← Back to The Bombay Lifts Rules, 1958

16. Overspeed Governor.

(b) The governor shall be placed where it is easily accessible and where it cannot be struck by the lift-car in case of over travel and where there is sufficient space for the full movement or the governor parts.
(c) Governor ropes shall be not less than [8 mm.] inches in diameter and shall be of steel or phosphor bronze and of suitable construction.
(d) The arc of contact made by the governor rope and the governor sheave shall, in conjunction with the rope tension device, provide sufficient tractive effort to cause proper operation of the governor.
(e) Governor ropes shall run clear of the governor jaws during the normal operation of the lift.
(f) Governor jaws and their mountings shall be so designed that any cutting, tearing or deformation of the rope resulting from their application shall not prevent proper operation of the safety gear.
(g) The motor control circuit and the brake control circuit shall be opened before the governor trips.
[(h) Governors for car safety gears shall be adjusted to actuate the safety gear at the following speed
(i) For rated speed of 1 meter per second or less, governor tripping speed shall be 140 per cent, of the rated speed or 0.88 meter per second, whichever is higher. For the rated speed of above 1 meter per second, the maximum governor tripping speed shall be 115 per cent, of the rated speed plus 0.25 meter per second.
(ii) The minimum governor tripping speed shall be 115 per cent, of the rated speed.]