    "act_title": "The Oil Mines Regulations, 2017",
    "act_slug": "the-oil-mines-regulations-2017",
    "section_label": "Section",
    "section": {
        "number": "58",
        "title": "58. Precautions after occurrence of a blowout.",
        "chapter": null,
        "content": "(a) a competent person is present on the spot throughout;\n(b) an area within five hundred metre of the well on the down wind direction is demarcated as danger zone, and-\n(i) all electrical installations within the danger zone is de-energised to prevent the ignition;\n(ii) flameproof or intrinsically safe lamp or torch is only be used within the danger zone; and\n(iii) no naked light or vehicular traffic is permitted within the danger zone;\n(c) a competent person ascertains the condition of ventilation and presence of gas with a flameproof or intrinsically safe instrument so far as safety of person is concerned;\n(d) adequate number of self-contained breathing apparatus or any other apparatus of such make in accordance with the standards, that is, IS 10245 Part-2 or IS 10245 Part 1 of the Bureau of Indian Standards or its revised versions are available at or near the place for use in emergency; and\n(e) adequate fire-fighting facility is kept readily available for immediate use.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 57
    },
    "prev_section": "57",
    "next_section": "59"
}