(a) the area so saved is transferred to the central area/space or court yard;
(b) the minimum open space on sides and rear except front, shall be
1.5 m for building height upto 12 m,
2.0 m for building height upto 15 m,
3.0 m for building height upto 18 m,
6 m in case of high rise buildings 21 m height and buildings coming under purview of AP Fire Act and 7 m in respect of buildings 21m - 30 m height. Such high rise buildings and buildings coming under purview of AP Fire Act need to obtain prior clearance from the Fire Services Department;
(c) the depth of such courtyard shall be at least 50% of the average building depth.
Section 8 • Revised Building Rules, 2007
8. Encouragement for Buildings With Central Courtyards.
revised-building-rules-2007-sec-8.json
•
Section 8
{
"act_title": "Revised Building Rules, 2007",
"act_slug": "revised-building-rules-2007",
"section_label": "Section",
"section": {
"number": "8",
"title": "8. Encouragement for Buildings With Central Courtyards.",
"chapter": null,
"content": "(a) the area so saved is transferred to the central area/space or court yard;\n(b) the minimum open space on sides and rear except front, shall be\n1.5 m for building height upto 12 m,\n2.0 m for building height upto 15 m,\n3.0 m for building height upto 18 m,\n6 m in case of high rise buildings 21 m height and buildings coming under purview of AP Fire Act and 7 m in respect of buildings 21m - 30 m height. Such high rise buildings and buildings coming under purview of AP Fire Act need to obtain prior clearance from the Fire Services Department;\n(c) the depth of such courtyard shall be at least 50% of the average building depth.",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
"prev_section": "6",
"next_section": "9"
}