    "act_title": "The Coal Mines Regulations, 2017",
    "act_slug": "the-coal-mines-regulations-2017",
    "section_label": "Section",
    "section": {
        "number": "156",
        "title": "156. Installation and maintenance of mechanical ventilator.",
        "chapter": null,
        "content": "(i) in every main intake and return airway of every seam or section, as near as practicable to the entrance to the mine;\n(ii) in every split, as near as practicable to the point at which the split commences;\n(iii) in every ventilating district, as near as practicable to the point where the air is sub-divided at the end of a split and also where it enters the first working place; and\n(iv) any other point that the Regional Inspector may, by an order in writing, specify,\n(b) The measurements referred to in clause (a) shall be entered in a bound paged book kept for the purpose:",
        "footnote": "",
        "is_definition": false,
        "sort_order": 155
    },
    "prev_section": "155",
    "next_section": "157"
}