    "act_title": "Revised Building Rules, 2007",
    "act_slug": "revised-building-rules-2007",
    "section_label": "Section",
    "section": {
        "number": "8",
        "title": "8. Encouragement for Buildings With Central Courtyards.",
        "chapter": null,
        "content": "(a) the area so saved is transferred to the central area/space or court yard;\n(b) the minimum open space on sides and rear except front, shall be\n1.5 m for building height upto 12 m,\n2.0 m for building height upto 15 m,\n3.0 m for building height upto 18 m,\n6 m in case of high rise buildings 21 m height and buildings coming under purview of AP Fire Act and 7 m in respect of buildings 21m - 30 m height. Such high rise buildings and buildings coming under purview of AP Fire Act need to obtain prior clearance from the Fire Services Department;\n(c) the depth of such courtyard shall be at least 50% of the average building depth.",
        "footnote": "",
        "is_definition": false,
        "sort_order": 5
    },
    "prev_section": "6",
    "next_section": "9"
}