(1) Planning authority to delineate "Form Based Zoning Districts" within the Master / Zonal Plan for special consideration of planning with integrated Public spaces;
(2) Form Based Zoning Districts (FBCs) to be formulated for each such Form Based Zoning Districts (FBZDs) with Single or Multiple Regulating Plans as necessary to cover the entire delineated special area;
(3) Space Use matrix along with Form Based Codes (FBC) development standards, for each Form Based Zoning District (FBZD) as formulated in the Form Based Codes (FBC) are to be used for site layouts and building designs for all types of buildings; and
(4) Form Based Codes (FBC) standards of flexible and adaptive designs shall be superseding, overriding all stipulations from rule 19 to rule 25 of these rules for all types of buildings in the respective Form Based Zoning Districts (FBZDs).
19. (A) Residential.
Table 4: Residential Plots/ Villas; (Except
Affordable and Economical Weaker Section Housing)
Table 4: Residential Plots/ Villas; (Except
Affordable and Economical Weaker Section Housing)
S.No.
S.No.
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
I.
Minimum Approach Road
Minimum Approach Road
12 meters
II.
II.
Minimum Plot Size
Minimum Plot Size
60 sq.m
III.
III.
Maximum Ground Coverage
Maximum Ground Coverage
For first 150 sq.m of plot area
70%
For the next 100 sq.m of plot area
65%
For the next 100 sq.m of plot area
60%
For the next 100 sq.m of plot area
50%
For the next remaining area of plot
40%
IV.
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:2.1
V.
V.
Maximum No. of Floors
Maximum No. of Floors
Ground +2 Floors (excluding basement)
VI.
VI.
Maximum Height of Building
Maximum Height of Building
11 meters
VII.
VII.
Setbacks around building
Setbacks around building
Front & Rear setback
1/4th of the height of the building or 2 m,
whichever is more
Side setback, if left at any point of the
building
1/5th of the height of building or 1.5 m whichever is more
VIII.
VIII.
Parking
Parking
Plot area
Plot area
Parking Required
Parking Required
Upto 100 Sq.m
2 No.'s Two wheeler parking space
Above 100 to 250 Sq.m
1 Car & 2 nos. Two wheelers
Above 250 to 500 Sq.m
2 Car & 2 nos. Two wheelers
Above 500 Sq.m
3 Car & 2 nos. Two wheelers
Notes. - (a) The area of the basement should not be more than the ground coverage subject to the safety of adjoining property from all aspects and as per the provision of part V of these rules.
Notes.
(b) Basement, if constructed, may be used for parking, household storage, habitable and consultancy services purposes. It shall be counted towards Floor Area Ratio if used for habitable purposes.
(c) Front boundary wall shall be optional for providing easy access for parking in front setback within plot area for which approval from the Competent Authority concerned shall be obtained.
(d) No opening is allowed on party wall of properties.
(e) The maximum permissible ground coverage and Floor Area Ratio is subjected to the fulfilment of the setback, height and parking norms.
[(f) In small size plot upto 105 sq.m (125 sq.yd) area, front setback may be relaxed upto 1.5m irrespective of building height.]
Table 5:
Residential Independent Floors
Table 5:
Residential Independent Floors
S.No
S.No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Approach Road
Minimum Approach Road
12m
II.
Maximum Ground Coverage
Maximum Ground Coverage
For first 250 sq.mt.
65%
For the next 100 sq. m
60%
For the next 100 sq. m
50%
For the next remaining area
40%
III.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
For first 250 sq.mt.
1:2.6
For the next 100 sq. m
1:2.4
For the next 100 sq. m
1:2.0
For the next remaining area
1:1.6
IV.
Maximum No. of Floors
Maximum No. of Floors
Stilt +4 Floors
V.
Maximum Height of Building
Maximum Height of Building
Below 15 m
Note: Excluding mumty, parapet, and architectural
features. The stilts shall be compulsory and shall be counted
towards height of the building.
Note:
VI.
Setbacks around buildings
Setbacks around buildings
Front setback
1/5th of the height of the building or 2 m whichever is more
Rear setback
1/5th of the height of the building or 2 m whichever is more
Side setback, if left at any point of building,
1/5th of the height of the the building or 1.5 m whichever is
more
VII.
Parking
Parking
Dwelling Unit (DU) Size
Dwelling Unit (DU) Size
Equivalent Car Space required (ECS) per DU
Equivalent Car Space required (ECS) per DU
Unit Area upto 120 sq.m.
1.5
Unit Area above 120 sq.m upto 300 sq.m.
2.0
Unit Area Above 300 sq.m.
3.0
Notes. - (a) In case of Independent floors, plots shall be in a block of row housing and earmarked for independent floors in the Layout Plan or Zoning Plan.
Notes.
(b) No individual plot in any block which is not earmarked in the Layout Plan or Zoning Plan for independent floors shall be allowed to be constructed as an independent floor unless the building is detached having minimum plot area 800 square meters.
(c) The parking required in case of independent floors shall compulsorily be under stilts. However, in case of an independent plot having minimum area of 800 square meters used for independent floors, the parking under stilts shall be optional, provided that the promoter provides surface/ basement parking as per norms within the plot.
(d) In case of independent floor, common staircase or common elevator is permissible maximum for two plots subject to the condition that the minimum clear width of staircases shall be 1350 mm.
Table 6:
Group Housing / Studio Apartments
Table 6:
Group Housing / Studio Apartments
S.No
S.No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Site area
Minimum Site area
Studio Apartment
2000 sq.m
Group Housing
As per the Provisions of Master Plan
II.
Minimum Approach Road
Minimum Approach Road
18m
III.
Maximum Ground Coverage
Maximum Ground Coverage
30% of Site Area
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Minimum approach road 18 m
1:2.0
Minimum approach road 24 m
1:2.5
Minimum approach road 30 m
1:3.0
Minimum approach road 45 m & above
Unlimited*
V.
Maximum Height of Building
Maximum Height of Building
No Restriction Subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of rule of these building rules.
VII.
Parking Group Housing
Parking Group Housing
Dwelling Unit (D/U) Size
Equivalent Car Space required (ECS) per D/U
D/U Area upto 90 sq.m.
1.0
D/U Area above 90 sq.m upto 120 sq.m.
1.5
D/U Area above 120 sq.m upto 300 sq.m.
2.0
D/U Area Above 300 sq.m.
3.0
Additional 10 percent guest parking shall also be provided.
Studio Apartments
Studio
Apartments
[Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
Notes. - (a) In case of studio apartment, the maximum size of the unit shall be 50 sq.m.
Notes.
(b) In case of Group Housing/apartments, minimum 25% of site area shall be kept as green in which 15% of site area shall be in the form organized park/ playground with minimum width of 15m. If the width of the green space is less than 15 m, then it shall not be counted in the area of organized park/ playground.
(c) In case of Group Housing/apartments, Economical Weaker Section (E.W.S) housing shall be provided as per the government policy dated 24.05.2016 as amended from time to time.
(d) The F.A.R above 1:2 in case of Group Housing will be chargeable on prorata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
(e) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around the building, parking norms, light and ventilation, height, fire and structural safety.
(f) Upto 1.0 percent of the total covered area of group housing project shall be allowable for convenient shopping such as grocery shop, vegetable shop, laundry and dry cleaning, medical store, confectionery, bakery, hair cutting saloon, stationery shop, milk booth excluding Club Building.
(g) access to commercial building in group housing may be allowed from external road subject to the fulfilment of parking, setback and road width etc.
(h) The Net Residential Density shall be permissible as per the provisions of the respective Master Plans, government notifications as amended from time to time whichever is applicable.
[***]
Notes. - (a) Rental housing/Hostel building shall be a detached building.
Notes.
(b) It shall provide kitchen with dining hall, common room for indoor games, first aid room, laundry, security guard room.
(c) In Rental housing, upto 2% of the Floor Area Ratio. availed may be used for canteen, coffee shop, library, ATM, Grocery shop, Pharmacy, office, Mobile shop, Fruit/Vegetable shop, Barber shop or other similar activities for self use of the Users.
(d) Basement shall be permissible as per sub-rule (6) of rule 31.
(e) The provisions laid down in the rental housing policy shall be read with building bye laws concurrently.
(B) Other general control for residential buildings. - (i) For calculation of infrastructure required for the project, the population of villa shall be counted @ 5 persons per villa and plotted development shall be counted @ 15 persons per plot, whereas in case of Independent floors having S+4 or G+3 it shall be @ 20 persons per plot and for group housing it shall be @ 5 persons per Dwelling Unit. where basement is used for habitable purpose then the density of five person per basement shall be added to the permissible density of the plot.
(B) Other general control for residential buildings.
(ii) Floating population shall be taken as minimum 100 person per acre for calculation of infrastructural/ services requirements only and shall not be counted towards the regular density of the project/ sector.
(iii) The population density of Studio Apartments shall be counted as two persons per unit.
(iv) The Population density of Rental housing shall be counted as one person per 12.5 sq.m of total covered area of the building or as per actual whichever is more.
(v) The density for each category of flats in case of Group Housing/Apartment/ Studio Apartments shall be calculated separately. The promoter has to clearly indicate the area under each category of flats.
(vi) The clubbing of two or more plots or plots earmarked for independent floors in row housing may be allowed. The promoter or owner has to get a revised Zoning Plan approved from the Competent Authority.
(vii) In case of residential plot, it is mandatory to provide indigenous or fruit tree in the premises of plot as per criteria described in Part XI of these rules.
(viii) In case of Low Density Country Homes Residential, Economical Weaker Section housing, Affordable housing, housing for all, Pardhan Mantri Awas Yojna (PMAY), Punjab Shehri Awas Yojana (PSAY) and any other policy relating to housing issued by State or Central Government, the physical and development norms as prescribed in the said policy as amended from time to time shall be applicable.
(ix) Professional activity shall be allowed in residential plot and flats on any floor on the following condition:
Part of the premises shall be permitted to be used upto a maximum of 25 % of FAR or 100 sq.m, whichever is less, for non-nuisance / non service / non-teaching/ non-commercial/ non trading activities for rendering consulting based on professional skills such as charted accountant, architect, planner, advocates, doctors (only consultancy) or other similar activities.
20. (A) Commercial.
Table 8:
Convenient Shopping / Neighbourhood Shopping Plotted within
approved layout plan.
Table 8:
Convenient Shopping / Neighbourhood Shopping Plotted within
approved layout plan.
S. No.
S. No.
Parameter
Parameter
Permissible Limits
Permissible Limits
Category
Category
Booths
Booths
Shops/ shop cum offices
Shops/ shop cum offices
Shops/ shop cum offices
Shops/ shop cum offices
I.
Width of plot
Width of plot
Upto 3m
Above 3m to 5m
Above 5m
II.
Minimum Approach Road
Minimum Approach Road
18m
24m
III.
Maximum Ground Coverage
Maximum Ground Coverage
100% of plot area
Depth of Plot
% of plot area
Depth of Plot
% of plot area
upto 12m
100
upto 12m
100
more than 12m
80
more than 12m
75
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1
1:2
1:3
V.
No. of Stories
No. of Stories
1
2
4
Note: Excluding mumty, parapet, lift room and
architectural features
VI.
Minimum width of corridor/Canopy/Projection
etc. for weather protection
Minimum width of corridor/Canopy/Projection
etc. for weather protection
2.2m
2.5m
2.5m
VII.
Parking
Parking
2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
Notes. - (a) The plotted Convenient Shopping / Neighbourhood Shopping development shall be permissible on 18m (60'-0") wide road subject to the condition that the maximum area of the site shall not be more than 8000 sq.mt. The minimum approach road for area more than 8000 sq. mt. shall be 24m(80'-0").
Notes.
(b) The F.A.R above 1:1.75 in case of commercial building, will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
(c) In case of commercial plot having openings on both front and rear, then the ground coverage to be permitted in such cases shall be upto 100% of the plot area carved out shops, shop-cum-shop/offices, shop-cum-flat etc. subject to the conditions that corridors of appropriate width, as specified in Table 8 above shall be provided in front of each opening. The basement shall be restricted under the building excluding the area under corridors. Floor Area Ratio, height, number of storeys, clear width of the corridor shall be governed by the width of the plot and stipulation made under these rules. However, the total coverage shall continue to be governed by the parking requirements mentioned as per Table 8 with adequate provision made both in front and rear of the site.
[(d) Approach to upper floors in case of double storeyed shops, shop-cum- offices/ shops can also be permitted from the public corridor.]
(e) Approach to basement floors shall be permitted only from within the booth/ shops/shop-cum-shop/offices.
(f) Height of booths/ Shops/ shop cum offices shall be governed by control sheets/zoning plan.
(g) In case of SCO, common staircase or common elevator is permissible maximum for two SCO subject to the condition that the minimum clear width of staircases shall be 1500 mm.
(h) All Government commercial site planned for retail outlet shall be governed by approved layout plan/ zoning plan / standard architectural control sheets prepared by the development authorities concerned.
Table 9: Commercials such as Shopping Mall /
Shopping Complex or a building primarily used for display and
sale of merchandise or any similar purpose
Table 9: Commercials such as Shopping Mall /
Shopping Complex or a building primarily used for display and
sale of merchandise or any similar purpose
S.No
S.No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Approach Road
Minimum Approach Road
24m
II.
Minimum Frontage
Minimum Frontage
20m
III.
Maximum Ground Coverage
Maximum Ground Coverage
45% of Plot Area
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Minimum approach road 24 m
1:2.5
Minimum approach road 30 m
1:3.0
Minimum approach road 45 m & above
Unlimited*
V.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
sub-rule (1) of rule 26
VII.
Parking
Parking
2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
Notes. - (a) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.
Notes.
(b) F.A.R above 1:1.75, will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
Table 10:
Miniplex
Table 10:
Miniplex
S.No
S.No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Approach Road & Site Area
Minimum Approach Road & Site Area
plot size from 2000 sq.m and below 4000 sq.m
18 m
plot size 4000 and above sq.m
24 m
II.
Minimum Frontage
Minimum Frontage
24 m
III.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Minimum approach road width 18 m
1:2.0
Minimum approach road width 30 m and above
1:2.5
V.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
sub-rule (1) of rule 26
VII.
Parking
Parking
3.0 Equivalent Car Space per 100 square meters of the covered
area in respect of miniplex or cinema component and 2 Equivalent
Car Space per 100 square meters of the balance covered area.
Notes. - (a) F.A.R above 1:1.75, will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
Notes.
(b) In case any provision is not specified /covered under these rules then the physical and development norms as specified in the miniplex policy or the Punjab Cinemas (Regulation) Act, 1952, as the case may be shall be applicable.
(c) In case of Miniplex or Cinema the physical and development norms as specified in the miniplex policy or the Punjab Cinemas (Regulation) Act, 1952, as the case may be, shall be applicable, however, for the provision not specified /covered under above policies, these rules shall be applicable.
(d) Commercial component such as retail, shopping restaurant, food courts etc. are permissible in miniplex.
Table 11:
Multiplex
Table 11:
Multiplex
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum plot size
Minimum plot size
4000 sq.m
II.
Minimum Approach Road
Minimum Approach Road
24 m
III.
Minimum Frontage
Minimum Frontage
30 m
IV.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
V.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Minimum approach road 24 m
1:2.0
Minimum approach road 30 m
1:2.5
Minimum approach road 45 m and above
Unlimited*
VI.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
VII.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
sub-rule (1) of rule 26
VIII.
Parking
Parking
3.0 Equivalent Car Space per 100 square meters of the covered
area in respect of multiplex or cinema component plus 30 percent
of the total covered area of that component i.e (multiplex or
cinema component) and 2 Equivalent Car Space per 100 square
meters of the balance covered area.
Notes. - (a) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.
Notes.
(b) The F.A.R above 1:1.75 , will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
(c) In case of Multiplex or Cinema the physical and development norms as specified in the multiplex policy or the Punjab Cinemas (Regulation) Act, 1952, as amended from time to time, shall be applicable, however, for any provision not specified /covered under above policies, these rules shall be applicable.
(d) In case any provision is not specified /covered under these rules then the physical and development norms as specified in the multiplex policy or the
(e) Commercial component such as retail, shopping restaurant, food courts etc. are permissible in multiplex.
Table 12:
Hotel or Motel
Table 12:
Hotel or Motel
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Approach Road
Minimum Approach Road
Plot size from 1000 sq.yd upto 2000 sq.yd
12m
Plot size above 2000 sq.yd upto 4000 sq.yd
18m
Plot size above 4000 sq.yd
24m
Note: In rural areas outside Master Plans, the Hotel activity
upto one acre area shall be permissible on link roads having
minimum width of 22'-0" (4 karam). However, the developer
has to widen the road to minimum 40 feet or as specified in the
Master Plan whichever is more, by leaving proportionate area from
his own land.
II.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
III.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
For plot size 1000 sq.yd upto 2000 sq.yd
1:2.0
For plot size above 2000 sq.yd upto 4000 sq.yd
1:2.5
For plot size above 4000 sq.yd
Unlimited*
IV.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
V.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
sub-rule (1) of rule 26
VI.
Parking
Parking
2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
Notes. - (a) Commercial use within the Hotel Building envelope shall be permissible as per the policy of State Government, as amended from time to time.
Notes.
(b) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.
(c) F.A.R above 1:3, will be chargeable on pro-rata basis. However for sites allotted or sold by the development authority, the charges shall be applicable as per the terms and conditions of the allotment letter.
Table 13:
Club
Table 13:
Club
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Approach Road
Minimum Approach Road
Plot size from 1000 sq.m upto 2000 sq.m
18m (60'-0")
Plot size above 2000 sq.m
24m (80'-0")
II.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
III.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1.0
IV.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport
Authority and fulfilment of norms such as setbacks around
building, ground coverage, F.A.R., structural safety and fire
safety norms.
V.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these
building rules.
sub-rule (1) of rule 26
VI.
Parking
Parking
3 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
Table 14:
Guest House/Lodging & Boarding/Service Apartments
Table 14:
Guest House/Lodging & Boarding/Service Apartments
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Site area
Minimum Site area
1000 sq.m
II.
Minimum Approach Road
Minimum Approach Road
Plot size from 1000 sq.m upto 2000 sq.m
12m(40'-0")
Plot size above 2000 sq.m
18m (60'-0")
III.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Plot size from 1000 sq.m upto 2000 sq.m
1:1.0
Plot size above 2000 sq.m
1:2.0
V.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
VII.
Parking
Parking
1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
Table 15:
Dhaba
Table 15:
Dhaba
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Site area
Site area
Minimum 1000 sq.m
II.
Minimum Approach Road
Minimum Approach Road
Plot size from 1000 sq.m upto 2000 sq.m
18m (60'-0")
Plot size above 2000 sq.m
24m (80'-0")
III.
Minimum Frontage
Minimum Frontage
20 m
IV.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
V.
Floor Area Ratio
Floor Area Ratio
1:0.5
VI.
Height
Height
6 m.
VII.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
VIII.
Parking
Parking
30% of plot area
Notes. - (a) Maximum 50 sq.mt. area for Kiosks like STD, books, cassettes etc. can be permissible as ancillary uses within F.A.R
Notes.
(b) The access permission is required from competent authority if the site is located on scheduled road / State Highway/National Highway.
(c) Approach from National Highways can be considered if the site fulfils minimum distance norm from intersection/access or abuts 7M wide service road or applicant submits prior permission of access from National Highway Authority of India (NHAI).
Table 16:
Wholesale Trade/ Integrated Freight complex (Standalone)
Table 16:
Wholesale Trade/ Integrated Freight complex (Standalone)
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Site area
Minimum Site area
1 Ha.
II.
Minimum Approach Road
Minimum Approach Road
24 m (80'-0")
III.
Minimum Frontage
Minimum Frontage
30 m
IV.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
V.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1.0
VI.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport
Authority and fulfilment of norms such as setbacks around
building, ground coverage, F.A.R., structural safety and fire
safety norms.
VII.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building
rules.
VIII.
Parking
Parking
2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
Note. - For Risk based approval of types of Warehouses / Integrated Freight complex (IFC) refer sub-rule (2) of rule 47.
Note.
Table 17: Warehouse / Godown (Standalone)
Table 17: Warehouse / Godown (Standalone)
S. No
S. No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Site area
Minimum Site area
2000 sq.m
II.
Minimum Approach Road
Minimum Approach Road
12 m (Minimum 22'-0" widen to 40'-0")
III.
Minimum Frontage
Minimum Frontage
30 m
IV.
Maximum Ground Coverage
Maximum Ground Coverage
40% of Plot Area
V.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1.0
VI.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport Authority and
fulfilment of norms such as setbacks around building, ground
coverage, F.A.R., structural safety and fire safety norms.
VII.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these building rules.
sub-rule (1) of rule 26
VIII.
Parking
Parking
2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] a.
Note. - For Risk based approval of types of Warehouses / Integrated Freight complex (IFC) refer sub-rule (2) of rule 47.
Note.
(B) Petrol pumps / Filling -cum-service stations. - Petrol Pump/ filling-cum-service stations/ two-three wheelers petrol pump shall be governed as per instructions/ guidelines of Indian Roads Congress (IRC)/ Ministry of Road Transport and Highways (MORTH)/ Town and Country Planning Organisation (TCPO)/ Department of Housing and Urban Development, Government of Punjab.
(B) Petrol pumps / Filling -cum-service stations.
21. (A) Industry.
[Table 18: Industry Plotted
[Table 18: Industry Plotted
Serial No.
Serial No.
Parameter
Parameter
Permissible Limits
Permissible Limits
1.
Minimum Approach Road
Minimum Approach Road
15m (Min. 16'-6" widen to 50'-0") or
as per master plan whichever is more
2.
Maximum Ground Coverage
Maximum Ground Coverage
65 % of the plot area**
3.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Unlimited*
4.
Maximum Height of Building
Maximum Height of Building
Below 15m
Note: Excluding equipment, machinery such as
chimney, boiler, plant, hammer, silos etc. irrespective of its
height.
5.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these rules.
6.
Parking
Parking
General Industry
1 Equivalent Car Space per 100 sq.m. of the
total floor area ratio.
Informational Technology
For Site Area upto 2 Acres : 1.0 Equivalent Car
Space per 100 sq.m. of the total floor area ratio.
For Site Area above 2 Acres: 2 Equivalent Car
Space per 100 sq.m. of the total floor area ratio.
Note. - (a) **5% additional ground coverage shall be permitted in case of retail service industry.
Note.
(b) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.
(c) In case of Industrial Estate/ Private Industrial Areas or Conglomeration of Industries opt for central parking then:
(i) Minimum 20% parking shall be within the premises of the industry.
(ii) The parking requirement if provided in mechanical/ common pool area shall be duly certified by the concerned association by whom it is being maintained.
(iii) The share of common parking shall be calculated as per the total area of the industrial plot duly certified by the concerned agency maintaining that parking.
(iv) In case any false claim regarding common parking is observed then the industrial plot holder has to provide parking in his own premises.] .
Table 19: General industry flatted
Table 19: General industry flatted
S.No
S.No
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Site area
Minimum Site area
2000 sq.mt.
II.
Minimum Approach Road
Minimum Approach Road
18m
III.
Maximum Ground Coverage
Maximum Ground Coverage
40 %
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Unlimited*
V.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport
Authority and fulfilment of norms such as setbacks around
building, ground coverage, F.A.R., structural safety and fire
safety norms.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these
building rules.
sub-rule (1) of rule 26
VII.
Parking
Parking
2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
Table 20: Information Technology flatted
Table 20: Information Technology flatted
S. No
S. No
Parameter
Parameter
Permissible Limits
I.
I.
Minimum Site area
Minimum Site area
As per I.T. policy
II.
II.
Minimum Approach Road
Minimum Approach Road
18m
III.
III.
Maximum Ground Coverage
Maximum Ground Coverage
40%
IV.
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
Unlimited*
V.
V.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from
Airport Authority and fulfilment of norms such as setbacks around
building, ground coverage, F.A.R., structural safety and fire
safety norms.
VI.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these
building rules.
sub-rule (1) of rule 26
VII.
VII.
Parking
Parking
Site Area upto 2 Acres
1.0 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
Site Area above 2 Acres
2.0 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
(B) Other controls for Industrial Buildings. - (i) For industrial plots more than 1000 sq.m, 10% of the total plot area shall be reserved as amenity open space. When such amenity open space exceeds 1500 sq.m, the excess area could be utilized for construction of buildings for banks, canteen, welfare centre and such other common purposes.
(B) Other controls for Industrial Buildings.
(ii) Upto 15 percent of the total covered area in industrial buildings shall be permissible for the housing of staff or workers.
(iii) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.
22. (A) Educational.
Table 21: Pre Nursery / Nursery School /
crèche
Table 21: Pre Nursery / Nursery School /
crèche
S. No.
S.
No.
Parameter
Parameter
Permissible Limits
I.
Minimum Site area
Minimum Site area
1000 sq.m
II.
Minimum Approach Road
Minimum Approach Road
12 m
III.
Maximum Ground Coverage
Maximum Ground Coverage
40% of site area
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1.0
V.
Setbacks around buildings
Setbacks around buildings
Front
6m or 1/3 of the height of the building,
whichever is more
Other side
4.5m or 1/3 of the height of the building,
whichever is more
VI.
Parking
Parking
1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
VII.
Maximum number of Floors
Maximum number of Floors
G+1
Note. - only ground floor shall be used for academics however first floor may be used for residential, office, storage etc.
Note.
Table 22: Primary school (class 1 to 5)
Table 22: Primary school (class 1 to 5)
S. No.
S. No.
Parameter
Parameter
Permissible Limits
Permissible Limits
I.
Minimum Site area
Minimum Site area
As per the norms of the affiliation authority
or 5000 sq mts whichever is more
II.
Minimum Approach Road
Minimum Approach Road
12m
III.
Maximum Ground Coverage
Maximum Ground Coverage
40% of site area
IV.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1.2
V.
Parking
Parking
1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]
VI.
Maximum Height of Building
Maximum Height of Building
below 15m
VII.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these
building rules.
sub-rule (1) of rule 26
Table 23: High/ Senior secondary school/
College or Educational Institute/Universities.
Table 23: High/ Senior secondary school/
College or Educational Institute/Universities.
S. No.
S. No.
Parameter
Parameter
Permissible Limits
I.
I.
Minimum Approach Road
Minimum Approach Road
for School
Within Master Plan
-18m (60'-0")
Outside Master Plan-12m (40'-0")
for College/university
Within Master Plan
-24m (80'-0")
Outside Master Plan-18m (60'-0")
II.
II.
Maximum Ground Coverage
Maximum Ground Coverage
40% of plot area
III.
III.
Maximum Floor Area Ratio
Maximum Floor Area Ratio
1:1.5
IV.
IV.
Parking
Parking
School, College
1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
University Campus
1.0 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .
V.
V.
Maximum Height of Building
Maximum Height of Building
No Restriction subject to clearance from Airport
Authority and fulfilment of norms such as setbacks around
building, ground coverage, F.A.R., structural safety and fire
safety norms.
VI.
VI.
Setbacks around buildings
Setbacks around buildings
Refer sub-rule (1) of rule 26 of these
building rules.
sub-rule (1) of rule 26
(B) Other controls for Educational Building(s). - (i) In case of new school area of 1 acre or above, the front boundary wall shall be recessed by 6m to accommodate visitors parking within setback area.
(B) Other controls for Educational Building(s).
(ii) Minimum 15% of site area shall be kept/developed as playground with minimum width of 15 m.
(iii) Upto 15 percent of the total covered area in educational buildings shall be permissible for the housing of staff or workers.
(iv) In case of large Campus/ Universities / Indian Institute of Technology (IIT) / Indian Institute of Management (IIM), upto 30% of the total covered area (F.A.R) can be utilized for residential use for essential staff and fellow accommodations by providing housing for staff, dormitories, guest houses or creche.
(v) Student Hostel shall not be count in residential component.
Section 18 • Punjab Urban Planning and Development Building Rules, 2018
18. Compliance to Special Area development and control as per Master Plan/ Zonal Plan.
punjab-urban-planning-and-development-building-rules-2018-sec-18.json
•
Section 18
{
"act_title": "Punjab Urban Planning and Development Building Rules, 2018",
"act_slug": "punjab-urban-planning-and-development-building-rules-2018",
"section_label": "Section",
"section": {
"number": "18",
"title": "18. Compliance to Special Area development and control as per Master Plan/ Zonal Plan.",
"chapter": null,
"content": "(1) Planning authority to delineate \"Form Based Zoning Districts\" within the Master / Zonal Plan for special consideration of planning with integrated Public spaces;\n(2) Form Based Zoning Districts (FBCs) to be formulated for each such Form Based Zoning Districts (FBZDs) with Single or Multiple Regulating Plans as necessary to cover the entire delineated special area;\n(3) Space Use matrix along with Form Based Codes (FBC) development standards, for each Form Based Zoning District (FBZD) as formulated in the Form Based Codes (FBC) are to be used for site layouts and building designs for all types of buildings; and\n(4) Form Based Codes (FBC) standards of flexible and adaptive designs shall be superseding, overriding all stipulations from rule 19 to rule 25 of these rules for all types of buildings in the respective Form Based Zoning Districts (FBZDs).\n19. (A) Residential.\nTable 4: Residential Plots/ Villas; (Except\n\t\t\t\tAffordable and Economical Weaker Section Housing)\nTable 4: Residential Plots/ Villas; (Except\n\t\t\t\tAffordable and Economical Weaker Section Housing)\nS.No.\nS.No.\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nI.\nMinimum Approach Road\nMinimum Approach Road\n12 meters\nII.\nII.\nMinimum Plot Size\nMinimum Plot Size\n60 sq.m\nIII.\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\nFor first 150 sq.m of plot area\n70%\nFor the next 100 sq.m of plot area\n65%\nFor the next 100 sq.m of plot area\n60%\nFor the next 100 sq.m of plot area\n50%\nFor the next remaining area of plot\n40%\nIV.\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:2.1\nV.\nV.\nMaximum No. of Floors\nMaximum No. of Floors\nGround +2 Floors (excluding basement)\nVI.\nVI.\nMaximum Height of Building\nMaximum Height of Building\n11 meters\nVII.\nVII.\nSetbacks around building\nSetbacks around building\nFront & Rear setback\n1/4th of the height of the building or 2 m,\n\t\t\t\twhichever is more\nSide setback, if left at any point of the\n\t\t\t\tbuilding\n1/5th of the height of building or 1.5 m whichever is more\nVIII.\nVIII.\nParking\nParking\nPlot area\nPlot area\nParking Required\nParking Required\nUpto 100 Sq.m\n2 No.'s Two wheeler parking space\nAbove 100 to 250 Sq.m\n1 Car & 2 nos. Two wheelers\nAbove 250 to 500 Sq.m\n2 Car & 2 nos. Two wheelers\nAbove 500 Sq.m\n3 Car & 2 nos. Two wheelers\nNotes. - (a) The area of the basement should not be more than the ground coverage subject to the safety of adjoining property from all aspects and as per the provision of part V of these rules.\nNotes.\n(b) Basement, if constructed, may be used for parking, household storage, habitable and consultancy services purposes. It shall be counted towards Floor Area Ratio if used for habitable purposes.\n(c) Front boundary wall shall be optional for providing easy access for parking in front setback within plot area for which approval from the Competent Authority concerned shall be obtained.\n(d) No opening is allowed on party wall of properties.\n(e) The maximum permissible ground coverage and Floor Area Ratio is subjected to the fulfilment of the setback, height and parking norms.\n[(f) In small size plot upto 105 sq.m (125 sq.yd) area, front setback may be relaxed upto 1.5m irrespective of building height.]\nTable 5:\n\t\t\t\tResidential Independent Floors\nTable 5:\n\t\t\t\tResidential Independent Floors\nS.No\nS.No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Approach Road\nMinimum Approach Road\n12m\nII.\nMaximum Ground Coverage\nMaximum Ground Coverage\nFor first 250 sq.mt.\n65%\nFor the next 100 sq. m\n60%\nFor the next 100 sq. m\n50%\nFor the next remaining area\n40%\nIII.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nFor first 250 sq.mt.\n1:2.6\nFor the next 100 sq. m\n1:2.4\nFor the next 100 sq. m\n1:2.0\nFor the next remaining area\n1:1.6\nIV.\nMaximum No. of Floors\nMaximum No. of Floors\nStilt +4 Floors\nV.\nMaximum Height of Building\nMaximum Height of Building\nBelow 15 m\nNote: Excluding mumty, parapet, and architectural\n\t\t\t\tfeatures. The stilts shall be compulsory and shall be counted\n\t\t\t\ttowards height of the building.\nNote:\nVI.\nSetbacks around buildings\nSetbacks around buildings\nFront setback\n1/5th of the height of the building or 2 m whichever is more\nRear setback\n1/5th of the height of the building or 2 m whichever is more\nSide setback, if left at any point of building,\n1/5th of the height of the the building or 1.5 m whichever is\n\t\t\t\tmore\nVII.\nParking\nParking\nDwelling Unit (DU) Size\nDwelling Unit (DU) Size\nEquivalent Car Space required (ECS) per DU\nEquivalent Car Space required (ECS) per DU\nUnit Area upto 120 sq.m.\n1.5\nUnit Area above 120 sq.m upto 300 sq.m.\n2.0\nUnit Area Above 300 sq.m.\n3.0\nNotes. - (a) In case of Independent floors, plots shall be in a block of row housing and earmarked for independent floors in the Layout Plan or Zoning Plan.\nNotes.\n(b) No individual plot in any block which is not earmarked in the Layout Plan or Zoning Plan for independent floors shall be allowed to be constructed as an independent floor unless the building is detached having minimum plot area 800 square meters.\n(c) The parking required in case of independent floors shall compulsorily be under stilts. However, in case of an independent plot having minimum area of 800 square meters used for independent floors, the parking under stilts shall be optional, provided that the promoter provides surface/ basement parking as per norms within the plot.\n(d) In case of independent floor, common staircase or common elevator is permissible maximum for two plots subject to the condition that the minimum clear width of staircases shall be 1350 mm.\nTable 6:\n\t\t\t\tGroup Housing / Studio Apartments\nTable 6:\n\t\t\t\tGroup Housing / Studio Apartments\nS.No\nS.No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\nStudio Apartment\n2000 sq.m\nGroup Housing\nAs per the Provisions of Master Plan\nII.\nMinimum Approach Road\nMinimum Approach Road\n18m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n30% of Site Area\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nMinimum approach road 18 m\n1:2.0\nMinimum approach road 24 m\n1:2.5\nMinimum approach road 30 m\n1:3.0\nMinimum approach road 45 m & above\nUnlimited*\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction Subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of rule of these building rules.\nVII.\nParking Group Housing\nParking Group Housing\nDwelling Unit (D/U) Size\nEquivalent Car Space required (ECS) per D/U\nD/U Area upto 90 sq.m.\n1.0\nD/U Area above 90 sq.m upto 120 sq.m.\n1.5\nD/U Area above 120 sq.m upto 300 sq.m.\n2.0\nD/U Area Above 300 sq.m.\n3.0\nAdditional 10 percent guest parking shall also be provided.\nStudio Apartments\nStudio\nApartments\n[Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\nNotes. - (a) In case of studio apartment, the maximum size of the unit shall be 50 sq.m.\nNotes.\n(b) In case of Group Housing/apartments, minimum 25% of site area shall be kept as green in which 15% of site area shall be in the form organized park/ playground with minimum width of 15m. If the width of the green space is less than 15 m, then it shall not be counted in the area of organized park/ playground.\n(c) In case of Group Housing/apartments, Economical Weaker Section (E.W.S) housing shall be provided as per the government policy dated 24.05.2016 as amended from time to time.\n(d) The F.A.R above 1:2 in case of Group Housing will be chargeable on prorata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.\n(e) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around the building, parking norms, light and ventilation, height, fire and structural safety.\n(f) Upto 1.0 percent of the total covered area of group housing project shall be allowable for convenient shopping such as grocery shop, vegetable shop, laundry and dry cleaning, medical store, confectionery, bakery, hair cutting saloon, stationery shop, milk booth excluding Club Building.\n(g) access to commercial building in group housing may be allowed from external road subject to the fulfilment of parking, setback and road width etc.\n(h) The Net Residential Density shall be permissible as per the provisions of the respective Master Plans, government notifications as amended from time to time whichever is applicable.\n[***]\nNotes. - (a) Rental housing/Hostel building shall be a detached building.\nNotes.\n(b) It shall provide kitchen with dining hall, common room for indoor games, first aid room, laundry, security guard room.\n(c) In Rental housing, upto 2% of the Floor Area Ratio. availed may be used for canteen, coffee shop, library, ATM, Grocery shop, Pharmacy, office, Mobile shop, Fruit/Vegetable shop, Barber shop or other similar activities for self use of the Users.\n(d) Basement shall be permissible as per sub-rule (6) of rule 31.\n(e) The provisions laid down in the rental housing policy shall be read with building bye laws concurrently.\n(B) Other general control for residential buildings. - (i) For calculation of infrastructure required for the project, the population of villa shall be counted @ 5 persons per villa and plotted development shall be counted @ 15 persons per plot, whereas in case of Independent floors having S+4 or G+3 it shall be @ 20 persons per plot and for group housing it shall be @ 5 persons per Dwelling Unit. where basement is used for habitable purpose then the density of five person per basement shall be added to the permissible density of the plot.\n(B) Other general control for residential buildings.\n(ii) Floating population shall be taken as minimum 100 person per acre for calculation of infrastructural/ services requirements only and shall not be counted towards the regular density of the project/ sector.\n(iii) The population density of Studio Apartments shall be counted as two persons per unit.\n(iv) The Population density of Rental housing shall be counted as one person per 12.5 sq.m of total covered area of the building or as per actual whichever is more.\n(v) The density for each category of flats in case of Group Housing/Apartment/ Studio Apartments shall be calculated separately. The promoter has to clearly indicate the area under each category of flats.\n(vi) The clubbing of two or more plots or plots earmarked for independent floors in row housing may be allowed. The promoter or owner has to get a revised Zoning Plan approved from the Competent Authority.\n(vii) In case of residential plot, it is mandatory to provide indigenous or fruit tree in the premises of plot as per criteria described in Part XI of these rules.\n(viii) In case of Low Density Country Homes Residential, Economical Weaker Section housing, Affordable housing, housing for all, Pardhan Mantri Awas Yojna (PMAY), Punjab Shehri Awas Yojana (PSAY) and any other policy relating to housing issued by State or Central Government, the physical and development norms as prescribed in the said policy as amended from time to time shall be applicable.\n(ix) Professional activity shall be allowed in residential plot and flats on any floor on the following condition:\nPart of the premises shall be permitted to be used upto a maximum of 25 % of FAR or 100 sq.m, whichever is less, for non-nuisance / non service / non-teaching/ non-commercial/ non trading activities for rendering consulting based on professional skills such as charted accountant, architect, planner, advocates, doctors (only consultancy) or other similar activities.\n20. (A) Commercial.\nTable 8:\n\t\t\t\tConvenient Shopping / Neighbourhood Shopping Plotted within\n\t\t\t\tapproved layout plan.\nTable 8:\n\t\t\t\tConvenient Shopping / Neighbourhood Shopping Plotted within\n\t\t\t\tapproved layout plan.\nS. No.\nS. No.\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nCategory\nCategory\nBooths\nBooths\nShops/ shop cum offices\nShops/ shop cum offices\nShops/ shop cum offices\nShops/ shop cum offices\nI.\nWidth of plot\nWidth of plot\nUpto 3m\nAbove 3m to 5m\nAbove 5m\nII.\nMinimum Approach Road\nMinimum Approach Road\n18m\n24m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n100% of plot area\nDepth of Plot\n% of plot area\nDepth of Plot\n% of plot area\nupto 12m\n100\nupto 12m\n100\nmore than 12m\n80\nmore than 12m\n75\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1\n1:2\n1:3\nV.\nNo. of Stories\nNo. of Stories\n1\n2\n4\nNote: Excluding mumty, parapet, lift room and\n\t\t\t\tarchitectural features\nVI.\nMinimum width of corridor/Canopy/Projection\n\t\t\t\tetc. for weather protection\nMinimum width of corridor/Canopy/Projection\n\t\t\t\tetc. for weather protection\n2.2m\n2.5m\n2.5m\nVII.\nParking\nParking\n2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\nNotes. - (a) The plotted Convenient Shopping / Neighbourhood Shopping development shall be permissible on 18m (60'-0\") wide road subject to the condition that the maximum area of the site shall not be more than 8000 sq.mt. The minimum approach road for area more than 8000 sq. mt. shall be 24m(80'-0\").\nNotes.\n(b) The F.A.R above 1:1.75 in case of commercial building, will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.\n(c) In case of commercial plot having openings on both front and rear, then the ground coverage to be permitted in such cases shall be upto 100% of the plot area carved out shops, shop-cum-shop/offices, shop-cum-flat etc. subject to the conditions that corridors of appropriate width, as specified in Table 8 above shall be provided in front of each opening. The basement shall be restricted under the building excluding the area under corridors. Floor Area Ratio, height, number of storeys, clear width of the corridor shall be governed by the width of the plot and stipulation made under these rules. However, the total coverage shall continue to be governed by the parking requirements mentioned as per Table 8 with adequate provision made both in front and rear of the site.\n[(d) Approach to upper floors in case of double storeyed shops, shop-cum- offices/ shops can also be permitted from the public corridor.]\n(e) Approach to basement floors shall be permitted only from within the booth/ shops/shop-cum-shop/offices.\n(f) Height of booths/ Shops/ shop cum offices shall be governed by control sheets/zoning plan.\n(g) In case of SCO, common staircase or common elevator is permissible maximum for two SCO subject to the condition that the minimum clear width of staircases shall be 1500 mm.\n(h) All Government commercial site planned for retail outlet shall be governed by approved layout plan/ zoning plan / standard architectural control sheets prepared by the development authorities concerned.\nTable 9: Commercials such as Shopping Mall /\n\t\t\t\tShopping Complex or a building primarily used for display and\n\t\t\t\tsale of merchandise or any similar purpose\nTable 9: Commercials such as Shopping Mall /\n\t\t\t\tShopping Complex or a building primarily used for display and\n\t\t\t\tsale of merchandise or any similar purpose\nS.No\nS.No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Approach Road\nMinimum Approach Road\n24m\nII.\nMinimum Frontage\nMinimum Frontage\n20m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n45% of Plot Area\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nMinimum approach road 24 m\n1:2.5\nMinimum approach road 30 m\n1:3.0\nMinimum approach road 45 m & above\nUnlimited*\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nsub-rule (1) of rule 26\nVII.\nParking\nParking\n2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\nNotes. - (a) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.\nNotes.\n(b) F.A.R above 1:1.75, will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.\nTable 10:\n\t\t\t\tMiniplex\nTable 10:\n\t\t\t\tMiniplex\nS.No\nS.No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Approach Road & Site Area\nMinimum Approach Road & Site Area\nplot size from 2000 sq.m and below 4000 sq.m\n18 m\nplot size 4000 and above sq.m\n24 m\nII.\nMinimum Frontage\nMinimum Frontage\n24 m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nMinimum approach road width 18 m\n1:2.0\nMinimum approach road width 30 m and above\n1:2.5\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nsub-rule (1) of rule 26\nVII.\nParking\nParking\n3.0 Equivalent Car Space per 100 square meters of the covered\n\t\t\t\tarea in respect of miniplex or cinema component and 2 Equivalent\n\t\t\t\tCar Space per 100 square meters of the balance covered area.\nNotes. - (a) F.A.R above 1:1.75, will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.\nNotes.\n(b) In case any provision is not specified /covered under these rules then the physical and development norms as specified in the miniplex policy or the Punjab Cinemas (Regulation) Act, 1952, as the case may be shall be applicable.\n(c) In case of Miniplex or Cinema the physical and development norms as specified in the miniplex policy or the Punjab Cinemas (Regulation) Act, 1952, as the case may be, shall be applicable, however, for the provision not specified /covered under above policies, these rules shall be applicable.\n(d) Commercial component such as retail, shopping restaurant, food courts etc. are permissible in miniplex.\nTable 11:\n\t\t\t\tMultiplex\nTable 11:\n\t\t\t\tMultiplex\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum plot size\nMinimum plot size\n4000 sq.m\nII.\nMinimum Approach Road\nMinimum Approach Road\n24 m\nIII.\nMinimum Frontage\nMinimum Frontage\n30 m\nIV.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nMinimum approach road 24 m\n1:2.0\nMinimum approach road 30 m\n1:2.5\nMinimum approach road 45 m and above\nUnlimited*\nVI.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nVII.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nsub-rule (1) of rule 26\nVIII.\nParking\nParking\n3.0 Equivalent Car Space per 100 square meters of the covered\n\t\t\t\tarea in respect of multiplex or cinema component plus 30 percent\n\t\t\t\tof the total covered area of that component i.e (multiplex or\n\t\t\t\tcinema component) and 2 Equivalent Car Space per 100 square\n\t\t\t\tmeters of the balance covered area.\nNotes. - (a) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.\nNotes.\n(b) The F.A.R above 1:1.75 , will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.\n(c) In case of Multiplex or Cinema the physical and development norms as specified in the multiplex policy or the Punjab Cinemas (Regulation) Act, 1952, as amended from time to time, shall be applicable, however, for any provision not specified /covered under above policies, these rules shall be applicable.\n(d) In case any provision is not specified /covered under these rules then the physical and development norms as specified in the multiplex policy or the\n(e) Commercial component such as retail, shopping restaurant, food courts etc. are permissible in multiplex.\nTable 12:\n\t\t\t\tHotel or Motel\nTable 12:\n\t\t\t\tHotel or Motel\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Approach Road\nMinimum Approach Road\nPlot size from 1000 sq.yd upto 2000 sq.yd\n12m\nPlot size above 2000 sq.yd upto 4000 sq.yd\n18m\nPlot size above 4000 sq.yd\n24m\nNote: In rural areas outside Master Plans, the Hotel activity\n\t\t\t\tupto one acre area shall be permissible on link roads having\n\t\t\t\tminimum width of 22'-0\" (4 karam). However, the developer\n\t\t\t\thas to widen the road to minimum 40 feet or as specified in the\n\t\t\t\tMaster Plan whichever is more, by leaving proportionate area from\n\t\t\t\this own land.\nII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nIII.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nFor plot size 1000 sq.yd upto 2000 sq.yd\n1:2.0\nFor plot size above 2000 sq.yd upto 4000 sq.yd\n1:2.5\nFor plot size above 4000 sq.yd\nUnlimited*\nIV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nV.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nsub-rule (1) of rule 26\nVI.\nParking\nParking\n2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nNotes. - (a) Commercial use within the Hotel Building envelope shall be permissible as per the policy of State Government, as amended from time to time.\nNotes.\n(b) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.\n(c) F.A.R above 1:3, will be chargeable on pro-rata basis. However for sites allotted or sold by the development authority, the charges shall be applicable as per the terms and conditions of the allotment letter.\nTable 13:\n\t\t\t\tClub\nTable 13:\n\t\t\t\tClub\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Approach Road\nMinimum Approach Road\nPlot size from 1000 sq.m upto 2000 sq.m\n18m (60'-0\")\nPlot size above 2000 sq.m\n24m (80'-0\")\nII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nIII.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1.0\nIV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport\n\t\t\t\t Authority and fulfilment of norms such as setbacks around\n\t\t\t\tbuilding, ground coverage, F.A.R., structural safety and fire\n\t\t\t\tsafety norms.\nV.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these\n\t\t\t\tbuilding rules.\nsub-rule (1) of rule 26\nVI.\nParking\nParking\n3 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nTable 14:\n\t\t\t\tGuest House/Lodging & Boarding/Service Apartments\nTable 14:\n\t\t\t\tGuest House/Lodging & Boarding/Service Apartments\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\n1000 sq.m\nII.\nMinimum Approach Road\nMinimum Approach Road\nPlot size from 1000 sq.m upto 2000 sq.m\n12m(40'-0\")\nPlot size above 2000 sq.m\n18m (60'-0\")\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nPlot size from 1000 sq.m upto 2000 sq.m\n1:1.0\nPlot size above 2000 sq.m\n1:2.0\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nVII.\nParking\nParking\n1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nTable 15:\n\t\t\t\tDhaba\nTable 15:\n\t\t\t\tDhaba\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nSite area\nSite area\nMinimum 1000 sq.m\nII.\nMinimum Approach Road\nMinimum Approach Road\nPlot size from 1000 sq.m upto 2000 sq.m\n18m (60'-0\")\nPlot size above 2000 sq.m\n24m (80'-0\")\nIII.\nMinimum Frontage\nMinimum Frontage\n20 m\nIV.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nV.\nFloor Area Ratio\nFloor Area Ratio\n1:0.5\nVI.\nHeight\nHeight\n6 m.\nVII.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nVIII.\nParking\nParking\n30% of plot area\nNotes. - (a) Maximum 50 sq.mt. area for Kiosks like STD, books, cassettes etc. can be permissible as ancillary uses within F.A.R\nNotes.\n(b) The access permission is required from competent authority if the site is located on scheduled road / State Highway/National Highway.\n(c) Approach from National Highways can be considered if the site fulfils minimum distance norm from intersection/access or abuts 7M wide service road or applicant submits prior permission of access from National Highway Authority of India (NHAI).\nTable 16:\n\t\t\t\tWholesale Trade/ Integrated Freight complex (Standalone)\nTable 16:\n\t\t\t\tWholesale Trade/ Integrated Freight complex (Standalone)\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\n1 Ha.\nII.\nMinimum Approach Road\nMinimum Approach Road\n24 m (80'-0\")\nIII.\nMinimum Frontage\nMinimum Frontage\n30 m\nIV.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1.0\nVI.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport\n\t\t\t\t Authority and fulfilment of norms such as setbacks around\n\t\t\t\tbuilding, ground coverage, F.A.R., structural safety and fire\n\t\t\t\tsafety norms.\nVII.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building\n\t\t\t\trules.\nVIII.\nParking\nParking\n2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nNote. - For Risk based approval of types of Warehouses / Integrated Freight complex (IFC) refer sub-rule (2) of rule 47.\nNote.\nTable 17: Warehouse / Godown (Standalone)\nTable 17: Warehouse / Godown (Standalone)\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\n2000 sq.m\nII.\nMinimum Approach Road\nMinimum Approach Road\n12 m (Minimum 22'-0\" widen to 40'-0\")\nIII.\nMinimum Frontage\nMinimum Frontage\n30 m\nIV.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of Plot Area\nV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1.0\nVI.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport Authority and\n\t\t\t\tfulfilment of norms such as setbacks around building, ground\n\t\t\t\tcoverage, F.A.R., structural safety and fire safety norms.\nVII.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these building rules.\nsub-rule (1) of rule 26\nVIII.\nParking\nParking\n2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] a.\nNote. - For Risk based approval of types of Warehouses / Integrated Freight complex (IFC) refer sub-rule (2) of rule 47.\nNote.\n(B) Petrol pumps / Filling -cum-service stations. - Petrol Pump/ filling-cum-service stations/ two-three wheelers petrol pump shall be governed as per instructions/ guidelines of Indian Roads Congress (IRC)/ Ministry of Road Transport and Highways (MORTH)/ Town and Country Planning Organisation (TCPO)/ Department of Housing and Urban Development, Government of Punjab.\n(B) Petrol pumps / Filling -cum-service stations.\n21. (A) Industry.\n[Table 18: Industry Plotted\n[Table 18: Industry Plotted\nSerial No.\nSerial No.\nParameter\nParameter\nPermissible Limits\nPermissible Limits\n1.\nMinimum Approach Road\nMinimum Approach Road\n15m (Min. 16'-6\" widen to 50'-0\") or\n\t\t\t\t\tas per master plan whichever is more\n2.\nMaximum Ground Coverage\nMaximum Ground Coverage\n65 % of the plot area**\n3.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nUnlimited*\n4.\nMaximum Height of Building\nMaximum Height of Building\nBelow 15m\nNote: Excluding equipment, machinery such as\n\t\t\t\t\tchimney, boiler, plant, hammer, silos etc. irrespective of its\n\t\t\t\t\theight.\n5.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these rules.\n6.\nParking\nParking\nGeneral Industry\n1 Equivalent Car Space per 100 sq.m. of the\n\t\t\t\t\ttotal floor area ratio.\nInformational Technology\nFor Site Area upto 2 Acres : 1.0 Equivalent Car\n\t\t\t\t\tSpace per 100 sq.m. of the total floor area ratio.\nFor Site Area above 2 Acres: 2 Equivalent Car\n\t\t\t\t\tSpace per 100 sq.m. of the total floor area ratio.\nNote. - (a) **5% additional ground coverage shall be permitted in case of retail service industry.\nNote.\n(b) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.\n(c) In case of Industrial Estate/ Private Industrial Areas or Conglomeration of Industries opt for central parking then:\n(i) Minimum 20% parking shall be within the premises of the industry.\n(ii) The parking requirement if provided in mechanical/ common pool area shall be duly certified by the concerned association by whom it is being maintained.\n(iii) The share of common parking shall be calculated as per the total area of the industrial plot duly certified by the concerned agency maintaining that parking.\n(iv) In case any false claim regarding common parking is observed then the industrial plot holder has to provide parking in his own premises.] .\nTable 19: General industry flatted\nTable 19: General industry flatted\nS.No\nS.No\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\n2000 sq.mt.\nII.\nMinimum Approach Road\nMinimum Approach Road\n18m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40 %\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nUnlimited*\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport\n\t\t\t\t Authority and fulfilment of norms such as setbacks around\n\t\t\t\tbuilding, ground coverage, F.A.R., structural safety and fire\n\t\t\t\tsafety norms.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these\n\t\t\t\tbuilding rules.\nsub-rule (1) of rule 26\nVII.\nParking\nParking\n2 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nTable 20: Information Technology flatted\nTable 20: Information Technology flatted\nS. No\nS. No\nParameter\nParameter\nPermissible Limits\nI.\nI.\nMinimum Site area\nMinimum Site area\nAs per I.T. policy\nII.\nII.\nMinimum Approach Road\nMinimum Approach Road\n18m\nIII.\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40%\nIV.\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\nUnlimited*\nV.\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from \n\t\t\t\tAirport Authority and fulfilment of norms such as setbacks around\n\t\t\t\tbuilding, ground coverage, F.A.R., structural safety and fire\n\t\t\t\tsafety norms.\nVI.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these\n\t\t\t\tbuilding rules.\nsub-rule (1) of rule 26\nVII.\nVII.\nParking\nParking\nSite Area upto 2 Acres\n1.0 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\nSite Area above 2 Acres\n2.0 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\n(B) Other controls for Industrial Buildings. - (i) For industrial plots more than 1000 sq.m, 10% of the total plot area shall be reserved as amenity open space. When such amenity open space exceeds 1500 sq.m, the excess area could be utilized for construction of buildings for banks, canteen, welfare centre and such other common purposes.\n(B) Other controls for Industrial Buildings.\n(ii) Upto 15 percent of the total covered area in industrial buildings shall be permissible for the housing of staff or workers.\n(iii) *Unlimited F.A.R shall be subject to fulfilment of building controls such as ground coverage, setback around building, parking norms, light and ventilation, height, fire and structural safety.\n22. (A) Educational.\nTable 21: Pre Nursery / Nursery School /\n\t\t\t\tcrèche\nTable 21: Pre Nursery / Nursery School /\n\t\t\t\tcrèche\nS. No.\nS.\nNo.\nParameter\nParameter\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\n1000 sq.m\nII.\nMinimum Approach Road\nMinimum Approach Road\n12 m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of site area\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1.0\nV.\nSetbacks around buildings\nSetbacks around buildings\nFront\n6m or 1/3 of the height of the building,\n\t\t\t\twhichever is more\nOther side\n4.5m or 1/3 of the height of the building,\n\t\t\t\twhichever is more\nVI.\nParking\nParking\n1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\nVII.\nMaximum number of Floors\nMaximum number of Floors\nG+1\nNote. - only ground floor shall be used for academics however first floor may be used for residential, office, storage etc.\nNote.\nTable 22: Primary school (class 1 to 5)\nTable 22: Primary school (class 1 to 5)\nS. No.\nS. No.\nParameter\nParameter\nPermissible Limits\nPermissible Limits\nI.\nMinimum Site area\nMinimum Site area\nAs per the norms of the affiliation authority\n\t\t\t\tor 5000 sq mts whichever is more\nII.\nMinimum Approach Road\nMinimum Approach Road\n12m\nIII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of site area\nIV.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1.2\nV.\nParking\nParking\n1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio]\nVI.\nMaximum Height of Building\nMaximum Height of Building\nbelow 15m\nVII.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these\n\t\t\t\tbuilding rules.\nsub-rule (1) of rule 26\nTable 23: High/ Senior secondary school/\n\t\t\t\tCollege or Educational Institute/Universities.\nTable 23: High/ Senior secondary school/\n\t\t\t\tCollege or Educational Institute/Universities.\nS. No.\nS. No.\nParameter\nParameter\nPermissible Limits\nI.\nI.\nMinimum Approach Road\nMinimum Approach Road\nfor School\nWithin Master Plan\n\t\t\t\t-18m (60'-0\")\nOutside Master Plan-12m (40'-0\")\nfor College/university\nWithin Master Plan\n\t\t\t\t-24m (80'-0\")\nOutside Master Plan-18m (60'-0\")\nII.\nII.\nMaximum Ground Coverage\nMaximum Ground Coverage\n40% of plot area\nIII.\nIII.\nMaximum Floor Area Ratio\nMaximum Floor Area Ratio\n1:1.5\nIV.\nIV.\nParking\nParking\nSchool, College\n1.5 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nUniversity Campus\n1.0 [Equivalent Car Space per 100 square meters of the total Floor Area Ratio] .\nV.\nV.\nMaximum Height of Building\nMaximum Height of Building\nNo Restriction subject to clearance from Airport\n\t\t\t\t Authority and fulfilment of norms such as setbacks around\n\t\t\t\tbuilding, ground coverage, F.A.R., structural safety and fire\n\t\t\t\tsafety norms.\nVI.\nVI.\nSetbacks around buildings\nSetbacks around buildings\nRefer sub-rule (1) of rule 26 of these\n\t\t\t\tbuilding rules.\nsub-rule (1) of rule 26\n(B) Other controls for Educational Building(s). - (i) In case of new school area of 1 acre or above, the front boundary wall shall be recessed by 6m to accommodate visitors parking within setback area.\n(B) Other controls for Educational Building(s).\n(ii) Minimum 15% of site area shall be kept/developed as playground with minimum width of 15 m.\n(iii) Upto 15 percent of the total covered area in educational buildings shall be permissible for the housing of staff or workers.\n(iv) In case of large Campus/ Universities / Indian Institute of Technology (IIT) / Indian Institute of Management (IIM), upto 30% of the total covered area (F.A.R) can be utilized for residential use for essential staff and fellow accommodations by providing housing for staff, dormitories, guest houses or creche.\n(v) Student Hostel shall not be count in residential component.",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
"prev_section": "17",