12. Ventilation.

(b) The sectional area of every part of the inlet and exhaust system (other than a par serving a drying room or locker) shall be at least [38.71 square centimetre] for each person for whose use at any one time the space is appropriated and shall not be less than [122.58 square centimetres] in all at any point in the system. The effective area of the inlet and exhaust system serving each space shall be capable of being adjusted from fully open down to a minimum of the [19.35 square centimetres] for each person likely to use the space at any time.
(a) maintain the air at a satisfactory temperature and relative humidity as compared to outside air conditions;
(b)ensure a sufficiency of air charges in all air conditioned spaces;and
(c) take into account particular characteristics of operations at sea so as to avoid producing objectionable noises or vibrations.]