Assam Notified Urban Areas (Other than Guwahati) Building Rules, 2014
Assam Notified Urban Areas (Other than Guwahati) Building Rules, 2014
Sections
1. Short title, extent, application and commencement.
Section 12. Definitions.
Section 23. Notice.
Section 34. Information accompanying application.
Section 45. Size of Drawing Sheets and Colour of Plans.
Section 56. Plans to be submitted for building application.
Section 67. Layout Planin-case of Land Sub-division.
Section 78. Landscape Plan.
Section 89. Building Plan.
Section 910. Building Plan for Multi-storeyed Buildings / Special Buildings.
Section 1011. Services Plan and Water Supply provisions.
Section 1112. Signing of Plans.
Section 1213. Notice for alteration.
Section 1314. Repairs.
Section 1415. Deviation during construction.
Section 1516. Withdrawal of notice.
Section 1617. Inspection on submission of application.
Section 1718. Fees for permission.
Section 1819. Grant of Permit or Refusal.
Section 1920. Duration of sanction.
Section 2021. Revocation of Permit.
Section 2122. Notice for Inspection on work commencement.
Section 2223. Completion Certificate.
Section 2324. Occupancy Certificate.
Section 2425. Part Occupancy Certificate.
Section 2526. Existing Buildings.
Section 2627. Modification of plans.
Section 2728. Correspondence.
Section 2829. Qualification and competence.
Section 2930. Debarring or black-listing professionals indulged in professional misconduct.
Section 3031. Provision to ensure compliance of sanctioned plan, etc.
Section 3132. Un-authorised Construction.
Section 3233. Pre-code Building Permit.
Section 3334. Foundation and Structural design.
Section 3435. Site Specification.
Section 3536. Means of access.
Section 3637. Plinth.
Section 3738. Floor.
Section 3839. Brick Wall.
Section 3940. Wattle created wall.
Section 4041. Boundary wall/Compound wall.
Section 4142. Number of rooms.
Section 4243. Minimum sizes of rooms.
Section 4344. Slope of pitched roofs.
Section 4445. Latrines and Lavatories (in general).
Section 4546. Served Latrine.
Section 4647. Septic tanks.
Section 4748. Location of Septic Tank's Sub-surface Absorption System.
Section 4849. Requirements of Septic tank.
Section 4950. Bathrooms.
Section 5051. Kitchen.
Section 5152. Open space for ventilation.
Section 5253. Ventilation of rooms.
Section 5354. Height Regulation.
Section 5455. Corridors and Passage.
Section 5556. Post, Post plate, Truss etc .
Section 5657. Water supply.
Section 5758. Standard for RCC wells for drinking water.
Section 5859. Basement.
Section 5960. Numbering of houses.
Section 6061. Barrier-free building.
Section 6162. Electricity and Telephone Connection.
Section 6263. Staircases.
Section 6364. Layout and open space.
Section 6465. Parking space.
Section 6566. Regulation for Residential use.
Section 6667. Regulation for commercial buildings.
Section 6768. Regulations for buildings to be used for Whole Sale purposes shall be as follows.
Section 6869. Regulation for Public and Semi Public Use Buildings shall be as follows.
Section 6970. Regulation for Industrial Buildings shall be as follows.
Section 7071. Regulation for Special Use Buildings shall be as specified below.
Section 7172. Regulations for development of U- type building.
Section 7273. Minimum plot size of builders other than Apartments.
Section 7374. FAR, Coverage and width of access.
Section 7475. Additional Area Calculations.
Section 7576. Additional Requirement for Multi-storeyed and Special Buildings.
Section 7677. Cinemas, Theatres and Assembly Hall.
Section 7778. Factories and building of the ware house class.
Section 7879. Special regulations for construction in hilly areas.
Section 7980. Environmental aspects and landscaping.
Section 8081. Earmarking/reservation of Dwelling Units (DU) for Economically Weaker Section (EWS)/Low Income Group (LIG).
Section 8182. Conservation and Harvesting of Rain water.
Section 8283. Re-use of Recycled/Waste Water.
Section 8384. Regular notification/updates.
Section 8485. Additional FAR scheme for widening of roads and improvement of junction.
Section 8586. Structural design.
Section 8687. For General Structural Safety.
Section 8788. For Cyclone/Wind Storm Protection.
Section 8889. For earthquake protection.
Section 8990. For protection from Landslide Hazard.
Section 9091. Structural Design Basis Report.
Section 9192. Seismic Strengthening and Retrofitting.
Section 9293. Review of Structural Design.
Section 9394. Certification regarding structural safety in design.
Section 9495. Constructional Safety.
Section 9596. Quality Control and Inspection.
Section 9697. Control of Signs (hoardings), transmission tower, telephone tower and outdoor display structures.
Section 9798. Maintenance of Buildings.
Section 9899. Protective Measures in Natural Hazard-Prone Areas.
Section 99100. Green Building Criteria.
Section 100101. Essential requirements.
Section 101102. Requirements for registration and competence of professionals.
Section 102103. Builder/ Constructor entity.
Section 103104. Group or Agency.
Section 104105. Annual Rate of License/ Enrolment Fees of Technical Personnel.
Section 105106. Procedure for Application or License/ Enrolment in the Authority.
Section 106107. Duties and responsibilities of Licensed Technical Personnel.
Section 107108. Penal action against defaulting Architects/ Engineers/ Groups/ Supervisors.
Section 1081. The site to be shown to the concern Zonal Engineer within 7 days.
Section 12. You are to contact to office counter of the building permission branch within 30 (thirty) days from the date of submission for further information.
Section 21. This Permit shall remain valid up to two years only from the date of issue of the permit.
Section 12. The Permit is not transferable.
Section 23. The owner upon commencement of his work under a no-objection certificate shall give Notice to MB/TC that he has started his work and Authority shall cause inspection of the work to be made within 14 days following receipt of notice to verify that the building has been erected in accordance with the sanctioned plans.
Section 34. Shall the MB/TC determine at any stage that the layout or the construction is not proceeding according to the sanctioned plan or is in violation of any provision of the Act, it shall serve a notice on the applicant requiring him to stay further execution until correction has been made in accordance with the approved plan.
Section 45. If the Permit holder fails to comply with the requirements at any stage of construction the MB/TC is empowered to cancel the building permit issued.
Section 56. Every person who erects or re-erects any building shall within one month of the completion of the work deliver to the MB/TC a notice in writing of such completion and shall give him all necessary facilities for the inspection of such works as provided in the Building Bye-laws.
Section 67. Whenever asked by the MB/TC or his subordinates, the Permit holder shall produce the Permit along with the copy of the approved plan for verification.
Section 78. In the event of reclamation of the plot for construction of building/boundary wall the reclamation level shall not exceed the level of the nearest P.W.D. or MB/TC Road. For preparation of hilly land for construction, retaining wall has to be constructed on the excavated earth and spoils shall be adequately guarded to prevent erosion.
Section 82. N.O.C. from Director of FIRE Service is to obtained for the building.
Section 23. Necessary fire fighting facilities are to be provided in and around the building.
Section 34. The Road side drain along with the Road is to be constructed at the cost of the builder connecting main outlet of the area.
Section 45. Before installation of Deep Tube Well, N.O.C. from Central Ground Water Board is to be obtained.
Section 57. At least 2 nos. of DUST BIN are to be placed near the plot at the cost of the builder.
Section 78. Planning of minimum 10 nos. of evergreen trees inside the plot on the date of commencement of construction and be maintained.
Section 89. The owner through the licensed architect, engineer, as the case may be (RTP) who has supervised the construction, shall give notice to the Authority regarding completion of work and obtain "Occupancy Certificate" before occupying the building.
Section 91. The building/s has/have been constructed according to the sanctioned plan.
Section 12. The building/s has/have been constructed as per approved plan and design as per detailed architectural drawings and specifications prepared by Architect on Record.
Section 23. Construction has been done under our supervision / guidance and adheres to the drawings submitted.
Section 31. The building/s has/have been constructed according to the sanctioned plan.
Section 12. The building/s has/have been constructed as per
Section 23. All materials used in the construction have been tested as provided in specifications and a record of test reports has been kept.
Section 31. Design
Section 12. Foundation
Section 21. Location of Building
Section 12. Details of completed work floor wise
Section 23. Enclosed : As-built plan
Section 3
assam-notified-urban-areas-other-than-guwahati-building-rules-2014-2014.json
•
136 Sections
•
Assam
{
"id": 15083,
"slug": "assam-notified-urban-areas-other-than-guwahati-building-rules-2014-2014",
"title": "Assam Notified Urban Areas (Other than Guwahati) Building Rules, 2014",
"short_title": "Assam Notified Urban Areas (Other than Guwahati) Building Rules, 2014",
"act_number": "Published vide Notification No. UDD(T)42/2008/vol-",
"act_year": 2014,
"act_type": "STATE",
"location": "Assam",
"law_status": "unknown",
"enactment_date": null,
"description": "Assam Notified Urban Areas (Other than Guwahati) Building Rules, 2014",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "1. Short title, extent, application and commencement.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "2",
"title": "2. Definitions.",
"chapter": null,
"content": "(1) \"Act\" means the Assam Municipal Act, 1956 (Assam Act no 15 of 1957) and the Assam Town and Country Planning Act, 1959 (Assam Act no 2 of 1960), according to the context of the matter respectively.\n(2) \"advertising sign\" means any surface or structure with characters, letters or illustrations applied thereto and displayed in any manner whatsoever outdoors for the purpose of advertising or giving information or to attract the public to any place, person, public performance, article, or merchandise, and which surface or structure is attached to, forms part of, or is connected with any building or is fixed to a tree or to the ground or to any pole, screen, fence or hoarding or displayed in space, or over any water body included in the jurisdiction of the Authority ;\n(3) \"ancient monuments\" mean the ancient monument as defined in the Ancient Monuments and Records Act,1959 and The Ancient Monuments and Archaeological Sites and Remains Act,1958, respectively ;\n(4) \"atrium\" means a sky lighted central area, often containing plants, especially for common area;\n(5) \"authority\" shall mean local, regional or any other Authority appointed by the State Government for the purpose of administering these rules. Unless otherwise appointed by the State Government, the Authority in the case of a notified Municipal area shall mean the Town Committee, the Municipal Board or the Municipal Corporation as may be constituted from time to time under the provisions of the Assam Municipal Act, 1956 (Assam Act 15 of 1957) and in case of Master Plan area, other than notified Municipal area, shall mean the Development Authority constituted for that area under the provisions of the Assam Town and Country Planning Act,1959 (Assam Act 2 of 1960) ;\n(6) \"application\" means an application made in such form as may be prescribed by the Authority from time to time ;\n(7) \"area\" in relation to a building means the superficies of a horizontal section thereof made at the plinth level inclusive of the external walls and of such portions of the partition walls as belonging to the building ;\n(8) \"air-conditioning\" means a process of treating air to control simultaneously its temperature, humidity, cleanliness and distribution to meet the requirement of an enclosed space;\n(9) \"amenity\" means and includes roads, street, open spaces, parks, recreational grounds, play grounds, gardens, water supply, electric supply, street lighting, sewerage, drainage, public works and other utilities, services and conveniences ;\n(10) \"balcony\" means horizontal projection, cantilevered or otherwise including a parapet handrail, balustrade, to serve as a passage or sit out place ;\n(11) \"barsati\" means a habitable room/rooms on the roof of the building with or without toilet/kitchen;\n(12) \"basement or cellar\" means the lower storey of a building, below or partly below the ground level consisting of one or more levels ;\n(13) \"black waste water\" means waste water discharged by the water closet, urinals and municipal solid wastes ;\n(14) \"building\" means a structure constructed with any materials whatsoever for any purpose, whether used for human habitation or not, and includes, -\n(a) foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms, etc.\n(b) verandahs, balconies, cornices, projections etc;\n(c) parts of a building or anything affixed thereto;\n(d) any wall enclosing or intended to enclose any land or space, sign and outdoor display structures, etc:\n(15) \"building height\" means the vertical distance measured in the case of flat roofs from the average level of ground around and contiguous to the building, or as decided by Authority, to the terrace of last habitable floor of the building adjacent to external wall and in the case of pitched roofs, up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof, and in the case of gabbles facing the road, the mid-point between the eaves level and the ridge. The architectural features serving no other function except that of decoration shall be excluded for the purpose of taking heights. If the building does not abut street, the height shall be measured above the average level of the ground around and contiguous to the building. For hilly areas, the vertical distance shall be measured from the lower floor level instead of average ground level as applicable in case of plain ;\n(16) \"building line\" means a line which is in rear of the street alignment and to which the main wall of a building abutting on a street may lawfully extend and beyond which no portion of the building may extend except as prescribed in these rules;\n(17) \"cabin\" means a non-residential enclosure constructed of non-load bearing partitions;\n(18) \"canopy\" mean a cantilevered projection from the face of the wall over an entry to the building at the lintel or slab level provided that , -\n(a) it shall not project beyond the plot line ;\n(b) it shall not be lower than 2.3 m when measured from the ground;\n(c) there shall be no structure on it and the top shall remain open to sky;\n(19) \"chimney\" means a construction by means of which a flue is formed for the purpose of carrying products of combustion to the open air and includes a chimney stack and flue pipe;\n(20) \"chajja\" means a sloping or horizontal structural overhang provided over openings on external walls for protection from the weather ;\n(21) \"conversion\" means the change from one occupancy to another occupancy or any change in building structure or part thereof resulting in a change of space or use requiring additional occupancy certificate;\n(22) \"courtyard\" means a space permanently open to sky, enclosed fully or partially by buildings and may be at ground level or any other level within or adjacent to a building;\n(23) \"covered area\" means the ground area covered immediately above the plinth level covered by the building but does not include the space covered by, -\n(a) garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, with open top and unenclosed on sides by walls and the like;\n(b) drainage culvert, conduit, catch-pit, gully-pit, chamber, gutter and the like; and\n(c) compound wall, gate, slide/swing door, canopy, and areas covered by chajja or similar projections and staircases which are uncovered and open at least on three sides and also open to sky;\n(24) \"cornice\" means a slopping or horizontal structural overhang usually provided over openings or external surface to provide protection from sun and rain;\n(25) \"damp proof course\" means a course consisting of some appropriate water proofing material provided to prevent penetration of dampness or moisture;\n(26) \"drain\" means any conduit or channel for the carriage of sewage and sewage water, storm water from one building or a portion of the building;\n(27) \"drainage\" means a system constructed for the purpose of removal of wastewater;\n(28) \"dwelling\" means a building or a portion thereof which is designed or used wholly or principally for residential purposes for one family;\n(29) \"enclosed staircase\" means a staircase separated by the fire resistant walls and doors from the rest of the building;\n(30) \"existing building\" means a building or structure existing authorisedly with the approval of the Authority before the commencement of these rules;\n(31) \"existing use\" means use of a building or structure existing authorisedly with the approval of the Authority before the commencement of these rules;\n(32) \"external wall\" means an outer wall of a building, not being a partition wall even though adjoining to a wall of another building and also means a wall abutting on an interior open space of any building;\n(33) \"exit\" means a passage channel or means of egress from the building, its floor to a street or other open space of safety, whether horizontal, outside and vertical exits as under,-\n(i) \"horizontal exit\" means an exit, which is a protected opening through or around a fire well or bridge connecting two or more buildings;\n(ii) \"outside exit\" means an exit from building to a public way to an open area leading to a public way or to enclose a fire resistant passage leading to a public way;\n(iii) \"vertical exit\" means an exit used for ascending or descending between two or more levels including stair way, fire towers, ramps and fire escapes;\n(34) \"Economically Weaker Section(EWS) Housing\" means apartments or multi-storeyed house specifically developed for providing residential accommodation to the families belonging to the income groups viz., Economically Weaker Sections (EWS) with monthly income of Rs.3300 per month or as per criteria laid down by Government of India from time to time;\n(35) \"Lower income Group (LIG) Housing\" means apartments or multi-storeyed house specifically developed for providing residential accommodation to the families belonging to the income groups viz. Lower Income Group with annual household income of Rs.3300 to Rs.7000 per month or as per criteria laid down by Government of India from time to time;\n(36) \"fire and / or emergency alarm system\" means an arrangement of call points or detectors, sounders and other equipment for the transmission and indication of alarm signals working automatically or manually in the event of fire;\n(37) \"fire lift\" means a special lift designed for the use of fire service personal in the event of fire or other emergency;\n(38) \"fire-proof door\" means a door or shutter fitted to a wall opening, and constructed and erected with the requirement to check the transmission of heat and fire for a period;\n(39) \"fire pump\" means a machine, driven by external power for transmitting energy to fluids by coupling the pump to a suitable engine or motor, which may have varying out puts / capacity but shall be capable of having a pressure of 3.2 kg / cm2 at the top most level of multi storey or high rise building;\n(40) \"fire pump / booster fire pump\" means a mechanical / electrical device that boots up the water pressure at the top level of a multi storeyed / high rise building and which is capable of a pressure of 3.2 kg / cm 2 at the nearest point;\n(41) \"fire resistance\" means the time during which a fire resistance (Retardant) paint, which is one of the materials having certain degree of fire resistance, can contribute in the fire safety of a building when subjected to prescribed condition of heat resistance.The fire resistance test of structures shall be done in accordance with IS 3809-1979 Fire Resistance Test of structure;\n(42) \"fire resisting building\" means a building in which material, which has appropriate degree of fire resistance, is used;\n(43) \"fire separation\" means the distance in meters measured from any other building on the site of or another site, or from the opposite side of a street or other public space to the building;\n(44) \"fire service inlet\" means a connection provided at the base of a building for pumping up water through in built fire fitting arrangements by fire service pumps in accordance with the recommendation of the District Fire Officer;\n(45) \"fire tower\" means an enclosed staircase that can only be approached from the various floors through landings or lobbies separated from both the floor area and the staircase by fire resistant doors;\n(46) \"fire hazard industries\" means,-\n(i) \"Low Fire Hazard Industries\" includes Engineering Industries using / processing or assembling non combustible materials i.e. lathe machines, steel works, steel components, etc.\n(ii) \"Moderate Fire Hazard Industries\" includes industries using / processing combustible materials but not flammable liquid etc., plastic industries, rubber, and PVC industries, textile, paper, furniture, flour mills, etc;\n(iii) \"High Fire Hazard Industries\" includes industries using / processing flammable liquids, gases, chemicals, petroleum products, plastic or thermo setting group, etc;\n(47) \"floor\" means the lower surface in a storey on which one normally walks in a building and does not include a mezzanine floor. The floor above it shall be termed as floor - 1, with the next higher floor being termed as floor - 2, and so on upwards;\n(48) \"Floor Area Ratio (FAR)\" means the quotient of the ratio of the combined covered area (plinth area) of all floors, excepting areas specifically exempted under these rules, to the total area of plot, viz.:-\nFloor Area Ratio (FAR) = Tota1 Covered Area of All Floors x 100 Plot Area\n(49) \"footing\" means a foundation unit constructed in brick work, stone masonry or concrete under the base of a wall or column for the purpose of distributing the load over a larger area;\n(50) \"foundation\" means that part of the structure, which is in direct contact with ground and transmits load over it;\n(51) \"front air plane\" means the plane contained between the ground in front of the building and the straight lines drawn downwards and outwards from the line of intersection of the outer surface of any front wall of the building with the roof perpendicular to that line, and at an angle of 63-1/2 degrees to the horizontal. The 63-1/2 degrees angle has a tangent of 2:1 so that if the ground is the level, the air plane reaches the ground at a distance from the exterior wall equal to half the height of the above level of that ground;\n(52) \"form\" means forms appended to these rules;\n(53) \"gallery\" means an intermediate floor or platform projecting from a wall of an auditorium or a hall providing extra floor area, and / additional seating accommodation and includes the structures provided for seating in stadia;\n(54) \"garage private\" means an accessory building designed or used for the storage of motor driven vehicles owned or used by the occupants of the building to which it is necessary;\n(55) \"garage public\" means a building or portion thereof designed other than as a private garage, operated for gain, designed and / or used for repairing, servicing, using, selling or storing or parking motor driven or other vehicles;\n(56) \"grey waste water\" means waste water discharged from the bathrooms, sinks, showers and from washing clothes, and so on;\n(57) \"green building\" means abuilding which uses least possible quantity of water and electrical energy, optimizes energy efficiency, makes use of alternate sources of energy such as sunlight and solar energy, conserve natural resources including rain water harvesting, generate less waste in terms of energy and material and provides healthier spaces for occupants compared to a conventional building;\n(58) \"ground floor\" means storey, which has its floor surface nearest to the ground around the building;\n(59) \"group housing\" means apartments or multi-storeyed housing with more than 4 (four) building blocks in a plot where land is owned jointly and the construction is undertaken by a single agency;\n(60) \"habitable room\" means a room occupied or designed for occupancy for human habitation and incidental uses, but excluding kitchen, bath room, water closet compartment, laundry, serving and storing, pantry, corridor, cellar, attic, store room, pooja room and spaces not frequently used;\n(61) \"hedge\" means number of shrubs of trees (often similar species) planted closely together in the line. A hedge may be pruned to shape or allowed to grow to assume its natural shape;\n(62) \"heritage building\" means any building of one or more premises or any part thereof which requires preservation and conservation for historical, architectural, environmental, cultural or religious purpose includes such portion of the land adjoining such buildings as may be required;\n(63) \"heritage zone\" means the area around such heritage building as delineated by the Authority from time to time for restricting the height of building and use of building;\n(64) \"high rise buildings\" means all buildings 15 meter and above in height shall be considered as high rise buildings as per National Building Code of India,2005. For high-rise building the following additional provisions of means of access to the buildings shall be ensured, -\n(i) the width of main street on which the building abuts shall not be less than 12 meters and 1(one) end of this street shall join another street not less than 12 meters in width;\n(ii) the road shall not terminate in a dead end, except in the case of residential building up to a height of 30 meter;\n(iii) compulsory open space around the high-rise buildings shall not be used as parking;\n(iv) adequate passageway and clearances required for fire fighting vehicles to enter the premises shall be provided at the Main Entrance, the width of such entrance shall not be less than 4.5 meter if an arch or covered gate is constructed, it shall have a clear head room of not less than 5 meter;\n(65) \"illuminated exit signs\" means a device for indicating the means of escape during normal circumstances and power failure;\n(66) \"jali\" means a grill or screen made of metal, brick, ferro-cement, wood or any other material which is placed in front of a window, door or any opening or piece of machinery in order to protect it;\n(67) \"jhamp (awnings)\" means a downward, vertical or sloping projection hanging below any horizontal projection like balcony, canopy, verandah, passage etc, to provide protection from direct sun and rain;\n(68) \"jhot (land reserved for drain)\" means a strip of land permanently left open for drainage purposes. It is not to be used as an access way or a street and is not to be included as a part of setbacks;\n(69) \"katra or chawl\" means a building so constructed as to be suitable for living in separate tenements each consisting a single room, or of two, but not of more than two rooms and with common sanitary arrangements;\n(70) \"ledge\" means a shelf-like projection supported in any manner whatsoever except by vertical supports within a room itself but without a projection of more than half a meter;\n(71) \"Licensed Architect/Engineer/Supervisor/Plumber\" means a qualified Architect/Supervisor, Engineer, Plumber who has been enrolled/licensed by the Authority;\n(72) \"lift\" means a mechanically guided car, platform for transport or persons and materials between two or more levels in a vertical or substantially vertical direction;\n(73) \"lobby\" means a covered space in which all the adjoining rooms open;\n(74) \"loft\" means an intermediate floor between two floors or a residual space in a pitched roof above normal level constructed for storage with maximum clear height of 1.5 meters;\n(75) \"light plane\" means the plane lying between the line of intersection of the floor of any room in a building with the outer surface or an exterior wall of the building and the straight lines drawn upwards and outwards from those lines drawn upward and outwards from lines perpendicular thereto an at angle of 63 ½ degrees to the horizontal;\n(76) \"masonry\" means an assemblage of masonry units properly bound together by mortar;\n(77) \"masonry unit\" means an unit whose net cross-sectional area in every plane parallel to the bearing surface is 75% or more of its gross cross-sectional area measured in the same plane. It may be either of clay, brick, stone, concrete, sand lime brick or any other construction material;\n(78) \"Master Plan\" means a Master Plan as defined in the Assam Town and Country Planning Act,1959 (Assam Act 2 of 1960);\n(79) \"mezzanine floor\" means an intermediate floor between two floors of any storey forming an integral part of floor below;\n(80) \"mumti or stair cover\" means a structure with a covering roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not used for human habitation;\n(81) \"means of escape\" means an escape route provided in a building for safe evacuation of occupants;\n(82) \"miniature circuit breaker(MCB)\" means devices for tripping of electrical circuits in event of any fault in the circuit/installation;\n(83) \"natural drain\" means a drain which is a natural path that transmits natural stream water or storm water runoff from a point of higher elevation to a point of lower elevation;\n(84) \"non combustible material\" means a material which is not liable to burn or add heat to a fire when tested for combustibility in accordance with the latest code of Bureau of Indian Standards Method of Test for combustibility of building materials;\n(85) \"open space\" means an area forming an integral part of the plot left open to the sky for the purpose of these rules;\n(86) \"owner\" means the person, when used in reference to any premises who receives the rent of the said premises or would be legally entitled to do so if the premises were let out. It also includes,-\n(a) an agent or trustee who is legally authorized to receive such rent on behalf of the owner;\n(b) a receiver, executor or administrator or a manager appointed by any court of competent jurisdiction to have the charges of or to exercise the rights of owner of the said premises;\n(c) a person having legal title ship over the premises / plot of land;\n(87) \"parapet\" means a low wall or railing built along the edge of a roof or a floor;\n(88) \"parking space\" means an area enclosed or unenclosed, sufficient in size to store an automobile or any other conveyance together with a drive way connecting the parking space with a street, or alley and permitting ingress or egress of all such conveyances;\n(89) \"partition\" means an interior divider of storey or part storey in height;\n(90) \"permanent open air space\" means an air space permanently open ,-\n(a) if it is a street;\n(b) if it is free from encroachment, is protected by any law or contract ensuring that the ground below it is either a street or is permanently and irrevocably appropriated as an open space;\n(91) \"permission or permit\" means a valid permission or authorization in writing by the competent Authority to carryout development or a work regulated by these rules;\n(92) \"part wall\" means and includes,-\n(i) a wall forming part of a building and being used or constructed to be used in any part of the height or length of such wall for separation of adjoining building belonging to different owners or constructed or adopted to be occupied by different persons; or\n(ii) a wall forming part of a building and standing in any part of the length of such wall, to a greater extent than the projection of the footing on one side or ground of different owners;\n(93) \"plinth\" means the portion of a structure between the surface of the surrounding ground and surface of the floor immediately above the ground;\n(94) \"plinth area\" means the built up covered area measured at the floor level of the basement or of any storey;\n(95) \"plot\" means a parcel or piece of land enclosed by definite boundaries;\n(96) \"porch\" means a covered surface supported on pillars or otherwise for the purpose of a pedestrian or vehicular approach to a building;\n(97) \"road/street\" means any highway, street, lane, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether public or private,whether a thoroughfare or not,over which the public have a right of passage or access or have passed and have access uninterruptedly for specified period, whether existing or proposed in any scheme and includes all bends, channels, ditches, storm water drains, culverts sidewalks, traffic islands, roadside trees and hedges, retaining walls, fences, barriers and railing within the street lines;\n(98) \"retention activity\" means an activity or use which is allowed to continue, notwithstanding its non-conforming nature in relation to the use permitted in the adjoining or surrounding area;\n(99) \"road/street level or grade\" means the officially established elevation or grade of the centerline of street upon which a plot fronts, and if there is no officially established grade, the existing grade of street at its mid-point;\n(100) \"road / street line\" means the line defining the side limits of a road / street;\n(101) \"road width\" means the whole extent of space within the boundaries of a road when applied to a development plan or prescribed road lines by any act of law and measured at right angles to the course or intended course of direction of such road;\n(102) \"row housing\" means a row of houses with only front, rear and interior open spaces;\n(103) \"rear air plane\" means the plane contained between the ground behind the building and the straight line drawn downwards and outwards from the line of intersection of the outer surface of any rear wall of the building with the roof perpendicular to that line and at an angle 63 1/2 degree to the horizontal;\n(104) \"room height\" means the vertical distance measured from the finished floor surface to the finished ceiling;\n(105) \"service road\" means a road/lane provided at the front, rear or side of a plot for service purpose;\n(106) \"set back line\" means a line usually parallel to the plot boundaries or center line of a road and laid down in each case by the Authority or as per recommendations of Master / Zonal Plan, beyond which nothing can be constructed towards the plot boundaries excepting with the permission of the Authority;\n(107) \"settlement\" means a human settlement, whether urban or rural in character. It includes habited villages, towns and the areas notified under the control of the Authority;\n(108) \"site\" means a parcel or piece of land enclosed by definite boundaries;\n(109) \"Schedule\" means the Schedule appended to these rules;\n(110) \"site corner\" means a site at the junction of and fronting on two or more roads or streets;\n(111) \"site depth\" means the horizontal distance between the front and rear side boundaries;\n(112) \"site with double frontage\" means a site having frontage on two streets other than corner plot;\n(113) \"site, interior or tandem\" means a site, access to which is by a passage from a street whether such passage forms part of the site or not;\n(114) \"storey\" means the portion of a building included between the surface of any floor and the surface of the next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it;\n(115) \"spiral staircase\" means a staircase forming continuous winding curve round a central point or axis provided in an open space having tread without risers;\n(116) \"slum housing\" means apartments or multi-storeyed housing specifically constructed for providing residential accommodation to Slum Dwellers in notified slum areas of BSUP/IHSDP schemes under JNNRUM of Government of India, RAY etc;\n(117) \"to abut\" means to be positioned juxtaposed to a road, lane, open space, park, building etc;\n(118) \"to erect\" means to construct a building for the first time or to reconstruct an existing building after demolishing it according to some fresh or revised plan;\n(119) \"to re-erect\" means a construction for a second time or subsequent further times a building or part of a building after demolishing it, on the same plan as has been previously sanctioned;\n(120) \"to make material alterations\" means to make any modification in any existing building by way of addition or alteration, or any other change in the structure which alters specification of the building or structure which shall also include,-\n(a) conversion of a building or any part thereof for human habitation as one dwelling house into more than one dwelling house and vice versa;\n(b) conversion of a building or a part thereof suitable for human habitation into a dwelling house or vice-versa;\n(c) conversion of a dwelling house or a part thereof into a shop, warehouse or factory or vice-versa, and;\n(d) conversion of building used or intended to be used for one purpose such as a shop, warehouse or factory, etc., into one or another purpose.\n(121) \"use\" means the purpose for which the building or a part of building is used or intended to be used and the term mixed use shall mean and include a building which is used for more than one use in different position of the building;\n(i) Residential Buildings : These shall include any building, in which sleeping accommodation is provided for normal residential purposes with or without cooking or dining or both facilities, including one or two or multi-family dwellings, lodging dormitories, apartment houses, flats and hostels.\n(ii) Institutional Buildings: Institutional buildings ordinarily provide sleeping accommodation for the occupants and specialized non-commercial training centers. It includes hospital, sanatoria, custodial institutions and penal institutions like jails, prisons, mental hospitals and reformatories. These shall include any building used for school, college or day care purposes involving assembly for instruction, education or recreation where it is a part of education and other public and semi-public buildings.\n(iii) Assembly Buildings : These shall include any building or part of a building where groups of people congregate or gather for amusement, recreation, special, patriotic, civil travel and similar purposes, for example, marriage hall, theatre, motion picture houses, assembly halls, auditoria, libraries, exhibition halls, museums, skating rinks, gymnasium, restaurants, dance halls, clubs, passenger stations and terminals of air, surface and other public transportations services and stadia. These shall include any building used for religious purposes like prayers, puja, worship, religious or spiritual congregations, discourses, rituals and functions.\n(iv) Commercial Buildings: These shall include any building or part of a building which is used as shop, store, market for display and sale of merchandise either wholesale or retail, office storage or service facilities incidental to the sale of merchandise and located in the same building shall be included under this group. These shall include any building or part of a building which is used for transaction of business and / or the of a building which is used for transaction of business and / or the keeping of accounts and records therefore including offices, banks, professional establishment etc. if their principal function is transaction of business or keeping of books and records.\n(v) Industrial Buildings: These shall include any building or part of a building or structure, in which products or materials of all kinds and properties are fabricated, assembled or processed like assembly plants, laboratories, power plants, smoke houses, refineries, gas plants, mills, dairies, factories etc.\n(vi) Storage Buildings: These shall include any building or part of building is primarily for the storage or sheltering of goods, wires, merchandise, like warehouses, cold storage, freight depots, transit sheds, store houses, garages, hangers, truck terminus, grain elevators, barns and stables.\n(vii) Multi-storeyed Building or High Rise Building: A building above 4 stories, and/or a building exceeding 15 meters or more in height above the average level of front road.\n(viii) Multi Level Car Parking Building: A building partly below ground level having two or more basements or above ground level, primarily to be used for parking of cars, scooters or any other type of light motorized vehicle.\n(ix) Office Building (Premises): includes a building or premises or part thereof whose sole use is for an office or for official purposes or clerical work. Official purposes include the purpose of administration, clerical works include writing, book-keeping, sorting of papers, typing, duplicating papers etc.\n(x) Hazardous Buildings: These shall include any building or part of a building which is used for the storage, handling, manufacture or processing of highly combustible or explosive materials or products which may produce poisonous fumes or explosions for storage, handling, manufacturing or processing which involve highly corrosive toxic or noxious alkalis, acids or other liquid or chemicals producing flame, fumes and explosive poisonous, irritant or corrosive gases, and for the storage, handling or processing of any material producing explosive mixtures or dust for which result in the division of matter into fine particles subject to spontaneous ignition.\n(xi) Special building: includes assembly, industrial, hazardous buildings, buildings used for wholesale establishments, hotels, hostels, centrally air conditioned buildings and which exceed 15 meters in height and have a total built up area exceeding 600 sq. m.\n(xii) Detached Building: Includes a building with walls and roofs independent of any other building and with open spaces on all sides within the same plot.\n(xiii) Semi-detached Building: A building detached on three sides with open space as specified in these rules.\n(xiv) Mixed Land Use Building: A building partly used for non-residential activities and partly for residential purposes.\n(xv) Unsafe Building: Includes a building which is structurally unsafe or insanitary or not provided with adequate means of ingress or egress or constitutes a fire hazard or dangerous to human life or constitutes a hazard to safety, health, public welfare by maintenance, dilapidation, abandonment, all in relation to its existing use;\n(122) \"unauthorized construction\" means the erection or re-erection, addition or alternations which is not approved or sanctioned by the Authority;\n(123) \"underground/overhead tank\" means an underground/overhead water tank, constructed or placed to store water;\n(124) \"ventilation\" means the supply of outside air into a building through window or other openings due to wind outside and convection effects arising from temperature, or vapour pressure differences (or both) between inside and outside of the building.;\n(125) \"water closet\" means a privy with an arrangement for flushing the pan with water. It does not include a bathroom;\n(126) \"window\" means an opening to the outside other than a door, which provides all or part of the required natural light or ventilation or both to an interior space and used as a means of egress/ingress;\n(127) \"Zonal Plan\" means a plan detailing out the proposals of Master Plan and acting as a link between Master Plan and the Layout Plan. It may contain a site plan and land use plan with approximate location and extent of land uses such as public and semi public buildings/works, utilities, roads, housing, recreation, industry, business, markets, schools, hospitals, open spaces etc. It may also specify standards of population density and various components of development of the zone.\n(128) Words and expressions used in these rules and not defined, but defined in the Acts shall have the meanings respectively assigned to them in the Acts.\nChapter II\nProcedure for Obtaining Building Permit",
"footnote": "",
"is_definition": true,
"sort_order": 1
},
{
"number": "3",
"title": "3. Notice.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "4",
"title": "4. Information accompanying application.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "5",
"title": "5. Size of Drawing Sheets and Colour of Plans.",
"chapter": null,
"content": "Table 1: Colour Notation for Plans\nTable 1: Colour Notation for Plans\nSn\nSn\nType\nType\nColour\nColour\n1\nProposed work including services\nRed\n2\nExisting construction proposed to be demolished\nYellow\n3\nExisting structure to be retained\nBlue\n4\nWork in progress duly sanctioned\nGreen\n5\nOpen Space\nNot to be coloured",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "6",
"title": "6. Plans to be submitted for building application.",
"chapter": null,
"content": "(i) the boundaries of the site and any contiguous land belonging to the owner thereof;\n(ii) the position of the site in relation to neighbouring street;\n(iii)the names of the streets on which the building is proposed to be situated, if any;\n(iv) all existing buildings standing on, over or under the site;\n(v) the position of the building and of all other buildings;\n(vi) all adjacent streets / buildings and premises contiguous to the site, structures notified under the Ancient Monument and Archeological Sites and Remains (Amendment and Validation) Act,2010 (Central Act 10 of 2010) and military stations, if any;\n(vii) the means of access from the street to the building, and to all other building;\n(viii) space to be left about the building to secure a free circulation of air, admission of light and access;\n(ix) the width of the street, if any, in front, at the sides or rear of building;\n(x) the direction of north point relative to the plan of the buildings;\n(xi) any existing physical features such as well, drains, trees, over head electric supply lines etc.;\n(xii) the ground area of the whole property and the breakup of covered area on each floor with the calculation for percentage covered in each floor in terms of the total area of the plot as required under the Rules governing the coverage of the area;\n(xiii) parking plans indicating the parking spaces wherever required;\n(xiv) such other particulars as may be prescribed by the Authority; and\n(xv) building number or plot number of the property on which the building is intended to be erected.",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "7",
"title": "7. Layout Planin-case of Land Sub-division.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "8",
"title": "8. Landscape Plan.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "9",
"title": "9. Building Plan.",
"chapter": null,
"content": "(i) the floor plans of all floors together with the covered area clearly indicating the size and spacing of all frame members and sizes of rooms and the position and width of staircases, ramps and other exit ways, lift ways, lift machine room and lift pit details;\n(ii) show the use or occupancy of all parts of the building;\n(iii)show exact location of essential services, for example water closet, sink, bath, etc;\n(iv) include sectional drawing showing clearly the sizes of the footings, thickness of basement wall, wall construction, size and spacing of framing members, floor slabs and roof slabs with their materials; The section shall indicate the heights of building and rooms and also the heights of the parapet and drainage and the slope of the roof; At least one section shall be taken through the staircase, kitchen and toilet, bath and water closet;\n(v) show the elevations from north, south, east and west directions;\n(vi) indicate details of service privy, if any;\n(vii) the dimensions of the projected portions beyond the permissible building line;\n(viii) the terrace plan indicating the drainage and the slope of the roof;\n(ix) the indications of the north point relative to the plan;\n(x) the details of parking spaces provided;\n(xi) the indication of all doors, windows and the other openings including ventilators with sizes in proper schedule; and\n(xii) such other particulars as may be required to explain the proposal clearly and as prescribed by the Authority;",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "10",
"title": "10. Building Plan for Multi-storeyed Buildings / Special Buildings.",
"chapter": null,
"content": "(i) access to fire appliances / vehicles with details of vehicular turning circle / and clear motorable access way around the building;\n(ii) size (width) of main and alternate staircase along with balcony approach, corridor, ventilated lobby approach;\n(iii)location and details of lift enclosures;\n(iv) location and size of fire lift;\n(v) smoke stop lobby / door where provided;\n(vi) refuse chutes, refuse chamber, services duct, etc;\n(vii) vehicular parking spaces;\n(viii) refuge area, if any;\n(ix) details of building services - air conditioning system with position of dampers, mechanical ventilation system, electrical services, boilers, gas pipes etc;\n(x) details of exits including provision of ramps, etc. for hospitals and special risks;\n(xi) location of generator, transformer and switchgear room;\n(xii) smoke exhaust system if any;\n(xiii) details of fire alarm system network;\n(xiv) location of centralized control, connecting all fire alarm systems, built-in fire protection arrangements and public address systems, etc;\n(xv) location and dimension of static water storage tank and pump room;\n(xvi) location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, drenchers, CO2 installations etc;\n(xvii) location and details of first aid fire fighting equipment / installation;\n(xviii) the proper signs / symbols and abbreviation of all fire fighting systems shall be shown as per the relevant BIS codes;\n(xix) solar energy capture plan as prescribed in Schedule IV; and\n(xx) indemnity bond as prescribed in Schedule VII.",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "11",
"title": "11. Services Plan and Water Supply provisions.",
"chapter": null,
"content": "(i) separate conveying system to be provided for sewerage and sullage to facilitate reuse of sullage water for gardening and washing purposes. This may require suitable storage facilities that are to be indicated on the building plans;\n(ii) for recharging ground water, rainwater-harvesting provisions are to be provided within the plot, which are to be indicated on the building plans;\n(iii)general specification of the proposed construction giving type and grade of material to be used, duly signed by the Architect/Engineer/Supervisor may be shown, accompanying the notice, as the case may be;\n(iv) a certificate of supervision and execution of drainage/sanitary works by the Architect/Engineer/ Supervisor, as the case may be, shall further accompany the notice.",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "12",
"title": "12. Signing of Plans.",
"chapter": null,
"content": "(i) Architect holding a valid registration with the Council of Architecture for Layout Plans of plots measuring more than 1 ha and below 10 ha;\n(ii) Town Planner holding valid registration with the Institute of Town Planners, India for plots measuring 10 ha and above.",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "13",
"title": "13. Notice for alteration.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "14",
"title": "14. Repairs.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "15",
"title": "15. Deviation during construction.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "16",
"title": "16. Withdrawal of notice.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "17",
"title": "17. Inspection on submission of application.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "18",
"title": "18. Fees for permission.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "19",
"title": "19. Grant of Permit or Refusal.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "20",
"title": "20. Duration of sanction.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "21",
"title": "21. Revocation of Permit.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "22",
"title": "22. Notice for Inspection on work commencement.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 21
},
{
"number": "23",
"title": "23. Completion Certificate.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 22
},
{
"number": "24",
"title": "24. Occupancy Certificate.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 23
},
{
"number": "25",
"title": "25. Part Occupancy Certificate.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 24
},
{
"number": "26",
"title": "26. Existing Buildings.",
"chapter": null,
"content": "(1) If a building or a room in a building be in the opinion of the concerned urban local body (the Board of the body at a meeting) is unfit for human habitation then the provisions of section 181 of the Assam Municipal Act,1956shall be followed.\n(2) The Board before taking action under sub rule (1) shall obtain and consider report of the Structural Engineer regarding fitness of such building.",
"footnote": "",
"is_definition": false,
"sort_order": 25
},
{
"number": "27",
"title": "27. Modification of plans.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 26
},
{
"number": "28",
"title": "28. Correspondence.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
{
"number": "29",
"title": "29. Qualification and competence.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 28
},
{
"number": "30",
"title": "30. Debarring or black-listing professionals indulged in professional misconduct.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 29
},
{
"number": "31",
"title": "31. Provision to ensure compliance of sanctioned plan, etc.",
"chapter": null,
"content": "(i) in G+3 building and above, the owner is required to hand over an area of 10% of the total built-up area to the sanctioning authority by way of a notarized affidavit. The 10% area handed over to the Authority shall be released on submission of Completion Certificate by owner alongwith the Occupancy Certificate issued by authority;\n(ii) for buildings upto G+2, two times the property tax shall be levied if occupancy certificate is not obtained by the owner for Authority.",
"footnote": "",
"is_definition": false,
"sort_order": 30
},
{
"number": "32",
"title": "32. Un-authorised Construction.",
"chapter": null,
"content": "(i) It shall be lawful for the Authority to demolish the construction carried out in excess of the approval plan or not in conformity with the provisions of these rules. The Authority shall make an order of such demolition\n(ii) It shall be lawful for the Authority to proceed for sealing of the building that has been constructed without a sanction plan or the construction undertaken is in deviation of the approved plan. The Authority shall make an order of such sealing.",
"footnote": "",
"is_definition": false,
"sort_order": 31
},
{
"number": "33",
"title": "33. Pre-code Building Permit.",
"chapter": null,
"content": "Chapter III\nStandards for Building other than Huts",
"footnote": "",
"is_definition": false,
"sort_order": 32
},
{
"number": "34",
"title": "34. Foundation and Structural design.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 33
},
{
"number": "35",
"title": "35. Site Specification.",
"chapter": null,
"content": "(i) The Authority considers that site is insanitary or that it is dangerous to construct a building on it;\n(ii) There is no approach road with width of at least 3.60 m, excluding 90 cm x 2 = 1.80 m width for drains on both sides of the approach road;\n(iii)If any plot is situated in already developed areas and the means of access is less than the minimum prescribed width, the Authority may consider the proposal with 50% coverage and 100 FAR;\n(iv) (a) No building shall be constructed on any sites or on any part of which there is deposited refuse excrete or other offensive matter to which the health Authority objects until such refuse has been removed there-from and the site has been prepared or left in a manner suitable for building purpose to the satisfaction of the Authority:-\n(b) No building shall be erected on a site liable to flood or on a slope forming an angle of more than 45 degree with the horizontal or on soil unsuitable for percolation unless it is proved by the owner to the satisfaction of the Authority that erection of such a building shall not be dangerous or injurious to health or involve danger from flooding or erosion or cause undue expenditure of public fund in the provision of roads, sewage, sanitation, water supply or other public services.\n(c) No building shall be erected on a site which comprises or includes a pit, quarry or other excavations or any part thereof unless such site has been prepared or left in a manner and condition suitable for building purposes to the satisfaction of the Authority.\n(d) Whenever the dampness of site or the nature of the soil renders such precaution necessary the ground surface of the site between the walls of any building erected thereon shall be covered with a layer of sound cement concrete not less than 150 mm thick or with asphalt paving on a layer of sound cement concrete not less than 150mm thick or with asphalt paving on a layer of closely packed broken stone hard cake not less than 1 50mm thick or otherwise rendered damp proof to the satisfaction of the Authority.",
"footnote": "",
"is_definition": false,
"sort_order": 34
},
{
"number": "36",
"title": "36. Means of access.",
"chapter": null,
"content": "Table 2: Means of Access to Buildings\nTable 2: Means of Access to Buildings\nMinimum Road Width\nMinimum Road Width\nS.n.\nS.n.\nType of Building\nType of Building\nMinimum Road Width (in m)\nMinimum Road Width (in m)\nDrains (in m)\nDrains (in m)\n1\nResidential\n3.60\n2X0.90\n2\nApartment\nUp to 11.5 m in height\n6.60\n2X 0.90\nAbove 11.5 m in height\n8.00\n2X 0.90\n3\nMulti-storeyed Commercial/Residential\nAbove 11.5 m height\n9.00\n2X 0.90\n4\nCommercial (mixed use) up to 11.5m height\n6.60\n2X 1.00\n5\nInstitutional\n9.00\n2X 1.00\n6\nHospital /Nursing Home\n9.00\n2X 1.00\n7\nHall for social gathering/Assembly Hall\n9.00\n2X 1.00\n8\nIndustrial/Warehouse etc. and similar use\n9.00\n2X 1.00",
"footnote": "",
"is_definition": false,
"sort_order": 35
},
{
"number": "37",
"title": "37. Plinth.",
"chapter": null,
"content": "(i) less than 0.5m and more than 0.75m above the ground level of the plot;\n(ii) the ground level should not be raised more than 0.5m from the finished surface of the nearest street level to be fixed permanently by concerned Authority, like the Municipal Board, Town Committee, Development Authority, etc., as the case may be, in the plain areas. As for the hilly area of the city, the local condition shall be considered. However, the proposal is to be framed with minimum of hill cutting, without effecting adjoining plots;\n(iii) bath rooms, water closets, cowsheds, garages, courtyards and godowns may be constructed at 0.2 m plinth height from the ground level (either existing or formed by filling or cutting);\n(iv) 0.3 m higher than the highest recorded flood level, which is to be certified by the local authority.",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
{
"number": "38",
"title": "38. Floor.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 37
},
{
"number": "39",
"title": "39. Brick Wall.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
{
"number": "40",
"title": "40. Wattle created wall.",
"chapter": null,
"content": "(i) the maximum area of one framed panel of the wall should not exceed 2 sq.m in the case of line plaster and 3 sq. m in the case of cement plaster;\n(ii) the thickness of such wall should not be less than 15mm;\n(iii) the detail construction of such wall should be according to the rules as laid down in Assam General specification published by PWD.",
"footnote": "",
"is_definition": false,
"sort_order": 39
},
{
"number": "41",
"title": "41. Boundary wall/Compound wall.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
{
"number": "42",
"title": "42. Number of rooms.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 41
},
{
"number": "43",
"title": "43. Minimum sizes of rooms.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 42
},
{
"number": "44",
"title": "44. Slope of pitched roofs.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 43
},
{
"number": "45",
"title": "45. Latrines and Lavatories (in general).",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 44
},
{
"number": "46",
"title": "46. Served Latrine.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
{
"number": "47",
"title": "47. Septic tanks.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 46
},
{
"number": "48",
"title": "48. Location of Septic Tank's Sub-surface Absorption System.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 47
},
{
"number": "49",
"title": "49. Requirements of Septic tank.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 48
},
{
"number": "50",
"title": "50. Bathrooms.",
"chapter": null,
"content": "(i) a building or part thereof designed or used for occupation by separate families on containing separate apartment shall have one bathroom for each family or apartment;\n(ii) a building designed or used for human habitation other than in separate apartments shall be provided with one bathroom or shower room to every closet.\n(i) if the bath room is attached to any dwelling room of the house the wall in between shall be solid masonry of 1.0m high from the floor of the bath room;\n(ii) there shall be a floor area of not less than 2 sq.m of which the smallest side should not be less than 1.2m.;\n(iii) it shall have a window of a superficial area of not less than 0.2 sq.m and it shall open upon minimum wide open space or open to an open verandah of not more than 1.8m wide opening on to such open space, or to any duct, the sizes of which should be as prescribed in clause light and ventilation of rooms;\n(iv) it shall have an impermeable floor made of smooth, hard material having a suitable fall of 1 in 30 for the drainage of the water;\n(v) the height of the bathroom should not be less than 2.4m.;\n(vi) in dwelling containing not more than two bedrooms access from the bedrooms to an only bathroom shall be had without passing through another habitable room.\n(vii) in dwelling containing 3 or more bedrooms access to the bathrooms from 2 of the bedrooms shall be had without passing through another habitable room.",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
{
"number": "51",
"title": "51. Kitchen.",
"chapter": null,
"content": "(a) A superficial floor area of not less than 3.35sq.m of which the smallest side should not be less than 1.5m;\n(b) Height of kitchen roof should not be less than 3.0m;\n(c) A window of not less than 0.5 sq.m superficial area opening directly into the external air and to a duct, the size of which should be as prescribed in rule 53.",
"footnote": "",
"is_definition": false,
"sort_order": 50
},
{
"number": "52",
"title": "52. Open space for ventilation.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 51
},
{
"number": "53",
"title": "53. Ventilation of rooms.",
"chapter": null,
"content": "Table 3: Specification as per use\nTable 3: Specification as per use\nUse\nUse\nHeight of building\nHeight of building\nMin area of shaft\nMin area of shaft\nMin width of shaft\nMin width of shaft\nWater Closet, bath and store\n(a) upto 18m\n(b) above 18m\n3.00sq.m\n6.25 sq.m\n2.0 m\n2.5 m\nKitchen & dining\n(a) upto 18 m\n(b) above 18 m\n6.25 sq. m\n9.00 sq. m\n2.5 m\n3.0 m",
"footnote": "",
"is_definition": false,
"sort_order": 52
},
{
"number": "54",
"title": "54. Height Regulation.",
"chapter": null,
"content": "(i) there shall be minimum of 3.0m measured from the surface of the floor to the next floor above it;\n(ii) there shall be maximum of 3.0m measured from the surface of the floor to the lowest point of the ceiling, the joints or beams etc, provided that for the commercial streets, the height of the ground floor shall not be less than 4.8m.;\n(iii) maximum height of the building and additional requirement shall not exceed 3 storey or a height of 11.5m without the following additional provisions for open space all around the building except in cases where otherwise specified;\n(iv) the side and rear setback shall be increased by 0.3m for every 1.5m additional height of the building in addition to the setback already prescribed in this rule subject to maximum of 4.5m side setback and 6.0m rear setback;\n(v) building height shall not exceed 1.5 times of the width of the road plus front open space;\n(vi) residential building should not be cut by 45 degree angle line drawn from the opposite edge of the road. However, building up to two storeys is exempted of it;\n(vii) for the purpose of height calculation width of the road shall be taken as existing road width.\n(a) lift machine room, staircase, parapet height shall not be included in the height of the building;\n(b) for a building constructed on stilt with provisions of ground level parking floor or semi-basement parking floor, the height of the building shall be calculated by omitting the height of the parking floor up to a maximum of 2.7 m for the purpose of building height subject to provision of exclusive parking in the ground floor with special earthquake resistance measure. But for additional set back calculation, height of building shall be calculated from actual ground level;\n(c) the following appurtenant structure shall not be included in the height of the building:-\n- roof tanks and their support not exceeding 1.5m in height\n- ventilating, air-conditioning, lift rooms and similar service equipments, stair covered with room upto 3.0 m in height, chimney and architectural features not exceeding 1.5 m in height.\n(viii) building above the height of 15 m shall require necessary clearance from District Fire Service;\n(ix) for a building with a height 12m or above 4 floors including the ground floor, at least one lift shall be made available. For EWS and LIG buildings of 15 m and above, at least 1 lift is to be provided as provided in National Building Code of India;\n(x) maximum height of parking floor shall be 2.7 m measured up to the soffit level;\n(xi) if a building is situated on two or more streets of different widths, the building shall be deemed for the purpose of those rules to face the streets which has the greater width and height will be as per these rules.",
"footnote": "",
"is_definition": false,
"sort_order": 53
},
{
"number": "55",
"title": "55. Corridors and Passage.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 54
},
{
"number": "56",
"title": "56. Post, Post plate, Truss etc .",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 55
},
{
"number": "57",
"title": "57. Water supply.",
"chapter": null,
"content": "(i) public or municipal water if available;\n(ii) a drilled, driven or dug well or tube well\nTable 4: Water Supply as per Occupancy\nTable 4: Water Supply as per Occupancy\nOccupancy\nOccupancy\nBasis\nBasis\nResidential Building\n5 Persons / Tenement\nOther Building\nNo. of persons based on occupant load and area of\n\t\t\t\tfloors given in Schedule I.",
"footnote": "",
"is_definition": false,
"sort_order": 56
},
{
"number": "58",
"title": "58. Standard for RCC wells for drinking water.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 57
},
{
"number": "59",
"title": "59. Basement.",
"chapter": null,
"content": "(a) basement can be constructed up to minimum prescribed setbacks line and beyond prescribed building lines;\n(b) basement shall not be permitted in low lying areas and areas without adequate drainage facilities to ensure drainage from the basement;\n(c) every basement shall be in every part at least 2.4 m in height from the floor to the underside of the roof slab or ceiling;\n(d) adequate ventilation shall be provided for the basement. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning system etc;\n(e) adequate arrangements shall be made such that surface drainage do not enter the basement;\n(f) the walls and floor of the basement shall be watertight and be so designed that the effect of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given;\n(g) the access to the basement shall be separate from the main and alternate staircase providing access and exit from higher floors, where the staircase is continuous in case of building served by more than one staircase the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors; and\n(h) if such ramps are provided in basement parking floor the gradient of it should be minimum 1:5 and the height of 2;4 m is to be maintained at the entrance also.\n(a) storage of household or other goods of ordinary non combustible material;\n(b) strong rooms, banks cellars etc;\n(c) air conditioning equipment and other machines used for services and utilities of building subject to satisfaction of the Authority;\n(d) parking spaces and\n(e) air conditioned shopping which will then be counted in FAR.",
"footnote": "",
"is_definition": false,
"sort_order": 58
},
{
"number": "60",
"title": "60. Numbering of houses.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 59
},
{
"number": "61",
"title": "61. Barrier-free building.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 60
},
{
"number": "62",
"title": "62. Electricity and Telephone Connection.",
"chapter": null,
"content": "Table 5: Specifications for Electricity lines\nTable 5: Specifications for Electricity lines\nVertical distance in meters from the building\nHorizontal distance in meters from the building\nLow and medium voltage lines and service lines\n2.5\n1.2\nHigh Voltage lines up to and including 33 KV\n3.7\n2.0\nExtra High Voltage lines beyond 33 KV\n4.6\n4.5\n(Plus 0.3 meters for every additional 33 KV or part\n\t\t\t\tthereof)\n(Plus 0.3 meters for every additional 33 KV or part\n\t\t\t\tthereof)",
"footnote": "",
"is_definition": false,
"sort_order": 61
},
{
"number": "63",
"title": "63. Staircases.",
"chapter": null,
"content": "Table 6: Specifications of Staircases\nTable 6: Specifications of Staircases\nTypes\nTypes\nMaximum rise\nMaximum rise\nMinimum tread of obstruction\nMinimum tread of obstruction\nDomestic buildings\n175 mm\n225 mm\nPublic buildings\n150 mm\n275 mm\nHospital & Auditorium\n150 mm\n300 mm",
"footnote": "",
"is_definition": false,
"sort_order": 62
},
{
"number": "64",
"title": "64. Layout and open space.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
{
"number": "65",
"title": "65. Parking space.",
"chapter": null,
"content": "Table 7: Parking Specifications\nTable 7: Parking Specifications\nSl No .\nType of Use\nOne Parking space shall be provided for every\nCar\nScooter\n1\nResidential building\nFor every dwelling unit 60 sq.m\nEvery dwelling unit below 60 sq.mt but above40\n\t\t\t\tsq.m.\n2\nTheatres, Cinemas, Auditorium\nAccommodation of 15 seats or more.\nAccommodation upto10 seats.\n3\nRetail business\n50 sq.mor fraction thereof\n20 sq.m of sales area\n4\nOffice building\n100 sq.m of the floor area or fraction thereof\n20 sq.m of floor area of the Office\n5\nHospital\n5 beds (private), 10 beds (public)\nAccommodation for 5 beds\n6\nHotel\n3 guest rooms\n7\nRestaurants\n10 seats of accommodations\n6 seats of accommodations\n8\nIndustrial building\n20 employees in the industry\n15 employees in the industry\n9\nWhole sale and Warehouses\n60 sq. m. floor area and fraction thereof for car\n\t\t\t\tand scooter\n10\nEducational\n50 sq.m. area or fraction thereof of the\n\t\t\t\tadministrative office area and public service area\n11\nMarriage Hall/ Community Hall\n50 sq.m. plot area\n12\nStadium and exhibition centre\n30 seats\n(b) for calculation of scooter parking space, one car parking space shall be equivalent to 6 scooter parking;\n(c) 2.5 car parking space shall be equivalent to one parking space of heavy vehicle in Industrial and Whole-sale, Warehouse buildings.\n(a) in providing the parking, care has to be taken that 50% of the open space is left for landscaping and not counted for in the parking calculations;\n(b) at least 25% of the open space reserved as organized open space which should be clearly shown in the service plan.\nArea\nArea\nCar Space (in sq.m)\nCar Space (in sq.m)\nBasement parking\n30\nStilt\n25\nOpen Parking\n20\nBuilding type\nBuilding type\nParking space\nParking space\nMulti-storeyed Apartment\n1 car/4 dwelling unit\nShopping/ Office Complex\n1 car/ 100 sq.m of area\n1 two-wheeler/ 50 sq.m of area\nNursing home\n1 car/5 cabins of single accommodation\nChapter IV\nBuilding Specifications as Per Use",
"footnote": "",
"is_definition": false,
"sort_order": 64
},
{
"number": "66",
"title": "66. Regulation for Residential use.",
"chapter": null,
"content": "Table 8: Minimum Plot Size for Residential Use\nTable 8: Minimum Plot Size for Residential Use\nDensity\nDensity\nPlot Size\nPlot Size\nHigh\n15 lessa, i.e, 200 sq. m\nMedium\n01 katha,i.e., 268 sq.m\nLow\n01 katha10lessa, i.e., 402 sq.m\nTable 9: Density wise Plot Size\nTable 9: Density wise Plot Size\nHigh Density\nMinimum Plot size\n10 lessa\nFAR.\n100\nCoverage\n50%\nMedium Density\nMinimum Plot size\n15 lessa\nFAR.\n125\nCoverage\n50% for RCC\n55% for Assam type\nTable 10: Minimum Width of the Plot for Residential Use\nTable 10: Minimum Width of the Plot for Residential Use\nSize of the Plot\nSize of the Plot\nWidth of the Plot (in metre)\nWidth of the Plot (in metre)\nUpto 15 Lessa i.e. 200 sq. m\n6\n15 Lessa to 1 Katha 10Lessa, i.e., 400 sq. m\n10.0\n1 Katha 10 Lessa to 2 Katha 10Lessa , i.e., 600\n\t\t\t\tsq. m\n11.5\nMore than 2 Katha 10Lessa, i.e., more than 600\n\t\t\t\tsq. m\n12.0\n(i) Front Setback. - Every building fronting a street shall have a front space from the prescribed street line forming an integral part of the site as below. In case of building abutting two or more streets both the streets shall be considered for determining front setback building.\nFront Setback.\nWidth of street fronting the plot(in metre)\nMinimum front open space (in metre)\nBelow height of 11.5 m\nHeight of 11.5 m and above\nUpto 6.6\n3.0\n3.0\nUpto 15\n3.0\n4.5\nAbove 15\n3.0\n6.0\n(ii) Side Setback :\n(ii) Side Setback\n(a) for high density zones side setback shall be 1.5 m;\n(b) for medium density zones setbacks shall be 1.5 m; and\n(c) for low density zone side setback shall be 1.8 m.\n(iii) Rear setback for all density zoneshall be 3.0 m\n(iii) Rear setback\nTable 11: Set-back specifications for Multi-storeyed Apartments\nTable 11: Set-back specifications for Multi-storeyed Apartments\nType\nType\nMinimum plot size\nMinimum plot size\nMinimum front setback\nMinimum front setback\nMinimum rear setback\nMinimum rear setback\nMinimum side setback\nMinimum side setback\nApartment up to 11.5 m.\n3 K\n4.5 m.\n4.5 m.\n2.4 m.\n(a) a plot abutting a street with a width of above 15 m, the minimum front setback shall be calculated according to the width of the abutting street;\n(b) the side and rear set backs for buildings above 11.5 m. shall be as per the maximum height of the building and additional requirement as specified in these rules.",
"footnote": "",
"is_definition": false,
"sort_order": 65
},
{
"number": "67",
"title": "67. Regulation for commercial buildings.",
"chapter": null,
"content": "(1) Minimum plot size should be 167.4 sq. m, while minimum width of plot should be 7.5m.\n(2) When setback is up to the height of 11.5 m, -\n(a) minimum front set back of 3.0 m with 1.5 m cantilever in upper floor;\n(b) minimum side set back - a minimum of 1m has to be maintained in each side which can be relaxed to only one side if the adjoining plot owner agrees to have a common wall with his building;\n(c) minimum Rear Setback - Up to plot depth of 18 m, should be 1.5 m. while above plot depth of 18 m, should be 3.0 m with maximum 1.5 m projection on the upper floors;\n(d) if any part of the ground floor or any other upper floor is used for residential purpose or for human habitation, the side set back of the building shall be as per the high density residential zones;\n(e) a plot abutting a street with a width of above 15 m, the front set back shall be calculated according to the width of the abutting street.\n(3) Additional rear and side setback for a building when height is above 11.5 m shall be as follows:-\n(a) if the height is from 11.5 m up to 15 m., the rear setback shall be 3 m and side setback shall be 1.5 m;\n(b) side and rear setback should be increased by 0.3 m for every 1.5 m of additional height of the building in addition to the set backs already prescribed for a building of 15 m height up to a maximum of 1.5 m of additional set backs on both rear and sides.",
"footnote": "",
"is_definition": false,
"sort_order": 66
},
{
"number": "68",
"title": "68. Regulations for buildings to be used for Whole Sale purposes shall be as follows.",
"chapter": null,
"content": "Requirements\nRequirements\nDetails\nDetails\nMinimum plot size\n670 sq. m\nMinimum plot width\n15 m\nMaximum height\na) 15.0m for building of wholesale use\nb) For other building, the height shall be given as per the\n\t\t\t\tmaximum height of the building and additional requirement as\n\t\t\t\tspecified in these rules.\nMinimum front set back\n6.0 m\nMinimum side set back\n1.8 m on one side and the set back on the other\n\t\t\t\tside shall be 3.6 m\nMinimum rear set back\n3.0 m",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
{
"number": "69",
"title": "69. Regulation for Public and Semi Public Use Buildings shall be as follows.",
"chapter": null,
"content": "Requirements\nRequirements\nDetails\nDetails\nMinimum plot size\n400 sq. m\nMinimum front set back\n6.0 m\nMinimum side and rear set back\n3.0 m on one side and the set back on the other side shall be\n\t\t\t\t3.6 m",
"footnote": "",
"is_definition": false,
"sort_order": 68
},
{
"number": "70",
"title": "70. Regulation for Industrial Buildings shall be as follows.",
"chapter": null,
"content": "Requirements\nRequirements\nLight\nLight\nMedium\nMedium\nWidth in m.\nWidth in m.\nArea in sq. m\nArea in sq. m\nWidth in m\nWidth in m\nArea in sq. m\nArea in sq. m\n(1)\nMinimum size of plot\n15.5\n744\n27.5\n18000.00\n(2)\nMinimum set back of all structure / building or the structure\n\t\t\t\tfrom the prescribed street line set\nFront 6.00 Rear 6.00\nSide 3.00\nFront 9.00 Rear 6.00\nSide 6.00\n(3)\nMaximum Height\n15 m",
"footnote": "",
"is_definition": false,
"sort_order": 69
},
{
"number": "71",
"title": "71. Regulation for Special Use Buildings shall be as specified below.",
"chapter": null,
"content": "(1) Nursing Homes/Hospitals\nRequirements\nRequirements\nDetails\nDetails\nMinimum plot size\n1000 sq. m, i.e., 1 Bigha\nMinimum setback\nFront setback\n7.5 m\nRear & side setback\n4.5 m\nMaximum coverage\n45%\nMax. F A R\n150\n(2) Place of Worship (Applicable for new proposals)\nRequirements\nRequirements\nDetails\nDetails\nMinimum plot size\n804 sq. m, i.e., 3 Katha\nMinimum setback\nFront setback\n7.5 m\nRear\n5.0 m\nSide setback\n3.0 m\nMax. FAR\n125\n(3) Cinema Hall and Auditorium\nRequirements\nRequirements\nDetails\nDetails\nMinimum plot size\n1860 sq. m, i.e.,\n\t\t\t\t1Bigha –\n3 Katha – 9Lessa\nMinimum setback\nFront setback\n9.0 m\nRear & side setback\n4.5 m\nMaximum coverage\n40%\nMax. F A R\n125\n(4) Filling Station\n(i) Minimum Plot size - 31 m x 17 m\n(ii) Petrol filling station with servicing bed shall have minimum plot size - 37 m x 31 m\n(5) School Building\nTable 12: Specifications for Educational Institutions\nTable 12: Specifications for Educational Institutions\nMinimum Plot size\nMinimum Plot size\nMaximum Coverage\nMaximum Coverage\nMinimum Front set back\nMinimum Front set back\nMinimum side set back\nMinimum side set back\nMinimum rear setback\nMinimum rear setback\nPre nursery/ Nursery\n535 sq. m, i.e., 02 katha\n50%\n6.0 m\n3.0 m\n3.0 m\nPrimary\n804 sq. m, i.e., 03 katha\n50%\n7.5 m\n3.0 m.\n3.0 m\nHigh School\n2677 sq.m, i.e., 02 bigha\n50%\n7.5 m\n3.0 m\n3.0 m\nCollege\n4015 sq.m, i.e., 03 bigha\n50%\n7.5 m\n3.0 m\n3.0 m\n(i) Organised Parking - 20% of the total plot area;\n(ii) organised recreational open space - 20% of the total plot area; and\n(iii) for Government institutions, regulations adopted by Education Department shall be followed.",
"footnote": "",
"is_definition": false,
"sort_order": 70
},
{
"number": "72",
"title": "72. Regulations for development of U- type building.",
"chapter": null,
"content": "(i) the area so saved is transferred to the central area / space or court yard;\n(ii) the minimum open space on sides and rear except front shall be 1.5 m for building of 11.5m height and 2.4m for building above 11.5m; and\n(iii) minimum plot size for performing such development shall be 500 sq. m.",
"footnote": "",
"is_definition": false,
"sort_order": 71
},
{
"number": "73",
"title": "73. Minimum plot size of builders other than Apartments.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
{
"number": "74",
"title": "74. FAR, Coverage and width of access.",
"chapter": null,
"content": "(1) Residential\n(i) The FAR for different widths of access road shall be :--\nRoad Width (metre)\nRoad Width (metre)\nMaximum FAR\nMaximum FAR\nUp to 4.4\n100\n4.5 to 7.9\n175\n8.0 or more\n200\n(ii) The coverage for different plot sizes shall be :-\nPlot size (sq.m)\nPlot size (sq.m)\nMaximum Coverage (%)\nMaximum Coverage (%)\nUpto 300\n50\n301 to 500\n50\nAbove 500\n45\nNote: In case of plots having access road of 6m or more but with plot sizes smaller than 300sq.m, the FAR could be enhanced up to 200.\n(2) Commercial and Residential-Commercial (Mixed Use)\nPlot size (sq.m)\nPlot size (sq.m)\nMaximum FAR\nMaximum FAR\nMaximum Coverage (%)\nMaximum Coverage (%)\nUpto 300\n200\n50\n301 to 500\n200\n45\nAbove 500\n225\n40\n(3) Others\nType of building\nType of building\nMaximum FAR\nMaximum FAR\nMaximum Coverage (%)\nMaximum Coverage (%)\nMinimum width of access road in metres\nMinimum width of access road in metres\nApartment\n(i) upto 11.5m height\n(ii) above 11.5m height\n175\n200\n40\n40\n6.6\n8\nb) Institutional\n175\n40\n9\nc) Wholesale Commercial\n150\n45\n9\nd) Other public & semi public\n175\n40\n9\ne) Nursing Home\n150\n40\n9\nf) Industrial\n150\n40\n9\ng) place of worship (applicable for new\n\t\t\t\tproposals)\n125\n40\n9\nh) Cinema Hall/ multiplex & Auditorium and\n\t\t\t\tindoor stadium\n125\n40\n9\nNote: For other type of buildings not specifically mentioned above, Authority shall decide considering the similarity of the building with the above use.\n(4) Maximum mezzanine area allowed is 33% of plinth area which shall not be counted in FAR if it has access from only Ground Floor. The height of the mezzanine shall be 2.2m (min) to 2.7m (max).Any built-upin excess of 33% for mezzanine shall be removed by demolition.\n(5) Basement shall not be counted for FAR calculations for following uses :-\n(i) Storage of household goods of non inflammable material;\n(ii) Dark rooms, strong rooms and bank cellars etc;\n(iii) Air conditioning and other machines used for services and utilities of the building;\n(iv) Parking places and garages;\n(v) Stack rooms and libraries;\n(vi) If the basement is used for office or commercial purpose it shall be counted in FAR.;\n(vii) While calculating the FAR following areas are exempted from FAR calculation-lift, staircases and entrance lobby, cupboard space, sentry box, guard room, caretakers room and rain harvesting structures.",
"footnote": "",
"is_definition": false,
"sort_order": 73
},
{
"number": "75",
"title": "75. Additional Area Calculations.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 74
},
{
"number": "76",
"title": "76. Additional Requirement for Multi-storeyed and Special Buildings.",
"chapter": null,
"content": "(i) for outlet from the soak-pit to municipal drain if provided an intermediate treatment chamber shall be installed details of which is to be shown in service plan subject to the approval of Authority and provision made under these rules where ever required;\n(ii) garbage vent;\n(iii) organised open space as specified in these rules;\n(iv) details of building services including,-\n(a) air conditioning system, if any;\n(b) detail of exist including provisions of ramps, etc. for hospital and special risk building;\n(c) location of generator, transformer and switch gear;\n(d) smoke exhauster system and fire alarm, if any;\n(e) location of centralized control of all fire alarm systems, if any;\n(f) location and dimension of static water storage and pump house;\n(g) location of fire protection installation, sprinklers, wetrisers, etc, if any (N.B.- These shall generally be as per specifications of National Building Code 2005)\n(h) size (width) of main and alternate staircase along with balcony approach, corridor and ventilated lobby approach;\n(i) in case of nursing homes and hospitals, detail of incinerator for treatment of hospital waste is to be submitted and clearance from appropriate Authority under the Assam Health Establishment Act 1993 and the rules framed there under shall be required; and\n(j) detail provision made of conservation and harvesting of rain water to be provided as provided in these rules.\n(v) (a) NOC from the District Fire Service shall be required for building above the height of 15.8 m.\n(b) In addition to this NOC, it shall be mandatory to provide all provisions of Part (4) of NBC 2005, for fire and life safety in the building.\n(i) the individual / promoter is required to get their construction checked at mentioned three stages of construction through licensed technical empanelled persons before proceeding with next stage of construction failing which the Authority may revoke the permission;\n(ii) the supervision under this sub-rule shall be done by the concerned empanelled technical persons;\n(iii) the individual Promoter / Developer is required to employ technical personnel of suitable competence for daily supervision of construction work.\n(i) the structural design is required to be done as per IS code of practice by a licensed Structural Engineering consultant and the structural calculations, designs and drawings and specifications are certified by this consultant;\n(ii) the soil testing report on which the design is based is required to be obtained from a licensed Geo technical consultant;\n(iii) for public buildings and apartments, permission for construction shall not be granted unless ,--\n(a) The builder submits detailed calculations of structural design along with copies of structural drawings and specifications certified by the structural engineering consultants;\n(b) Provision is made for appropriate treatment of septic tank effluent, sullage water, garbage and drainage of waste water;\n(c) Authority may go for proof checking of structure design through a structural designs review panel to be setup by the Authority.\n(iv) record of construction progress be intimated to the Authority and stage for recording progress certificate (format to be given by Authority) and checking is given below:--\n(a) plinth in case of basement before casting of basement slab;\n(b) first storey;\n(c) middle storey if in case of multistoried building;\n(d) last storey;\n(v) the progress certificate in Form no. 6, 7, 8 and 9 as the case maybe is to be signed by owner / developers / builders.\n(vi) the progress certificate shall not be necessary in the following cases:-\n- Alteration in building not involving the structural part of the building.\n- Extension of existing residential building on the ground floor upto maximum 15sq m in area.",
"footnote": "",
"is_definition": false,
"sort_order": 75
},
{
"number": "77",
"title": "77. Cinemas, Theatres and Assembly Hall.",
"chapter": null,
"content": "(i) every room in such building as mentioned above shall be lighted and ventilated by doors, ventilators and windows abutting on an interior or exterior open air space which shall not be less than 1/5 of the total floor area; provided if exhaust is installed or if it is air conditioned, the requirement of this rule shall be suitably relaxed by the Authority;\n(ii) gangways and passages must not be more than 6.0 m apart. No seat must be more than 3.0 m from gangway or passage;\n(iii) a gangway or passage must be at least 1.2 m wide and they shall be provided at least one in the center and one of each side;\n(iv) the height of the bottom balcony or the gallery shall not be less than 3.0 m from the floor of the auditorium and depth under the balcony shall not be more than 3 times the clear height. The clear distance between the backs of two successive rows shall not be less than 0.9 m, but for seats with rocking backs it may be 0.8 m;\n(v) the maximum rake of the floor of the auditorium shall not be more than 1 in 20;\n(vi) the maximum width of the balcony steps shall be 0.8 m. Provided that for the front, and rear step, this distance is 0.9 m;\n(vii) the maximum rise of the balcony steps shall be 0.4 m;\n(viii) the maximum height of the roof or ceiling at the highest step of the balcony shall be 3.0 m and at no place the distance between the nosing and lowest projection ray shall be less than 2.4 m;\n(ix) in the case of the cinema the farthest seat shall not be more than 45.0 m anyway from the screen;\n(x) the angle of seating shall not be less than 60 degree and the front row shall not be nearer to the screen than the half of its width;\n(xi) the position and height of the screen be regulated in such a way that the maximum angle of the line of vision from the seat to the top of the screen shall not exceed 35 degrees;\n(xii) no corridor leading to any stair case or exit passage shall be less than 1.5 m in width;\n(xiii) no corridor shall be used for any purpose other that the exit and entrance from the auditorium;\n(xiv) entrance and exit doors shall be provided at a rate of not less than one door of a dimension of 1.5 m in width and 2.4 m in height for every 200 individuals or part thereof;\n(xv) all outdoors for the use of the public be made open outward and in such a manner that when open they shall not obstruct any gangway of passage or stairway or landing;\n(xvi) the access to the auditorium if it is on the upper storey or the galleries shall be provided by not less than two independent stairs of fire proof construction. Such stairs at no place shall be less than 1.5 m clear in width;\n(xvii) no staircase shall have a flight of more than 15 steps or less than 3 steps and width of the landing between such flight shall be the same width of the staircase. The tread of the step shall not be less than 250 mm and rise not more than 150 mm;\n(xviii) no space less than 2.4 m in height shall be allowed under the floor of the auditorium;\n(xix) the cinematograph machine room shall be substantially constructed of fire resisting material or lined with such material.",
"footnote": "",
"is_definition": false,
"sort_order": 76
},
{
"number": "78",
"title": "78. Factories and building of the ware house class.",
"chapter": null,
"content": "Chapter V\nMiscelleneous",
"footnote": "",
"is_definition": false,
"sort_order": 77
},
{
"number": "79",
"title": "79. Special regulations for construction in hilly areas.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 78
},
{
"number": "80",
"title": "80. Environmental aspects and landscaping.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 79
},
{
"number": "81",
"title": "81. Earmarking/reservation of Dwelling Units (DU) for Economically Weaker Section (EWS)/Low Income Group (LIG).",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 80
},
{
"number": "82",
"title": "82. Conservation and Harvesting of Rain water.",
"chapter": null,
"content": "(a) for buildings of height upto Ground + 1 Floors, percolation pits of 30 cm diameter and 3m depth may be made and filled with broken bricks (or pebbles) for 2.85 m and the top covered with perforated Reinforced Concrete Cement (R.C.C.) slab. These percolation pits may be made at intervals of 3m center to center along the plinth boundary. The rain water collected in the open terrace may be collected through a 150 mm PVC (Poly Vinyl Chloride) Pipe laid on the ground and may be allowed to fall in the percolation pits or into a open well through a seepage filter of 60 cm x 60 cm (filter media broken bricks) provided before the open well which shall improve the ground water level. A dwarf wall of 7.5 cm height is built across the entry and exit gates to retain water and allow it to percolate within.\n(b) for special building, Group Developments, Multi-storeyed Buildings, Industries and Institutional Building there shall be a pebble bed of 1 metres width and 1.5 metres depth all round the building and filled with rounded pebbles of 5 centimeter to 7.5 centimeter size. The concrete paving around the building has to be sloped at about 1 in 20 towards the pebble bed, so that rain water from the terrace and side open spaces flow over this pavement and spread into the pebble bed around. Dwarf walls in masonry of 7.5 centimeter, height shall be constructed at the entrance and exit gates to retard rainwater collected into the compound from drawing out to the road.\n(a) in the ground floor, floor level of water closets shall be at least 0.9 metres above the road level to ensure free flow;\n(b) all centrally air conditioned buildings shall have their own wastewater reclamation plant and use reclaimed wastewater for cooling purposes.\n(a) Percolation Pits:- The paved surface around the building shall have percolation pits of 1.2m x 1.2m x 1.2m covering at least 30% of such area. Such pits shall be filled with small pebbles or brick jelly or river sand and covered with perforated concrete slabs;\n(b) Terrace water collection:- The terrace shall be connected to a sump or the well through a filtering tank by PVC pipe. A valve system shall be incorporated to enable the first part of the rain water collected to be discharged out to the soil if it is dirty;\nThe filtering tank measuring 0.6 m to 1.2 m square can be constructed near the sump. A tank can be divided by a perforated slab and one part shall be filled by small pebbles and other by brick jelly. The bottom portion of the tank shall have slope to avoid stagnation of water;\n(c) Open Ground:- Whenever there is open ground a portion of top soil shall be removed and replaced with river sand to allow slow percolation of rain water.\n(d) Piped recharged",
"footnote": "",
"is_definition": false,
"sort_order": 81
},
{
"number": "83",
"title": "83. Re-use of Recycled/Waste Water.",
"chapter": null,
"content": "(a) residential layouts, areas admeasuring 4,000 sq.m. or more;\n(b) group housing/apartment building if the area admeasures 2,000 sq.m. and above or if the consumption of water is 20,000 liters per day or if it is a multi-storied building with 20 or more apartments;\n(c) commercial complexes / institutional / hotel and lodges/industrial buildings etc. if the built-up area is 1,500 sq.m. and more or water consumption is 20,000 liters per day;\n(d) hospitals/nursing homes with 40 or more beds.\n(i) each building shall have a separate downward pipeline to collect waste water from bath and wash basins and the collected waste water shall be treated adequately by organic or mechanical recycling and taken to a Settling tank for onward pumping to the exclusive overhead tank or to a separate collection unit of over head tank for exclusive use of toilet flushing through cisterns. The excess waste water not reused for toilet flushing shall be suitably connected to the rain water recharge structures for ground water recharge.\n(ii) the tank shall be large enough to hold twice the expected daily flow of wastewater plus 40% to allow sludge accumulation and surge loading. One type of settling tank well suited for grey water treatment is a septic tank with aeration facility. (area requirement approx. 8 sq.m per m3 of wastewater)\n(iii) two chemicals, namely, chlorine and iodine may be used to disinfect water. Organic material in grey water may combine with chlorine reduce amount available for disinfection. Filter or settling tank is advisable before disinfection;\n(iv) type of filter required depends on amount of grey water to be filtered and type of contaminants present, viz, simple drain filter, activated charcoal, cellulose or ceramic cartridge, slow sand or multimedia filters etc, could be used based on specific requirement;\n(v) grey water for reuse to be collected in separate unit and provision is made for a separate overhead tank for storage of recycled grey water for use of toilet flushing and gardening/landscaping purpose only;\n(vi) lying of dual pipe lines is necessary, viz., one for carrying potable water and other for carrying grey water duly marked in orange colour and laid separately for the ease of identifying the pipe carrying grey water;\n(vii) if separate point to draw water for gardening, landscaping and washing is provided, it shall be provided with an adequate warning that the water is not fit for drinking.",
"footnote": "",
"is_definition": false,
"sort_order": 82
},
{
"number": "84",
"title": "84. Regular notification/updates.",
"chapter": null,
"content": "(i) National Heritage zones consisting of places of pilgrimage and worship (like Satra, Namghar, Develaya, Mandir, Math, Masjid, Dargah, Gurudwara, Church) and sites of historical and culture importance;\n(ii) areas falling on or abutting natural drainage channels;\n(iii) areas falling on or abutting wetlands;\n(iv) areas earmarked for infrastructure of civic amenities in the Master Plan and Zoning Regulation for the town;\n(v) sites on hills and foothills requiring excavation that is likely to cause soil erosion, landslide or instability of hill slope; and sites below overhanging embedded rocks without proper protection work as specified in these rules;\n(vi) Government land in the hills and in the water bodies like beels;\n(vii) the notified forest land falling within the Master Plan areas;\n(viii) Authority shall judiciously examine all building proposals including multistoried buildings in the vicinity of the above areas before such proposal are cleared / allowed with such condition / modification as Authority may decide from time to time.",
"footnote": "",
"is_definition": false,
"sort_order": 83
},
{
"number": "85",
"title": "85. Additional FAR scheme for widening of roads and improvement of junction.",
"chapter": null,
"content": "(i) in addition to the \"permissible FAR\" to the total extent of the plot area an additional FAR (AFAR) of 100 shall be considered to the extent of the land affected in road widening and junction improvement and surrendered free of cost for constructing / reconstructing building as per land use of Approved Master Plan. However the Authority shall consider commercial use with 50 AFAR even if the land use is earmarked for residential or other uses except Parks and Play Ground and Green Belt use as per Master Plan. The AFAR for commercial use can be utilized in any floor after obtaining permission of the Authority, who shall consider it keeping in view the developments existing on the road/junction, feasibility and smooth flow of traffic. \"Permissible FAR\" is the FAR permissible in that particular plot irrespective of maximum FAR allowed as per these rules.\n(ii) wherever permissible FAR cannot be achieved on plots after road widening and junction improvement with the stipulated setbacks as per these rules and Zoning Regulations the relaxation of set back and coverage can be considered by the Authority.\n(iii) while exercising the above powers the Authority shall finalise a suitable building line (i.e. front setback) for the complete portion of the road taken up for widening or junction taken up for improvement, keeping in view the developments existing on the road/junction, feasibility and smooth flow of traffic and notify the same for the benefit of owners of the sites affected in road widening /junction improvement. No construction shall be allowed in violation of such notified building line. While exercising the above powers the Authority shall ensure public interest and safety and smooth flow of traffic.\n(iv) the relaxation powers referred are applicable to roads notified for widening / junctions notified for improvement under this scheme by the Authority and no isolated case on a particular road or junction shall be considered for this relaxation.\nTable 13:- Specifications of Additional FAR\nTable 13:- Specifications of Additional FAR\nUse Proposed for Additional FAR\nUse Proposed for Additional FAR\nAdditional Floor Area.\nAdditional Floor Area.\nResidential\n100 sq. m\nCommercial\n50 sq. m\n(v) the relaxed FAR shall be issued in the form of a bond to the owners of the affected plot which has to be utilized in a period of five years from the date of issue of this bond;\n(vi) in case of building constructed without any authority beyond the permissible FAR proposal shall be considered for regularization up to the additional FAR allowed as per this scheme.\nChapter VI\nAdditional Provisions for Structural Safety",
"footnote": "",
"is_definition": false,
"sort_order": 84
},
{
"number": "86",
"title": "86. Structural design.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 85
},
{
"number": "87",
"title": "87. For General Structural Safety.",
"chapter": null,
"content": "Part 1:- Section 2 Based Cast-in-situ Piles.\nPart 1:- Section 3 Driven Precast Concrete Piles.\nPart 1:- Section 4 Based precast Concrete Piles.\nPart 2:- Timber Piles.\nPart 3:- Under Reamed Piles.\nPart 4 :- Load Test on Piles.",
"footnote": "",
"is_definition": false,
"sort_order": 86
},
{
"number": "88",
"title": "88. For Cyclone/Wind Storm Protection.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 87
},
{
"number": "89",
"title": "89. For earthquake protection.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 88
},
{
"number": "90",
"title": "90. For protection from Landslide Hazard.",
"chapter": null,
"content": "Note: Whenever an Indian Standard including those referred in the National Building Code is referred, the latest revision of the same shall be followed except specific criteria, if any, mentioned above against that code.",
"footnote": "",
"is_definition": false,
"sort_order": 89
},
{
"number": "91",
"title": "91. Structural Design Basis Report.",
"chapter": null,
"content": "(1) The \"Structural Design Basis Report (SDBR)\"consists of four parts:\nPart-1 - General Information/ Data;\nPart-2 - Load Bearing Masonry Buildings;\nPart-3 - Reinforced Concrete Buildings;\nPart-4 - Steel Buildings.\n(2) Drawings and documents to be submitted for approval of appropriate authorities shall include SDBR as detailed below:-\nPart - 1 Completed;\nPart - 2 (if applicable) - completed;\nPart -3 (if applicable) - undertaking that completed Part 3 shall be submitted before commencement of construction;\nPart- 4 (if applicable) - undertaking that completed Part 4 shall be submitted before commencement of construction.\n(3) SDBR as detailed below shall be submitted to the appropriate authority as soon as design of foundation is completed, but not later than one month prior to commencement of construction.\nPart-1 Completed\nPart-2, Part-3 or Part-4 (if applicable) Completed",
"footnote": "",
"is_definition": false,
"sort_order": 90
},
{
"number": "92",
"title": "92. Seismic Strengthening and Retrofitting.",
"chapter": null,
"content": "Note: (a) for masonry buildings reference is to be made to IS:4326 and IS:13935; and\n(b) for concrete buildings and structures reference to be made to BIS code on evaluation and seismic strengthening for retrofitting of RCC buildings under preparation at present.",
"footnote": "",
"is_definition": false,
"sort_order": 91
},
{
"number": "93",
"title": "93. Review of Structural Design.",
"chapter": null,
"content": "Table 14:- Proof-checking Requirement for Structural Design\nTable 14:- Proof-checking Requirement for Structural Design\nSl.no.\nSl.no.\nType of structure / RCC\nType of structure / RCC\nSubmission from SER or SDBR*\nSubmission from SER or SDBR*\nTo be proof checked/not checked/submitted\nTo be proof checked/not checked/submitted\n01\nLoad Bearing building upto 3 storeys\nSDBR\nNot To Be Checked / Submitted\n02\nBuildings Upto Seven Storeys(R.C.C./ steel framed\n\t\t\t\tstructure)\nSDBR\nTo Be Checked\nPreliminary Design\nNot To Be Checked But Required To Be Submitted\n03\nBuildings More Than Seven Storeys (R.C.C. / Steel\n\t\t\t\tFramed Structure)\nSDBR\nTo Be Checked\nPreliminary Design\nTo Be Checked\nDetailed Structural Design And Structural Drawings\nTo Be Checked\n04\nPublic Buildings\n(A) Load Bearing Buildings / RCC Upto 3 Storeys\nSDBR\nNot To Be Checked\n(B) R.C.C./Steel Structures\nSDBR\nTo Be Checked\nPreliminary Design\nTo Be Checked\nDetailed structural design and structural drawings\nTo be checked\n05\nSpecial Structures\nSDBR\nTo Be Checked\nPreliminary design\nTo be checked\nDetailed structural design-and structural drawings\nTo be checked\n* SDBR - Structural Design Basis Report; SER - Structural Engineer on Record\nNotes: (a) Public building means assembly of large number of people including schools, hospitals, courts etc.; (b)Special structure means large span structures such as stadium, assembly halls, or tall structures such as water tanks, TV tower, chimney, etc.\nNotes:",
"footnote": "",
"is_definition": false,
"sort_order": 92
},
{
"number": "94",
"title": "94. Certification regarding structural safety in design.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 93
},
{
"number": "95",
"title": "95. Constructional Safety.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 94
},
{
"number": "96",
"title": "96. Quality Control and Inspection.",
"chapter": null,
"content": "(i) Quality Auditor on Record (QAR) or Quality Auditor Agency on Record (QAAR) shall give a certificate of quality control as per model proforma provided in Form 13;.\n(ii) Quality Inspection Programme to be carried on the site shall be worked out by QAR/ QAAR in consultation with the owner, builder, CER/ CMAR.",
"footnote": "",
"is_definition": false,
"sort_order": 95
},
{
"number": "97",
"title": "97. Control of Signs (hoardings), transmission tower, telephone tower and outdoor display structures.",
"chapter": null,
"content": "(i) The telecommunication infrastructure shall be either placed on the building roof tops or on the ground or open space within the premises subject to other regulations.\n(ii) Type of structure\n(a) Steel fabricated tower or antennae on M.S. pole;\n(b) pre-fabricated shelters of fibre glass or P.V.C. on the building roof top/terrace for equipment;\n(c) masonry structure/ Shelter on the ground for equipment;\n(d) D.G. Set with sound proof cover to reduce the noise level.\n(iii) Requirement:-\n(a) every applicant has to obtain/ procure the necessary permission from the \"Standing Advisory Committee on Radio Frequency Allocation\" (SACFA) issued by the Ministry of Telecommunications;\n(b) every applicant shall have to produce the structural safety and stability certificate for the tower as well as the building from the Structural Engineer on Record (SER) which shall be the liability of both owner and SER;\n(c) applicant has to produce / submit plans of structure to be erected;\n(d) for Ground Base Transmission tower, the setback norms of Multi-storeyed commercial building shall apply;\n(e) for Roof Top Transmission Tower a minimum of 3m shall be provided from the edge of the outer frame of the building.\n(iv) Projection: No pager and/or telephone/transmission tower shall project beyond the existing building line of the building on which it is erected in any direction.",
"footnote": "",
"is_definition": false,
"sort_order": 96
},
{
"number": "98",
"title": "98. Maintenance of Buildings.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 97
},
{
"number": "99",
"title": "99. Protective Measures in Natural Hazard-Prone Areas.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 98
},
{
"number": "100",
"title": "100. Green Building Criteria.",
"chapter": null,
"content": "Chapter VII\nGuidelines for the Qualifications and Competence in Respect of the Proffessionals",
"footnote": "",
"is_definition": false,
"sort_order": 99
},
{
"number": "101",
"title": "101. Essential requirements.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 100
},
{
"number": "102",
"title": "102. Requirements for registration and competence of professionals.",
"chapter": null,
"content": "(a) The minimum qualifications for an architect shall be the qualifications as prescribed for in the Architects Act, 1972 for registration with the Council of Architects.\n(b) The registered Architect shall be competent to carry-out the work related to the building/ development permit as given below:-\n(i) all plans and information connected with building permit except engineering matters related to multistoried/ special buildings specified in these rules;\n(ii) issuing certificate of supervision and completion of all buildings pertaining to architectural aspects;\n(iii) preparation of sub-division/layout plans and related information connected with development permit of area upto 1 ha for metropolitan cities and 2 ha for other places;\n(iv) issuing certificate of supervision for development of land of area upto 1 hectare for metropolitan cities and 2 ha for other places.\n(a) The minimum qualification for an Engineer shall be graduate in civil engineering/ architectural engineering of recognized Indian or foreign university, or the Membership of the Institute of Civil Engineering Division/ Architectural Engineering Division of the Institution of Engineers (India) or of the statutory body governing such profession, as and when established.\n(b) The registered Engineers shall be competent to carry out the work related to the building/ development permit as given below:-\n(i) all plans and information connected with building permit;\n(ii) structural detail and calculations of buildings on plot upto 500 m2 and upto 5 stories or 16 m in height;\n(iii) issuing certificate of supervision and completion for all buildings;\n(iv) preparation of all service plans and related information connected with development permit; and\n(v) issuing certificate of supervision of land for all area.\n(a) The minimum qualification for an Electrical Engineer shall be Graduate in electrical engineering or electrical and electronics engineering or electrical and communication engineering from recognized Indian or foreign or membership of Institute of Electrical Engineering Division of the Institution of Engineers (India) or of statutory body governing such profession.\n(b) The registered Engineers shall be competent to carryout the work related to the building/ development permit as given below:-\n(i) all electrical and Telecom plan connected with the building permit;\n(ii) calculation of requirement of electrical energy power of the building and the sources from which the same shall be met (say ASEB supplies, solar power, wind power etc.)\n(iii) issuing certificate of supervision and completion of the electrical and Telecom plan of the building.\n(a) The minimum qualification of Structural Engineer shall be graduate in civil engineering of recognized Indian or foreign university, or Corporate Member of Civil Engineering Division of Institution of Engineers (India), with minimum 3 years experience in the practice of structural engineering with designing and field work.\nNote:- The 3 years experience shall be relaxed to 1 year in the case of postgraduate degree holder of recognized Indian or foreign university in the branch of structural engineering.\n(b) The registered Structural Engineers shall be competent to prepare the structural design, calculations and details for all buildings and supervision.\n(c) In case of buildings having special structural features, as decided by the Authority, which are within the horizontal areas and vertical limits specified in these rules, shall be designed by the Structural Engineers only.\n(a) The minimum qualifications for a supervisor shall be a Diploma in Civil Engineering or in Architecture with minimum 5 years experience in building designing, construction and supervision.\n(b) The registered Supervisor shall be competent to carryout the work related to the building permit as given below:-\n(i) all plans and related information connected with building permit for residential buildings on plot upto 100sq.m and upto two stories or 7.5 m in height; and\n(ii) issuing certificate of supervision for buildings as specified in these rules.\n(a) The minimum qualification for a Town Planner shall be the graduate/postgraduate degree in Town Planning from recognized Institute or qualifications required for Associate Membership of the Institute of Town Planers, India.\n(b) The registered Town Planner shall be competent to carry out the work related to the development permit as given below:-\n(i) preparation of plans for land sub-division/ layout and related information connected with development permit for all areas.\n(ii) issuing of certificate of supervision for development of land of-all-areas. However, for land layouts for development permit above 5 hectares in area, and for land development infrastructural services for roads, water supplies, sewerage/ drainage, electrification, etc, the registered Engineers for utility services shall be associated.\n(a) The minimum qualification for a landscape architect shall be the Bachelor or Master Degree in landscape Architecture or equivalent from recognised Indian or foreign university.\n(b) The registered landscape Architect shall be competent to carry out the work related to landscape design for building/ development permit for land upto 5 ha and above. For smaller areas below the limits indicated above, Association of landscape Architects may also be considered from the point of view of desired landscape development.\n(a) The minimum qualification for an Urban Designer shall be the Master Degree in urban design or equivalent from recognized Indian or foreign university.\n(b) The registered urban Designer shall be competent to carry out the work related to the building permit for urban design of land areas more than 5 hectares and campus area of more than 2 hectares. He/She shall also be competent to carry out the work of urban renewal for all areas. For smaller areas below the limits indicated above, Association of Urban Designer may be considered from the point of view of desired urban designing.\n(a) shall mean a Civil Engineer having at least 2 (two) years experience in soil and foundation engineering under similar soil/ geo-technical / soil condition.\n(b) To do all geo-technical investigation related to building construction.",
"footnote": "",
"is_definition": false,
"sort_order": 101
},
{
"number": "103",
"title": "103. Builder/ Constructor entity.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 102
},
{
"number": "104",
"title": "104. Group or Agency.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 103
},
{
"number": "105",
"title": "105. Annual Rate of License/ Enrolment Fees of Technical Personnel.",
"chapter": null,
"content": "(a) Rs. 1500.00 (Rupees one thousand five hundred) only per year.\n(b) Rs.500.00 (Rupees five hundred) only for a single multi storeyed commercial building, apartment, residential and others.\n(c) Rs. 250.00 (Rupees two hundred fifty) only for a single residential building.\n(a) Rs. 1000.00 (Rupees one thousand) only per year.\n(b) Rs. 500.00 (Rupees five hundred) only for single multistoried project.\n(c) Rs. 250.00 (Rupees two hundred fifty only) for a single residential building.",
"footnote": "",
"is_definition": false,
"sort_order": 104
},
{
"number": "106",
"title": "106. Procedure for Application or License/ Enrolment in the Authority.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 105
},
{
"number": "107",
"title": "107. Duties and responsibilities of Licensed Technical Personnel.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 106
},
{
"number": "108",
"title": "108. Penal action against defaulting Architects/ Engineers/ Groups/ Supervisors.",
"chapter": null,
"content": "Schedule I\n( See rule 57)\n( See rule 57)\nOccupant Load\nOccupant Load\nSl\nSl\nGroup of Occupancy\nGroup of Occupancy\nOccupant land Gross Area in sq.m/person*\nOccupant land Gross Area in sq.m/person*\n1\nResidential\n15\n2\nEducational\n12.5\n3\nInstitutional\n4\n4\nAssembly\na) With fixed/loose seats &\n\t\t\t\tdance floor\nb) Without seating facilities, including dining rooms\n15+\n0.6++\n1.5++\n5\nMercantile\na) Street floor & sales basement\n3\nb) Upper Sales Floor\n6\n6\nBusiness and Industrial\n10\n7\nStorage\n30\n8\nHazardous\n10\n*The gross area shall mean plinth area of covered area\n+ Occupant load in dormitory portions of homes for the aged, orphanages, insane, asylums, etc., where sleeping accommodation is provided, shall be calculated at not less than 7.5 sq.m. gross area/person\n++The gross area shall include in addition to the main assembly room or space, any occupied connecting room or space in the same storey or in the storey above or below where entrances is common to such rooms and spaces and they are available for use by the occupants of the assembly place. No deductions shall be made in the gross area for corridors, closets or other sub-divisions, the area shall include all space serving the particular assembly occupancy, passageway, to an internal stair-case/ramps or a verandah and/or terrace which have access to the street or to the roof of a building. An exit may also include a horizontal exit leading to an adjoining building at the same level; and Lifts and escalators shall not be considered as exits\nSchedule II\n( See rule 4)\n( See rule 4)\nDocuments to be submitted\nDocuments to be submitted\na) For buildings up to G+2\nUpto G+2\nUpto G+2\n1\nApplication form\n2\nLand Documents (Lease, POA, etc.)\n3\n3 Copies of Building Plans, including plan, sections,\n\t\t\t\televations, site plan and key map\n4\nService Plan, including parking and circulation\n5\nArea Statements\n6\nStructural Safety Certificates\nb) For Buildings of G+3 and above\nG+3 and above\nG+3 and above\n1\nAll of the above documents as given for Buildings up to G+2\n2\nDetailed Structural Design\n3\nSDB Report\n4\nArea Statement\n5\nForm 21\n6\nForm 22\n7\nSoil Test Report\n8\nWater Feasibility Report\n9\nRecommendations from Fire Services\n10\nCertificates from Registered Technical Persons\n11\nIndemnity Bond, where applicable\n(a) 4 sets of As-Built Completion Plan\n(b) NOC from Fire Services for Buildings of G+3 and Above\n(c) Lift Commissioning Certificate\n(d) Certificate of installation of DG sets, if any\n(a) Processing Fee along with Application form before construction\n(b) Building Permission after Approval of Building Plan (shall be collected with Processing fee and later adjusted)\nSchedule III\n(see rule 61)\n(see rule 61)\nProvisions for persons with disabilities\nProvisions for persons with disabilities\na. Site planning\na. Site planning\nEvery building shall have at least one access to main entrance / exit to the disabled which shall be indicated by proper signage. This entrance shall be approached through a ramp together with stepped entry. The ramp shall have a landing in front of the doorway.\nb. Parking\nb. Parking\n(i) Surface parking for at least two Car Spaces shall be provided near entrance for the physically handicapped persons with maximum travel distance of 30 m from building entrance.\n(ii) The width of parking bay shall be minimum 3.6 m\n(iii) The information stating that the space is reserved for wheel chair users shall be conspicuously displayed.\nc. Building requirements\nc. Building requirements\n(i) For approach to the plinth level, and in other levels where ramps with gradients are necessary or desired they shall conform to the following requirements.\n(a) Ramps slope shall not be steeper than 1 in 12\n(b) Its length shall not exceed 9 m between landings and its width shall be minimum 1.5 m with handrails on either side.\n(c) Its surface shall be non slippery\n(d) Minimum size of landing shall be 1 m x 2 m.\n(ii) Among the lifts provided within the premises at least one lift shall have the facility to accommodate the wheel chair size 80 cm x 150 cm.\n(iii) The doors and doorways shall be provided with adequate width for free movement of the disabled persons and it shall not be less than 90 cm.\n(iv) Stairs shall have the handrail facilities as prescribed in the National Building Code.\nSchedule IV\n{(see rule 10(xix)}\n{(see rule 10(xix)}\nSolar Energy Capture\nSolar Energy Capture\n(a) Nursing Homes / Hospitals exceeding 500 sq.m.in the floor area;\n(b) Hotels and Lodges exceeding 500sq.m.in floor area;\n(c) Hostels exceeding 50 rooms;\nSchedule V\n(See rule 100)\n(See rule 100)\nGreen Building Certification\nGreen Building Certification\n(a) Criterions for certification\n(b) Procedure of Certification\nSchedule VI (see Rule 82) Rainwater harvesting methods\n(see Rule 82) Rainwater harvesting methods\n(see Rule 82)\nRainwater harvesting methods\nRainwater harvesting methods\nSchedule VII\n(see rule 10)\n(see rule 10)\nIndemnity Bond for Basement/ Building/ Wall (For Authority)\nIndemnity Bond for Basement/ Building/ Wall (For Authority)\n(Executants)\nSchedule-VIII\n(see rule 18)\n(see rule 18)\n(i) Rate of application fees for erection of new residential building (including group housing, institutional building religious, cultural etc.) shall be as under -\nType I\nType I\nType II\nType II\nType III\nType III\nAssam type pitched\n\t\t\t\troof with C.I. or A.C. sheets timer framed structure with Ekra or\n\t\t\t\tspilt bamboos walls with plaster.\nRs.2.00 per sq.m.\nPitched roof with\n\t\t\t\tC.I. or A.C. sheet R.C.C. or R.B. column or posts, brick with\n\t\t\t\tcement plaster walls.\nRs.3.00 per sq.m.\nR.C.C. Type\nRs.10.00 per sq.m. of plinth area for ground\n\t\t\t\tfloor and additional Rs.2.00 per sq.m of floor area for each\n\t\t\t\tsubsequent floors. When the top floor is of pitched roof this\n\t\t\t\tfloor shall be considered as of type I or II as per nature or\n\t\t\t\tconstruction and the fees shall be calculated accordingly.\n(a) General commercial - 4 times of the rate of new residential building.\n(b) Industrial and godowns - 5 times of the rate of new residential building,\n(c) Others - 2 times of the rate of new residential building (also includes apartments, schools, hospitals).\n(a) Five times the rate of normal permission fees ; for residential, public and semi public, institutional, educational buildings\n(b) Ten times the rate of normal permission fees; for commercial, apartment, industrial and similar buildings\n(c) For incomplete building, compounding fee shall be calculated on the pro rata basis\n(a) For residential, public and Semi public, institutional etc. the rate of fees shall be Rs.20.00 per unit as per Zoning Plan subject to a minimum of Rs.50.00.\n(b) For Commercial, industrial, etc. the rate of fees shall be Rs.60.00 per Zoning subject to a minimum or Rs.150.00.\nResidential\nNon-residential, except Filling Station and\n\t\t\t\tTheatre\nFilling Station/ Medium/ Industry\nCinema/ Theatre\nHuts and temporary sheds\nOther\nHuts and temporary sheds\nOther including light Industry\nRs.50/-\n250/-\n100/-\n500/-\n1000/-\n1500/-\n(i) Fees for appeal of residential building of any type Rs.100.00 on flat rate basis\n(ii) Fees for non residential building Rs.200.00 flat rate basis\n(iii) Fees for Cinema, Theatre Rs.1000.00 on flat rate basis\n(iv) Fees for Filling Station etc. Rs.1000.00 on flat rate basis\nMiscellaneous Fees item\nMiscellaneous Fees item\nRate of Fees\nRate of Fees\n(i) Renewal of Building permission\n15% of the fees paid for the original permit.\n(ii) Duplicate copy of NOC\nRs.50/- per copy.\n(iii) Attested of duplicate copies of approved\n\t\t\t\tplan.\nRs.50/- per copy.\n(iv) For furnish copies of map.\nRs.25/- per copy.\n(v) Fees for revision of plan after approval.\n15% of the fees paid for original permit plus\n\t\t\t\tadditional fees for additional area if any.\n(i) A.T. building - 100/-.\n(ii) For building upto G+2 floor - Rs.200/- (Rupees Two hundred) only.\n(iii) For building above G+2 floor - Rs.500/- (Rupees Five hundred) only\n(iv) Above 2nd floor added - Rs.500/- per floor.\nForms\nForms\nForm 1\nForm 1\n( See Rule 3)\n( See Rule 3)\n(To be submitted in duplicate)\nApplication Form to Erect, Re-Erect or to Make Material Alternation in a Building\nApplication Form to Erect, Re-Erect or to Make Material Alternation in a Building\nChairman (MB/TC/etc)\nI/We hereby give notice that I intend to erect/re-erect or to make alteration in the House No ........................... situated at Road............................................................ of ................................................area of Ward No................ in Dag No.......................................... Patta No........................................................ of Revenue Village....................................................... Mouza........................................... and in accordance with the Building Byelaws of Assam and I forward herewith, the following plans and specifications duly signed by me and............................................................................................................................. (Name in block letters)of the Registered Technical Personal, Registration No.................................................... who have prepared the plans, statements/documents (as applicable).\na) Three copies of site plan and building plan as required by building bye laws, ASSAM, and drawn by Technical Personal registered in MB/TC\nb) Photostat Copy of land document (Such as land deed, Mutation order or Patta). The photocopy is to be self attested.\nc) Structural Certificate (as per building bye laws of 2006) issued by Technical Personal / Group Agency Registered in MB/TC.\nd) Service plan for building when it is above 12.00 m high.\ne) For boundary wall permission; an undertaking through affidavit shall be required particularly for road side wall.\nf) Key plan of the location.\ng) Soil test report (Geo-Technical Report) in case of building above 12.00 m high.\nh) Trace Map.\ni) Receipt Copy of up-to-date property tax.\nThe schedule of the land is also given below:-\n(a) Total plot area :- ..................................................\n(b) Name of owners of adjoining land\nNorth :- ..................................................\nSouth :- ..................................................\nEast :- ..................................................\nWest :- ..................................................\n(c) Is there any future provision for\n(i) Vertical extension\n(ii) Horizontal extension\n(iii) If yes No. of floors\nFOR OFFICE USE\nB.P. fees Received Rs.\n\t\t\t\t........................................................................................................\n(Rupees\n.......................................................................................\n.......................................................................................\n...................................................)\n\t\t\t\tonly .\nRt.\n\t\t\t\tNo............................... Book\n\t\t\t\tNo.................................\nDate\n\t\t\t\t......................................\n(Cashier)\nSl.No:.............\nRt.No: ..........\nDate ..............\nNote :-",
"footnote": "",
"is_definition": false,
"sort_order": 107
},
{
"number": "1",
"title": "1. The site to be shown to the concern Zonal Engineer within 7 days.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 108
},
{
"number": "2",
"title": "2. You are to contact to office counter of the building permission branch within 30 (thirty) days from the date of submission for further information.",
"chapter": null,
"content": "Fees to be paid:-\nRs......................................................................................................\n.........................................................................................................\n.........................................................................................................\n.... only for\n\t\t\t\tconstruction of RCC / Boundary Wall / AT building for\n.....................................................use.\nZonal Engineer\nForm 2\nForm 2\n{see rule 19(2)}\n{see rule 19(2)}\nAuthority Letter\nAuthority Letter\nForm 3\nForm 3\n{See rule 19(2)}\n{See rule 19(2)}\nBuilding Permit\nBuilding Permit\n.............................................\n.............................................\n.............................................\nSub: No Objection Certificate for Construction\nWith reference to your above application for permission to erect/re-erect/add to/alter a / a building at .................................................. is hereby accorded and you are required to comply with the conditions mentioned overleaf in accordance with plan submitted with / without modification. The particulars of the construction for which permission accorded is given below.\nProposed use\nNo of floors\nZone\nType of construction\nParking (no.& area)\nBasement\nGround\nOpen\nMargins (setbacks)\nNorth\nArea of Floors\nBasement\nSouth\nGround\nMezz. Floor\nEast\nFirst\nWest\nSecond\nCantilever\nNorth\nThird\nSouth\nFourth\nEast\nFifth\nWest\nSixth\nDetails of land\nDag no\nSeventh\nPatta no\nEight\nWard no\nNinth\nName of road : mouza / vill:\nTenth\nLength of b/wall\nHeight of b/wall\nNote: Add additional floor if required.\nYour's faithfully,\nChairman\nMB/TC\nChairman\nMB/TC\nNotice",
"footnote": "",
"is_definition": false,
"sort_order": 109
},
{
"number": "1",
"title": "1. This Permit shall remain valid up to two years only from the date of issue of the permit.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 110
},
{
"number": "2",
"title": "2. The Permit is not transferable.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 111
},
{
"number": "3",
"title": "3. The owner upon commencement of his work under a no-objection certificate shall give Notice to MB/TC that he has started his work and Authority shall cause inspection of the work to be made within 14 days following receipt of notice to verify that the building has been erected in accordance with the sanctioned plans.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 112
},
{
"number": "4",
"title": "4. Shall the MB/TC determine at any stage that the layout or the construction is not proceeding according to the sanctioned plan or is in violation of any provision of the Act, it shall serve a notice on the applicant requiring him to stay further execution until correction has been made in accordance with the approved plan.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 113
},
{
"number": "5",
"title": "5. If the Permit holder fails to comply with the requirements at any stage of construction the MB/TC is empowered to cancel the building permit issued.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 114
},
{
"number": "6",
"title": "6. Every person who erects or re-erects any building shall within one month of the completion of the work deliver to the MB/TC a notice in writing of such completion and shall give him all necessary facilities for the inspection of such works as provided in the Building Bye-laws.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 115
},
{
"number": "7",
"title": "7. Whenever asked by the MB/TC or his subordinates, the Permit holder shall produce the Permit along with the copy of the approved plan for verification.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 116
},
{
"number": "8",
"title": "8. In the event of reclamation of the plot for construction of building/boundary wall the reclamation level shall not exceed the level of the nearest P.W.D. or MB/TC Road. For preparation of hilly land for construction, retaining wall has to be constructed on the excavated earth and spoils shall be adequately guarded to prevent erosion.",
"chapter": null,
"content": "Conditions\n1. \"M/S ............................ '' along with the builder shall be held responsible for any kind of structural failure of the building.",
"footnote": "",
"is_definition": false,
"sort_order": 117
},
{
"number": "2",
"title": "2. N.O.C. from Director of FIRE Service is to obtained for the building.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 118
},
{
"number": "3",
"title": "3. Necessary fire fighting facilities are to be provided in and around the building.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 119
},
{
"number": "4",
"title": "4. The Road side drain along with the Road is to be constructed at the cost of the builder connecting main outlet of the area.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 120
},
{
"number": "5",
"title": "5. Before installation of Deep Tube Well, N.O.C. from Central Ground Water Board is to be obtained.",
"chapter": null,
"content": "6. \"CHUTES\" are to be provided inside the building for garbage disposal.",
"footnote": "",
"is_definition": false,
"sort_order": 121
},
{
"number": "7",
"title": "7. At least 2 nos. of DUST BIN are to be placed near the plot at the cost of the builder.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 122
},
{
"number": "8",
"title": "8. Planning of minimum 10 nos. of evergreen trees inside the plot on the date of commencement of construction and be maintained.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 123
},
{
"number": "9",
"title": "9. The owner through the licensed architect, engineer, as the case may be (RTP) who has supervised the construction, shall give notice to the Authority regarding completion of work and obtain \"Occupancy Certificate\" before occupying the building.",
"chapter": null,
"content": "Form 4\nForm 4\n{see rule 19(2)}\n{see rule 19(2)}\nForm for Refusal of Building Permit\nForm for Refusal of Building Permit\nWith reference to your application No. ................................. dated ............for the grant of sanction for the erection of building/ execution of work in House No. ......\n1.\n2.\n3.\n4.\n5.\nYours faithfully,\nAuthority\nForm 5\nForm 5\n(See rule 97)\n(See rule 97)\nForms for Compliance\nForms for Compliance\nSignature\n(Authorized signatory)\nForm No 6\nForm No 6\n{(See Rule 76(6) (V)}\n{(See Rule 76(6) (V)}\nProgress Certificate\nProgress Certificate\nWe hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached the Plinth Level and is executed under our supervision. We declare that the amended plan is not necessary at this stage.\nSignature of the\nSignature of the\nConstruction Engineer on Record\nOwner/ Development/ Builder\nDate :______________________\nDate :___________________\nName in block letters :-\nName in block letters :-\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm 7\nForm 7\n{See rule 76 (6) (v)}\n{See rule 76 (6) (v)}\nProgress Certificate - First Storey\nProgress Certificate - First Storey\nWe hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached the first storey level and is executed under our supervision.\nSignature of the\nSignature of the\nConstruction Engineer on Record\nOwner/ Development/ Builder\nDate :- ______________________\nDate :- ___________________\nName in block letters : -\nName in block letters :\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm 8\nForm 8\n{See rule 76 (6) (v)}\n{See rule 76 (6) (v)}\nProgress Certificate - Middle Storey In Case Of High-Rise Building\nProgress Certificate - Middle Storey In Case Of High-Rise Building\nWe hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached _________________ storey level and is executed under our supervision.\nSignature of the\nSignature of the\nConstruction Engineer on Record\nOwner/ Development/ Builder\nDate :- ______________________\nDate :- ___________________\nName in block letters : -\nName in block letters :\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm 9\nForm 9\n{ See rule 76 (6) (v)}\n{ See rule 76 (6) (v)}\nProgress Certificate - Last Storey\nProgress Certificate - Last Storey\nWe hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached _________________ storey level and is executed under our supervision.\nSignature of the\nSignature of the\nConstruction Engineer on Record\nOwner/ Development/ Builder\nDate :- ______________________\nDate :- ___________________\nName in block letters : -\nName in block letters :\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm 10\nForm 10\n(See rule 30)\n(See rule 30)\nBuilding Completion Certificate by Architect on Record\nBuilding Completion Certificate by Architect on Record",
"footnote": "",
"is_definition": false,
"sort_order": 124
},
{
"number": "1",
"title": "1. The building/s has/have been constructed according to the sanctioned plan.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 125
},
{
"number": "2",
"title": "2. The building/s has/have been constructed as per approved plan and design as per detailed architectural drawings and specifications prepared by Architect on Record.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 126
},
{
"number": "3",
"title": "3. Construction has been done under our supervision / guidance and adheres to the drawings submitted.",
"chapter": null,
"content": "Signature of the Owner\nSignature of Architect on Record\nDate :- ______________________\nDate :- ___________________\nName in block letters :-\nName in block letters :-\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm 11\nForm 11\n( See rules 30 and 95)\n( See rules 30 and 95)\nBuilding Completion Certificate by Construction Engineer on Record\nBuilding Completion Certificate by Construction Engineer on Record",
"footnote": "",
"is_definition": false,
"sort_order": 127
},
{
"number": "1",
"title": "1. The building/s has/have been constructed according to the sanctioned plan.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 128
},
{
"number": "2",
"title": "2. The building/s has/have been constructed as per",
"chapter": null,
"content": "(i) the detailed structural drawings and structural specifications prepared by the Structural Engineer on Record.\n(ii) the detailed Architectural drawings and Architectural specifications prepared by the Architect on Record.\n(iii)detailed drawings and specifications of all services.",
"footnote": "",
"is_definition": false,
"sort_order": 129
},
{
"number": "3",
"title": "3. All materials used in the construction have been tested as provided in specifications and a record of test reports has been kept.",
"chapter": null,
"content": "Signature of the Owner Record\nSignature of Construction Engineer on\nDate :- ______________________\nDate :- ___________________\nName in block letters :-\nName in block letters :-\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm12\nForm12\n(See rules 30 and 94)\n(See rules 30 and 94)\nBuilding Completion Certificate by Structural Engineer on Record\nBuilding Completion Certificate by Structural Engineer on Record\nThis is to certify that detailed structural drawings of the building/s has/have been prepared on the basis of a detailed analysis and a detailed design carried out according to relevant provisions of the latest Indian Standard Codes, National Building Code and as indicated in the structural design basis report.\nSignature of the Owner\nSignature of Construction Engineer on Record\nDate :- ______________________\nDate :- ___________________\nName in block letters :-\nName in block letters :-\nName in block letters :-\nName in block letters :-\n___________________________\n___________________________\nAddress ____________________\nAddress ____________________\n___________________________\n___________________________\n___________________________\n___________________________\nForm 13\nForm 13\n( See rule 96)\n( See rule 96)\nModel Proforma for Technical Audit Report\nModel Proforma for Technical Audit Report",
"footnote": "",
"is_definition": false,
"sort_order": 130
},
{
"number": "1",
"title": "1. Design",
"chapter": null,
"content": "COMMENTS\n1.1 Design / Drawings available\nY/N\nDesign Category\nType Design?\nSpecific design?\nY/N\nDesign to be collected to refer to Design Consultant / H.O.\nDrawings prepared / checked by competent Authority ?\nY/N\nDesign Drawings / details\nY/N\nStructural detailed included\nEarthquake / cyclone resistant features included?\nDesign verified / vetted by Dept. / Government approved agency /\n\t\t\t\tcompetent authority?\nY/N\nDesign changes approved by Dept. / Government approved agency /\n\t\t\t\tcompetent authority?\nY/N",
"footnote": "",
"is_definition": false,
"sort_order": 131
},
{
"number": "2",
"title": "2. Foundation",
"chapter": null,
"content": "2.1\nFoundation used\nExisting/New\n2.2.1\nIf existing foundation used\nIf existing foundation used\n2.2.1\nDepth of foundation below ground\n:\n<50cm/50-70/>70cm\n2.2.2\nType of foundation\n:\nIsolated/Combined/Raft/Piled etc.\n2.2.3\nThickness of masonry (above ground)\n:\n2.2.4\nMortar used and Mix of cement mortar\n:\nCement-Sand/Lime and 1:4/1:6/Leaner\n2.2.5\nGrade of concrete (M20)\n:\nY/N\n2.2.6\nHeight up to Plinth\n:\n________________ cm\n2.2.7\nIf stone masonry\n2.2.7.1\nThrough Stones\n:\nYes/No, if Yes Adequate / Inadequate\n2.2.7.2\nCorner Stones\n:\nYes/No, if Yes Adequate/Inadequate\n2.3\nIf new foundation used\n2.3.1\nDepth of foundation below ground\n:\n_____ <50/50-70/>70cm\n2.3.2\nType of foundation\n:\nIsolated/Combined/Raft/Piled etc.\n2.3.3\nThickness of Masonry above plinth\n:\n____________________________\n2.3.4\nMortar used and Mix of cement mortar (1:4)\n:\nCement - sand/lime/mud and Y/N\n2.3.5\nGrade of concrete (M20)\n:\nY/N\n2.3.6\nHeight up to Plinth\n:\n<60/>60cm\n2.3.7\nIf stone masonry\n2.3.7.1\nThrough Stones\n:\nYes/No, if Yes Adequate/Inadequate\n2.3.7.2\nCorner Stones\n:\nYes/No, if Yes Adequate/Inadequate\n2.3.7.3.\nVertical reinforcement in foundation\n:\nYes/No\n3\nWalling\nWalling\n3.1\nType of masonry\n:\nBrick/PCC Blocks/ Stone\n3.2\nMortar used\n:\nCement - Sand/Lime\n3.3\nMix of cement mortar\n:\n1:4/1:6/Leaner\n3.4\nThickness of wall\n:\n>23cm/23cm/23cm\n3.5\nMixing of mortar\n:\nOK/Not OK\n3.6\nJoint Property filled\n:\nOK/NOT OK\n3.7\nWetting of bricks\n:\nGood/ Medium/ Poor\n3.8\nIf stone masonry\n3.8.1\nThrough Stones\n:\nYes/No\n3.8.2\nCorner Stones\n:\nYes/No\n3.9\nOverall workmanship\n:\nGood / Medium / Poor\n4\nRoofing\nRoofing\n4.1\nType of roof\n:\nFlat/Sloping\n4.2\nIf sloped\n:\nA.C. sheet/ G.I. sheet /Morbid tiles\n4.3\nPurlins\n:\nAngle-Iron / Timber / NA\n4.4\nTruss type :- _______________________\n4.5\nAnchorage with wall\n:\nAdequate/ Inadequate/ NA\n5\nMaterials\nMaterials\n5.1\nCement\n5.1.1\nSource\n:\nAuthorized Dealer/ Market\n5.1.2\nType of cement\n:\nOPC/PPC/PSC\n5.1.3\nIf OPC\n:\nGrade (33/ 43/ 53)\n5.2\nSand\n5.2.1\nType of sand\n:\nRiver sand / Stone dust\n5.2.2\nPresence of deleterious materials\n:\nMild / Moderate/ High\n5.3\nCoarse Aggregates\n5.3.1\nType coarse Aggregates\n:\nGravel/ Crushed Stone\n5.3.2\nPresence of deleterious material\n:\nMild/ Moderate / High\n5.4\nP.C.C. Blocks (Applicable for onsite production)\n5.4.1\nType of P.C.C. Blocks\n:\nSolid blocks/Hollow blocks\n5.4.2\nRatio of concrete in blocks\n:\n______________________\n5.4.3\nInterlocking feature\n:\nYes/No\n5.4.4\nCourse aggregates used\n:\nNatural/ Crushed stone\n5.5\nBricks Blocks, Stone etc.\n5.5.1\nStrength (field assessment)\n:\nLow/Medium/High\n5.5.2\nDimensional accuracy\n:\nYes/No\n5.6\nConcrete\n5.6.1.\nMix of concrete\n:\nM20/Design Mix\n5.6.2\nBatching\n:\nWeigh batching/Volume batching\n5.6.3\nCompaction\n:\nVibrators/Thappies and rods\n5.6.4\nWorkability\n:\nLow / Medium / High\n5.6.5\nAvailability of water\n:\nOptimum/Sufficient / Insufficient\n5.6.6\nCuring\n:\nSatisfactory/Unsatisfactory.\n5.7\nReinforcing Steel\n5.7.1\nType of Steel\n:\nPlain mild steel/HYSD bars\n5.7.2\nSource :Authorised Dealer/Market\n5.7.3\nWhether IS marked\n:\nYes/No\n5.7.4\nConditions of bars\n:\nClean/Corroded\n5.7.5\nFixing of reinforcement as per drawing\n:\nYes/No\n5.7.6\nSuitable cover\n:\nYes/No\n5.7.7\nSpacing of bars\n:\nRegular/Irregular\n5.7.8\nOverlaps as per specifications\n:\nYes/ No\n5.8\nForm Work\n5.8.1\nType of Form Work\n:\nTimber / Plyboard/ Steel\n5.8.2\nUse of mould oil\n:\nYes/No\n5.8.3\nLeakage of cement slurry\n:\nObserved/Not observed\n5.9\nSource\n5.9.1\nCement\n5.9.2\nSand\n5.9.3\nCoarse Agg.\n5.9.4\nBricks\n5.9.5\nPCC blocks.\n6\nSeismic resistance features\nSeismic resistance features\n6.1\nMasonry Structures\n6.1.1\nProvision of bands at Provided Adequate\n6.1.1.1\nPlinth level\nYes/No\nYes/No\n6.1.1.2\nSill level\nYes/No\nYes/No\n6.1.1.3\nLintel level\nYes/No\nYes/No\n6.1.1.4\nRoof level (if applicable)\nYes/No\nYes/No\n6.1.2\nIf sloped Roof, whether seismic bands are provide at\n6.1.2.1\nGable wall top\nYes/No\nYes/No\n6.1.2.2\nEaves level\nYes/No\nYes/No\n6.1.3\nProvision of vertical steel in masonry at Provided Adequate\n6.1.3.1\nEach corner\nYes/No\nYes/No\n6.1.3.2\nEach T-junction\nYes/No\nYes/No\n6.1.3.3\nEach door joint\nYes/No\nYes/No\n6.1.3.4\nAround each window\nYes/No\nYes/No\n6.1.4\nOpenings\n6.1.4.1\nTotal width of openings\n:<50%/50*-60%/>60%\n(*-42% for double storey)\n6.1.4.2\nClearance from corner\n:OK/Not OK\n6.1.4.3\nPier width between two openings\n: OK/Not OK\n6.2\nFramed Structures\n6.2.1\nDuctile detailing\n6.2.1.1\nSpacing of stirrup\n:OK/Not OK\n6.2.1.2\nSizes of members\n:OK/Not OK\n6.2.1.3\nEnd anchorage\n:OK/Not OK\n6.2.1.4\nLapping (length, location etc.)\n:OK/Not OK\n6.2.1.5\nAngle of stirrup hook\n:90 / 135 degrees\n6.3\nAny testing carried out by Owner/Engg. Supervisor on\nTesting done\nTesting results\n6.3.1\nWater\nYes/No\nOK/Not OK\n6.3.2\nCement\nYes/No\nOK/Not OK\n6.3.3\nBricks/PCC blocks/Stones\nYes/No\nOK/Not OK\n6.3.4\nAggregate\nYes/No\nOK/Not OK\n6.3.5\nMortar\nYes/No\nOK/Not OK\n6.3.6\nConcrete\nYes/No\nOK/Not OK\n6.3.7\nReinforcement\nYes/No\nOK/Not OK\nForm 14\nForm 14\n( See rule 94)\n( See rule 94)\nStructural Inspection Report\nStructural Inspection Report\nI. Description by title and location of the property\nII. Name of the present owner :\nIII. Description of the structure :\nClass I or Class II (Briefly describe the property in general and the structure in particular)\n(a) Function (b) Framed construction\nResidence (with or without shops)\nApartments (with or without shops)\nOffice Building\nShopping Centre\nSchool, College\nHostel\nAuditoria\nFactory\n1\n1\n2\n2\n3\n3\n4\n4\n5\n5\n6\n6\n7\n7\n8\n8\n9\n9\nA. Load bearing masonry wall construction\nB. Framed structure construction\nConstruction and structural materials\nCritical load bearing element\nBrick\nRCC\nStone\nTimber\nSteel\nRoof Floor\nRCC\nTimber\nRBC\nSteel\nJackarch\nIV. Year of construction\nYear of subsequent additions or rectification's (Please describe briefly the nature of additions or rectification's) :\nV. date of last inspection report field :Last filed by whom (This does not apply to the first report) :\nVI. Soil on which building is founded :-\ni) Any change subsequent to construction :\nii) Nearby open excavation :\niii) Nearby collection of water :\niv) Proximity of drain :\nv) Underground water-tank :\nvi) R.W. Pipes out-lets :\nvii) Settlements :\nVII. The Super-structure (R.C.C. Frame Structure)\ni) Crack in beam or column nature and extent of crack probable causes. :\nii) Cover spell :\niii) Exposure of reinforcement :\niv) Subsequent damage by user for taking pipes, conduits, hanging, fans or any other fixtures, etc. :\nv) Crack in slab :\nvi) Spalling of concrete or plaster of slab :\nvii) Corrosion of reinforcement :\nviii) Loads in excess of design loads :\nVIII. The Super-structure (Steel Structure)\ni) Paintings :\nii) Corrosion :\niii) Joint, nuts, bolts, rivets, welds, gusset plates :\niv) Bending or buckling of members :\nv) Base plate connections with columns or pedestals :\nvi) Loading :\nIX. The Super-structure (Load bearing masonry structure) Cracks in masonry walls\n(Please describe some of the major cracks, their nature, extent and location, with a sketch, if necessary. :\nX. Recommendations if any :\nThis is to certify that the above is a correct representation of facts as given to me by the owner and as determined by me after Site Inspection to the best of my ability and judgment.\nThe recommendations made by me to ensure adequate safety of the structure are compiled with by the owner to my entire satisfaction.\nForm 15\nForm 15\n( see rule 91)\n( see rule 91)\nStructural Design Basis Report\nStructural Design Basis Report\nSl. No.\nSl. No.\nDescription\nDescription\nInformation\nInformation\nNotes\nNotes\n1\nAddress of the building\n• Name of the building\n• Plot number\n• Sub plot number\n• TPS scheme\na. Name\nb. Number\n• Locality/ Township\n• District\n2\nName of owner\n3\nName of Builder on record\n4\nName of Architect/ Engineer on record\n5\nName of Structural engineer on record\n6\nUse of the Building\n7\nNumber of storeys above ground level (including storeys to be\n\t\t\t\tadded later, if any)\n8\nNumber of basements below ground level\n9\nType of structure\nType of structure\n• Load bearing walls\n• RCC frame\n• RCC frame and Shear walls\n• Steel frame\n10\nSoil data\nSoil data\n• Type of soil\n• Design safe bearing capacity\nIS1893 Cl.6.3.5.2 IS:-1904\n11\nDead loads (unit weight adopted)\nDead loads (unit weight adopted)\n• Earth\n• Water\n• Brick masonry\n• Plain cement concrete\n• Reinforced cement concrete\n• Floor finish\n• Other fill materials\n• Piazza floor fill and landscape\nIS:-875 Part1\n12\nImposed (live) loads\nImposed (live) loads\n• Piazza floor accessible to\n\t\t\t\tFire Tender\n• Piazza Floor not accessible\n\t\t\t\tto Fire tender\n• Floor loads\n• Roof loads\nIS:-875 Part2\nForm 16\nForm 16\n( See rule 30)\n( See rule 30)\nCompletion Report\nThe work of erection/re-erection of building as per approved plan is completedunder the Supervision of Architect/Construction Engineer who have given the completion certificate which is enclosed herewith.\nWe declare that the work is executed as per the provisions of the Act and Development Control Regulations and to our satisfaction. We declare that the construction is to be used for ______________ the purpose as per approved plan and it shall not be changed without obtaining written permission.\nWe hereby declare that the plan as per the building erected has been submitted and approved. We have transferred the area of parking space provided as per approved plan to an individual/association before for occupancy certificate.\nYours faithfully,\nForm 17\nForm 17\n(See Rule 91)\n(See Rule 91)\nCertificate of Undertaking of Structural Engineer on Record (SER)\nCertificate of Undertaking of Structural Engineer on Record (SER)\n(Title of the project)\nI undertake to carry out a detailed structural design and prepare detailed structural drawings of the proposed building as per the latest Indian Standard Specifications, and as indicated in the Structural design basis report.\nI undertake to supply the owner and the supervisor the detailed structural drawings. If my services are terminated, I undertake to intimate the Authority in writing.\nForm 18\nForm 18\n(see rule 106)\n(see rule 106)\nI hereby apply for enrolment of my name as competent Technical personnel to do the various works of schemes for Building Permit and supervision in the _____________________.\nI do hereby also declare that I shall follow and shall abide by all the Rules and Regulations now in force and that may be framed from time.\nMy personal bio-data are as follows-\nSignature :\nDated :\nForm 19\nForm 19\n(see rule 106)\n(see rule 106)\nApplication for Enrolment as Competent Technical Personnel in the .........................\nApplication for Enrolment as Competent Technical Personnel in the .........................\nWe hereby apply for enrolment of our Group or Agency in the name and style as mentioned below, as competent technical personnel to do the various works of schemes for Building Permit and supervision in the ____________________\nWe do hereby also declare that we shall follow and shall abide by all the Rules and Regulations now in force and that may be framed from time to time. Name of the group and persons associated with personal bio-data are as follows-\nwith his/ her personal capacity and rank and personal bio-data (Certificates enclosed)\n(A)\n(B)\n(C)\n(D)\nSignature of head of the group or agency\nForm-20\nForm-20\n(See Rule 76)\n(See Rule 76)\nArea Statement\nArea Statement\n(A) Plot area:.............................................................................................................................\n(B) Plinth area\n(I) Existing plinth Area (if any):....................................................................................\n(II) Proposed plinth Area:.................................................................................................\n(C) Floor area showing detail calculation of each floor (Existing + Proposed):................................................................................................................................................\n(D) Detail of mezzanine floor area:.......................................................................................\n(E) Deduction showing detail calculation of each floor (Existing + Proposed):..........................................................................................................................................\n(F) Total floor area after deduction (Existing + Proposed):..............................................................................................................................................................................................\n(G) Total floor area before deduction (Existing + Proposed):......................................................................................................................................................................................\n(H) Coverage (Existing + Proposed):...................................................................................\n(I) Floor Area Ratio (FAR) (Existing + Proposed):............................................................................................................................... ......................................................................\nSignature of the owners:\nSignature of registered Architect/Engineer/supervisor\nName of owner(s):\nRegistration no. of the Architect/Engineer/supervisor:\nAddress of the owner(s):\nAddress of the Architect/Engineer/supervisor:\nDated:\nDated:\nForm-21\nForm-21\n( See Rule 76)\n( See Rule 76)\nStatement of the Proposal and Certificate\nStatement of the Proposal and Certificate\nBy the Owner and Registered Architect\nSl. No.\nExisting road width\nProposed road width\nRemarks\n(a) As per site plan :.....................................................................................\n(b) As per land document :.....................................................................................\nDescription\nProposed sq. mt.\nUse\nPermissible (For office use)\nRemarks\nMax. ground coverage\nBasement\nGround floor\nMezzanine\nFirst floor\nSecond floor\nThird floor\nFourth floor\nFifth floor\nSixth floor\nSeventh floor\nEighth floor\nNinth floor\nTenth floor\nService floor (if any)\nTotal floor area\nFloor area ratio\nNo. of Dwelling units\n(a) Maximum height of building (in meter):- ........................................\n(b) Maximum height of the plinth (in meter):- .......................................\nSetbacks\nProposed\nRequired as per byelaws (For office use)\nRemarks\nClear setback(in meter)\nCantilever projection over setback (in meter)\nClear setback (in meter\nCantilever projection over setback (in meter\nFront\nRear\nLeft\nRight\nNo. of duct\nArea of duct (in sq. mt.)\nMinimum width of the shaft (in meter)\nNature of electric line\nVertical distance (in meter)\nHorizontal distance (in meter)\n(A) Parking provided as per Building Byelaws:\nOpen parking\nStilt parking or ground floor covered parking\nBasement parking\nTotal no. of parking\n(B) Parking required as per Appendix-I Byelaws (For office use):\nSl. No.\nType of use of building\nCAR parking\nScooter parking\nRemarks\n(C) Visitor's car/Scooter parking required as per the Byelaws:-\nSl. No.\nType of use of building\nCar parking\nScooter parking\n(a) Building permit fee\n:\nRs. ...............\n(b) Use of city infrastructure charges\n:\nRs. ...............\n(c) Additional floor space charges (provisional)\n:\nRs. ...............\n(d) Peripheral charges (if any)\n:\nRs. ...............\n(e) Any other charges (if any, please specify)\n:\nRs. ...............\nTotal amount (as per detail above)\nRs. ...............\n(1) The title document is to justify the ownership of land and its sub-division was duly approved by the Authority before registration of the land sale deed. (2) Plot is lying vacant and no construction shall be started before sanction. (3) The plot is free from all encumbrances (owner responsibility). (4) Building shall not be occupied before getting occupancy certificate dully issued by Authority. (5) Supervision in the manner prescribed shall be conducted with intimation to the Authority. (6) Mandatory provision of rainwater harvesting is to be provided. (7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated: Form-22 ( See rule 76) (For above G+2) Form for specification of proposed building (1) The purpose (Residence, Office, Restaurant, Hotel, Dharamshala, School, Hostel, Cinema, Shop, Factory. Others) for which it is intended to be used................................................................................................................ .................................................................................................... (2) Details of Area on respective floor are given below Floor Existing (sq. mt.) Proposed (sq. mt.) Total (sq. mt.) 1 Basement 2 Ground 3 Mezzanine 4 First floor 5 Second floor 6 Third 7 8 9 10 Service floor (if any) (3)\n(2) Plot is lying vacant and no construction shall be started before sanction. (3) The plot is free from all encumbrances (owner responsibility). (4) Building shall not be occupied before getting occupancy certificate dully issued by Authority. (5) Supervision in the manner prescribed shall be conducted with intimation to the Authority. (6) Mandatory provision of rainwater harvesting is to be provided. (7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated: Form-22 ( See rule 76) (For above G+2) Form for specification of proposed building (1) The purpose (Residence, Office, Restaurant, Hotel, Dharamshala, School, Hostel, Cinema, Shop, Factory. Others) for which it is intended to be used................................................................................................................ .................................................................................................... (2) Details of Area on respective floor are given below Floor Existing (sq. mt.) Proposed (sq. mt.) Total (sq. mt.) 1 Basement 2 Ground 3 Mezzanine 4 First floor 5 Second floor 6 Third 7 8 9 10 Service floor (if any)\n(3) The plot is free from all encumbrances (owner responsibility). (4) Building shall not be occupied before getting occupancy certificate dully issued by Authority. (5) Supervision in the manner prescribed shall be conducted with intimation to the Authority. (6) Mandatory provision of rainwater harvesting is to be provided. (7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated: Form-22 ( See rule 76) (For above G+2) Form for specification of proposed building (1) The purpose (Residence, Office, Restaurant, Hotel, Dharamshala, School, Hostel, Cinema, Shop, Factory. Others) for which it is intended to be used................................................................................................................ .................................................................................................... (2) Details of Area on respective floor are given below\n(4) Building shall not be occupied before getting occupancy certificate dully issued by Authority. (5) Supervision in the manner prescribed shall be conducted with intimation to the Authority. (6) Mandatory provision of rainwater harvesting is to be provided. (7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated: Form-22 ( See rule 76) (For above G+2) Form for specification of proposed building (1) The purpose (Residence, Office, Restaurant, Hotel, Dharamshala, School, Hostel, Cinema, Shop, Factory. Others) for which it is intended to be used................................................................................................................ ....................................................................................................\n(5) Supervision in the manner prescribed shall be conducted with intimation to the Authority. (6) Mandatory provision of rainwater harvesting is to be provided. (7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated: Form-22 ( See rule 76) (For above G+2) Form for specification of proposed building (1) The purpose (Residence, Office, Restaurant, Hotel, Dharamshala, School, Hostel, Cinema, Shop, Factory. Others) for which it is intended to be used................................................................................................................\n(6) Mandatory provision of rainwater harvesting is to be provided. (7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated: Form-22 ( See rule 76) (For above G+2) Form for specification of proposed building (1) The purpose (Residence, Office, Restaurant, Hotel, Dharamshala, School, Hostel,\n(7) Special earthquake resistance measure (Like shear wall/breeching etc.) has been taken to make stilt parking as an earthquake resistance structure. ........................................ ....................................... Signature of the owners: Signature of registered Architect/Engineer/supervisor Name of owner(s): Registration no. of the Architect/Engineer/supervisor: Address of the owner(s): Address of the Architect/Engineer/supervisor: Dated: Dated:\n........................................\n.......................................\nSignature of the owners:\nSignature of registered Architect/Engineer/supervisor\nName of owner(s):\nRegistration no. of the Architect/Engineer/supervisor:\nAddress of the owner(s):\nAddress of the Architect/Engineer/supervisor:\nDated:\nDated:\nForm-22\nForm-22\n( See rule 76)\n( See rule 76)\n(For above G+2)\nForm for specification of proposed building\nForm for specification of proposed building\nFloor\nExisting (sq. mt.)\nProposed (sq. mt.)\nTotal (sq. mt.)\n1\nBasement\n2\nGround\n3\nMezzanine\n4\nFirst floor\n5\nSecond floor\n6\nThird\n7\n8\n9\n10\nService floor (if any)\n(a) Approximate number of inhabitants proposed to be accommodated ................\n(b) The number of Latrine. Urinals, Kitchens. Baths to be provided ....................\n(c) The source of water to be used in the construction ....................................\n(d) Distance from public sewer (if any) ......................................................\n(e) The materials to be used in construction walls/ Columns/ Foundations/ Roof/ Floors......................................................................................\nSignature of registered Architect/Engineer/ supervisor\nName .........................................................\nRegistration No. ............................................\nAddress ......................................................\n.........................................\n.............................................\nSignature of the owners:\nSignature of registered Architect/Engineer/supervisor\nName (in block letters):\nRegistration no. of the Architect/Engineer/supervisor:\nName (in block letters):\nAddress of the owner(s): Address of the\n\t\t\t\tArchitect/Engineer/supervisor:\nDated:\nDated:\nForm-23\nForm-23\n(see rule 107)\n(see rule 107)\nAffidavit-cum Undertaking\nAffidavit-cum Undertaking\n(Title of the project)\n(Name of the owner/Developer/Builder)\nOr\nDeponent\nForm 24\nForm 24\n( see rule 24)\n( see rule 24)\nCompletion-Cum-Occupancy Certificate\nCompletion-Cum-Occupancy Certificate",
"footnote": "",
"is_definition": false,
"sort_order": 132
},
{
"number": "1",
"title": "1. Location of Building",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 133
},
{
"number": "2",
"title": "2. Details of completed work floor wise",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 134
},
{
"number": "3",
"title": "3. Enclosed : As-built plan",
"chapter": null,
"content": "Note: NOC issued from the fire services to be renewed each year, failing which the occupancy certificate shall lapse.\nForm 25\nForm 25\n( see rule 24)\n( see rule 24)\nForm of Rejection or Compliance in Respect of Occupancy Certificate\nForm of Rejection or Compliance in Respect of Occupancy Certificate\n(1.) With reference to your letter dated ............................................\n(2.) With reference to your Notice of Completion dated .........................\n(3.) In continuation to this office letter of even no. .............................dated.............\n(a) Submission of the following document :\n(1)\n(2)\n(3)\n(4)\n(5)\n(b) Rectification of the following deviations :\n(1)\n(2)\n(3)\n(4)\n(5)\n(c) The following items can be regularized on payment of compounding fee noted against each :\nSl no\nItem\nRate of Compounding fee\nAmount of Compounding fee in Rs.\nTotal Compounding fee Rs.\n..................................",
"footnote": "",
"is_definition": false,
"sort_order": 135
}
],
"metadata": {
"Act ID": "Last Updated 10th February, 2020 [ass012]",
"Act Number": "Published vide Notification No. UDD(T)42/2008/vol-2/116, dated 20th February, 2014",
"Enactment Date": "",
"Act Year": "2014",
"Short Title": "Assam Notified Urban Areas (Other than Guwahati) Building Rules, 2014",
"Type": "STATE",
"Location": "Assam"
},
"updated_at": "2026-09-29 21:55:19"
}