    "act_title": "The Coal Mines Regulations, 2017",
    "act_slug": "the-coal-mines-regulations-2017",
    "section_label": "Section",
    "section": {
        "number": "160",
        "title": "160. Velocity of air current.",
        "chapter": null,
        "content": "Degree of gassiness\nDegree of gassiness\nPlace where velocity of air is to be measured\nPlace where velocity of air is to be measured\nVelocity of air\nVelocity of air\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\nFirst, second or third degree\nImmediate outbye ventilation connection from the\n\t\t\t\tface.\n30\nFirst or second degree\n(i) 4.5 meters from\n\t\t\t\tany face whether working or discontinued on the intake side of\n\t\t\t\tthe brattice or partition.\n(ii) 7.5 meters\n\t\t\t\toutbye of the discharge end of an air pipe.\n(iii) At the maximum span of a longwall face.\n30\n15\n60\nThird degree\n(i) 4.5 meters from\n\t\t\t\tany face whether working or discontinued on the intake side of\n\t\t\t\tthe brattice or partition.\n(ii) 7.5 meters\n\t\t\t\toutbye of the discharge end of an air pipe.\n(iii) At the maximum span of a longwall face:\n45\n25\n75",
        "footnote": "",
        "is_definition": false,
        "sort_order": 159
    },
    "prev_section": "159",
    "next_section": "161"
}