← Back to Directory

The Madras Port Petroleum Rules, 1963

The Madras Port Petroleum Rules, 1963

Raw JSON API

Sections

1. Short title, extent and commencement.

Section 1

2. Application of Petroleum Rules, 1937, not barred.

Section 2

3. Definitions.

Section 3

4. Notice of arrival of 'Petroleum'.

Section 4

5. Vessels carrying Petroleum in bulk.

Section 5

6. Landing of Petroleum in bulk.

Section 6

7. Vessels discharging Petroleum in bulk.

Section 7

8. Conditions of landing of Petroleum in bulk.

Section 8

9. Accident Fire prevention.

Section 9

10. Cased Petroleum, i.e., Petroleum not in bulk.

Section 10

11. Landing of Non-dangerous cased Petroleum.

Section 11

12. Sailing vessels.

Section 12

13. Landing of cased dangerous Petroleum.

Section 13

14. Cased Dangerous Petroleum in excess of 20 tons or 6,000 gallons.

Section 14

15. Bunkering.

Section 15

16. Enforcement and Penalties.

Section 16

1. Arrange for the tanker to stop pumping and to shut down all tanker discharge valves.

Section 1

2. Notify the Port Fire Service-Telephone No. 30161, Extension 268.

Section 2

3. Notify the Booster Pumphouse.

Section 3

4. Notify the Terminal receiving petroleum, if necessary.

Section 4

1. Speaking-tube communicating between the pump room and the engine room shall, at all times, be left closed with the metal cap provided.

Section 1

2. The doors and windows of the pumphouse shall always be left closed.

Section 2

3. Breakages to the door and window-panes and damage to ventilator shutters shall promptly be reported to the Workshop Foreman for urgent repairs.

Section 3

4. The refuse-bin provided in the pit shall always be kept reasonably clean of oil waste and other waste matter.

Section 4

1. Stop or arrange to stop pumping.

Section 1

2. Actuate the warning device to warn the supervisor on North Groyne and to Engineer at tanker pump.

Section 2

3. Notify West Fire Station by telephone.

Section 3

4. Hoist warning signal (Red burgee during day and red light during night) on the flag staff on top of the pumphouse.

Section 4

1. Vans of the pumphouse driven by the quickest means.

Section 1

2. Inform West Fire Station of the occurrence (In case of leak, information may be given over telephone, in case of fire, actuate the nearest fire alarm box and follow up with a telephonic message.)

Section 2

3. Report the occurrence to 'M' Division Police Station.

Section 3

4. Cordon off the area as best as possible pending arrival of police party and see that no naked lights are brought or caused to be within 300 feet of the point of occurrence. (For the purpose of this order, locos internal combustion engines, hurricanes and pressurised lanterns, railways signal lamps, all types of cycle lamps, ordinary electric hand torches, etc., are to be considered as 'naked lights'.)

Section 4

5. Pending arrival of Fire Service, take such other measures as may be considered expedient to prevent outbreak of fire or to keep in check or extinguish the fire if one has already started.

Section 5

1. The, mazdoor who notices the leak/fire, shall rush either to the Pumphouse near No. 1 Gate or to the Oil Companies' bunk on the North Groyne (whichever of the two places is nearer or more readily reached from the location of the leak/fire) and shall notify the occurrence to the Pumphouse driver or the Oil.Company's staff present at the North Groyne. On his way to the pumphouse or North Groye, he shall alert the other mazdoors, by shouting out the information to them.

Section 1

2. A second mazdoor, i.e., the one nearest to the location of the leak/ fire shall rush to contact any responsible member of the Port Trust Section or Railway staff who may be available nearest to location of the leak/ fire, and shall notify him of the occurrence.

Section 2

3. The remaining two Mazdoors shall rush to the location of the leak/fire and shall take such action as they can, to prevent a fire or to keep the fire under control. In the case of a leak, such Mazdoors shall endeavour to cordon off the area, as best as they can and shall ward-off locos and other sources of naked light, from the vicinity of the leak. In the event of a fire, they shall endeavour to keep the fire under check; by using earth and sand or the foamengine stationed near the Pumph

Section 3

1. Turn out one unit, under the charge of the seniormost rank of the Fire Service then present at the station.

Section 1

2. Notify the Fire Officer and Assistant Satefy Officer, and also notify the Harbour Master of the leak/fire.

Section 2

3. Instruct the Hydraulic Powerhouse Driver to start the Fire Service pump and to maintain a working pressure of about 100 lbs.p.s.i. at the pump gauge.

Section 3

1. Highly inflammable, even a spark may be sufficient to cause ignition.

Section 1

1. Naked or non-safety lights should not be allowed within a radius of atleast 100 ft. of any place where such liquids are handled/st.

Section 1

2. Vapour forms explosive mixture with air ignition of such mixture by a spark or flame may cause a shattering explosion.

Section 2

2. The electrical fittings (switches for light and fans, lamp holders, etc.) within the premises used for storage of such liquids should be of the gasproof safety pattern and the wiring should be run in properly earthed metal conduits.

Section 2

3. The vapour, which is generally heavier than air, may travel considerable distances (as and when blown by a draught of air) and may then ignite by contact with flame or spark.

Section 3

3. Every source of sparking should be avoided within a. radius of 100 ft. of any place where vapour of such liquids may be present.

Section 3

4. Vapours of most such liquids are injurious if inhaled for any length of time.

Section 4

4. The drums/ containers of such liquids should not be dropped, bumped, rolled or roughly handled.

Section 4

5. Every possible precaution should be taken to prevent leaks in containers/drums of such liquids.

Section 5

6. Leaks in such drums/containers should be notified to the Fire Service, immediately on being noticed.

Section 6