160. Velocity of air current.

Degree of gassiness
Degree of gassiness
Place where velocity of air is to be measured
Place where velocity of air is to be measured
Velocity of air
Velocity of air
(1)
(1)
(2)
(2)
(3)
(3)
First, second or third degree
Immediate outbye ventilation connection from the
face.
30
First or second degree
(i) 4.5 meters from
any face whether working or discontinued on the intake side of
the brattice or partition.
(ii) 7.5 meters
outbye of the discharge end of an air pipe.
(iii) At the maximum span of a longwall face.
30
15
60
Third degree
(i) 4.5 meters from
any face whether working or discontinued on the intake side of
the brattice or partition.
(ii) 7.5 meters
outbye of the discharge end of an air pipe.
(iii) At the maximum span of a longwall face:
45
25
75