58. Precautions after occurrence of a blowout.

(a) a competent person is present on the spot throughout;
(b) an area within five hundred metre of the well on the down wind direction is demarcated as danger zone, and-
(i) all electrical installations within the danger zone is de-energised to prevent the ignition;
(ii) flameproof or intrinsically safe lamp or torch is only be used within the danger zone; and
(iii) no naked light or vehicular traffic is permitted within the danger zone;
(c) a competent person ascertains the condition of ventilation and presence of gas with a flameproof or intrinsically safe instrument so far as safety of person is concerned;
(d) adequate number of self-contained breathing apparatus or any other apparatus of such make in accordance with the standards, that is, IS 10245 Part-2 or IS 10245 Part 1 of the Bureau of Indian Standards or its revised versions are available at or near the place for use in emergency; and
(e) adequate fire-fighting facility is kept readily available for immediate use.