2. Size of communicating pipe.

Floor area in Sq. Meter
Size of communicating pipe
From
To
1
100 ⅜"
or
10 mm i/d
Internal diameter
101
200 ½"
or
15 mm i/d
Ditto
201
500 ¾"
or
20 mm i/d
Ditto
501
1000 1"
or
25 mm i/d
Ditto
1000
1800 1¼"
or
30 mm i/d
Ditto
1800
3000 1½"
or
40 mm i/d
Ditto
(b) The size of the communicating pipe shall be based on its capacity of discharging a quantity adequate to the requirement of the house, or premises, for domestic and flusing purpose, at the plinth or entrance of the house or premises taking into consideration the length of the communication and service pipe the period of supply and the pressure head available in the city supply main.