← Back to The Bombay Lifts Rules, 1958

7. Lift-cars.

[(b) Glass shall not be used in a lift-car except for the following purposes, namely :-
(i) covers for certificates,
(ii) lighting fixtures,
(iii) appliances used in connection with the operation of the car,
(iv) for vision panels and mirrors.
(b-i) Where the Inspector of Lifts is satisfied that glass to be used is for a capsule-type lift-car and it is specially designed for fire-resistance and is of fully transparent limanated type, he may relax the provisions of clause (b), subject to such conditions as he may specify;]
(c) Every lift shall be provided with an alarm signal operated by a push button which shall be fixed in a conspicuous position in the lift-car and clearly marked. The alarm shall be wired from electric mains other than the lift mains and shall be clearly audible outside the lift-well in order to obtain assistance in case of a break-down or failure between the floors.
(d) Every lift installation controlled by an operator shall be operated by a removable handle or key which shall remain at all times in the possession of the operator. The handle or key shall automatically return to the off position and lock there automatically when pressure is removed.
(e) Every lift-car should be provided with a light to give sufficient illumination on the floor and such light shall be left burning during the whole time the lift is available for use. Such light shall be on a circuit independent of the lift circuits and the controlling switch for the light shall be in the machine room close to the main switch for the machine.
(f) The approach to the landing gate on each floor shall be kept lighted during the whole time the lift is available for use at night, and during the day time, if so required by the Inspector of Lifts.
(g) Lift-cars having solid enclosure and doors and lift-cars installed in totally enclosed lift-wells shall be provided with adequate ventilation by means of an electric fan which shall be connected on electric mains other than the lift mains and shall always be maintained in working condition.
(h) A door or gate shall be provided at each entrance of the lift-car. Such doors or gates shall guard the full height and width of the lift-car opening and shall be sufficiently strong to withstand a thrust of [34 kg.] applied normally at any point without permanent deformation and without their being sprung from their guides. Where gates are used they shall be of close picket type and no openings exceeding [6 cm.] in width shall be permitted between the verticals when the gate is fully extended.
(i) Each door or gate shall be provided with an electric switch which shall prevent the lift-car from being started or kept in motion unless the door or gate is properly closed. Such switches shall be opened positively when the door or gate is opened.
Note. - This requirement prohibits the practice of short circuiting the lift-car door or gate switch to enable an unoccupied lift-car of an automatically operated lift to be called at a landing with the lift-car door or gate open.
Note.
(j) [* * *]
(k) [* * *]
(l) Lift-car platforms shall be of framed construction and shall be designed on the basis of contract load evenly distributed. Platforms for goods car shall be designed to suit the particular conditions of loading. The minimum factor of safety shall be 5 for steel and 8 for timber.
(m) Every lift-car shall be provided with an emergency exit which shall be fitted into the roof of the car in case where one lift operates in the lift-well or where more than one lift is installed in a lift-well, it shall be provided in the side adjacent to the adjoining lift-car. Where conditions will not allow the provision of an emergency exit, the safety-gear shall be of a type that can be released by hoisting up the lift-car.
(n) Top exits shall open outwards and shall be clear of all gear or equipment mounted on top of the lift-car.
(o) All emergency exit doors or panels shall be provided with an electric switch to prevent the lift from being operated when doors or panels are opened or removed.
(p) A plug socket shall be provided on top of the lift-car for a hand-lamp for use by persons working thereon.
(q) When lift-car levelling devices are used, aprons shall be fitted to the car-floor to ensure that no space is permitted between the threshold and the landing whilst the lift-car is being levelled to a floor.
[(r) For the lifts in buildings having height of more than 24 metres,-
(i) Lift-car for fire lift shall have floor area of not less than 1.4 square metres. It shall also have loading capacity of not less than 545 kgs. (3 persons);
(ii) lift car door shall have fire resistance of one hour;
(iii) lift-car for fire lift shall have power operated automatic closing and opening doors synchronised with landing doors while at landing level :]