18. Fire detecting and extinguishing systems.

Appendix E
Appendix E
Table 2
Table 2
Factories
Factories
SI. No.
SI. No.
Land and buildings use
Land and buildings use
Area of parking spaces unit in sq. metres
Area of parking spaces unit in sq. metres
Number of units of spaces to be provided
Number of units of spaces to be provided
(1)
(2)
(3)
(4)
1.
Residential:
(a) Single Family House.
17.5
One for every site with an area of 350 square
metres and over.
(b) Apartment Flats
17.5
One for every two families.
2.
Commercial:
One for the first 200 square metres of floor
area and one additional unit for every 100 square metres or part
thereof of every 200 square metres,
(a) Shops.
17.5
(b) Shopping Centres.
20
One for every 250 square metres of site area or
part thereof.
(c) Office and Firms.
20
(i) For building with
floor area less than 100 square metres Nil.
(ii) For building with floor area over 200
square metres, one for every 200 square metres or part thereof up
to 1,000 square metres and one additional unit for every 100
square metres of floor area over 1,000 square metres.
(d) Restaurants.
17.5
(i)Restaurants with
less than 50 seats – Nil.
(ii) With 50 seats and over one unit for every
20 seats or parts of 20 seats.
(e) Hotels and Lodges.
17.5
One for every 6 beds.
(f) Cinemas and Public Halls including Community
Hall.
(g) Kalyanamandapam, etc.
17.5
One for every 20 square metres of site area.
3.
Warehousing and Wholesale stores.
One for every 500 square metres of floor area or
part thereof.
4.
Public and Semi-public Offices.
20
(i)For building with
floor area less than 100 square metres – Nil.
(ii) Floor area of 100 square metres and
above-one for every 200 square metres or part thereof.
5.
Hospitals and Nursing Homes.
17.5
One for every 15 beds,
6.
Industries.
30
(i) Up to 100 square metres of floor area -Nil.
(ii) With floor area over 100 square metres-one for every 200
square metres.
7.
For other uses, Institutions and Transport and Communication
Centres.
Requirements to be assessed by Commissioner in
consultation with Commissioner of Police and [Director of Town
Planning.]
Appendix-L (See Special Rule 10(2) (d) of Multi-storeyed Buildings) Design Loads and other Forces For Design of Masonry Structures 1. Deadloads. - The deadload in a building shall comprise the weight of all walls, partitions, floors and roofs and shall include the weights of all other permanent constructions in the building. The dead load is determined adopting the dead weight of the construction material and as given in the following Table: -
Appendix-L
(See Special Rule 10(2) (d) of Multi-storeyed Buildings)
Design Loads and other Forces For Design of Masonry Structures
Design Loads and other Forces For Design of Masonry Structures