5) (6) (i) (ii) (iii) (iv) (v) (vi) (vii) (viii) (ix) (x) Not above 2000 Above 2000 but not above 75,00 Above 75,00 but not above 10,000 Above 10,000 but not above 20,000 Above 20,000 but not above 40,000 Above 40,000 but not above 3,50,000 Above 3,50,000 but not above 4,50,000 Above 4,50,000 but not above 7,50,000 Above 7,50,000 but not above 38,00,000 Above 38,00,000 5 metres 10 metres 10 metres 15 metres 20 metres 30 metres 40 metres 60 metres 90 metres 120 metres 3 metres 3 metres 5 metres 7.5 metres 10 metres 15 metres 15 metres 15 metres 15 metres 15 metres 1 metre 1 metre 1.5 metres 2 metres 2 metres 2 metres or ¼ th of the sum of the sum of diameter of adjacent vessel or ½ the diameter of the two adjacent vessels, whichever is greater 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre 1 metre\nSl.\nNo.\nWater capacity of vessel\nMinimum distance from building or group of buildings or line of\nMinimum distance between\nAbove\nground\nlevel\nUnderground or Aboveground vessels covered\nwith\nAbove\nground\nlevel\nUnderground or aboveground\nvessels covered\nwith earth(mound)\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n(i)\n(ii)\n(iii)\n(iv)\n(v)\n(vi)\n(vii)\n(viii)\n(ix)\n(x)\nNot above 2000\nAbove 2000 but not above 75,00\nAbove 75,00 but not above 10,000\nAbove 10,000 but not above 20,000\nAbove 20,000 but not above 40,000\nAbove 40,000 but not above 3,50,000\nAbove 3,50,000 but not above 4,50,000\nAbove 4,50,000 but not above 7,50,000\nAbove 7,50,000 but not above 38,00,000\nAbove 38,00,000\n5 metres\n10 metres\n10 metres\n15 metres\n20 metres\n30 metres\n40 metres\n60 metres\n90 metres\n120 metres\n3 metres\n3 metres\n5 metres\n7.5 metres\n10 metres\n15 metres\n15 metres\n15 metres\n15 metres\n15 metres\n1 metre\n1 metre\n1.5 metres\n2 metres\n2 metres\n2 metres or ¼ th\nof the sum of\nthe sum of\ndiameter of\nadjacent vessel\nor ½ the\ndiameter of the\ntwo adjacent\nvessels,\nwhichever is\ngreater\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\n1 metre\nTABLE 4\nMinimum Safety distances (in meters) between\nfacilities associated with storage of liquefied flammable gas in petroleum\nrefinery, gas processing plants, storage terminals and bottling plants.\n(A) For Total Storage not Above 100\nTonnes\n(A) For Total Storage not Above 100\nTonnes\nFrom/To Storage Vessel Property line/ buildings not associated with storage and operation Sheds for filling storage, evacuation of cylinders Tank Truck loading/ unloading gantry Tank Wagon gantry Pump/ compres sor Shed Fire Water Pump room (1) (2) (3) (4) (5) (6) (7) (8) Storage vessel Table -3 Table - 3 30 30 50 15 60 Property line/ buildings not associated with storage and operation Table -3 ----- 30 30 50 30 -- Sheds for filling storage, evacuation of cylinders 30 30 15 30 50 15 60 Tank Truck loading/ unloading gantry 30 30 30 30 50 30 60 Tank Wagon gantry 50 50 50 50 50 30 60 Pump/compressor Shed 15 30 15 30 30 --- 60 Fire Water Pump room 60 --- 60 60 60 60 ---\nFrom/To\nStorage\nVessel\nProperty line/ buildings not\nassociated\nwith storage\nand operation\nSheds for\nfilling\nstorage,\nevacuation\nof\ncylinders\nTank Truck\nloading/\nunloading\ngantry\nTank\nWagon\ngantry\nPump/\ncompres\nsor\nShed\nFire\nWater\nPump\nroom\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\n(7)\n(8)\nStorage vessel\nTable -3\nTable - 3\n30\n30\n50\n15\n60\nProperty line/\nbuildings not\nassociated with\nstorage and\noperation\nTable -3\n-----\n30\n30\n50\n30\n--\nSheds for filling\nstorage,\nevacuation of\ncylinders\n30\n30\n15\n30\n50\n15\n60\nTank Truck\nloading/\nunloading gantry\n30\n30\n30\n30\n50\n30\n60\nTank Wagon\ngantry\n50\n50\n50\n50\n50\n30\n60\nPump/compressor\nShed\n15\n30\n15\n30\n30\n---\n60\nFire Water Pump\nroom\n60\n---\n60\n60\n60\n60\n---\n(B) For Total Storage not Above 100\nTonnes\n(B) For Total Storage not Above 100\nTonnes\nFrom/To Storage Vessel Property line/ buildings not associated with storage and operation Sheds for filling storage, evacuation of cylinders Tank truck unloading/ loading gantry Fire Water Pump room (1) (2) (3) (4) (5) (6) Storage Vessel Table-3 Table 3 Table - 3 15 30 Property line/buildings not associated with storage & operation Table-3 ----- 15 15 -- Sheds for filling storage, evacuation of cylinders Table - 3 15 15 15 30 Tank truck unloading/loading gantry 15 15 15 15 30 Fire Water Pump room 30 -- 30 30 --\nFrom/To\nStorage\nVessel\nProperty line/\nbuildings not\nassociated\nwith storage\nand operation\nSheds for filling\nstorage,\nevacuation of\ncylinders\nTank truck\nunloading/\nloading gantry\nFire\nWater\nPump\nroom\n(1)\n(2)\n(3)\n(4)\n(5)\n(6)\nStorage Vessel\nTable-3\nTable 3\nTable - 3\n15\n30\nProperty line/buildings not\nassociated with storage &\noperation\nTable-3\n-----\n15\n15\n--\nSheds for filling storage,\nevacuation of cylinders\nTable - 3\n15\n15\n15\n30\nTank truck\nunloading/loading gantry\n15\n15\n15\n15\n30\nFire Water Pump room\n30\n--\n30\n30\n--\nTABLE 5\nMinimum Safety distances (in metres) between\nfacilities associated with storage and dispensing of liquefied petroleum gas in\nliquefied Petroleum gas dispensing station as automotive fuel to motor vehicles .\nTo/ From Liquefied Petroleu mLPG Storage Vessels Fill point of LPG Storage vessel and Centre of LPG Tank-Truck unloading hard stand Liquefied petroleum gas Dispenser Property line Petroleum Class A or B service Station licensed in Form XII of Petroleum Rules 1976 Fill point of petroleum tanks Vent pipe Of petrolem tanks Petroleum Class A/B dispensig pump Liquefied petroleum gas storage vessels Table-3 9 (aboveground/ mounded vessels exceeding 7500 litres capacity) 6 (aboveground/ mounded vessels not exceeding 7500 litres capacity ) 3 (underground vessel) 15 (aboveground vessels exceeding 20,000 litres capacity) 9 (aboveground vessels not exceeding 20,000 litres capacity or underground/ mounded vessels) Table-3 9 9 9 Fill point of LPG Storage vessel and Centre of LPG Tank- Truck unloading hard stand 9 (abovegr ound/ mounded vessels exceedin g 7500 litres capacity) 6 (abovegr ound/ mounded vessels not exceeding 7500 litres capacity) 3 (underground vessel) - 6 9 6 6 6 Liquefied Petroleum Gas Dispenser 9 ( aboveground vessels not exceeding 20,000 litres capacity or underground/mounded vessels ) 15 ( aboveground vessels exceeding 20,000 litres capacity ) 6 - 6 6 6 6 Property line T able 3 9 6 - 3 4 6\nTo/ From\nLiquefied\nPetroleu\nmLPG\nStorage\nVessels\nFill point of LPG\nStorage\nvessel and Centre\nof LPG\nTank-Truck\nunloading hard\nstand\nLiquefied petroleum gas Dispenser\nProperty\nline\nPetroleum Class A or B service Station licensed in Form XII of Petroleum Rules 1976\nFill point of petroleum\ntanks\nVent pipe\nOf petrolem\ntanks\nPetroleum\nClass\nA/B\ndispensig\npump\nLiquefied petroleum gas storage vessels\nTable-3\n9 (aboveground/\nmounded\nvessels exceeding\n7500\nlitres capacity)\n6 (aboveground/\nmounded\nvessels not\nexceeding\n7500 litres\ncapacity ) 3 (underground\nvessel) 15 (aboveground vessels exceeding 20,000 litres capacity)\n9 (aboveground\nvessels not\nexceeding\n20,000 litres\ncapacity or\nunderground/\nmounded\nvessels)\nTable-3\n9\n9\n9\nFill point\nof LPG\nStorage\nvessel and\nCentre of\nLPG\nTank-\nTruck\nunloading\nhard stand\n9\n(abovegr\nound/\nmounded\nvessels\nexceedin\ng 7500\nlitres\ncapacity)\n6\n(abovegr\nound/\nmounded\nvessels not exceeding 7500 litres capacity) 3 (underground vessel)\n-\n6\n9\n6\n6\n6\nLiquefied Petroleum Gas Dispenser\n9 ( aboveground vessels not exceeding 20,000 litres capacity or underground/mounded vessels ) 15 ( aboveground vessels exceeding 20,000 litres capacity )\n6\n-\n6\n6\n6\n6\nProperty line\nT able 3\n9\n6\n-\n3\n4\n6\n[TABLE 6\nMinimum safety distances for non-flammable non\ntoxic cryogenic liquids\nWater capacity of vessel in litres Between Two vesse Between vessel and any building or adjoining property line or pedestrians passage Between vessel and flammable structure, naked flame, pipeline, containing flammable fluids, electric installation or places of public assembly or drain Not exceeding 10,000 Exceeding 10,000 1 metre 1 metre 3 metres 3 metres 5 metres 7.5 metres\nWater capacity of\nvessel in litres\nBetween\nTwo\nvesse\nBetween vessel and\nany building or\nadjoining property line\nor pedestrians\npassage\nBetween vessel and\nflammable structure,\nnaked flame, pipeline,\ncontaining flammable\nfluids, electric\ninstallation or places\nof public assembly or\ndrain\nNot exceeding 10,000\nExceeding 10,000\n1 metre\n1 metre\n3 metres\n3 metres\n5 metres\n7.5 metres\nTABLE 7\nMinimum safety distances for liquid\ncarbon-dioxide\nWater capacity of vessel in litres Between Two vessel Between vessel and any building or adjoining property line or pedestrians passage or places of public assembly Not exceeding 50,000 1 metre 2 metres Exceeding 50,000 2 metre 4 metres\nWater capacity of\nvessel in litres\nBetween\nTwo\nvessel\nBetween vessel and\nany building or\nadjoining property line\nor pedestrians\npassage or places of\npublic assembly\nNot exceeding 50,000\n1 metre\n2 metres\nExceeding 50,000\n2 metre\n4 metres\n(a) thirty metres for corrosive, toxic or flammable gases;\n(b) fifteen metres for non-corrosive, non-toxic or non-flammable gases;",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "23",
"title": "23. Foundations for pressure vessels",
"chapter": null,
"content": "(ii) The materials may be of-\n(a) brick-work masonry;\n(b) reinforced concrete; or\n(c) steel plate, steel pipe or structural steel.\n(a) Static loading; weight of vessel and its contents;\n(b) test loading if tested by water;\n(c) wind loading;\n(d) operational loading such as vibration or thermal (natural and operational).\n(ii) the spacing of vessel support shall be decided after close consideration of vessel-shell stressing and transmission of the loadings to the ground;\n(iii) the design of supports for vessels shall provide flexibility to allow for movement of the vessel as a result of pressure and thermal expansion;\n(iv) the vessel shall be securely anchored or weighed or provided with adequate pier height to avoid floatation due to flood waters;\n(v) in case of structural steel supports such supports, excluding vessel saddles or supporting feet 45 cm or less in height, shall be encased in fire-resisting materials of adequate thickness.",
"footnote": "",
"is_definition": false,
"sort_order": 21
},
{
"number": "24",
"title": "24. Fencing",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 22
},
{
"number": "25",
"title": "25. Cleanliness",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 23
},
{
"number": "26",
"title": "26. Earthing",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 24
},
{
"number": "27",
"title": "27. No smoking",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 25
},
{
"number": "28",
"title": "28. Fire protection",
"chapter": null,
"content": "[(i) provision shall be made for an adequate supply of water and fire protection in the storage area in accordance with the provision of the rules and the regulations applicable in that area. The application of water may be by hydrants, hoses and mobile equipments, fixed monitors or by fixed spray systems which may be automatic. Control of water flow should be possible from outside any danger area. The fire water system shall be designed with medium velocity sprinklers for above ground storage vessels, filling sheds, loading or unloading area, and pump sheds having minimum spray density of ten litres per minute per square metre for the single largest risk area and with additional requirements for hydrant points. In plants referred to in Table 4-A of rule 22, the quantity of water available shall be sufficient for four hours of fire fighting, and in plants referred to in Table 4-B of rule 22, the same shall be for two hours of fire fighting. For other installations not covered under Table 4-A and 4-B, the fire water storage shall be as approved by the Chief Controller;]\n(ii) hydrants, where provided, shall be readily accessible at all times and so spaced as to provide for the protection of all vessels;\n(iii) sufficient length of fire hose shall be provided and be readily available. The outlet of each hose line shall be equipped with a combination jet and fog nozzle. The hoses should be maintained well and periodically inspected;\n(iv) mobile equipment, fixed monitors or fixed spray systems shall be designed to discharge water at a rate sufficient to maintain an adequate film of water over the surface of the vessel and supports under fire conditions;\n(v) consideration shall be given to the provision of mobile or fixed water spray systems giving suitable and effective protection for vehicle loading and unloading areas;\n(vi) at least two dry chemical powder type fire extinguishers of 9 kg. capacity each shall be installed at each point of access to the installations.\n[(vii) In Liquefied Petroleum Gas dispensing station for fuelling motor vehicles, having only underground or earth covered (mounded) liquefied petroleum gas storage vessels, two numbers seventy kilograms dry chemical type fire extinguishers shall be provided. In dispensing stations having above ground liquefied petroleum gas storage vessels, hydrants with minimum water pressure of seven kilograms per square centimetre shall be provided at convenient positions for all round coverages of storage vessels and handling area, and water sprinklers with spray density of ten litres per minute per square metre shall be provided. The fire water pump shall be preferably diesel engine driven with capacity to deliver water at the rate and pressure specified above. The minimum fire water storage at the premises shall be that needed for fighting fire at least for one hour.]",
"footnote": "",
"is_definition": false,
"sort_order": 26
},
{
"number": "29",
"title": "29. Loading and unloading facilities",
"chapter": null,
"content": "(ii) design materials and construction of pumps shall be suitable for the type of gas to be handled and they shall be designed for the maximum outlet pressure to which they will be subjected to in operation;\n(iii) positive displacement pumps shall have a by pass value or other suitable protection against over pressure.\n(ii) compressors other than multi-stage compressors shall take suction from the vapour space of the vessels being filled.\n(ii) there shall be positive means of rapidly shutting-off flow, located at a safe distance from the vessel which is being filled or emptied;\n(iii) automatic alarm device to indicate the approach to maximum permissible height of automatic shut-off valves shall be used to prevent over filling.\n(ii) the hoses shall be mechanically and electrically continuous.",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
{
"number": "30",
"title": "30. Transfer operations",
"chapter": null,
"content": "(i) every vehicle shall be carefully examined at the installation to ensure that it complies in all respects with the requirements of these rules and shall be completely emptied before it is passed for filling;\n(ii) a visual check shall be made of the surroundings for unusual or dangerous situations before any filling or discharging procedure is commenced;\n(iii) warning notices, as necessary, shall be displayed;\n(iv) the receiving vessel shall be checked to ensure that it has sufficient ullage to receive quantity of gas being transferred to it;\n(v) the inter-connecting system, that is pipe work-fittings, valves or hoses, shall be checked to ensure that it is in safe working condition and that only valves and other fittings required in the transfer operations or any other operations proceeding simultaneously, are open.\n(i) the place where the vehicle is parked shall be properly levelled;\n(ii) the vehicle shall be prevented from accidental movement during the transfer operation. The parking brake of the vehicle shall be on and the engine shall remain stopped, except when it is necessary to drive the pump. Where necessary, wheel chock blocks shall be used;\n(iii) any driving units or electrical equipment not required and not specifically designed for the transfer operation shall be stopped or isolated;\n(iv) the vessel mounted on a vehicle shall be electrically bonded to the fixed installation before any flammable liquefied gas transfer operation is carried out;\n(v) before a vehicle is moved, the electrical and the liquid and vapour connections shall be disconnected, care being exercised to avoid spillage. Where wheel chock blocks have been used they shall be removed. The vehicle shall be checked to ensure that it is in safe working order and the surrounding areas checked to ensure that any liquefied flammable gas that may have leaked or has to be vented has safely dispersed.\n(i) a competent person shall remain in attendance during all the operations connected with the transfer and ensure that all the requirements of these rules are complied with;\n(ii) if it is necessary to discontinue a vehicle loading operation temporarily, the loading hose, shall be disconnected from the vehicle for the period of such discontinuance.\n(i) any leakage;\n(ii) a fire occurring in the vicinity;\n(iii) a severe electrical storm occurring in the vicinity in the case of an operation which involves venting of flammable gas.\n[30-A. Dispenser for liquefied petroleum gas dispensing station\n30-B. Special provisions for filling fuel tanks of motor vehicles and unloading of tank-truck in liquefied petroleum gas dispensing station",
"footnote": "",
"is_definition": false,
"sort_order": 28
},
{
"number": "31",
"title": "31. Electrical apparatus and installations",
"chapter": null,
"content": "(i) all electrical meters, distribution boards, switches, fuses, plugs and sockets shall be of flame proof construction complying with the requirements of IS : 2148 : 1968 and the frames shall be effectively earthed;\n(ii) all electrical fixed lamps shall be enclosed in a well glass flame proof fitting conforming to IS : 2206 (Part I) : 1962.\n[31-A. Classification of hazardous area for flammable gases\n(a) a division \"0\" area, if inflammable gases of vapours are expected to be continuously present in the area;\n(b) a division \"1\" area, if inflammable gases or vapours are likely to be present in the area under normal operating conditions; or\n(c) a division \"2\" area, if inflammable gases or vapours are likely to be present in the area only under abnormal operating conditions or failure or rupture of an equipment.\n31-B. Extent of hazardous area\n(i) Entire space within the dispenser enclosure cabinet and forty-six centimetres horizontally from the exterior of enclosure cabinet and up to an elevation of one hundred and twenty-two centimetres above dispenser base and the entire pit or open space beneath the dispenser shall be division \"1\";\n(ii) Up to forty-six centimetres vertically, above the surrounding ground level and horizontally beyond forty-six centimetres up to six metres on all sides of the dispenser enclosure cabinet shall be division \"2\".]",
"footnote": "",
"is_definition": false,
"sort_order": 29
},
{
"number": "32",
"title": "32. Lighting of storage and operating areas",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 30
},
{
"number": "33",
"title": "33. Certificate of safety",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 31
},
{
"number": "33",
"title": "CHAPTER IV",
"chapter": "CHAPTER IV",
"content": "Transport",
"footnote": "",
"is_definition": false,
"sort_order": 32
},
{
"number": "34",
"title": "34. Application",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 33
},
{
"number": "35",
"title": "35. Vehicles for transport of compressed gas",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 34
},
{
"number": "36",
"title": "36. Design",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 35
},
{
"number": "37",
"title": "37. Protection of valves and accessories",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
{
"number": "38",
"title": "38. Equipment",
"chapter": null,
"content": "(a) the maximum designed pressure of the vessel;\n(b) the super imposed pumping pressure of the shock loading caused by road movements;\n(ii) the materials used for vessel equipment shall be sufficient ductile to withstand rough usage and accidental damage. Brittle materials such as cast iron shall not be used.\n(ii) any equipment or section of piping in which liquid may be trapped shall be protected against excessive pressure caused by thermal expansion of the contents.",
"footnote": "",
"is_definition": false,
"sort_order": 37
},
{
"number": "39",
"title": "39. Vehicle design considerations",
"chapter": null,
"content": "(ii) where the fuel system is gravity-fed, a quick action cut-off-valve shall be fitted to the fuel feed pipe in an easily accessible and clearly marked position;\n(iii) the engine and exhaust system together with all electrical generators, motors, batteries, switch-gears and fuses shall be efficiently screened from the vessel or the body of the vehicle by a fire-resisting shield or by enclosure within an approved fire-resisting compartment ;\n(iv) when the equipment referred to in clauses (i), (ii) and (iii) are mounted forward of the back of the driving cab, the cab can be considered to act as an acceptable shield, provided the back, the roof and the floor of the cab, are of fire-resisting construction for the full width of the cab, without any opening in the back or roof, and that the back extends downwards to the top of the chassis;\n(v) when the cab construction does not conform to the requirements mentioned above, a separate fire-resisting shield should be installed extending upwards without any openings from the top of the chassis to the top of the vessel;\n(vi) in any case, where windows are provided in the shield, they should be fitted in fire-resisting framing with wired glass or other heat-resisting material and shall not be capable of being opened;\n(vii) when the equipment referred to in clauses (i), (ii) and (iii) are mounted to the rear of the back of the cab, it shall be contained wholly within an approved fire-resisting compartment;\n(viii) in any case where the fuel used to propel a vehicle gives off a flammable vapour at a temperature less than 650C, the fuel tank shall not be behind the shield unless the following requirements are complied with, namely:-\n(a) the fuel tank is protected from blows by stout steel guards or by the frames of the vehicle;\n(b) the fill pipe of the fuel tank of the vehicle is provided with a cover having locking arrangement;\n(c) the fuel feed apparatus placed in front of the fire-resisting shield is used to lift the contents of the fuel tank;\n(ix) where a transfer pump is driven by the engine of the vehicle, provision shall be made to stop the engine from outside the cab.\n(i) The electrical system shall have-\n(a) the battery in an easily accessible position;\n(b) a readily accessible cut-off switch of not less than 300 Amps rating;\n(c) wiring so fixed and protected as to minimise accidental damage or undue wear.\n(ii) The vessel shall be electrically continuous with the chassis.\n(iii) The vehicle shall be provided with a bonding point or bonding cable.\n(iv) Tyres shall be of the \"anti-static\" type.\n(ii) The rear of the vessel shall be protected by a robust steel bumper and this bumper shall be-\n(a) attached so that collision stresses will be transmitted to the frame work of the vehicle or, in the case of an articulated vehicle to the frame work carrying the wheels of the vessel;\n(b) situated at least 7.5 cm. to the rear of the rear-most part of the vessel;\n(c) extended on each side of the vehicle to at least the maximum width of the vessel.\n(iii) The maximum weight of the liquefied gas for which the vehicle is designed should not exceed the difference in weight between the unladen weight of the vehicle and the maximum gross weight permitted for that class of vehicle under the appropriate transport regulations.",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
{
"number": "40",
"title": "40. Marking of vehicle",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 39
},
{
"number": "41",
"title": "41. Fire protection",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
{
"number": "42",
"title": "42. Operations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 41
},
{
"number": "43",
"title": "43. Certificate of safety [in prescribed pro forma ]",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 42
},
{
"number": "44",
"title": "44. Inspection and maintenance of vehicles",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 43
},
{
"number": "45",
"title": "CHAPTER V",
"chapter": "CHAPTER V",
"content": "Licenses",
"footnote": "",
"is_definition": false,
"sort_order": 44
},
{
"number": "45",
"title": "45. License for storage of compressed gas",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
{
"number": "46",
"title": "46. Prior approval of specification and plans of vessels and premises proposed to be licensed",
"chapter": null,
"content": "(i) specifications and plans drawn to scale in triplicate clearly indicating-\n(a) the manner in which the provisions prescribed in these rules shall be complied with;\n(b) the premises proposed to be licensed, the area of which shall be distinctly coloured or otherwise marked;\n(c) the surrounding area lying within 100 metres of the edge of all facilities which are proposed to be licensed;\n(d) the position, capacity, materials of construction and ground and elevation views of all vessels, all valves and fittings, filling and discharge pumps and fire-fighting facilities where provided and all other facilities forming part of the premises proposed to be licensed; and\n(ii) a scrutiny fee of rupees one hundred paid in the manner specified in rule 11.\n[46-A. No Objection Certificate",
"footnote": "",
"is_definition": false,
"sort_order": 46
},
{
"number": "47",
"title": "47. License for transport of compressed gas",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 47
},
{
"number": "48",
"title": "48. Grant of license",
"chapter": null,
"content": "[49. Application for license\n(i) an application,-\n(a) in Form I, if the application is in respect of a license to store compressed gas in pressure vessels;\n(b) in Form II, if the application is in respect of a license to transport compressed gas in a pressure vessel by a vehicle;\n(c) in Form I-A, if the application is in respect of a license to store and dispense liquefied petroleum gas as automotive fuel;\n(ii) a certificate of safety under rule 33 or rule 43 as the case may be;\n(iii) a test and inspection certificate as required under sub-rule (2) of rule 12;\n(iv) four copies of the drawings approved by the Chief Controller under rules 35 and 46;\n(v) license fee as specified in Schedule I;\n(vi) No Objection Certificate from the District Authority in respect of storage of compressed gas in pressure vessels alongwith the site plan duly endorsed;\n(vii) copy of the Registration Certificate of the vehicle issued under Motor Vehicles Act, 1988 (59 of 1988) in respect of mobile pressure vessels for transport of compressed gas.]",
"footnote": "",
"is_definition": false,
"sort_order": 48
},
{
"number": "50",
"title": "50. Period for which licenses may be granted or renewed",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
{
"number": "51",
"title": "51. Particulars of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 50
},
{
"number": "52",
"title": "52. Power of licensing authority to alter conditions.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 51
},
{
"number": "53",
"title": "53. Prior approval necessary for alteration in the licensed premises",
"chapter": null,
"content": "(i) three copies of a properly drawn plan of the licensed premises showing in distinct colour or colours the proposed alteration and the reasons therefor;\n(ii) a scrutiny fee of rupees fifty paid in the manner specified in rule 11.",
"footnote": "",
"is_definition": false,
"sort_order": 52
},
{
"number": "54",
"title": "54. Amendment of license",
"chapter": null,
"content": "[(i) an application duly filled in and signed in Form I, or in Form I-A or in Form II, as the case may be;]\n(ii) the license sought to be amended together with the approved plans attached to it;\n(iii) where any alteration in the licensed premises has been carried out, three copies of the properly drawn plan showing the alteration sanctioned under rule 53 by the Chief Controller;\n(iv) fee for the amendment of the license as specified in sub-rule (2);\n(v) a certificate of safety, if required under rule 33.",
"footnote": "",
"is_definition": false,
"sort_order": 53
},
{
"number": "55",
"title": "55. Renewal of license",
"chapter": null,
"content": "(i) if the application with accompaniments required under sub-rule (4), is not received within the time specified in sub-rule (5), the license shall be renewed only on payment of a fee amounting to twice the fee ordinarily payable;\n(ii) if such an application with accompaniments is received by the Chief Controller after the date of expiry but not later than thirty days from that, the license may, without prejudice to any other action that may be taken in this behalf, be renewed on payment of twice the fee ordinarily payable:",
"footnote": "",
"is_definition": false,
"sort_order": 54
},
{
"number": "56",
"title": "56. Refusal of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 55
},
{
"number": "57",
"title": "57. Suspension and cancellation of license",
"chapter": null,
"content": "(i) before suspending or cancelling a license under this rule, the holder of the license shall be given an opportunity of being heard;\n(ii) the maximum period of suspension shall not exceed three months; and\n(iii) the suspension of a license shall not debar the holder of the license from applying for its renewal in accordance with the provisions of rule 55.\n(i) where the license is suspended by the Chief Controller as an interim measure for the violation of the provisions of the Act or these rules, or of any condition contained in such license or in his opinion such violation is likely to cause imminent danger to the public:\n(ii) where the license is suspended or cancelled by the Central Government, if that Government considers that in the public interest or in the interest of the security of the State the such opportunity should not be given.",
"footnote": "",
"is_definition": false,
"sort_order": 56
},
{
"number": "58",
"title": "58. Procedure on expiration, suspension or cancellation of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 57
},
{
"number": "59",
"title": "59. Appeals",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 58
},
{
"number": "60",
"title": "60. Procedure on death or disability of licensee",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 59
},
{
"number": "61",
"title": "61. Loss of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 60
},
{
"number": "62",
"title": "62. Production of license on demand",
"chapter": null,
"content": "(a) on payment of a fee of rupees five in the manner specified in rule 11 for each authenticated copy; and\n(b) on the submission of a copy or copies of the plans identical with the approved plan or plans attached to the license.\n[62-A. Compliance of instructions of licensing authority",
"footnote": "",
"is_definition": false,
"sort_order": 61
},
{
"number": "63",
"title": "63. Procedure on reports of infringement",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 62
},
{
"number": "64",
"title": "64. Executive control over authorities",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
{
"number": "65",
"title": "CHAPTER VI",
"chapter": "CHAPTER VI",
"content": "Exemption",
"footnote": "",
"is_definition": false,
"sort_order": 64
},
{
"number": "65",
"title": "65. Powers to exempt",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 65
},
{
"number": "67",
"title": "CHAPTER VII",
"chapter": "CHAPTER VII",
"content": "[ACCIDENTS AND INJURIES]",
"footnote": "",
"is_definition": false,
"sort_order": 66
},
{
"number": "66",
"title": "66. Notice of accident",
"chapter": null,
"content": "(i) to the Chief Controller by express telegram (Telegraphic Address-Explosives, Nagpur) followed within twenty-four hours by a letter giving particulars of the occurrence; and\n(ii) to the officer-in-charge of the nearest police station by the quickest route. Pending the visit of the Chief Controller, or his representative, or until instruction is received from the Chief Controller that he does not wish any further investigation or inquiry to be made, all wreckage and debris shall be left untouched except insofar as its removal may be necessary for the rescue of persons injured, and recovery of the bodies of any persons killed by the accident or in the case of railways, for the restoration of through communication.",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
{
"number": "67",
"title": "67. Inquiry into accidents",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 68
},
{
"number": "68",
"title": "68. Inquiry into more serious accidents",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 69
},
{
"number": "71",
"title": "CHAPTER VIII",
"chapter": "CHAPTER VIII",
"content": "Powers",
"footnote": "",
"is_definition": false,
"sort_order": 70
},
{
"number": "69",
"title": "69. Powers of inspection, search, seizure, detention and removal",
"chapter": null,
"content": "Officers\nAreas\n(1)\n(2)\n(2) Every facility shall be afforded to the officers specified in sub-rule (1) to ascertain that these rules are being duly observed.\nAPPENDIX - [I]\nAPPENDIX - [I]\n[See Rule 4(2)]\n(i) date from which such vessels were manufactured.\n(ii) For whom the vessels were fabricated and there approximate numbers.\n(iii) Details of the vessels manufactured.\n(ii) Details of templates or gauges provided to check or test.\n(iii) Steps taken to check the accuracy of testing and checking equipment and frequency of such checking.\n(i) Proforma of records for various tests carried out by the inspecting and certifying organisation; and\n(ii) Proforma of tests and inspection certificate issued by the independent inspecting authority.\n[ APPENDIX - II ]\nAPPENDIX - II\n[See rule 2(d) and 2(p)]\nQualification And Experience Of Inspector Or Competent Person\nSl . No. Rule under which competency is recognised Qualification and other requirements Experience for the purpose Minimum facilities 1. Rules 12(3) (1) Degree in chemical or Mechanical or Metallurgical or Marine Engineering from a recognised university or equivalent professional qualifications. (2) Physically fit and mentally sound for carrying out tests and examination. (1) A minimum experience of 10 years in design, fabrication and stage-wise inspection during fabrication of pressure vessels and equipments operating under pressure. (2) He shall be - (a) Conversant with the relevant codes of fabrication and test procedures relating to pressure vessels and their fitting. b ) Conversant with the statutory requirements concerning design and safety of unfired pressure vessels. Standard gauges and instruments conforming to national/international standards for test and examination at every stage of fabrication. Either the Inspector shall have these or these shall be available to him. The Inspector shall be responsible for ensuring the equality and accuracy of these gauges and instruments used by him. A documented system to ensure this shall be maintained by the Inspector. 2. Rule 18,19, 33, 43 & 44 (1) Degree in Chemical or Mechanical or Marine Engineering or equivalent professional qualifications. (2) Physically fit and mentally sound for carrying out tests and examinations. (1) A minimum experience of 10 years in- (a) Design and fabrication, erection, operation, maintenance and; (b) testing examination and inspection of pressure vessels or equipment operating under pressure. (2) He shall be- (a) conversant with the relevant code of practice and test procedures relating to pressure vessels; (b) conversant with statutory requirements concerning safety of unfired pressure vessels installations & transport vehicles. (c) Conversant with non-destructive testing techniques as are applicable to pressure vessels. (d) able to identify defects and arrive at a reliable conclusion, with regard to the safety of pressure vessels. Standard gauges, pumps and gadgets for hydraulic and pneumatic pressure tests, non-destructive tests, equipments for ultrasonic thickness test, ultrasonic flaw detection magnetic particle inspection and any other test that may be required by Chief Controller in specific cases. Either the Competent Person shall have these facilities or these shall be available to him. The Competent Person shall be responsible for ensuring the quality and accuracy of the gauges and equipments and the competence of any person that may be employed for performing a nondestructive test.\nSl . No.\nSl\n. No.\nRule under which competency is recognised\nRule\nunder which competency is recognised\nQualification and other requirements\nQualification and other requirements\nExperience for the purpose\nExperience for the purpose\nMinimum facilities\nMinimum facilities\n(1) Degree in chemical or Mechanical or Metallurgical or Marine Engineering from a recognised university or equivalent professional qualifications.\n(2) Physically fit and mentally sound for carrying out tests and examination.\n(1) A minimum experience of 10 years in design, fabrication and stage-wise inspection during fabrication of pressure vessels and equipments operating under pressure.\n(a) Conversant with the relevant codes of fabrication and test procedures relating to pressure vessels and their fitting.\nb ) Conversant with the statutory requirements concerning design and safety of unfired pressure vessels.\n(1) Degree in Chemical or Mechanical or Marine Engineering or equivalent professional qualifications.\n(2) Physically fit and mentally sound for carrying out tests and examinations.\n(a) Design and fabrication, erection, operation, maintenance and;\n(b) testing examination and inspection of pressure vessels or equipment operating under pressure.\n(a) conversant with the relevant code of practice and test procedures relating to pressure vessels;\n(b) conversant with statutory requirements concerning safety of unfired pressure vessels installations & transport vehicles.\n(c) Conversant with non-destructive testing techniques as are applicable to pressure vessels.\n(d) able to identify defects and arrive at a reliable conclusion, with regard to the safety of pressure vessels.\nNote.\nAPPENDIX - III\nAPPENDIX - III\n[See rule 2(p) and 11A]\nA. APPLICATION OF RECOGNITION AS COMPETENT PERSON UNDER THE STATIC AND MOBILE PRESSURE VESSELS (UNFIRED) RULES, 1981\n[See rules 18,19,33,43 & 44(2)]\n(ii) Name & qualification (of constituent members is case of organisation).\n(iii) Experience (of constituent members in case of organisation with regard to fabrication, installation, maintenance in case of transport vehicles and examination and testing of pressure vessels and various fittings and in other related fields. Please refer to requirements mentioned in column 4 of Appendix II. (Please attach documentary evidence of the experience).\n(i) maintain the facilities is good working order and calibrated periodically;\n(ii) to fulfil and abide by all the conditions stipulated in the certificate of competency and instructions issued by the Chief Controller from time to time.\n.........................................\nSignature of the Head of the organisation\nName & Designation................................\nSeal of the Institution\nB. APPLICATION FOR RECOGNITION AS AN INSPECTOR COMING UNDER THE PURVIEW OF STATIC AND MOBILE PRESSURE VESSELS(UNFIRED) RULES, 1981\n[See rules 12(2)]\n(ii) Name & qualification of its constituent members.\n(iii) Experience of the organisation and constituent members with regard to stagewise inspection during fabrication of pressure vessels and various fittings and in other related fields. Please refer to requirements mentioned in column 4 in Appendix II. (Please attached documentary evidence of the experience).\n..............................................\nSignature of the Head of the organisation\nName & Designation\nSeal of the Institution\nC. APPLICATION FOR GRANT OF CERTIFICATE OF COMPETENCY TO A PERSON FOR CERTIFYING STORAGE INSTALLATIONS OR TRANSPORT VEHICLES OWNED AND OPERATED BY THE ORGANISATION IN WHICH HE IS EMPLOYED\nName of the organisation Period of service Designation Area of responsibilities\nName of the organisation\nName of the organisation\nPeriod of service\nPeriod of service\nDesignation Area of responsibilities\nDesignation Area of responsibilities\n(a) that is the event of my leaving the aforesaid organisation, I will promptly inform the Chief Controller;\n(b) to fulfill and abide by all the conditions stipulated in the certificate of competency and instruction issued by the Chief Controller from time to time.\n..........................................\nSignature of applicant\n(a) notify the Chief Controller in case the competent person leaves our employment;\n(b) provide and maintain in good order all facilities at his dispoasal as mentioned above;\n(c) Notify the Chief Controller any charge in the facilities.\n.................................\nSignature\nName and Designation ................................\nTelephone No.........................................\nTelex No. ............................................\nOfficial Seal\n[SCHEDULE I]\n(See Rule 48)\nLICENCE FORMS, PURPOSES, LICENSING AUTHORITY AND LICENCE FEES\nSl . No. Form of licence Purpose for which granted Authority empowered to grant licence Fees (1) (2) (3) (4) (5) 1. III To store compressed gas in pressure vessels Chief Controller (a) Where the total water capacity of vessels in an installation does not exceed 5,000 litres Rs.1000.00 (b) Where the total water capacity of vessels in an installation exceeds 5,000 litres Rs.\n1,000 litres for the first 5,000 litres and for every additional 1,000 litres or part thereof Rs.500.00 subject to a maximum of Rs.\n10,000. 2. IIV To transport compressed gas in a pressure vessel by a vehicle Chief Controller Rs . 1,000 3. V To store and dispense liquefied petroleum gas in liquefied petroleum gas dispensing station as automotive fuel to motor vehicles Chief Controller Same as the licence in Form III\nSl . No.\nSl\n. No.\nForm of licence\nForm of licence\nPurpose for which granted\nPurpose for which granted\nAuthority empowered to grant licence\nAuthority empowered to grant licence\nFees\nFees\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\n(4)\n(4)\n(5)\n(5)\n1.\nIII\nChief Controller\n(a) Where the total water capacity of vessels in an installation does not exceed 5,000 litres Rs.1000.00\n(b) Where the total water capacity of vessels in an installation exceeds 5,000 litres Rs.\n1,000 litres for the first 5,000 litres and for every additional 1,000 litres or part thereof Rs.500.00 subject to a maximum of Rs.\n10,000.\n2.\nIIV\nChief Controller\nRs . 1,000\n3.\nV\nChief Controller\nSame as the licence in Form III\nSCEHDULE - II\n(See Rule 30A)\nDesign, construction, testing and maintenance of dispenser for liquefied petroleum gas dispensing station and its pipe connections :-\nDesign, construction, testing and maintenance of dispenser for liquefied petroleum gas dispensing station and its pipe connections\na) The type of the dispenser used for dispensing liquefied petroleum gas shall conform to specification and be of a type approved by the Chief Controller.\nb) The dispenser shall be provided with an excess flow valve, a remote operated shut-off valve and a pipe shear provision in that order in the liquid inlet pipe.\nc) The dispenser shall be installed on a firm foundation and protected against physical damage.\nd) A breakaway device with excess flow valves or quick action cut-off valves on both sides of the breakaway device conforming to Underwriters Laboratory, USA, specification number 567 or equivalent shall be provided on the delivery line form the dispenser before the connection of the hose so as to prevent spillage of liquefied petroleum gas from both sides of the breakaway point in the event of its breakage.\ne) The dispensing nozzle at the end of the hose shall be of self sealing type of twenty two milimetres nominal size and suitable for matching with filler connection of cylinders fitted to vehicles as fuel tanks, as specified in Australian specification AS-1425 or other established standard approved by the Chief Controller.\nf) The hose for delivery of liquefied petroleum gas by the dispenser to motor vehicles shall be suitable for commercial propane. The design pressure of the hose shall be minimum thirty two kilograms per square centimeters with a safety factor of five and shall be tested at one and half times of the design pressure at an interval not exceeding one year. The hose shall be electrically and mechanically continuous.\ng) The length of the hose connected to the dispenser shall not exceed five meters and fifty centimeters.\nh) Clearly identified switches and circuit breakers shall be provided at easily accessible location not less than six meters away from the dispenser to cut-off power supply in the event of fire, accident or other emergency. The switches or circuit breakers shall be visible from point of dispensing liquefied petroleum gas to motor vehicles.\ni) Every dispensing unit from which liquefied petroleum gas introduced into the cylinders fitted to the motor vehicles, shall be equipped with self sealing type fuelling nozzle form which the liquid released on disconnection shall not exceed fifteen millimetres.\nj) All metallic liquefied petroleum gas pipings shall be rated for Propane and designed to American Standard ASME-B-31.3 with minimum design pressure of thirty two kilogrames per square centimeters with a factor of safety of four. The materials of pipe shall be low carbon or alloy-steel conforming to American Standard ASTM-SA-333 grade 6, or SA-106 grade B Schedule 80, or API-5L or equivalent. The pipeline shall be tested at one and half times of pressure if pneumatically tested. Joints of pipeline above forty millimeters diameter shall be welded or flanged. Threaded or screwed connection shall not be provided except for special fittings like excess flow valve, pump connections upto fifty millimeters.\nFORM - I\nFORM - I\n(See Rules 49, 54 and 55)\nAPPLICATION FOR THE GRANT, AMENDMENT OR RENEWAL OF A LICENCE TO STORE COMPRESSED GAS IN VESSEL OR VESSELS\nDocuments listed overleaf must be enclosed with this application it is for the grant of a licence in Form -III",
"footnote": "",
"is_definition": false,
"sort_order": 71
},
{
"number": "1",
"title": "1. Applicant's name** The replies to be given in this column. Applicant's calling _________________________________ Applicant's Full postal address _________________________________ 2. Situation of the premises where liquefied petroleum gas is to be stored. _________________________________ State _________________________________ District _________________________________ Town or Village _________________________________ Nearest Railway Station _________________________________ 3. Nature of comp",
"chapter": null,
"content": "Applicant's calling\nApplicant's Full postal address\nState\nDistrict\nTown or Village\nNearest Railway Station\n(Please state whether flammable, corrosive or toxic.)\n............................................ Signature & designation of the applicant. Date of Application\nSignature & designation of the applicant.\nDocuments required to be submitted with application for a licence in Form - III\n(i) Four copies of specification and plans approved under Rule 46.\n(NOT REQUIRED FOR RENEWAL OF A LICENCE WITHOUT AMENDMENT).\n(ii) Licence together with approved plans and specifications attached thereto.\n(NOT REQUIRED FOR THE FIRST GRANT OF A LICENCE).\n(iii) Requisite amount of fee for the grant or amendment of a licence paid in the manner specified in Rule 11.\n(iv) A certificate of safety is required under Rule 33.\nFORM - I-A\nFORM - I-A\n(See Rules 49, 54 and 55)\nAPPLICATION FOR THE GRANT, AMENDMENT OR RENEWAL OF A LICENCE TO STORE AND DISPENSE LIQUEFIED PETROLEUM GAS IN LIQUEFIED PETROLEUM GAS DISPENSING STATION AS AUTOMOTIVE FUEL TO MOTOR VEHICLES\nDocuments listed overleaf must be enclosed with this application it is for the grant of a licence in Form-V\nDocuments listed overleaf must be enclosed with this application it is for the grant of a licence in Form-V\nii) Quantity of Petroleum already stored, if any\n......................................\nSignature & designation of the applicant.\nDocuments required to be submitted with application for a licence in Form - V\nDocuments required to be submitted with application for a licence in Form - V\n(i) Four copies of specification and plans approved under Rule 46. (Not required for renewal of a licence without amendment);\n(ii) Specification with certificates of dispenser, pipings, hoses and other fittings.(required for grant or amendment of licence)\n(iii) Licence together with approved plans and specifications attached thereto.(Not required for the first grant of a licence)\n(iv) Fee for the grant, amendment or renewal of a licence specified under the scheduled, sub rule (2) of rule 54 and sub-rule (7) of rule 55, as the case may be, to be paid in the manner specified in Rule 11.\n(v) A certificate of safety under Rule 33 (not required for renewal of licence)]\nFORM - II\nFORM - II\n(See Rules 49 and 54)\nAPPLICATION FOR THE GRANT OR AMENDMENT OF A LICENCE TO TRANSPORT COMPRESSED GAS IN A VEHICLE\nDocuments listed overleaf must be submitted with this application\nDocuments listed overleaf must be submitted with this application\nTo be filled in and signed by the applicant. 1. Applicant's name and full postal address ________________________________________________________________ 2. Particulars of the vehicle in which compressed gas is proposed to be transported (i) Make and Model ________________________________________________________________ (ii) Engine number ________________________________________________________________ (iii) Chassis number ________________________________________________________________ (iv) Registered number ________________________________________________________________ (v) Date upto which the vehicle is registered ________________________________________________________________ (vi) Name and full postal address of the registered owner ________________________________________________________________ 3. Name of the compressed gas proposed to be transported (Please state whether flammable, corrosive or toxic). 4. Chemical name of compressed gas to be transported in the vehicle 5. Water capacity of the pressure vessel and net weight of the compressed gas proposed to be transported. 6. Number and date of approval of the design drawing of the vehicle by the Chief Controller ________________________________________________________________ 7. Does (vehicle described above) fully conform to the requirements laid down in the rules and the design drawing approved by the Chief Controller. ________________________________________________________________ 8. Full postal address of the place where the vehicle will be normally stationed. ________________________________________________________________\n(i) Make and Model\n(ii) Engine number\n(iii) Chassis number\n(iv) Registered number\n(v) Date upto which the vehicle is registered\n(vi) Name and full postal address of the registered owner",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
{
"number": "7",
"title": "7. Does (vehicle described above) fully conform to the requirements laid down in the rules and the design drawing approved by the Chief Controller.",
"chapter": null,
"content": "..................................\nSignature of applicant\nDocuments required to be submitted with this appliction\nDocuments required to be submitted with this appliction\n(1) Two copies of drawing approved under Rule 35.\n(2) Safety certificate required under Rule 43.\n(3) Expired licence, if the vehicle was previously licensed.\n(4) Required amount of fee paid in the manner specified in Rule 11.\nFORM III\nFORM III\n(See Rules 49 and 50)\nLICENCE TO STORE COMPRESSED GAS IN PRESSURE VESSEL OR VESSELS\nFee Rs. ...........................\nChief Controller of Explosives\nDescription and location of the licensed premises\nDescription and location of the licensed premises\n(a) Flammable/Corrosive/Toxic gases ________________\n(b) non-toxic Gases ______________________________\nSpace for Endorsement or Renewals The licence shall be renewable without any concession in fee for three years in the absence of contravention of the provisions of the Indian Explosives Act, 1884, or the Static and Mobile Pressure Vessels (Unfired) Rules, 1981 framed there under or of the conditions of the licence. Date of renewal Date of expiry Signature and office stamp of licensing authority _________________________________ _________________________________ _________________________________ _________________________________ _________________________________ _________________________________\nSpace for Endorsement or Renewals\nSpace for Endorsement or Renewals\nDate of renewal\nDate of expiry\nSignature and office stamp of licensing authority\n_________________________________\n_________________________________\n_________________________________\n_________________________________\n_________________________________\n_________________________________\nDocuments required to be submitted with this appliction\nDocuments required to be submitted with this appliction\n(1) Two copies of drawing approved under Rule 35.\n(2) Safety certificate required under Rule 43.\n(3) Expired licence, if the vehicle was previously licensed.\n(4) Required amount of fee paid in the manner specified in Rule 11.\nFORM III\nFORM III\n(See Rules 49 and 50)\nLICENCE TO STORE COMPRESSED GAS IN PRESSURE VESSEL OR VESSELS\nFee Rs. ...........................\nChief Controller of Explosives\nDescription and location of the licensed premises\nDescription and location of the licensed premises\n(a) Flammable/Corrosive/Toxic gases ________________\n(b) non-toxic Gases ______________________________\nSpace for Endorsement or Renewals The licence shall be renewable without any concession in fee for three years in the absence of contravention of the provisions of the Indian Explosives Act, 1884, or the Static and Mobile Pressure Vessels (Unfired) Rules, 1981 framed there under or of the conditions of the licence. Date of renewal Date of expiry Signature and office stamp of licensing authority _________________________________ _________________________________ _________________________________ _________________________________ _________________________________ _________________________________\nSpace for Endorsement or Renewals\nSpace for Endorsement or Renewals\nDate of renewal\nDate of expiry\nSignature and office stamp of licensing authority\n_________________________________\n_________________________________\n_________________________________\n_________________________________\n_________________________________\n_________________________________\nConditions\nConditions\ni) As per Table-4(A) or Table-4(B), as the case may be, in case of refinery, terminal and cylinder filling plants for flammable liquefied gases\nii) Four metres and fifty centimeters in case of non-corrosive, non-toxic and non-flammable gases;\niii) Nine meters in all other cases\n[ FORM - IV ]\nFORM - IV\n(See rules 49 and 50)\nLICENCE TO TRANSPORT COMPRESSED GAS IN A PRESSURE VESSEL BY A VEHICLE\nFee Rs.......................\nChief Controller of Explosives\nDESCRIPTION OF THE VEHICLE Make and Model\n_________________________ Engine Number _________________________ Chassis Number\n_________________________ Registration Number _____________________ Name of the registered owner______________________________________________________________________________________________________________________________________________________ Chemical name of the compressed gas to be carried in the Vehicle_______________________________________________________________________________________________________________________ Authorised carrying capacity of the container_________________________________________________________________________________________________________________________________________\nDESCRIPTION OF THE VEHICLE\nDESCRIPTION OF THE VEHICLE\nEngine Number _________________________\nRegistration Number _____________________\nEndorsement of Renewals Date of Renewal Date of Expiry Signature and office Stamp of the Licensing Authority\nEndorsement of Renewals\nEndorsement of Renewals\nDate of Renewal\nDate of Renewal\nDate of Expiry\nDate of Expiry\nSignature and office Stamp of the Licensing Authority\nSignature and office Stamp of the Licensing Authority\n[ FORM - V ]\nFORM - V\n(See rules 49 and 50)\nLICENCE TO STORE AND DISPENSE LIQUEFIED PETROLEUM GAS IN LIQUEFIED PETROLEUM GAS DISPENSING STATION AS AUTOMOTIVE FUEL TO MOTOR VEHICLES\nFee Rs. .......................................\nChief Controller of Explosives\nDescription of location and facilities of the licensed premises\nDescription of location and facilities of the licensed premises\ni) Storage vessels________________________________________________________________ (Identification number and water capacity) (specify whether aboveground, mounded or underground)\nii)____________________numbers dispensers, make________________\niii) other facilities_________________________\nSpace for endorsement of renewals The licence shall be renewable without any concession in fee for three years in the absence of contravention of the provisions of the Indian Explosives Act, 1884 or the Static and Mobile Pressure Vessels\n(Unfired) Rules, 1981 framed there under, or of the condition of the license. Date of Renewal Date of Expiry Signature and Office Stamp of the Licensing Authority ____________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________\nSpace for endorsement of renewals\nSpace for endorsement of renewals\nDate of Renewal\nDate of Expiry\nSignature and Office Stamp of the Licensing Authority\n____________________________________\n____________________________________\n____________________________________\n____________________________________\n____________________________________\n____________________________________\nConditions\nConditions\n(a) It shall be provided with an excess flow valve, a remote operated shut-off valve and pipe shear provision in the liquid inlet pipe.\n(b) The dispenser shall be installed on a firm foundation and protected against physical damage.\n(c) A breakaway device with excess flow valves or quick action cut-off valves on both sides of the breakaway device conforming to Underwriters Laboratory USA, specification no 567 or equivalent shall be provided on the delivery line from the dispenser before the connection of the hose so as to prevent spillage of liquefied petroleum gas from both sides of the breakaway point in the event of its breakage.\n(a) Entire space with in the dispenser enclosure cabinet and forty six centimeters horizontally from the exterior of enclosure cabinet and upto an elevation of one hundred and twenty one entimeters above dispenser base and the entire pit or open space beneath the dispenser shall be Division-2.\n(b) Upto forty six centimeters vertically above the surrounding ground level and horizontally beyond forty six centimeters upto six meters on all sides of the dispenser enclosure cabinet shall be Division-2.",
"footnote": "",
"is_definition": false,
"sort_order": 73
}
],
"metadata": {
"Act ID": "19/859",
"Act Number": "Published vide G.S.R. 45(E), dated 4.2.1981, published in the Gazette of India, Extraordinary, Part II, Section 3(i), dated 4.2.1981, pp. 112-126, as corrected by G.S.R. 209, dated 25.2.1983.",
"Enactment Date": "",
"Act Year": "1981",
"Short Title": "The Static And Mobile Pressure Vessels (Unfired) Rules, 1981",
"Type": "CENTRAL",
"Location": "India (Central)"
},
"updated_at": "2026-09-29 21:55:18"
}