[(2) Notice of building:
[(3) Building by laws:
(a) prescribe the manner in which notice of the intention to erect or re-erect a building shall be given to the committee;
(b) require that with every such notice shall be furnished a site plan of the land on which it is intended to erect or re-erect such building and a plan and specification of the building of such character and with such details as the bye-laws may require;
(c) where the building appears likely to be be used as a factory, require the provisions of adequate housing accommodation in connection therewith.]
[190. Power of committee to make bye-laws as to erection or re-erection of buildings.
(a) the materials and method of construction to be used for external and party walls, roofs, floors, stair-cases, lifts, fire places and chimneys;
(b) the materials and method of construction and position of fire- places, chimneys, drains latrines, privies, urinals, and cess-pools;
(c) the heights and slope of the roof above the uppermost floor upon which human beings are to live or cooking operations are to be carried on;
(d) the ventilation and the space to be left about the buildings to secure the free circulation of air and for the prevention of fire;
(e) the line of frontage where the building abuts on a street;
(f) the number and height of the storeys of which the building may consist;
(g) the means to be provided for egress from the building in case of fire;
(h) the materials and method of construction to be used for godowns intended for the storage of foodgrains in excess of fifty maunds in order to render them rat-proof:
(i) the minimum dimensions of rooms intended for use as living rooms or sleeping rooms:
(j) the ventilation of rooms and the minimum dimensions of doors [and windows [***] ] .
(k) the position and dimensions of projections beyond the outer face of any external wall of a building; and
(l) the height of factory chimneys and the provision to be made for consumption of smoke arising from the combustible used in any fire place or furnace in factory.
Section 189 • Punjab Municipal Act, 1911
189. Prohibition of building without sanction.
punjab-municipal-act-1911-sec-189.json
•
Section 189
{
"act_title": "Punjab Municipal Act, 1911",
"act_slug": "punjab-municipal-act-1911",
"section_label": "Section",
"section": {
"number": "189",
"title": "189. Prohibition of building without sanction.",
"chapter": null,
"content": "[(2) Notice of building:\n[(3) Building by laws:\n(a) prescribe the manner in which notice of the intention to erect or re-erect a building shall be given to the committee;\n(b) require that with every such notice shall be furnished a site plan of the land on which it is intended to erect or re-erect such building and a plan and specification of the building of such character and with such details as the bye-laws may require;\n(c) where the building appears likely to be be used as a factory, require the provisions of adequate housing accommodation in connection therewith.]\n[190. Power of committee to make bye-laws as to erection or re-erection of buildings.\n(a) the materials and method of construction to be used for external and party walls, roofs, floors, stair-cases, lifts, fire places and chimneys;\n(b) the materials and method of construction and position of fire- places, chimneys, drains latrines, privies, urinals, and cess-pools;\n(c) the heights and slope of the roof above the uppermost floor upon which human beings are to live or cooking operations are to be carried on;\n(d) the ventilation and the space to be left about the buildings to secure the free circulation of air and for the prevention of fire;\n(e) the line of frontage where the building abuts on a street;\n(f) the number and height of the storeys of which the building may consist;\n(g) the means to be provided for egress from the building in case of fire;\n(h) the materials and method of construction to be used for godowns intended for the storage of foodgrains in excess of fifty maunds in order to render them rat-proof:\n(i) the minimum dimensions of rooms intended for use as living rooms or sleeping rooms:\n(j) the ventilation of rooms and the minimum dimensions of doors [and windows [***] ] .\n(k) the position and dimensions of projections beyond the outer face of any external wall of a building; and\n(l) the height of factory chimneys and the provision to be made for consumption of smoke arising from the combustible used in any fire place or furnace in factory.",
"footnote": "",
"is_definition": false,
"sort_order": 165
},
"prev_section": "188",
"next_section": "189"
}