Sl. No.
Sl. No.
Description
Description
Category of industries
Category of industries
Cottage Industries
Cottage Industries
Green & Orange industries
Green & Orange industries
Red industries (Special & Hazardous)
Red industries (Special & Hazardous)
A.
Minimum road width
7m.
7m.
7m.
B.
Maximum Height
18.30m.
18.30m
18.30m.
C.
Normally Permissible FSI
1.50
1.50
1.50
D.
Minimum Setback
Where Street
Alignment/new road is prescribed, it shall be from that street
alignment/new road line. In the case of others, it shall be from
the property boundary.
(i)
Front Setback
Abutting road width
Front Setback
6.0m
6.0m
less than 9m
1.5m
9m. to 18m.
3.0m.
18m. to 30.50m.
4.5m
More than 30.5m.
6.0m.
(ii)
Side Setback
1.50m.
3.0m.
6.0m.
(iii)
Rear Setback
Nil
2.0m.
6.0m.
E.
Structures
permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the rule 28
In addition, incidental structures such as Gate
pillars, servant room, watch man booth, cycle stand and toilets
with height not exceeding 4m are permissible in these minimum
prescribed setback spaces.
F.
Parking spaces shall be provided within the site
conforming to standards prescribed in the Annexure - IV.
G.
Rainwater harvesting provisions as prescribed in
the Annexure - XXII.
H.
The reservation of Land for Community
recreational purpose such as park or play ground required in
these regulations shall be as given in the rule 41.
Note. - The maximum height of the building shall not exceed 18.30 meters provided water tanks, chimneys, Architectural features such as flag masts, gopurams, minarets, steeples and other ornamental structures which are not intended for human habitation may be permitted subject to a ceiling of 30.5 meters from ground level. In case total height exceeds, 30.50 m from Ground level necessary NOC from Airport Authority of India (AAI) shall be furnished.
Note.
Section 36 • Tamil Nadu Combined Development and Building Rules, 2019
36. Planning Parameters of Industries.
tamil-nadu-combined-development-and-building-rules-2019-sec-36.json
•
Section 36
{
"act_title": "Tamil Nadu Combined Development and Building Rules, 2019",
"act_slug": "tamil-nadu-combined-development-and-building-rules-2019",
"section_label": "Section",
"section": {
"number": "36",
"title": "36. Planning Parameters of Industries.",
"chapter": null,
"content": "Sl. No.\nSl. No.\nDescription\nDescription\nCategory of industries\nCategory of industries\nCottage Industries\nCottage Industries\nGreen & Orange industries\nGreen & Orange industries\nRed industries (Special & Hazardous)\nRed industries (Special & Hazardous)\nA.\nMinimum road width\n7m.\n7m.\n7m.\nB.\nMaximum Height\n18.30m.\n18.30m\n18.30m.\nC.\nNormally Permissible FSI\n1.50\n1.50\n1.50\nD.\nMinimum Setback\nWhere Street\n\t\t\t\tAlignment/new road is prescribed, it shall be from that street\n\t\t\t\talignment/new road line. In the case of others, it shall be from\n\t\t\t\tthe property boundary.\n(i)\nFront Setback\nAbutting road width\nFront Setback\n6.0m\n6.0m\nless than 9m\n1.5m\n9m. to 18m.\n3.0m.\n18m. to 30.50m.\n4.5m\nMore than 30.5m.\n6.0m.\n(ii)\nSide Setback\n1.50m.\n3.0m.\n6.0m.\n(iii)\nRear Setback\nNil\n2.0m.\n6.0m.\nE.\nStructures\n\t\t\t\tpermissible in the minimum prescribed Front set back, Side\n\t\t\t\tsetback and Rear set back are given in the rule 28\nIn addition, incidental structures such as Gate\n\t\t\t\tpillars, servant room, watch man booth, cycle stand and toilets\n\t\t\t\twith height not exceeding 4m are permissible in these minimum\n\t\t\t\tprescribed setback spaces.\nF.\nParking spaces shall be provided within the site\n\t\t\t\tconforming to standards prescribed in the Annexure - IV.\nG.\nRainwater harvesting provisions as prescribed in\n\t\t\t\tthe Annexure - XXII.\nH.\nThe reservation of Land for Community\n\t\t\t\trecreational purpose such as park or play ground required in\n\t\t\t\tthese regulations shall be as given in the rule 41.\nNote. - The maximum height of the building shall not exceed 18.30 meters provided water tanks, chimneys, Architectural features such as flag masts, gopurams, minarets, steeples and other ornamental structures which are not intended for human habitation may be permitted subject to a ceiling of 30.5 meters from ground level. In case total height exceeds, 30.50 m from Ground level necessary NOC from Airport Authority of India (AAI) shall be furnished.\nNote.",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
"prev_section": "35",
"next_section": "37"
}