← Back to Directory
The Gas Cylinders Rules, 2004
The Gas Cylinders Rules, 2004
Sections
CHAPTER I
CHAPTER I
Section 11. Short title and commencement
Section 12. Definitions
Section 2
CHAPTER II
CHAPTER II
Section 43. Filling, possession, import and transport of cylinders
Section 34. Valves
Section 45. Safety relief devices
Section 56. Marking on cylinders
Section 67. Markings on valve
Section 78. Identification colours
Section 89. Labelling of cylinders
Section 910. Restriction on delivery or despatch of cylinders
Section 1011. Repairing of seamless gas cylinders during use
Section 1112. Repairing of welded or brazed cylinders
Section 1213. Prohibition of employment of children and intoxicated persons
Section 1314. Prohibition of smoking, fires, lights and dangerous substances
Section 1415. General precautions
Section 1516. Special precautions against accidents
Section 1617. Competent person to be incharge of operations
Section 1718. Handling and use
Section 1819. Restrictions on filling
Section 1920. Loading, unloading and transport of cylinders
Section 2021. Storage of cylinders
Section 2122. Electrical installations
Section 2223. Purity of gas
Section 2324. Cylinder subjected to the action of fire
Section 2425. Ownership of cylinder
Section 2526. Re-testing of cylinder
Section 2627. Owner's record
Section 2728. Conversion of cylinders
Section 28
CHAPTER III
CHAPTER III
Section 3129. License for import of gas cylinders
Section 2930. Declaration by the master of ship or ship's agent
Section 3031. Production of license for import
Section 3132. Permission of the Commissioner of Customs
Section 3233. Importation by land
Section 3334. Importation by air
Section 34
CHAPTER IV
CHAPTER IV
Section 3835. Periodicity of examination and testing of cylinders
Section 3536. Condemning of cylinders
Section 36
CHAPTER V
CHAPTER V
Section 4137. Additional requirements for dissolved acetylene gas cylinders
Section 3738. Restriction on filling of dissolved acetylene in cylinders
Section 3839. Examination of dissolved acetylene cylinders before filling
Section 3940. License for compression of acetylene
Section 4041. Record of dissolved acetylene cylinders
Section 4142. Labelling of dissolved acetylene cylinders
Section 42
CHAPTER VI
CHAPTER VI
Section 4843. License for filling and possession
Section 4344. No license needed for filling and possession in certain cases
Section 4445. Restriction on filling
Section 4546. Working pressure and filling ratios
Section 4647. Prior approval of specifications and plans of premises proposed to be licensed
Section 4748. No Objection Certificate
Section 4849. Application for license
Section 4950. Grant of license
Section 5051. Period for which licenses may be granted or renewed
Section 5152. Particulars of license
Section 5253. Prior approval necessary for alteration in the licensed premises
Section 5354. Amendment of license
Section 5455. Renewal of license
Section 5556. Refusal of license
Section 5657. Suspension and cancellation of license
Section 5758. Procedure on expiration, suspension or cancellation of license
Section 5859. Appeal
Section 5960. Procedure on death or disability of licensee
Section 6061. Loss of license
Section 6162. Production of license on demand
Section 6263. Procedure on reports of infringement
Section 6364. Executive control over authorities
Section 6465. License fee and other than license fee
Section 65
CHAPTER VII
CHAPTER VII
Section 7266. Power to exempt
Section 66
CHAPTER VIII
CHAPTER VIII
Section 7467. Notice of accidents
Section 6768. Inquiry into accidents
Section 6869. Inquiry into more serious accidents
Section 69
CHAPTER IX
CHAPTER IX
Section 7870. Dangerous practices
Section 7071. Powers of inspection, search, seizure, detention and removal
Section 7172. Protection of action taken in good faith
Section 7273. Repeal and savings
Section 731. Name in which license required** .............................................................. Applicant's calling .............................................................. Applicant's full postal address .............................................................. 2. Situation of the premises where compressed gas is to be stored /filled: State .............................................................. District .............................................................. Town or
Section 1
the-gas-cylinders-rules-2004.json
•
83 Sections
•
India (Central)
{
"id": 11869,
"slug": "the-gas-cylinders-rules-2004",
"title": "The Gas Cylinders Rules, 2004",
"short_title": "The Gas Cylinders Rules, 2004",
"act_number": "Published vide G.S.R. 627(E), dated 21.9.2004, pub",
"act_year": 2004,
"act_type": "CENTRAL",
"location": "India (Central)",
"law_status": "unknown",
"enactment_date": null,
"description": "The Gas Cylinders Rules, 2004",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "CHAPTER I",
"chapter": "CHAPTER I",
"content": "Preliminary",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "1",
"title": "1. Short title and commencement",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 1
},
{
"number": "2",
"title": "2. Definitions",
"chapter": null,
"content": "(i) \"Act\" means the Explosives Act, 1884 (4 of 1884);\n(ii) \"Auto LPG\" means liquefied petroleum gas meant for automotive fuel conforming to specification IS: 14861;\n(iii) \"Chief Controller\" means the Chief Controller of Explosives, Government of India;\n(iv) \"composite cylinder\" means a cylinder made of resin impregnated continuous filament wound over a metallic or a non-metallic liner. Composite cylinders using non-metallic liners are referred to as all-composite cylinders;\n(v) \"compressed gas\" means any permanent gas, liquefiable gas or gas dissolved in liquid under pressure or gas mixture which in a closed gas cylinder exercises a pressure either exceeding 2.5 kgf/cm2 abs (1.5 kgf/cm2 gauge) at + 150C or a pressure exceeding 3kgf/cm2 abs (2kgf/cm2 gauge) at + 500C or both;\n(vi) \"Conservator\" in relation to a port includes any person acting under the authority of the officer or body of person appointed to be Conservator of that Port under section 7 of the Indian Ports Act, 1908 (15 of 1908);\n(vii) \"Controller\" includes the Joint Chief Controller of Explosives, the Deputy Chief Controller of Explosives, the Controller of Explosives and the Deputy Controller of Explosives;\n(viii) \"Compressed Natural Gas (CNG)\" means mixtures of hydrocarbon gases and vapours, consisting mainly of Methane words [or suitable mixtures of Hydrogen and Methane] in gaseous form, which has been compressed for use as automotive fuel;\n(ix) \"CNG mother station\" means CNG facilities connected with natural gas pipeline and having a compressor meant primarily to fill mobile cascades of daughter station. Such stations may also have stationary cascade for dispensing CNG to vehicles;\n(x) \"CNG online station\" means CNG facilities connected with natural gas pipeline and having a compressor primarily to fill stationary cascades for dispensing CNG to vehicles;\n(xi) \"CNG daughter station\" means CNG facilities not connected to natural gas pipeline. Such CNG dispensing station receives CNG through mobile cascade;\n(xii) \"critical temperature\" means the temperature above which gas cannot be liquefied by the application of pressure alone;\n(xiii) \"dissolved acetylene cylinder\" means a cylinder having a valve and with or without safety devices, containing a porous mass, a solvent for the storage of dissolved acetylene and at least sufficient acetylene to saturate the solvent at atmospheric pressure and at a temperature of + 150C.\n(xiv) \"dissolved gas\" means a gas which under pressure is dissolved in a fluid solvent appropriate to the particular gas as, for example, acetylene in acetone or ammonia in water;\n(xv) \"District Authority\" means-\n(a) a Commissioner of Police or Deputy Commissioner of Police in any town having a Commissioner of Police; and\n(b) in any other place, the District Magistrate;\n(xvi) \"District Magistrate\" includes an Additional District Magistrate, and in the States of Punjab and Haryana and in the Karaikal, Mahe and Yanam areas of the Union territory of Pondicherry, also includes a Sub-Divisional Magistrate;\n(xvii) \"filling pressure\" means the maximum permissible gauge pressure, converted to + 150C, at which a gas cylinder for permanent gas or gas dissolved under pressure can be filled;\n(xviii) \"filling ratio\" means the ratio of the weight of a liquefiable gas introduced in the cylinder to the weight of the water the cylinders will hold at 150C;\n(xix) \"flammable gas\" means any gas which, if either a mixture of 13 per cent or less (by volume) with air forms a flammable mixture or the flammability range with air is greater than 12 per cent regardless of the lower limit and these limits shall be determined at atmospheric temperature and pressure.\n(xx) \"Form\" means a Form set forth in Schedule V;\n(xxi) \"Gas Cylinder\" or \"Cylinder\" means any closed metal container having a volume exceeding 500 ml but not exceeding 1000 litres intended for the storage and transport of compressed gas, including any liquefied petroleum gas (LPG) container/compressed natural gas (CNG) cylinder fitted to a motor vehicle as its fuel tank but not including any other such container fitted to a special transport or under-carriage and includes a composite cylinder, however, the water capacity of cylinders used for storage of CNG, nitrogen, compressed air, etc., may exceed 1000 litres up to 2500 litres provided the diameter of such cylinder does not exceed 60 cm;\n(xxii) \"high pressure liquefiable gas\" means a liquefiable gas having a critical temperature between -100C and + 700C;\n(xxiii) \"hydrostatic stretch test\" means subjecting the cylinder to a hydrostatic pressure equal to the test pressure of the cylinder and recording the permanent stretch undergone by the cylinder;\n(xxiv) \"hydrostatic test\" means the test to which a cylinder is subjected to a hydrostatic pressure equal to the test pressure of the cylinder;\n(xxv) \"import\" means bringing into India by land, sea or air;\n(xxvi) \"inert gas\" means a gas which is resistant to chemical action under normally encountered conditions;\n(xxvii) \"Inspecting Authority\" means a person having qualifications and wide experience in the field of design, manufacture and testing of gas cylinders and recognised by the Chief Controller as authority for inspection and certification of gas cylinder;\n(xxviii) \"installation\" means any premises wherein any place has been specially prepared for the manufacture (filling) or storage of compressed gas cylinders;\n(xxix) \"liquefiable gas\" means a gas that may be liquefied by pressure at -100C but will be completely vaporised when in equilibrium with normal atmospheric pressure (760 mm. Hg) at 17.50C which value shall be increased to 300C for toxic gases;\n(xxx) \"liquefied petroleum gas\" means any material, which comprises predominantly of any of the following hydrocarbons or mixture of them with vapour pressure not exceeding 16.87 kg/cm2 (gauge) at 650C:-\n(xxxi) \"low pressure liquefiable gas\" means a liquefiable gas having critical temperature higher than +700C;\n(xxxii) \"manufacture of gas\" means filling of a cylinder with any compressed gas and also includes transfer of compressed gas from one cylinder to any other cylinder;\n(xxxiii) \"oxidizing gas\" means a gas which gives up oxygen readily or removes hydrogen from a compound or attracts negative electrons;\n(xxxiv) \"permanent gas\" means a gas whose critical temperature is below -100C that is to say a gas which cannot be liquefied under any pressure at a temperature above -100C;\n(xxxv) \"poisonous (toxic) gas\" a gas which has a maximum allowable concentration in air for human respiration not exceeding 100 mg/m3 at 150C and 1 kgf/cm2 absolute pressure;\n(xxxvi) \"Schedule\" means the Schedule annexed to these rules;\n(xxxvii) \"tare weight\" in relation to-\n(xxxviii) \"test pressure\" means the internal pressure required for the hydrostatic test or hydrostatic stretch test of the cylinder, as follows:-\n(1) For permanent and high pressure liquefiable gases, it should be calculated from the following:\nPh =\n200.t. Re\n1.25 (Do-t)\n(xxxix) \"transport\" means the moving of a cylinder filled with any compressed gas from one place to another;\n(xxxx) \"water capacity\" means the volume of water in litres, a cylinder will hold at 150C;\n(xxxxi) \"working pressure for low pressure liquefiable gas\" means the saturated vapour pressure at 650C\"> Explanation .-The values of saturated vapour pressure of different gases are specified in IS: 3710;\n(xxxxii) \"working pressure for permanent gas\" means the internal pressure of the gas in the cylinder at a temperature of 150C;\n(xxxxiii) \"yield strength\" means the stress corresponding to a permanent strain of 0.2 per cent of the original gauge length in a tensile test. For practical purpose it may be taken as a stress at which elongation first occurs in the test piece without the increase of load in a tensile test.",
"footnote": "",
"is_definition": true,
"sort_order": 2
},
{
"number": "4",
"title": "CHAPTER II",
"chapter": "CHAPTER II",
"content": "General Provisions",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "3",
"title": "3. Filling, possession, import and transport of cylinders",
"chapter": null,
"content": "(a) such cylinder and its valve have been constructed to a type and standard specified in Schedule I as amended from time to time by an order issued by the Chief Controller;\n(b) the test and inspection certificates issued by the Inspecting Authority in respect of cylinder and its valve are made available to the Chief Controller and prior approval of the said authority is obtained.\n(i) total number and serial numbers of the cylinders;\n(ii) name and address of the manufacturers of the cylinders;\n(iii) specification of the cylinders and the valves;\n(iv) previous approval, if any;\n(v) the test and inspection certificates in respect of the cylinders;\n(vi) the test and inspection certificates pertaining to the valves fitted/to be fitted to the cylinders;\n(vii) scrutiny fee as specified in Schedule V.\n(b) For any subsequent changes in the design drawing, a fresh approval shall be obtained.\n(a) the cylinder has passed the hydrostatic test or hydrostatic stretch test, as the case may be, within the period specified in these rules and the pressure applied during the test shall be the test pressure marked on the cylinder;\n(b) the cylinder is not filled with-\n(i) any liquefiable gas in excess of the filling ratio specified in IS: 3710 for low pressure liquefiable gases and IS: 8866 for high pressure liquefiable gases;\n(ii) any permanent gas at a pressure in excess of the pressure for which the cylinder is designed;\n(c) a separate record of the cylinder tested and filled is maintained at the filling station;\n(d) the filled cylinders are removed from the filling station and shipped off as expeditiously as possible.",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "4",
"title": "4. Valves",
"chapter": null,
"content": "(a) in respect of industrial gas cylinders, IS: 3224;\n(b) in respect of medical gas cylinders, IS: 3745;\n(c) in respect of cylinders used with breathing apparatus, IS: 7302 as amended from time to time;\n(d) in respect of cylinders used for filling liquefied petroleum gas, IS: 8776 for cylinders of water capacity not exceeding 5 litres and, IS: 8737 for cylinders of water capacity exceeding 5 litres;\n(e) in respect of auto LPG containers, IS: 15100;\n(f) in respect of small Refrigerant cylinders, IS: 12300:",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "5",
"title": "5. Safety relief devices",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "6",
"title": "6. Marking on cylinders",
"chapter": null,
"content": "(a) Every gas cylinder shall be clearly and permanently marked in accordance with following conditions by stamping, engraving or similar processes:\n(i) on the shoulder of the cylinder which shall be reinforced by forging or other means, or\n(ii) on such a part which is inseparably bound with the cylinder and which is not or only negligibly affected by the stresses due to the gas pressure within it.\n(b) The name plate shall not be affixed to the cylinder by soldering if there is a risk of corrosion or embrittlement.\n(c) In conjunction with the original marking, space shall be provided for stamping the test date obtained at the periodic inspection.\n(d) Markings shall be so carried out and the letters and numerals used shall be of such shape and size that the marking is clear and easily readable and does not give place for misreading.\n(a) Every cylinder shall be marked with the following markings, namely:-\n(i) manufacturer's, owner's and inspector's marking and rotation number (these markings shall be registered with the Chief Controller);\n(ii) specification to which the cylinder has been made;\n(iii) a symbol to indicate the nature of heat treatment given to the cylinder during manufacture or after repairs;\n(iv) the date of the last hydrostatic test or hydrostatic stretch test, as the case may be, with the code mark of recognised testing station where the test was carried out and the code mark shall be registered with the Chief Controller. In the case of liquefied petroleum gas cylinders, the quarter and the year of test shall be given as an additional marking in a neck or on a shoulder plate;\n(v) working pressure and test pressure;\n(vi) tare weight-\n(vii) water capacity.\n(b) All the markings, except the manufacturer's markings, which may be on the base, shall be stamped on the neck end of the cylinder. However, seamless cylinders having no foot ring or skirt shall be stamped with the manufacturer's marking on the neck end of the cylinder.",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "7",
"title": "7. Markings on valve",
"chapter": null,
"content": "(i) the specification of the valves;\n(ii) year and month or quarter of manufacture;\n(iii) manufacturer's symbol;\n(iv) working pressure;\n(v) the name or chemical symbol of the gas for which the valve is to be used;\n(vi) the type of screw threads on the outlet, in case of left handed as (L.H.);\n(vii) Inspector's stamp;\n(viii) where dip tubes are provided, special indications shall be given by a clear and durable marking on the valve or on a badge fixed between the valve and the cylinder and the total length in millimetre of the tube shall also be indicated.",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "8",
"title": "8. Identification colours",
"chapter": null,
"content": "Name of the gas contained in the cylinder Colour of the cylinder shell Colour of band at neck end of cylinder 1 2 3 Non-flammable and non-toxic White Non-flammable but toxic White Yellow (IS:5 Shade No. 356) Flammable but non-toxic other than the LPG White Red (IS: 5 Shade No. 537) Flammable and toxic White Red and Yellow (IS: 5 Shade Nos. 537 and 356) Gas mixtures (not covered in IS: 4379 or IS: 3933) Major gas colour Minor gas colour with band width approximately 1/5the of the cylinder length\n1\n2\n3\nWhite\nWhite\nWhite\nWhite\nMajor gas colour",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "9",
"title": "9. Labelling of cylinders",
"chapter": null,
"content": "\"WARNING\"\n\"WARNING\"\nGAS CYLINDERS RULES, 2004\nGAS CYLINDERS RULES, 2004\n(i) Do not change the colour of this cylinder.\n(ii) This cylinder should not be filled with any gas other than the one it now contains.\n(iii) No flammable material should be stored in the close vicinity of this cylinder or in the same room in which it is kept.\n(iv) No oil or similar lubricant should be used on the valves or other fittings of this cylinder.\n(v) Please look for the next date of test, which is marked on a metal ring inserted between the valve and the neck of the cylinder, and if this date is over, do not accept the cylinder for filling.",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "10",
"title": "10. Restriction on delivery or despatch of cylinders",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "11",
"title": "11. Repairing of seamless gas cylinders during use",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "12",
"title": "12. Repairing of welded or brazed cylinders",
"chapter": null,
"content": "(a) the defects have been removed by grinding, chipping, gouging or other approved methods;\n(b) the repairing is carried out by a certified welder at the premises of a manufacturer of cylinders recognised by the Chief Controller under the supervision of a competent person by-\n(i) welding, if the original seams were welded;\n(ii) brazing, if the original seams were brazed;\n(c) the cylinder is properly heat-treated after the repairs;\n(d) the welded or brazed seams of the cylinder are radiographed if the cylinder was originally required to be radiographed after its manufacture;\n(e) after repairs and heat-treatment, the cylinder is subjected to the same pneumatic and hydrostatic test or hydrostatic stretch test as was done at the time of manufacture.",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "13",
"title": "13. Prohibition of employment of children and intoxicated persons",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "14",
"title": "14. Prohibition of smoking, fires, lights and dangerous substances",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "15",
"title": "15. General precautions",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "16",
"title": "16. Special precautions against accidents",
"chapter": null,
"content": "(a) comply with the provisions of these rules and the conditions of any license relating thereto;\n(b) observe all precautions for the prevention of accident by fire or explosion;\n(c) prevent any person from committing any act referred to in sub-rule (1).",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "17",
"title": "17. Competent person to be incharge of operations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "18",
"title": "18. Handling and use",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "19",
"title": "19. Restrictions on filling",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "20",
"title": "20. Loading, unloading and transport of cylinders",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 21
},
{
"number": "21",
"title": "21. Storage of cylinders",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 22
},
{
"number": "22",
"title": "22. Electrical installations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 23
},
{
"number": "23",
"title": "23. Purity of gas",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 24
},
{
"number": "24",
"title": "24. Cylinder subjected to the action of fire",
"chapter": null,
"content": "(b) If deleterious structural changes in the material due to the action of heat of the fire is apprehended to have taken place, the cylinder shall have to be subjected to proper heat treatment, followed by hydrostatic test or hydrostatic stretch test, as the case may be, before the cylinder is taken into use.",
"footnote": "",
"is_definition": false,
"sort_order": 25
},
{
"number": "25",
"title": "25. Ownership of cylinder",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 26
},
{
"number": "26",
"title": "26. Re-testing of cylinder",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
{
"number": "27",
"title": "27. Owner's record",
"chapter": null,
"content": "(i) Cylinder manufacturer's name and the rotation number;\n(ii) The specification number to which the cylinder is manufactured;\n(iii) Date of original hydrostatic test or hydrostatic stretch test;\n(iv) Cylinder manufacturer's test and inspection certificates;\n(v) Number and date of letter of approval granted by the Chief Controller.",
"footnote": "",
"is_definition": false,
"sort_order": 28
},
{
"number": "28",
"title": "28. Conversion of cylinders",
"chapter": null,
"content": "(a) inert gases, oxygen and compressed air cylinders made to the same specification and design may be converted from one gas to another after fitting with appropriate valve and painting with appropriate identification colour without prior permission from Chief Controller, with approval of the cylinder owner.\n(b) proper records of such conversions shall be maintained by the gas filler for examination of Chief Controller or Controller as and when needed.\n(i) documentary evidence indicating that the cylinders have been purchased by him;\n(ii) an authenticated copy of letter permitting filling of the cylinders in the past;\n(iii) a statement in duplicate, showing manufacturer's serial numbers of the cylinders in ascending order;\n(iv) a certificate to the effect that the cylinder(s) had not been converted to any other gas service in the past;\n(v) scrutiny fee as specified in Schedule V.",
"footnote": "",
"is_definition": false,
"sort_order": 29
},
{
"number": "31",
"title": "CHAPTER III",
"chapter": "CHAPTER III",
"content": "Importation Of Cylinders\nPART I\nPART I\nGENERAL\nGENERAL",
"footnote": "",
"is_definition": false,
"sort_order": 30
},
{
"number": "29",
"title": "29. License for import of gas cylinders",
"chapter": null,
"content": "PART II\nPART II\nIMPORTATION BY SEA\nIMPORTATION BY SEA",
"footnote": "",
"is_definition": false,
"sort_order": 31
},
{
"number": "30",
"title": "30. Declaration by the master of ship or ship's agent",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 32
},
{
"number": "31",
"title": "31. Production of license for import",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 33
},
{
"number": "32",
"title": "32. Permission of the Commissioner of Customs",
"chapter": null,
"content": "PART III\nPART III\nIMPORTATION BY LAND\nIMPORTATION BY LAND",
"footnote": "",
"is_definition": false,
"sort_order": 34
},
{
"number": "33",
"title": "33. Importation by land",
"chapter": null,
"content": "PART IV\nPART IV\nIMPORTATION BY AIR\nIMPORTATION BY AIR",
"footnote": "",
"is_definition": false,
"sort_order": 35
},
{
"number": "34",
"title": "34. Importation by air",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
{
"number": "38",
"title": "CHAPTER IV",
"chapter": "CHAPTER IV",
"content": "Examination And Testing Of Cylinders",
"footnote": "",
"is_definition": false,
"sort_order": 37
},
{
"number": "35",
"title": "35. Periodicity of examination and testing of cylinders",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
{
"number": "36",
"title": "36. Condemning of cylinders",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 39
},
{
"number": "41",
"title": "CHAPTER V",
"chapter": "CHAPTER V",
"content": "Dissolved Acetylene Gas Cylinders",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
{
"number": "37",
"title": "37. Additional requirements for dissolved acetylene gas cylinders",
"chapter": null,
"content": "(i) The porous substance shall fill as completely as possible the cylinder into which the acetylene is compressed.\n(ii) The porosity of the substance shall not exceed 92 per cent and in no case shall be less than 75 per cent.\n(iii) Any solvent used shall not be capable of chemical reaction with the acetylene gas or with the porous substance or with the metal of the cylinder.\n(iv) If acetone is used as a solvent it shall comply with the requirements of IS: 170, the quantity of acetone including the gas in solution shall be such that the cylinder meets the requirements of additional tests specified in IS: 7312.\n(v) The valves of the cylinders shall not contain more than 70 per cent copper in their composition.\n(vi) The pressure in the cylinder shall not exceed 16 kgf/cm2 at a temperature of 150C.\n(vii) Every cylinder shall before being filled with porous mass be tested by hydrostatic pressure to a pressure of not less than 60 kgf/cm2. This pressure may be reduced to 53 kgf/cm2 if the cylinder is fitted with fusible plug. No cylinder which shows a permanent stretch in excess of 71/2 per cent of the total stretch suffered during hydrostatic stretch test shall be allowed.\n(viii) The safety relief devices, if fitted, shall operate at a pressure of 53 kgf/cm2 or at a temperature of 1000C + 40C/-20C.\n(ix) Every cylinder shall have permanently and conspicuously marked upon it or upon a brass plate soldered to it the name of the manufacturer and the words \"Acetylene properly compressed into porous substance\" and shall bear the following markings, namely:-\n(a) Serial number and identification of manufacturer;\n(b) Number of the standard;\n(c) Test pressure;\n(d) The date of hydrostatic stretch test with code mark of the place where the test was carried out;\n(e) Date of filling of porous mass;\n(f) Water capacity;\n(g) A symbol to indicate the nature of heat treatment;\n(h) Identification of porous mass and porosity percentage;\n(i) Tare weight (inclusive of valve);\n(j) Inspector's official mark;\n(k) Maximum gas capacity.",
"footnote": "",
"is_definition": false,
"sort_order": 41
},
{
"number": "38",
"title": "38. Restriction on filling of dissolved acetylene in cylinders",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 42
},
{
"number": "39",
"title": "39. Examination of dissolved acetylene cylinders before filling",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 43
},
{
"number": "40",
"title": "40. License for compression of acetylene",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 44
},
{
"number": "41",
"title": "41. Record of dissolved acetylene cylinders",
"chapter": null,
"content": "(a) for each charge,\n(i) the date of charging of the cylinder,\n(ii) the empty cylinder weight without gas,\n(iii) the weight of solvent charged before gas charging,\n(iv) full weight of the cylinder;\n(b) the dates upon which solvent has been added;\n(c) the dates upon which the cylinder has been thoroughly examined as provided in rule 39, the results of each such examination and the name of the person carrying out such examination, and in the case of cylinders first issued by the firm, the tare weight of the cylinder including porous substance and acetone or other solvent, the nature of the solvent and the maximum pressure allowed in the cylinder.",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
{
"number": "42",
"title": "42. Labelling of dissolved acetylene cylinders",
"chapter": null,
"content": "(a) date of last filling of gas in the cylinder;\n(b) weight of gas filled;\n(c) full cylinder weight;\n(d) the name of the company filling the gas on the last date of the filling.",
"footnote": "",
"is_definition": false,
"sort_order": 46
},
{
"number": "48",
"title": "CHAPTER VI",
"chapter": "CHAPTER VI",
"content": "Filling And Possession",
"footnote": "",
"is_definition": false,
"sort_order": 47
},
{
"number": "43",
"title": "43. License for filling and possession",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 48
},
{
"number": "44",
"title": "44. No license needed for filling and possession in certain cases",
"chapter": null,
"content": "(a) possession of any cylinder filled with a compressed gas by a carrier or other person for the purpose of transport in accordance with the provisions of these rules;\n(b) possession of cylinders filled with-\n(i) liquefied petroleum gas when the total quantity of gas does not exceed 100 kg at a time;\n(ii) any other flammable but non-toxic gas when the total number of cylinders containing such gas does not exceed 25 or the total weight of gas does not exceed 200 kg., whichever is less, at a time;\n(iii) any non-flammable non-toxic gas when the total number of such cylinders does not exceed 200 at a time;\n(iv) any toxic gas when the total quantity of such cylinders does not exceed 5 at a time;\n(v) acetylene gas contained in cylinders in dissolved state when the total quantity of such cylinder does not exceed 50 at a time.",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
{
"number": "45",
"title": "45. Restriction on filling",
"chapter": null,
"content": "(a) are of approved type and standard as per rule 3 and has been specifically approved for filling by the Chief Controller,\n(b) have passed the examination and test specified in rule 35,\n(c) conform to the provisions of rules 4, 5, 6, 7 and 8.",
"footnote": "",
"is_definition": false,
"sort_order": 50
},
{
"number": "46",
"title": "46. Working pressure and filling ratios",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 51
},
{
"number": "47",
"title": "47. Prior approval of specifications and plans of premises proposed to be licensed",
"chapter": null,
"content": "(a) specifications and plans drawn to scale in triplicate clearly indicating-\n(i) the manner in which the provisions prescribed in these rules will be complied with,\n(ii) the premises proposed to be licensed, the area of which shall be distinctly coloured or otherwise marked,\n(iii) the surrounding area lying within 100 metres of the edge of all facilities which are proposed to be licensed,\n(b) scrutiny fee as specified in Schedule V.",
"footnote": "",
"is_definition": false,
"sort_order": 52
},
{
"number": "48",
"title": "48. No Objection Certificate",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 53
},
{
"number": "49",
"title": "49. Application for license",
"chapter": null,
"content": "(a) in Form `B' for a license prescribed in sub-rule (1) of rule 51; and\n(b) in Form `C', for a license prescribed in sub-rule (2) of rule 51.",
"footnote": "",
"is_definition": false,
"sort_order": 54
},
{
"number": "50",
"title": "50. Grant of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 55
},
{
"number": "51",
"title": "51. Period for which licenses may be granted or renewed",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 56
},
{
"number": "52",
"title": "52. Particulars of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 57
},
{
"number": "53",
"title": "53. Prior approval necessary for alteration in the licensed premises",
"chapter": null,
"content": "(a) three copies of a properly drawn plan to scale, of the licensed premises showing in distinct colours the proposed alterations and the reason therefor;\n(b) scrutiny fee as specified in Schedule V.",
"footnote": "",
"is_definition": false,
"sort_order": 58
},
{
"number": "54",
"title": "54. Amendment of license",
"chapter": null,
"content": "(i) an application duly filled in and signed in Form `B' if the license has been granted in Form `D' and in Form `C' if the license has been granted in Form `E', `F' or `G';\n(ii) the license sought to be amended together with the approved plans attached to it;\n(iii) where any alterations in the licensed premises have been carried out, three copies of the properly drawn plans showing the alterations sanctioned under rule 53 by the Chief Controller or Controller.\n(iv) fees for the amendment of the license as specified in sub-rule (2).\n(i) a letter signed by the holder of the license indicating the full name and postal address of the person to whom he wishes to transfer the license and give complete possession of the licensed premises;\n(ii) the license sought to be transferred together with the approved plan or plans attached to it;\n(iii) an application in Form `C' duly filled and signed by the person to whom the license is sought to be transferred;\n(iv) amendment fee as specified in Schedule V.",
"footnote": "",
"is_definition": false,
"sort_order": 59
},
{
"number": "55",
"title": "55. Renewal of license",
"chapter": null,
"content": "(a) if the application with accompaniments required under sub-rule (4) is not received within the time specified in sub-rule (5) but received not later than three months, the license shall be renewed only on payment of a fee amounting to twice the fee ordinarily payable;\n(b) if such an application with accompaniments is received by the Chief Controller or Controller after three months from the date of expiry but not later than one year from the date of expiry, the license may, without prejudice to any other action that may be taken in this behalf, be renewed on payment of late fee at the rate of one year license fee for every delay of three months or part thereof:",
"footnote": "",
"is_definition": false,
"sort_order": 60
},
{
"number": "56",
"title": "56. Refusal of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 61
},
{
"number": "57",
"title": "57. Suspension and cancellation of license",
"chapter": null,
"content": "(a) before suspending or cancelling a license under this rule, the holder of the license shall be given an opportunity of being heard;\n(b) the maximum period of suspension shall not exceed three months; and\n(c) the suspension of a license shall not debar the holder of the license from applying for its renewal in accordance with the provisions of rule 55.\n(a) where the license is suspended by the licensing authority as an interim measure for violation of any of the provisions of the Act or these rules, or of any condition contained in such license or in his opinion such violation is likely to cause imminent danger to the public:\n(b) where the license is suspended or cancelled by the Central Government, if the Government considers that in the public interest or in the interest of the security of the State such opportunity should not be given.",
"footnote": "",
"is_definition": false,
"sort_order": 62
},
{
"number": "58",
"title": "58. Procedure on expiration, suspension or cancellation of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
{
"number": "59",
"title": "59. Appeal",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 64
},
{
"number": "60",
"title": "60. Procedure on death or disability of licensee",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 65
},
{
"number": "61",
"title": "61. Loss of license",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 66
},
{
"number": "62",
"title": "62. Production of license on demand",
"chapter": null,
"content": "(a) on payment of a fee as specified in Schedule V for each authenticated copy; and\n(b) on the submission of a copy of the plan identical with the approved plan attached to the license.",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
{
"number": "63",
"title": "63. Procedure on reports of infringement",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 68
},
{
"number": "64",
"title": "64. Executive control over authorities",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 69
},
{
"number": "65",
"title": "65. License fee and other than license fee",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 70
},
{
"number": "72",
"title": "CHAPTER VII",
"chapter": "CHAPTER VII",
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 71
},
{
"number": "66",
"title": "66. Power to exempt",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
{
"number": "74",
"title": "CHAPTER VIII",
"chapter": "CHAPTER VIII",
"content": "Accidents And Inquiries",
"footnote": "",
"is_definition": false,
"sort_order": 73
},
{
"number": "67",
"title": "67. Notice of accidents",
"chapter": null,
"content": "(a) to the Chief Controller or Controller under whose jurisdiction the area falls by Fax, E-mail or Telegram (Telegraphic Address-Explosives, Nagpur, E-mail-explosives@explosives.gov.in) followed by a letter giving particulars of the occurrence within 24 hours;\n(b) to the District Magistrate concerned, and\n(c) to the officer-in-charge of the nearest Police Station by the quickest route.",
"footnote": "",
"is_definition": false,
"sort_order": 74
},
{
"number": "68",
"title": "68. Inquiry into accidents",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 75
},
{
"number": "69",
"title": "69. Inquiry into more serious accidents",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 76
},
{
"number": "78",
"title": "CHAPTER IX",
"chapter": "CHAPTER IX",
"content": "Powers",
"footnote": "",
"is_definition": false,
"sort_order": 77
},
{
"number": "70",
"title": "70. Dangerous practices",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 78
},
{
"number": "71",
"title": "71. Powers of inspection, search, seizure, detention and removal",
"chapter": null,
"content": "TABLE\nOfficers Area 1. The Chief Controller or Controller The Whole of India 2. All District Magistrates Their respective Districts 3. All Magistrates subordinate to the District Magistrate Their respective jurisdiction 4. The Commissioner of Police and all Police Officers of rank not below that of an Inspector In Presidency town or their suburbs 5. All Police Officers of rank not below that of Sub-Inspector Their respective area over which their authority extends:\nOfficers\nArea",
"footnote": "",
"is_definition": false,
"sort_order": 79
},
{
"number": "72",
"title": "72. Protection of action taken in good faith",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 80
},
{
"number": "73",
"title": "73. Repeal and savings",
"chapter": null,
"content": "(a) all licenses granted or renewed under the said rules and all fees imposed or levied shall be deemed to have been granted, renewed or imposed or levied, as the case may be, under the corresponding provisions of these rules, and\n(b) all approvals given and all powers conferred by or under any notification or rule shall, so far as they are consistent with the Act and these rules, be deemed to have been given or conferred by or under these rules.\nSCHEDULE I\n[See rule 3(1)]\nTYPES AND STANDARDS OF CYLINDERS AND VALVES A. CYLINDERS AND CONTAINERS\n(a) Cylinders. - Welded low carbon steel cylinders for low pressure liquefiable gases manufactured to IS: 3196, Part 1, Part 2 & Part 4, IS: 7142, AUTO LPG containers to IS: 14899, DA cylinders to IS: 7312 certified by Bureau of Indian Standards.\n(b) Containers. - Tonne containers manufactured to BS: 1500, ASME Section VIII, Division 1, IS: 2825 by M/s. Asco Industrial Corporation, New Delhi, M/s. Indian Sugar and General Engg. Corporation, Yamunagar, M/s. Anup Engineering Ltd., Ahmedabad, M/s. Kosan Metal Products Pvt. Ltd., Mumbai, M/s. Meenakshi Associated Pvt. Ltd., Surajpur, Distt. Ghaziabad, M/s. Titanium Equipment and Anode Manufacturing Co. Ltd., Chennai, M/s. Expo Gas Containers Ltd., Mumbai and certified by an inspection authority approved by Chief Controller.\n(a) Cylinders conforming to BS: 5045:Part 1: 1982 for Halon-1301 and FM 200 gas service as per approved drawings manufactured by M/s. Worthington Heiser Cylinders Gmbh, Austria-inspected and certified by Bureau Veritas.\n(b) Cylinders conforming to BS:5045: Part I: 1982 for permanent and liquefiable gases as per approved drawings, manufactured by M/s. Worthington Heiser Cylinders Gmbh, Austria-inspected and certified by Bureau Veritas.\n(c) Seamless steel cylinders for CNG gas on-board service to NZS:5454-1989 specification, having working pressure 200 Bar and test pressure 335 Bar manufactured by M/s. Worthington Cylinders Gmbh, Austria certified by M/s. Bureau Veritas as per approved drawings.\n(a) Seamless steel cylinders for permanent gases (Air/Oxygen) conforming to BS: 5045:Part I:1982 manufactured by M/s. Faber Industries S.P.A., Italy-inspected and certified by Lloyd's as per approved drawings.\n(b) Seamless steel cylinders for compressed and liquefiable gases conforming to DOT:3AA specification having water capacity 80.0 ltrs. & 120 ltrs. working pressure 79 Bar and test pressure 132 Bar, manufactured by M/s. Faber Industries S.P.A., Italy-inspected and certified by M/s. Lloyd's as per approved drawings.\n(c) Seamless steel cylinders for CNG gas on-board service to NZS:5454-1989 having working pressure 200 Bar and test pressure 335 Bar manufactured by M/s. Faber Industries, S.P.A., Italy, certified by M/s. Lloyd's as per approved drawings.\n(a) Aluminium alloy cylinders conforming to BS:5045:Pt. 3 or EN equivalent specification manufactured by M/s. Luxfur Gas Cylinders, UK-inspected and certified by Lloyd's or British Inspecting Engineers Ltd. as per approved drawings.\n(b) Seamless steel cylinders for permanent and liquefiable gases conforming to BS:5045:Part I manufactured by M/s. UEF Chesterfield Cylinders, UK-inspected and certified by Lloyd's or Bureau Veritas or British Inspecting Engineering Ltd., or any other appropriate authority as per approved drawings.\n(c) Seamless steel cylinders for permanent and liquefiable gases conforming to DOT:3T specification manufactured by M/s. UEF Chesterfield Cylinders, UK-inspected and certified by British Inspecting Engineers Ltd., as per approved drawings.\n(d) Seamless steel cylinders for FM-200 gas service conforming to DOT:4BA:500 specification manufactured by M/s. Fike Protection & Systems, UK, having water capacity 650 pounds, filling ratio 1.04 super pressurised with Nitrogen at 19.72 Bar as per approved drawings.\n(e) Seamless steel cylinders for CNG gas on-board service to BS:5045-1982: Part I having working pressure 200 Bar and test pressure 344 Bar manufactured by M/s. UEF Chesterfield Cylinders, Derbyshire, UK certified by M/s. British Inspection Engineers Ltd. as per approved drawings.\n(a) Steel cylinders-inspected and certified by appropriate authority, conforming to specifications DOT:3A/3AA for permanent and liquefiable gases manufactured by (1) M/s. Norris Cylinder Co., (2) M/s. Taylor Wharton Co., (3) M/s. Worthington Cylinder Co., (4) M/s. Norristi Industries, (5) M/s. Harris Burg Steel Co., and (6) M/s. Pressed Steel Tank Co., as per approved drawings.\n(b) Aluminium alloy cylinders conforming to DOT:3AL Specification manufactured by M/s. Luxfer Gas Cylinders, USA-inspected and certified by Authorised Testing Inc. or Arrowhead Inc., as per approved drawings.\nB. VALVES\nNote.\nSCHEDULE II\n[See rule 3(2)]\n(A) The test and inspection certificates to be obtained from the Inspecting Authority in respect of cylinders manufactured in accordance with the approved design and specification or Code shall include the following particulars, namely:-\n(B) The test and inspection certificates to be obtained from the Inspecting Authority in respect of valves manufactured in accordance with the approved design and specification or Code shall include the following particulars, namely:-\n(a) Valve inlet connection..........................................\n(b) Valve outlet connection.........................................\n(c) Valve outlet number.............................................\n(d) Hydraulic Pressure Test.........................................\n(e) Pneumatic Proof Test............................................\n(f) Tensile strength................................................\n(g) Elongation per cent.............................................\n(h) Impact strength.................................................\n(i) Quantity offered for inspection.................................\n(j) Quantity passed.................................................\n(k) Quantity rejected and reasons for rejection.....................\nSCHEDULE III\n[See rule 3(3)]\nPARTICULARS TO BE SUBMITTED BY PERSON DESIRING TO FABRICATE CYLINDER, VALVES AND OTHER FITTINGS\n(i) Date from which such container/valves were manufactured.\n(ii) For whom the container/valves were fabricated and their approximate numbers.\n(iii) Details of the containers/valves manufactured.\n3. Specification/ Codes proposed to be adopted for the manufacture of cylinders/containers/valves.\n(ii) Details of templates/gauges provided to check/test.\n(iii) Steps taken to check the accuracy of testing and checking equipment and frequency of such checking.\n(i) Proforma of records for various tests carried out by the inspecting and certifying organisation, and (ii) Proforma of test and inspection certificate issued by the independent inspecting authority. 13. Whether the manufacturing unit has been certified under ISO or equivalent certification (if so, documentary evidence thereof to be attached).\n(ii) Proforma of test and inspection certificate issued by the independent inspecting authority.\n............................\nSignature\nName and designation\nSCHEDULE IV\n(See rule 35)\nA. FACILITIES REQUIRED FOR CYLINDER TESTING STATIONS\nNote.\n(i) have at least two years' experience in the examination of gas cylinder;\n(ii) be at least 21 years of age;\n(iii) be conversant with these rules, codes, specifications and/or regulations applying to the cylinders for which the test station is approved.\nEQUIPMENT\n(i) One set of these rules, codes, specifications and/or regulations applying to the cylinders, which the test station is authorised to test. All these rules, codes, specifications and/or regulations shall be maintained with all current amendments.\n(ii) Hydrostatic test apparatus comprising pressurizing equipment, pressure gauge and volumetric measuring equipment in accordance with IS:5844-Hydrostatic stretch testing of compressed gas cylinders. The apparatus shall be equipped with at least two 15 cm diameter (minimum) working pressure gauges.\n(iii) Non-destructive testing facilities like ultrasonic flaw detection, acoustic emission techniques, etc., for detection of stress corrosion cracks developed during the service.\n(iv) Dead-weight pressure gauge tester of appropriate pressure range or a master pressure gauge of 15 cm minimum diameter covering the appropriate pressure range.\n(v) Boroscope, extra-low voltage lamps to permit adequate internal viewing of cylinders and other lamps necessary for close examination of external surfaces.\n(vi) Straightedges, templates, miscellaneous tool and gauges for measurement.\n(vii) Weighing equipment, where applicable.\n(viii) One set of standard test weights for the weighing machine, stamped by the relevant statutory authority.\n(ix) Adequate cylinder handling equipment.\n(x) Adequate cylinder draining equipment.\n(xi) Facilities for internal drying of cylinders.\n(xii) Marking and stamping equipment.\n(i) Hydrostatic test apparatus in accordance with IS:5844. Volumetric equipment shall be capable of measuring a permanent change in volume of the cylinder under test of the order of 1/20,000 of its total capacity.\n(ii) Weighing equipment error not greater than ±0.1 per cent.\n(iii) Working pressure gauge error not greater than 1 per cent of the pressure.\n(iv) Master pressure gauge error not greater than 0.25 per cent of the full-scale deflection.\n(i) Working pressure gauge-1 month.\n(ii) Master pressure gauge-6 months.\n(iii) Weighing equipment-checked by test weight daily when in service.\n(iv) Test weights-2 years.\n(i) It shall have good lighting to permit ready external examination of gas cylinders, preferably including natural lighting.\n(ii) It shall have adequate ventilation to remove residual gases from cylinders.\n(iii) It shall provide sufficient space to permit safe working.\n(iv) It shall be maintained in a clean dry condition.\nB. TESTING OF CYLINDERS\n(i) The cylinder contents shall be released in a safe manner keeping in mind dangers associated with the nature of the gas in the cylinder. Cylinders, which contain or may have been contaminated by poisonous or obnoxious substances, shall be emptied only by test stations properly equipped and experienced to handle the particular gas/substance. Such cylinders shall be clearly labelled that they have been contaminated.\n(ii) The valve shall be opened and if no gas escapes and the port is not visibly blocked, a charge of low-pressure nitrogen or other inert gas shall be blown into the valve outlet. Discharge of gas after removal of the nitrogen supply indicates that the cylinder is empty. When no gas discharges the valves shall be treated as \"obstructed\". Where a cylinder has contained poisonous or obnoxious substances, and the valve is suspected of being obstructed, the gas shall be released within an approved appliance and the valves shall be removed in such a manner that the gas escapes without danger to the operator.\n(iii) Should the valve be obstructed the contents of the cylinder shall be released in safe manner as stated in (i) above. Work on cylinders containing combustible gases shall be carried out in the open air.\nNote.\n(a) Approved blasting, rotary wire brushing;\n(b) Burn out treatment carried out in a furnace at a temperature not exceeding 300°C for a period of not exceeding one hour after which all free rusts and any other foreign matter shall be removed by steam cleaning or washing with approved solvents.\n(i) The cylinders shall be subjected to hydrostatic stretch test in accordance with IS: 5844. The test pressure applied to the cylinder shall be retained for a period of not less than 30 seconds.\n(ii) The permanent stretch suffered by the cylinder due to application of test pressure shall not exceed the following limits, namely:-\n(a) In the case of cylinder below 20 litres water capacity for non-corrosive gases 10% of the total stretch suffered during the test (b) In other cases 10% of the total stretch suffered during the test or 1/5000th of the original volume of the cylinder, whichever is less\n(iii) Any reduction in pressure noticed during the retention of 30 seconds or any leakage, visible bulge or deformation should be treated as case of failure in the test.\n(i) The cylinder shall be subjected to hydrostatic test in accordance with IS: 5844 by non-jacket method except that the volumetric changes during the test need not be measured.\n(ii) The test pressure shall be retained for a period of not less than 30 seconds. Any reduction in pressure noticed during this retention period or any leakage, visible bulge or deformation shall be treated as case of failure in the test.\n(a) Name of the manufacturer and the owner of the cylinder.\n(b) Rotation Number.\n(c) The specification to which the cylinder conforms.\n(d) Date of original hydrostatic/hydrostatic stretch test.\n(e) Test reports and certificates furnished by the manufacturer, if available.\n(f) Test pressure.\n(g) Maximum working pressure.\n(h) Water capacity.\n(i) Tare weight.\n(j) Variation, if any, in the tare weight marked on the cylinder and actual tare weight.\n(k) Condition of cylinder shell.\n(l) Name of gas.\n(m) Type of valve fitted, and\n(n) Remarks, if any.\nNote.\nSCHEDULE V\n(See rules 2(xx), 3, 28, 35, 47, 50, 53, 54, 61, 62 and 65)\nALL FEES SHALL BE PAID IN THE MANNER PRESCRIBED IN SUB-RULE (2) OF RULE 65\nA. LICENSE FEES\nSl . No. Form of license Purpose for which granted Authority empowered to grant license Fees Rupees 1. D To import cylinder filled or intended to be filled with compressed gas Chief Controller For the first 100 nos. cylinders or part thereof. 500.00 Exceeding 100 nos. but not exceeding 500 nos. cylinders. 1,000.00 Exceeding 500 nos. of cylinders Rs. 2000 for every additional 500 nos. of cylinders or part thereof. 2. E To fill compressed gas in cylinders Chief Controller or Controller For each type of gas filled in the plant, namely (a) toxic, (b) non-toxic and non-flammable, (c) non-toxic and flammable, (d) dissolved acetylene gas, (e) non-toxic and flammable liquefiable gas other than LPG or (f) liquefied petroleum gas, as the case may be. 2,500.00 3. F (a) To store compressed gas in cylinders in storage shed attached to the filling premises Chief Controller or Controller (i) For toxic and flammable gases (permanent as well as liquefied). (b) To store compressed gas in cylinders in storage shed other than attached to the filling premises Controller Not exceeding 100 nos. cylinders. 500.00 Exceeding 100 nos. but not exceeding 500 nos. cylinders. 1,000.00 Exceeding 500 nos. of cylinders, Rs. 1,000 for every additional 500 nos. of cylinders or part thereof (ii) For non-toxic and non-flammable gases (permanent as well as liquefied): Not exceeding 500 nos. of cylinders.\nExceeding 500 nos. of cylinders, Rs. 1,000 for every additional 500 nos. of cylinders or part thereof (iii) For liquefied petroleum gases: 500.00 Exceeding 100 Kg. but not exceeding 500 Kg. 500.00 Exceeding 500 Kg. but not exceeding 2,000 Kg. 1,000.00 Exceeding 2,000 Kg. but not exceeding 5,000 Kg. 2,000.00 Exceeding 5,000 Kg. but not exceeding 10,000 Kg. 3,000.00 Exceeding 10,000 Kg. for Rs. 1,000 every additional 5,000 Kg. or part thereof. (iv) For acetylene gas contained in cylinders in dissolved state: Not exceeding 200 cylinders Rs. 500 for every additional 200 nos. of cylinders or part thereof 500.00 4. G To dispense CNG as automotive fuel from a mother station, daughter station or a CNG online station . Chief Controller 5,000.00\nSl . No.\nSl\n. No.\nForm of license\nForm of license\nPurpose for which granted\nPurpose for which granted\nAuthority empowered to grant license\nAuthority empowered to grant license\nFees\nFees\nRupees\nRupees\n1.\nD\nChief Controller\n500.00\n1,000.00\n2.\nE\nChief Controller or Controller\n2,500.00\n3.\nF\nChief Controller or Controller\nController\n500.00\n1,000.00\n500.00\n500.00\n1,000.00\n2,000.00\n3,000.00\n500.00\n4.\nG\nChief Controller\n5,000.00\nSl . No Purpose Fees Rupees 1. Issue of filling permission under clause B of sub-rule (2)(vii) of rule 3 Scrutiny fee for the first 100 nos.\nof cylinders or part thereof Exceeding 100 nos. of cylinders Rs. 1,000 for every additional 500 cylinders or part thereof. 500.00 2. Approval of design for manufacture of cylinders or valves or regulators under sub-rule (4)(a) of rule 3 (a) Scrutiny fee (b) For subsequent approval of any change in the design 2,000.00 500.00 3. Conversion of cylinders under sub-rule\n(2) of rule 28 Scrutiny fee for the first 10 nos. of cylinders or part thereof Exceeding 10 nos. of cylinders 200.00 500.00 4. Approval of cylinder testing station under rule 35 Scrutiny fee 2,000.00 5. Prior approval of specifications and plans under rule 47 or 53 Scrutiny fee 400.00 6. Amendment of license under rule 54 Amendment fee In the case of amendment involving licensed capacity, the difference in licence fee shall be added to the amendment fee mentioned above 400.00 7. Issue of duplicate copy of license under rule 61 Scrutiny fee 200.00 8. Issue of authenticated copy of license under rule 62 Scrutiny fee 400.00\nSl . No\nSl\n. No\nPurpose\nPurpose\nFees\nFees\nRupees\nRupees\n1.\n500.00\n2.\n2,000.00\n500.00\n3.\n200.00\n500.00\n4.\n2,000.00\n5.\n400.00\n6.\n400.00\n7.\n200.00\n8.\n400.00\nFORM A\nFORM A\n[See rule 30(2)]\nDeclaration to be made by the Master of a ship carrying Cylinder filled with compressed gas before entering a port or by the ship's agent\nName of ship...................................\nDescription of filled cylinders True chemical name and nature of the gas, i.e., whether flammable, corrosive or toxic Total quantity carried in the ship Quantity to be landed at port Remarks No.\nof cylinders Kg .\nor M 3 of gas No.\nof cylinders Kg.\nor M 3 of gas\nDescription of filled cylinders\nDescription of filled cylinders\nTrue chemical name and nature of the gas, i.e., whether flammable, corrosive or toxic\nTrue chemical name and nature of the gas, i.e., whether flammable, corrosive or toxic\nTotal quantity carried in the ship\nTotal quantity carried in the ship\nQuantity to be landed at port\nQuantity to be landed at port\nRemarks\nRemarks\nNo.\nof cylinders\nKg .\nor M 3 of gas\nNo.\nof cylinders\nKg.\nor M 3 of gas\n...................................\nSignature of Master/Agent of ship\n(with official stamp)\nFORM B\nFORM B\n(See rules 49 and 54)\nApplication for the grant/amendment of a license to import cylinders\n(i) Applicant's calling (ii) Applicant's full postal address (iii) Telephone No. (s) and E-mail 2. Particulars of storage license held by: (i) Number and date of storage license issued by the Chief Controller /Controller (ii) Renewed/valid upto (iii) Capacity of storage as per above license 3. Description of the cylinders to be imported:\n(ii) Applicant's full postal address (iii) Telephone No. (s) and E-mail 2. Particulars of storage license held by:\n(iii) Telephone No. (s) and E-mail\n(i) Number and date of storage license issued by the Chief Controller /Controller\n(ii) Renewed/valid upto\n(iii) Capacity of storage as per above license\n(i) Number of cylinders (ii) Specification of cylinders (iii) Manufactured by (iv) Inspected and tested by (v) Specification of the valves fitted to the cylinders (vi) *Filled with..................(True chemical name of the gas) (vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks Date of application........................ .............................. Signature of applicant Postal address of the applicant Note. - 1. Particulars marked with * are not required to be furnished if empty cylinders are desired to be imported. 2. Manufacturers test and inspection certificates complete in all respects pertaining to each lot of cylinders and valve shall accompany this application. 3. In case cylinders are desired to be imported duly filled with gas, filler certificates in respect of items 3(vi), (vii) and (ix) shall be furnished. FORM C (See rules 49, 54 and 55) Application for the grant/amendment/renewal of a license to fill and/or store compressed gas in cylinders Documents listed overleaf must be enclosed with this application, if it is for the grant of a license in Forms 'E', 'F' and 'G'. The replies to be given in this column.\n(ii) Specification of cylinders (iii) Manufactured by (iv) Inspected and tested by (v) Specification of the valves fitted to the cylinders (vi) *Filled with..................(True chemical name of the gas) (vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks Date of application........................ .............................. Signature of applicant Postal address of the applicant Note. - 1. Particulars marked with * are not required to be furnished if empty cylinders are desired to be imported. 2. Manufacturers test and inspection certificates complete in all respects pertaining to each lot of cylinders and valve shall accompany this application. 3. In case cylinders are desired to be imported duly filled with gas, filler certificates in respect of items 3(vi), (vii) and (ix) shall be furnished. FORM C (See rules 49, 54 and 55) Application for the grant/amendment/renewal of a license to fill and/or store compressed gas in cylinders Documents listed overleaf must be enclosed with this application, if it is for the grant of a license in Forms 'E', 'F' and 'G'. The replies to be given in this column.\n(iii) Manufactured by (iv) Inspected and tested by (v) Specification of the valves fitted to the cylinders (vi) *Filled with..................(True chemical name of the gas) (vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks Date of application........................ .............................. Signature of applicant Postal address of the applicant Note. - 1. Particulars marked with * are not required to be furnished if empty cylinders are desired to be imported. 2. Manufacturers test and inspection certificates complete in all respects pertaining to each lot of cylinders and valve shall accompany this application. 3. In case cylinders are desired to be imported duly filled with gas, filler certificates in respect of items 3(vi), (vii) and (ix) shall be furnished.\n(iv) Inspected and tested by (v) Specification of the valves fitted to the cylinders (vi) *Filled with..................(True chemical name of the gas) (vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks Date of application........................ .............................. Signature of applicant Postal address of the applicant Note. - 1. Particulars marked with * are not required to be furnished if empty cylinders are desired to be imported. 2. Manufacturers test and inspection certificates complete in all respects pertaining to each lot of cylinders and valve shall accompany this application.\n(v) Specification of the valves fitted to the cylinders (vi) *Filled with..................(True chemical name of the gas) (vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks Date of application........................ .............................. Signature of applicant Postal address of the applicant Note. - 1. Particulars marked with * are not required to be furnished if empty cylinders are desired to be imported.\n(vi) *Filled with..................(True chemical name of the gas) (vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks Date of application........................\n(vii) *Filling pressure at 15°C if filled with permanent gas or dissolved acetylene (viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port 6. Remarks\n(viii) *Filling ratio, if filled with a liquefiable gas (ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................ 5. Name of the port\n(ix) Date of last hydraulic stretch test (x) Rotation numbers of cylinders 4. Cylinders proposed to be stored at................\n(x) Rotation numbers of cylinders\n..............................\nSignature of applicant\nPostal address of the applicant\nNote.\nFORM C\nFORM C\n(See rules 49, 54 and 55) Application for the grant/amendment/renewal of a license to fill and/or store compressed gas in cylinders Documents listed overleaf must be enclosed with this application, if it is for the grant of a license in Forms 'E', 'F' and 'G'.\nApplication for the grant/amendment/renewal of a license to fill and/or store compressed gas in cylinders",
"footnote": "",
"is_definition": false,
"sort_order": 81
},
{
"number": "1",
"title": "1. Name in which license required** .............................................................. Applicant's calling .............................................................. Applicant's full postal address .............................................................. 2. Situation of the premises where compressed gas is to be stored /filled: State .............................................................. District .............................................................. Town or",
"chapter": null,
"content": "..............................................................\nApplicant's calling\n..............................................................\nApplicant's full postal address\n..............................................................\nState\n..............................................................\nDistrict\n..............................................................\nTown or village\n..............................................................\nSurvey No. and name of road\n..............................................................\nNearest Police Station\n..............................................................\nNearest Railway Station\n..............................................................\n..............................................................\n..............................................................\n..............................................................\n..............................................................\n..............................................................\nDOCUMENTS REQUIRED TO BE SUBMITTED WITH THIS APPLICATION FOR A LICENSE IN FORM 'E', 'F' AND 'G'\n(i) Four copies of specifications and plans approved under rule 47. (Not required for renewal of a license without amendments). (ii) License together with approved plans and specifications attached thereto. (Not required for the first grant or a license). (iii) Requisite amount of fee for the grant, amendment or renewal of a license paid in the manner specified in rule 65. (iv) Documentary evidence in support of legal physical possession of the premises proposed to be licensed, copies of lease agreement, partnership deed/memorandum and article of association, approval/clearance/permit as applicable from the Local Administration, etc. (v) An undertaking stating that all necessary clearances from revenue, fire, local administration, etc., have been obtained and the construction of the premises has been completed as per approved plan complying with all relevant requirements under these rules. (vi) No Objection Certificate from the District Authority under rule 48 in the case of application for license in Form 'G'. FORM D (See rules 50, 51 and 54) License to import Gas Cylinders by Sea License No................ Fee Rs .................... License is hereby granted to M/s.............................to import by sea at any one time cylinders of the description given below at the port ......................for consignment to .................subject to the provisions of the Explosives Act, 1884 (4 of 1884) and the rules framed thereunder and to the conditions of this license. The license shall remain in force till the..............20......... Date ............. Chief Controller of Explosives Description of the Cylinders 1. Number of cylinders\n(ii) License together with approved plans and specifications attached thereto. (Not required for the first grant or a license). (iii) Requisite amount of fee for the grant, amendment or renewal of a license paid in the manner specified in rule 65. (iv) Documentary evidence in support of legal physical possession of the premises proposed to be licensed, copies of lease agreement, partnership deed/memorandum and article of association, approval/clearance/permit as applicable from the Local Administration, etc. (v) An undertaking stating that all necessary clearances from revenue, fire, local administration, etc., have been obtained and the construction of the premises has been completed as per approved plan complying with all relevant requirements under these rules. (vi) No Objection Certificate from the District Authority under rule 48 in the case of application for license in Form 'G'. FORM D (See rules 50, 51 and 54) License to import Gas Cylinders by Sea License No................ Fee Rs .................... License is hereby granted to M/s.............................to import by sea at any one time cylinders of the description given below at the port ......................for consignment to .................subject to the provisions of the Explosives Act, 1884 (4 of 1884) and the rules framed thereunder and to the conditions of this license. The license shall remain in force till the..............20......... Date .............\n(iii) Requisite amount of fee for the grant, amendment or renewal of a license paid in the manner specified in rule 65. (iv) Documentary evidence in support of legal physical possession of the premises proposed to be licensed, copies of lease agreement, partnership deed/memorandum and article of association, approval/clearance/permit as applicable from the Local Administration, etc. (v) An undertaking stating that all necessary clearances from revenue, fire, local administration, etc., have been obtained and the construction of the premises has been completed as per approved plan complying with all relevant requirements under these rules. (vi) No Objection Certificate from the District Authority under rule 48 in the case of application for license in Form 'G'. FORM D (See rules 50, 51 and 54) License to import Gas Cylinders by Sea License No................ Fee Rs .................... License is hereby granted to M/s.............................to import by sea at any one time cylinders of the description given below at the port ......................for consignment to .................subject to the provisions of the Explosives Act, 1884 (4 of 1884) and the rules framed thereunder and to the conditions of this license. The license shall remain in force till the..............20.........\n(iv) Documentary evidence in support of legal physical possession of the premises proposed to be licensed, copies of lease agreement, partnership deed/memorandum and article of association, approval/clearance/permit as applicable from the Local Administration, etc. (v) An undertaking stating that all necessary clearances from revenue, fire, local administration, etc., have been obtained and the construction of the premises has been completed as per approved plan complying with all relevant requirements under these rules. (vi) No Objection Certificate from the District Authority under rule 48 in the case of application for license in Form 'G'. FORM D (See rules 50, 51 and 54) License to import Gas Cylinders by Sea License No................ Fee Rs .................... License is hereby granted to M/s.............................to import by sea at any one time cylinders of the description given below at the port ......................for consignment to .................subject to the provisions of the Explosives Act, 1884 (4 of 1884) and the rules framed thereunder and to the conditions of this license.\n(v) An undertaking stating that all necessary clearances from revenue, fire, local administration, etc., have been obtained and the construction of the premises has been completed as per approved plan complying with all relevant requirements under these rules. (vi) No Objection Certificate from the District Authority under rule 48 in the case of application for license in Form 'G'. FORM D (See rules 50, 51 and 54) License to import Gas Cylinders by Sea License No................\n(vi) No Objection Certificate from the District Authority under rule 48 in the case of application for license in Form 'G'.\nFORM D\nFORM D\n(See rules 50, 51 and 54)\nLicense to import Gas Cylinders by Sea\nFee Rs ....................\nChief Controller of Explosives\nDescription of the Cylinders\n(True chemical name of the gas)\nConditions of license\nFORM E\nFORM E\n(See rules 50, 51 and 54)\nLicense to fill compressed gas in cylinders\nFee Rs ..........................\nDescription and location of the licensed premises\nType of gas Quantity (a) Toxic (b) Non-toxic and non-flammable (c) Non-toxic and flammable (d) Dissolved acetylene gas (e) Non-toxic and flammable liquefiable gas other than LPG (f) Liquefied petroleum gas and is situated at ....................\nType of gas\nType of gas\nQuantity\nQuantity\nThis license should be renewable without any concession in fee for ten years in the absence of contraventions of Explosives Act, 1884 or Gas Cylinders Rules, 2004, framed there under or of the conditions of this license Date of renewal Date of expiry Signature and office stamp of the licensing authority\nDate of renewal\nDate of expiry\nSignature and office stamp of the licensing authority\nConditions\n(i) such cylinder has been approved in writing by the Chief Controller for filling; (ii) the cylinder has been examined and tested as required under the relevant rules. 3. Before filling, every cylinder with its valve and other fittings shall be carefully examined to ensure that it complies in all respects with the relevant provisions of the rules before it is passed for filling.\n(ii) the cylinder has been examined and tested as required under the relevant rules.\nFORM F\nFORM F\n(See rules 50, 51 and 54)\nLicense to store compressed gas in cylinders\nFee Rs...................................\nChief Controller/Controller of Explosives\nType of gas Quantity (a) Toxic (b) Non-toxic and non-flammable (c) Non-toxic and flammable (d) Dissolved acetylene gas (e) Non-toxic and flammable liquefiable gas other than LPG (f) Liquefied petroleum gas and is situated at ....................\nType of gas\nType of gas\nQuantity\nQuantity\nThis license shall be renewable without any concession in fee for ten years in the absence of contraventions of Explosives Act, 1884 or Gas Cylinders Rules, 2004, framed there under or of the conditions of this license Date of renewal Date of expiry Signature and office stamp of the licensing authority\nDate of renewal\nDate of expiry\nSignature and office stamp of the licensing authority\nConditions\n(b) All facilities used for storage of LPG, CNG and Auto LPG shall comply with provisions of OISD-STD-144, 150, OISD-GDN-169, STD-179 and 210, as the case may be.\nQuantity of compressed gas in cylinder Minimum distance to be kept clear Kg Meters 0 - 100 - 101 - 2,000 3 2,001 - 3,000 4 3,001 - 4,000 5 4,001 - 6,000 6 6,001 - 8,000 7 8,001 - 10,000 8 10,001 - 12,000 9 12,001 - 20,000 12 over 20,000 15\nQuantity of compressed gas in cylinder\nQuantity of compressed gas in cylinder\nMinimum distance to be kept clear\nMinimum distance to be kept clear\nKg\nKg\nMeters\nMeters\n-\n3\n4\n5\n6\n7\n8\n9\n12\n15\n(i) filled cylinders shall be stored vertically and not be stacked more than 2 high;\n(ii) empty cylinders if stored vertically, shall not be stacked more than 3 high and; if stored horizontally, shall not be stacked more than 5 high;\n(iii) the pile of the cylinders shall be kept stable by using chocks at the ends;\n(iv) at least 60 centimeter wide gangway, to permit access and manoeuvering of cylinders, shall be left between stacks of single or double rows and between stacks and walls.\n(b) No person shall smoke in the storage shed or carry matches, fuses, mobile phones or other appliances producing ignition in the premises. Conspicuous \"No smoking\" signs in Hindi, English and the regional language shall be pasted or hung up at prominent places outside the storage shed.\nFORM G\nFORM G\n(See rules 50, 51 and 54)\nLicense to dispense compressed natural gas in a CNG dispensing station as automotive fuel\nFee Rs..........................\nChief Controller of Explosives\nDescription and Location of the Licensed Premises\nSpace for Endorsement of Renewals\nThis license shall be renewable without any concession in fee for ten years in the absence of contraventions of Explosives Act, 1884 or Gas Cylinders Rules, 2004, framed there under or of the conditions of this license Date of renewal Date of expiry Signature and office stamp of the licensing authority\nDate of renewal\nDate of expiry\nSignature and office stamp of the licensing authority\nConditions\nTABLE I\nTABLE I\nINTER DISTANCES\nFrom buildings and outer boundaries togas storage units\nTotal capacity of gas storage cascade units (in litres) Minimum distance from buildings and boundaries (in meters) Up to 4,500 2.5 4,500 to 10,000 4.0 10,000 to 10,0000 10.0\nTotal capacity of gas storage cascade units (in litres)\nTotal capacity of gas storage cascade units (in litres)\nMinimum distance from buildings and boundaries (in meters)\nMinimum distance from buildings and boundaries (in meters)\nUp to 4,500\n2.5\n4,500 to 10,000\n4.0\n10,000 to 10,0000\n10.0\nNote.\nTABLE II\nTABLE II\nINTER DISTANCES BETWEEN VARIOUS FACILITIES IN THE CNG FUELLING STATION\nSl . No. Distance from (in meters) CNG compressor CNG dispensing unit Storage cascade wall/ CLF* Outer boundary MS/HSD dispenser Vent of MS/HSD u/g storage tanks Filling point of MS/HSD 1. CNG compressor - 3 2 3 6 6 T-1(Min-3) 2. CNG dispensing unit 3 - 2 4 6 4 -do- 3. Storage cascade 2 2 - T-1 T-1\n(Min-6) T-1\n(Min-4) -do- 4. Outer boundary wall/CLF* 3 4 T-1 - 6 4 -do- 5. MS/HSD dispenser 6 6 T-1\n(Min-6) 6 - 6 -do- 6. Vent of MS/HSD u/g storage tanks 6 4 T-1\n(Min-4) 4 6 - 6 7. Filling point of MS/HSD T-1\n(Min-3)\nSl . No.\nSl\n. No.\nDistance from (in meters)\nDistance from (in meters)\nCNG compressor\nCNG compressor\nCNG dispensing unit\nCNG dispensing unit\nStorage cascade wall/ CLF*\nStorage cascade wall/ CLF*\nOuter boundary\nOuter boundary\nMS/HSD dispenser\nMS/HSD dispenser\nVent of MS/HSD u/g storage tanks\nVent of MS/HSD u/g storage tanks\nFilling point of MS/HSD\nFilling point of MS/HSD\n1.\n-\n3\n2\n3\n6\n6\nT-1(Min-3)\n2.\n3\n-\n2\n4\n6\n4\n-do-\n3.\n2\n2\n-\nT-1\nT-1\n(Min-6)\nT-1\n(Min-4)\n-do-\n4.\n3\n4\nT-1\n-\n6\n4\n-do-\n5.\n6\n6\nT-1\n(Min-6)\n6\n-\n6\n-do-\n6.\n6\n4\nT-1\n(Min-4)\n4\n6\n-\n6\n7.\nT-1\n(Min-3)\nNote.\n(i) T-1 denotes Table I.\n(ii) Distances shown as \"-\" shall be any distance necessary for operational convenience.\n(iii) A suitable curbing platform shall be provided at the base of the dispensing unit to prevent vehicles from coming too near the unit.\n(iv) A CNG cascade having cylinders of total water capacity not exceeding 4,500 litres can be mounted on top of the compressor superstructure. The assembly shall observe 3 meter clearance around and also from the dispensing unit. This can be reduced to 2 meter as per Note-(i) of Table I.\nLocation Type of extinguishers Dispensing Unit 1x10 kg DCP Compressor\n(On-line) 1x10 kg DCP (Mother Station) 1x70 kg DCP CNG storage 1x10 kg DCP Cascade refueling area 1x10 kg DCP MCC/Electrical installation 1x4.5 kg CO 2 per 25 Sq. M. floor area\nLocation\nLocation\nType of extinguishers\nType of extinguishers\nDispensing Unit\n1x10 kg DCP\nCompressor\n(On-line)\n1x10 kg DCP\n(Mother Station)\n1x70 kg DCP\nCNG storage\n1x10 kg DCP\nCascade refueling area\n1x10 kg DCP\nMCC/Electrical installation\n1x4.5 kg CO 2 per 25 Sq. M. floor area\nSCHEDULE VI\n(See rule 20)\nTRANSPORT OF CYLINDERS\nTransport of cylinders by vehicles.\n(b) Cylinders shall be so transported as not to project in the horizontal plane beyond the sides or ends of the vehicle by which they are transported.\n(c) There shall be no sharp projections on the inside of the vehicle.\n(d) Cylinders shall be adequately secured to prevent their falling off the vehicle and being subjected to rough handling, excessive shocks or local stresses.\n(e) Cylinders transported in vehicles shall be blocked or braced and be so secured to prevent movement, striking each other or falling down.\n(f) Cylinders filled with any compressed gas shall not be transported alongwith any other article of a highly flammable or corrosive nature.\nRestriction on transport.\n(b) Cylinders containing toxic or corrosive gas shall not be transported alongwith foodstuffs.\nLoading and unloading for transport.\n(b) Where any such operation is carried on by means of a crane or a fork-lift truck, a proper cradle with chains or wire rope slings shall be used.\nProtection of valves during transport.\n(b) Where the design of the cylinder does not provide for the valve lying wholly below the level of the body of the cylinder, a stout metal cap, metal cover or a protective metal ring or grill of a design approved by the Chief Controller shall be provided, the design being such that the cap or cover or ring or grill is nowhere in close proximity to any part of the valve or valve body.\n(c) Where metal caps or metal covers are provided, to protect valves fitted to cylinder other than those containing highly toxic gases like Hydrogen cyanide, Phosgene, Cyanogen, Cyanogen chloride, it shall be provided with a vent of such size so as to prevent any gas pressure inside the cap or covers.\n(d) Cylinders containing highly toxic gases like Hydrogen cyanide, Phosgene, Cyanogen, Cyanogen chloride gases, shall have their valves protected with gas-tight metal caps or covers.\n(e) Nothing in sub-rules (a), (b) and (c) shall apply to cylinders containing oxygen or nitrous oxide for medical purpose having water capacity not exceeding 5 litres.\nLeaky cylinders.\n(b) Any cylinder containing a flammable or toxic gas, which develops a leak during transport shall promptly be removed to an isolated open place away from any source of ignition and the person responsible for transportation shall immediately contact the filler or the consignor, as the case may be, for necessary advice.",
"footnote": "",
"is_definition": false,
"sort_order": 82
}
],
"metadata": {
"Act ID": "11/595",
"Act Number": "Published vide G.S.R. 627(E), dated 21.9.2004, published vide Notification Gazette of India, Extraordinary, Part 2, Section 3(i), dated 21.9.2004.",
"Enactment Date": "",
"Act Year": "2004",
"Short Title": "The Gas Cylinders Rules, 2004",
"Type": "CENTRAL",
"Location": "India (Central)"
},
"updated_at": "2026-09-29 21:55:17"
}