(a) the raising and installation of heavy load is performed during daylight hours unless adequate general lighting arrangement is provided at the place of work;
(b) every loose part and tool of the rig is securely fastened;
(c) guy lines, cat lines, snub lines and such other lines are not installed within six metre of any electric overhead transmission lines;
(d) the exhaust of internal combustion engine is provided with water quench or other effective spark arrestors;
(e) high pressure circulating fluid line and steam line are securely anchored;
(f) during rigging-up and rig dismantling, the wellhead is protected against damage from sliding or falling objects of the rig and associated material;
(g) the components from a loft including nuts, bolts and cleats are lowered safely to the ground either singly, bundled or in containers; and
(h) the code of practice for rigging-up and dismantling is framed and implemented and kept updated by a deputy manager or an installation manager authorised in this behalf.
Section 50 • The Oil Mines Regulations, 2017
50. Rigging-up and rig dismantling.
the-oil-mines-regulations-2017-sec-50.json
•
Section 50
{
"act_title": "The Oil Mines Regulations, 2017",
"act_slug": "the-oil-mines-regulations-2017",
"section_label": "Section",
"section": {
"number": "50",
"title": "50. Rigging-up and rig dismantling.",
"chapter": null,
"content": "(a) the raising and installation of heavy load is performed during daylight hours unless adequate general lighting arrangement is provided at the place of work;\n(b) every loose part and tool of the rig is securely fastened;\n(c) guy lines, cat lines, snub lines and such other lines are not installed within six metre of any electric overhead transmission lines;\n(d) the exhaust of internal combustion engine is provided with water quench or other effective spark arrestors;\n(e) high pressure circulating fluid line and steam line are securely anchored;\n(f) during rigging-up and rig dismantling, the wellhead is protected against damage from sliding or falling objects of the rig and associated material;\n(g) the components from a loft including nuts, bolts and cleats are lowered safely to the ground either singly, bundled or in containers; and\n(h) the code of practice for rigging-up and dismantling is framed and implemented and kept updated by a deputy manager or an installation manager authorised in this behalf.",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
"prev_section": "49",
"next_section": "51"
}