156. Installation and maintenance of mechanical ventilator.

(i) in every main intake and return airway of every seam or section, as near as practicable to the entrance to the mine;
(ii) in every split, as near as practicable to the point at which the split commences;
(iii) in every ventilating district, as near as practicable to the point where the air is sub-divided at the end of a split and also where it enters the first working place; and
(iv) any other point that the Regional Inspector may, by an order in writing, specify,
(b) The measurements referred to in clause (a) shall be entered in a bound paged book kept for the purpose: