{
    "act_title": "The Merchant Shipping (Crew Accommodation) Rules, 1960",
    "act_slug": "the-merchant-shipping-crew-accommodation-rules-1960",
    "section_label": "Section",
    "section": {
        "number": "39",
        "title": "39. Penalties.",
        "chapter": null,
        "content": "First Schedule\nFirst Schedule\n[See rules 2(1) (m) and 12 (3)]\nTrunked Mechanical Ventilation System\n1.\n2.\n3.\n4.\n5.\n6.\n7.\n8.\nCategory\nCategory\nSpace\nSpace\nFresh\n air changes per hour\nFresh\n air changes per hour\nVolume\n of fresh air, in cubic metres per minute, for each person likely\n to use the room at any one time\nVolume\n of fresh air, in cubic metres per minute, for each person likely\n to use the room at any one time\n1\n2\n3\n4\nA.\nA.\nRoom other than\n rooms in category (c) in deck houses above the upper or shelter\n deck :-\n(1)outside\n rooms (other than rooms adjoining machinery casing)\n(2) inside rooms\n and rooms adjoining machinery casing.\n10\n15\n[1.42\n cubic meters per minute]\n[1.42\n cubic meters per minute]\nB\nB\nRooms (other than\n rooms in Category C in side-to-side superstructures above the\n upper or shelter deck :-)\n(1)\n outside rooms (other than rooms adjoining machinery casing).\n(2) inside rooms\n and rooms adjoining machinery casing.\n12\n15\n[1.42\n cubic meters per minute]\n[1.42\n cubic meters per minute]\nC\nC\nMess rooms,\n smoking rooms and recreation rooms (in each case above the upper\n or shelter decks :-\n(1)\n not adjoining machinery casing\n(2) adjoining\n machinery casing\n15\n18\n[0.71\n cubic meter per minute]\n[0.71\n cubic meter per minute]\nD\nD\nPassageways\n adjoining machinery casings\n4\nE\nE\nRooms in between\n decks (including shelter\"tween decks) of ships propelled by\n internal combustion machinery\n(1)\n Rooms clear of machinery casing.\n(2)\n Rooms abreast of but not adjoining machinery casing.\n(3)\n Rooms adjoining machinery casing (other than mess rooms, smoking\n rooms and recreation rooms).\n(4) Mess rooms,\n smoking rooms, and recreation rooms (in each case adjoining\n machinery casing).\n12\n12\n15\n18\n[1.42\n cubic meters per minute]\n[1.42\n cubic meters per minute]\n[1.70\n cubic meters per minute]\n[1.71\n cubic meters per minute]\nF\nF\nRooms in between\n decks (including shelter tween decks) of steamships :-\n(1)\n Rooms clear of machinery casing\n(2)\n Rooms abreast of, but not adjoining machinery casing.\n(3)\n Rooms immediately above machinery casing or abreast of and\n adjoining machinery casing (other than mess rooms, smoking rooms\n and recreation rooms)\n(4) Mess room,\n smoking rooms and recreation rooms (in each case adjoining\n machinery casing)\n12\n15\n18\n18\n[1.42\n cubic meters per minute]\n[1.70\n cubic meters per minute]\n[1.70\n cubic meters per minute]\n[0.85\n cubic meters per minute]\n(a)\n whatever the number of persons likely to use the room at one\n time, the total volume of fresh air per minute shall not be\n required to be such as would result in more than 20 fresh air\n changes per hour.\n(b) Whatever the\n number of persons likely to use the room at any one time, the\n total volume of fresh air per minute shall not be required to be\n such as would result in more than 24 fresh air changes per hour.\nCategory\nCategory\nSpace\nSpace\nFresh\n air change per hour\nFresh\n air change per hour\nSupply\n Exhaust\nSupply\n Exhaust\nSupply\n Exhaust\nSupply\n Exhaust\n1\n2\n3\n4\nG\nG\nGalleys\n20(c)(d)\n40(d)\nH\nH\nSanitary\n accommodation, drying rooms and pantries\n10\n-\nJ\nJ\nWards\n in permanent hospitals\n12\nor\n such greater number as would result in the supply of not less\n than 1.42 cubic meters of fresh air per minute for each bed in\n the room.\n-\nK\nK\nDry\n provision store rooms.\nNot\n less than 10(e) and not more than 20.\n-\n(c) 15, if at least two sides of the galley are exposed to the weather.\n(d) The Central Government may exempt any ship from these requirements to the extent that it is satisfied that compliance therewith is unnecessary by reason of the insulation of the equipment in the galley, or by reason of the size of the galley.\n(e)Subject to the provision of rule 29 (4).\nSecond Schedule\nSecond Schedule\n[See rules 7(2) and 8(3)]\nDeck Sheathings\n(a) Foothold.\n(b) Thermal Insulation.\n(i) If the material covers a deck exposed to the weather it shall provide thermal insulation not less than that provided by a wooden deck 5.8 centimetres thick.\n(ii) If the material covers any other deck, it shall provide a warm and comfortable surface.\n(c) Fire Resistance.\n(d) Water Absorption.\n(e) Adhesion.\n(f) Non-corrosion.\n(g) Danger to Persons.\n(h) Resistance to Wear and Weather.\n2.\n3.\nThird Schedule\n[See rule 7(2)]\nInsulating Material for the Underside of Decks\n(a) Thermal Insulation.\n(b) Fire Resistance.\n(c) Adhesion.\n(d) Non-corrosion.\nFourth Schedule\nFourth Schedule\n(See rule 15]\nMarkings\nPart I\nPart I\nPart II\nPart II\nMarking for Spaces other than Sleeping Rooms",
        "footnote": "",
        "is_definition": false,
        "sort_order": 38
    },
    "prev_section": "38",
    "next_section": null
}