Trunked Mechanical Ventilation System
1.
2.
3.
4.
5.
6.
7.
8.
Category
Category
Space
Space
Fresh
air changes per hour
Fresh
air changes per hour
Volume
of fresh air, in cubic metres per minute, for each person likely
to use the room at any one time
Volume
of fresh air, in cubic metres per minute, for each person likely
to use the room at any one time
1
2
3
4
A.
A.
Room other than
rooms in category (c) in deck houses above the upper or shelter
deck :-
(1)outside
rooms (other than rooms adjoining machinery casing)
(2) inside rooms
and rooms adjoining machinery casing.
10
15
[1.42
cubic meters per minute]
[1.42
cubic meters per minute]
B
B
Rooms (other than
rooms in Category C in side-to-side superstructures above the
upper or shelter deck :-)
(1)
outside rooms (other than rooms adjoining machinery casing).
(2) inside rooms
and rooms adjoining machinery casing.
12
15
[1.42
cubic meters per minute]
[1.42
cubic meters per minute]
C
C
Mess rooms,
smoking rooms and recreation rooms (in each case above the upper
or shelter decks :-
(1)
not adjoining machinery casing
(2) adjoining
machinery casing
15
18
[0.71
cubic meter per minute]
[0.71
cubic meter per minute]
D
D
Passageways
adjoining machinery casings
4
E
E
Rooms in between
decks (including shelter"tween decks) of ships propelled by
internal combustion machinery
(1)
Rooms clear of machinery casing.
(2)
Rooms abreast of but not adjoining machinery casing.
(3)
Rooms adjoining machinery casing (other than mess rooms, smoking
rooms and recreation rooms).
(4) Mess rooms,
smoking rooms, and recreation rooms (in each case adjoining
machinery casing).
12
12
15
18
[1.42
cubic meters per minute]
[1.42
cubic meters per minute]
[1.70
cubic meters per minute]
[1.71
cubic meters per minute]
F
F
Rooms in between
decks (including shelter tween decks) of steamships :-
(1)
Rooms clear of machinery casing
(2)
Rooms abreast of, but not adjoining machinery casing.
(3)
Rooms immediately above machinery casing or abreast of and
adjoining machinery casing (other than mess rooms, smoking rooms
and recreation rooms)
(4) Mess room,
smoking rooms and recreation rooms (in each case adjoining
machinery casing)
12
15
18
18
[1.42
cubic meters per minute]
[1.70
cubic meters per minute]
[1.70
cubic meters per minute]
[0.85
cubic meters per minute]
(a)
whatever the number of persons likely to use the room at one
time, the total volume of fresh air per minute shall not be
required to be such as would result in more than 20 fresh air
changes per hour.
(b) Whatever the
number of persons likely to use the room at any one time, the
total volume of fresh air per minute shall not be required to be
such as would result in more than 24 fresh air changes per hour.
Category
Category
Space
Space
Fresh
air change per hour
Fresh
air change per hour
Supply
Exhaust
Supply
Exhaust
Supply
Exhaust
Supply
Exhaust
1
2
3
4
G
G
Galleys
20(c)(d)
40(d)
H
H
Sanitary
accommodation, drying rooms and pantries
10
-
J
J
Wards
in permanent hospitals
12
or
such greater number as would result in the supply of not less
than 1.42 cubic meters of fresh air per minute for each bed in
the room.
-
K
K
Dry
provision store rooms.
Not
less than 10(e) and not more than 20.
-
(c) 15, if at least two sides of the galley are exposed to the weather.
(d) The Central Government may exempt any ship from these requirements to the extent that it is satisfied that compliance therewith is unnecessary by reason of the insulation of the equipment in the galley, or by reason of the size of the galley.
(e)Subject to the provision of rule 29 (4).
Second Schedule
Second Schedule
[See rules 7(2) and 8(3)]
Deck Sheathings
(a) Foothold.
(b) Thermal Insulation.
(i) If the material covers a deck exposed to the weather it shall provide thermal insulation not less than that provided by a wooden deck 5.8 centimetres thick.
(ii) If the material covers any other deck, it shall provide a warm and comfortable surface.
(c) Fire Resistance.
(d) Water Absorption.
(e) Adhesion.
(f) Non-corrosion.
(g) Danger to Persons.
(h) Resistance to Wear and Weather.
2.
3.
Third Schedule
[See rule 7(2)]
Insulating Material for the Underside of Decks
(a) Thermal Insulation.
(b) Fire Resistance.
(c) Adhesion.
(d) Non-corrosion.
Fourth Schedule
Fourth Schedule
(See rule 15]
Markings
Part I
Part I
Part II
Part II
Marking for Spaces other than Sleeping Rooms