Multi-Storeyed and Public Buildings Rules, 1973
Multi-Storeyed and Public Buildings Rules, 1973
Sections
1. Short title.
Section 12. Definition.
Section 23. Application of rules.
Section 34. Area for the construction.
Section 45. Engineer's approval.
Section 56. Site plan, streets and spaces.
Section 67. Building plans.
Section 78. Specifications.
Section 89. Floor area ratio and maximum plot coverage.
Section 910. Structural sufficiency. - (1) Foundations.
Section 1011. Open Spaces.
Section 1112. Means of access and circulation.
Section 1213. Parking and parking facilities.
Section 1314. Fire safety.
Section 1415. Architectural Control.
Section 1516. Sufficient exits.
Section 1617. Aisles and spacing rows of seats.
Section 1718. Fire detecting and extinguishing systems.
Section 181. Deadloads.
Section 12. Live loads.
Section 23. Wind load.
Section 34. Seismic loads.
Section 4
multi-storeyed-and-public-buildings-rules-1973.json
•
22 Sections
•
Tamil Nadu
{
"id": 23862,
"slug": "multi-storeyed-and-public-buildings-rules-1973",
"title": "Multi-Storeyed and Public Buildings Rules, 1973",
"short_title": "Multi-Storeyed and Public Buildings Rules, 1973",
"act_number": "Published vide Notification No. G.O. MS. No. 1769,",
"act_year": 1973,
"act_type": "STATE",
"location": "Tamil Nadu",
"law_status": "unknown",
"enactment_date": null,
"description": "Multi-Storeyed and Public Buildings Rules, 1973",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "1. Short title.",
"chapter": null,
"content": "A. Multi-Storeyed Building\nA. Multi-Storeyed Building",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "2",
"title": "2. Definition.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": true,
"sort_order": 1
},
{
"number": "3",
"title": "3. Application of rules.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "4",
"title": "4. Area for the construction.",
"chapter": null,
"content": "(b) The minimum extent of site for construction of a multi-storeyed building shall be not less than 4 grounds in extent and should have the shortest side not less than 24-50 metres (80 feet) and shall abut on a street not less than 12-25 metres (40 feet) in width.\n(c) In so far as the determination of sufficiency of all aspects of structural design, building, services, plumbing, fire protection, construction practices and safety, the specifications, standards and codes of practice recommended in the National Building Code of India, 1970 shall be fully conformed to, besides those prescribed in these rules and any breach thereof shall be deemed to be a breach of the requirements under these rules.",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "5",
"title": "5. Engineer's approval.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "6",
"title": "6. Site plan, streets and spaces.",
"chapter": null,
"content": "(a) The existing and proposed building in relation to the boundaries of the site and in relation also to/all adjacent streets, buildings (with number of storeys and height) and premises within a distance of 15 metres (50 feet) of the site;\n(b) The means of access from the street or streets to all buildings existing and proposed in the site, to the parking spaces and facilities provided in the site within or outside the buildings and for scavenging and fire protection;\n(c) The spaces to be left about the building for circulation, air, light access, parking and amenity; and\n(d) The general layout of the columns and load-bearing walls showing the estimated loads including moments and torques coming on the foundation units.",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "7",
"title": "7. Building plans.",
"chapter": null,
"content": "(a) Floor plans of all floors and covered area, indicating clearly the size and spacing of all framing members and size and arrangements of rooms and the position of staircases, ramps and lift walls;\n(b) Longitudinal and cross-sections of the buildings to show size of footings, basement and superstructure, framing members and details of building and room heights and of staircases, etc.;\n(c) In the case of constructions using steel structures, complete1 design drawings, showing sizes, sections and relative location of the various steel members, floor levels, column centres and offsets;\n(d) In the case of pre-fabricated building drawings, describing the elements of the structure or assembly including all required data or physical properties of component materials with details of joints to an enlarged scale, site or shop location of services such as installation of piping, wiring or other accessories and location of handling arrangements for lifting and handling the pre-fabricated elements; and\n(e) Plans and sectional details of water-supply and sewerage system for the building.\n[7A. Water Conservation.\n(A)Tiled and sloped terrace building. - (1) In the tiled or sloped building, semicircular gutters of width 15 to 25 centimetres of plastic or any other material shall be provided on the down side roof slopes of the building for harvesting rain-water. The gutter shall be connected at the downstream end with a down-pipe of 75 to 100 millimetres diameter, depending upon roof area and size of tank to convey the harvested rain-water from gutters to a plastic or any other material storage tank or sump (through a filter unit). An inlet screen (wire mesh) to prevent entry of dry leaves and other debris into the downpipe shall be fitted. The collected rain-water from the roof shall be allowed to pass through a filter unit. The filter unit is to be filled with suitable filter material such as well-burnt broken bricks (or pebbles) up to 15 centimetres from top. The top 15 centimetres shall be filled up with coarse sand. The filter unit shall be placed either over a storage tank or at bottom of the down-pipe.\n(A)Tiled and sloped terrace building.\n(2) The filtered rain-water shall be collected in a collection tank or storage tank placed over the ground or underground. The shape of the tank shall be cylindrical, rectangular or square of suitable size with a capacity ranging from 1,000 to 10,000 litres or even higher depending on the roof area. The materials of construction shall be brick work, stone work, cement bricks, ferro-cement, High Density Polyethylene (HDPE), plain cement concrete or reinforced cement concrete. The storage tanks or collection tanks shall be provided with pipe fixtures at appropriate places to draw the water, to clean the tank and to dispose of the excess water depending upon use or reuse either to open well or bore well to a percolation pit.\n(B) Ordinary building (Ground + First Floor). - (1) Percolation pits of 30 to 45 centimetres diameter and of depth adequate, not less than one metre, to recharge the ground, shall be made. This pit shall be filled with suitable filter material such as well-burnt broken bricks (or pebbles) up to 15 centimetres from top. The top 15 centimetres shall be filled up with coarse sand. The top of this pit shall be covered with perforated reinforced concrete cement (RCC) slab or of any other material, wherever considered necessary. The number of such percolation pits shall be provided on the basis of one pit per 30 square metres of available open terrace area or plinth area. The cross distance between the pits shall be minimum 3 metres.\n(B) Ordinary building (Ground + First Floor).\n(2) Wherever an open well or bore well is available within the building premises the rain-water collected from the open terrace shall be collected through pipes of 150 millimetres diameter or other suitable sizes and led to filter pit of size 60 centimetres x 60 centimetres x 60 centimetres x 60 centimetre (with appropriate filter material) and then led into the open well or bore well through 150 millimetres diameter or other suitable pipes, after filling up a storage tank or sump.\n(3) Wherever existing water storage sumps are available, the rain-water so collected, after it passes through the filter, shall be allowed to flow to the sump through closed pipes. An overflow pipe shall be provided to the storage sump so that the surplus water is led into the nearby open well or bore well or percolation pit.\n(4) In addition to the percolation pits of 30 centimetres diameter to be provided at 3 metre intervals, a pit of 1 to 1.5 metres width and appropriate depth, so as to recharge the ground, shall be provided all along the plinth boundary depending upon the soil classification below ground. This pit shall be filled with appropriate filter material namely, broken bricks, pebbles, broken stones, etc., at the bottom and the top 15 to 25 centimetres shall be filled with coarse sand. The ground or pavement surface around the building shall be sloped towards the percolation pit so that the surplus rain-water from terrace and sides, open spaces, etc., flow over this sloped surfaces and spread into the filter bed all around. Masonry dwarf walls 5 to 7.5 centimetres or of suitable height depending upon the site conditions shall be constructed, if necessary, at the entrance and exit gates to allow the surplus rain-water collected within the compound to recharge the ground within the premises itself, and from draining out to the road.\n(5) If the sub-soil is not a permeable one (namely, clay or black cotton) appropriate recharge structures, namely, recharge shaft or bore pit shall be provided below the filtration pits so as to recharge the ground.\n(C) Group development, industries and institutional building: - (1) For buildings for Ground + One Floor or Ground + 2 floors and above located within group development, industrial or institutional premises, the specification detailed in items A, B and C above shall apply.\n(C) Group development, industries and institutional building:\n(2) The surplus surface run-off rain-water, in the open spaces within the Group development or industrial or institutional premises shall be allowed to run towards collection drains of suitable size and these drains shall be construed as rain-water friendly storm-water drains. All the approach and access roads to the buildings within the group development or industrial or institutional premises shall also be provided within the rain-water-friendly storm-water drains. These rain-water-friendly storm-water drains shall not have pave bottom. If adequate spaces, are available in low lying areas, percolation ponds of suitable size shall be formed and these rain-water-friendly storm-water drains shall be led into the percolation ponds for recharging the ground.\n(3) For other localised areas, recharge pits of .size of minimum 1 metre x 1 metre x 1 metre or 1 metre diameter shall be provided wherever needed, so as to prevent rain-water stagnation around the building. For other places catch water pit structures of size 30 centimetres diameter and 30 centimetres depth or higher depth as necessary shall be provided wherever necessary. For existing paved storm-water drains, catch water pits of 30 centimetres diameter and 30 centimetres depth or higher depth, as necessary, shall be provided at the bottom of these drains at 10 to 15 metre intervals. These catch water pits shall be filled with appropriate filter material as described in item 'B' above for ordinary building (Ground + First floor).",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "8",
"title": "8. Specifications.",
"chapter": null,
"content": "(a) General and detailed specifications, giving the type and grade of materials to be used;\n(b) Detailed computations, stress diagrams to show the sufficiency and correctness of the design; and\n(c) Type and condition of soil or rock to which the foundation transfers the loads.",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "9",
"title": "9. Floor area ratio and maximum plot coverage.",
"chapter": null,
"content": "Floor Area Ratios, and Maximum Plot Coverage For Different Building Types.\nFloor Area Ratios, and Maximum Plot Coverage For Different Building Types.\nSI. No.\nSI. No.\nBuilding type\nBuilding type\nFloor area ratio\nFloor area ratio\nPlot coverage\nPlot coverage\n(1)\n(2)\n(3)\n1.\nResidential\n150\n35\n2.\nCommercial -\n(a) George Town and other special areas declared\n\t\t\t\tby council with the approval of Director of Town Planning\n250\n50\n(b) Other areas of the city\n160\n40\n3.\nPublic and Industrial -\n(a) George Town and other special areas declared\n\t\t\t\tby council\n150\n50\n(b) Other areas of the city\n100\n50\n(a) A basement or cellar and space under a building constructed on stilts and used as parking space, store-room and air-conditioning plant room used as necessary to the principal one;\n(b) Electric cabin or sub-station, watchman's booth, pump house and garage stilts; and\n(c) Staircase room and lift rooms above the common storey, architectural features, chimneys.",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "10",
"title": "10. Structural sufficiency. - (1) Foundations.",
"chapter": null,
"content": "(a) Every wall, column post and beam of building shall be supported adequately by foundations of concrete or reinforced concrete, piles, piers, caisson or other foundations of such thickness and projection as will be necessary to safely sustain and consult all the dead and superimposed load without exceeding the limitations of permissible stresses provided in these rules.\n(b) All foundations, apart from those resting on bedrock, shall be carried down below the level of possible damage by frost or seasonal changes on soils possessing shrinking and swelling, characteristics, such as clayey soils.\n(c) The structural design of the foundations shall be determined as per the recommendations in the National Building Code of India, 1970 to ensure sufficiency and safety of the structures and to keep the stresses of the foundation materials and supporting soils within permissible limits prescribed in these rules.\n(d) Piles, either friction piles or end bearing piles, may be used for the foundations of a building when soil condition are suitable and their design, use and spacing shall conform to the recommendations in Part VI - section 2 of the National Building Code.\n(e) All piles used to support any structure or part thereof shall be driven, jetted or otherwise embedded to such depth as is necessary to secure adequate soil or rock bearing capacity and in such a manner as not to impair their strength and shall be of sufficient strength to Withstand also all stresses resulting from the handling and driving.\n(2) Walls and Columns.\n(b) Maximum slenderness ratio:\nWalls.\nColumn.\n(i) In the case of load-bearing walls set in cement mortar (1: 6) or cement lime mortar (1:2:9), the slenderness ratio shall not exceed 18 and for those set in lime mortar it shall not exceed 12.\n(ii) In the case of non-load-bearing walls, the slenderness ratio shall not exceed 30 for panel walls and curtain walls and shall not exceed 24 for force standing walls and parapet walls.\n(iii) The slenderness ratio for load-bearing column shall not exceed 12.\n(c) Where a solid wall or masonry is load-bearing, its thickness shall not be less than that determined by the calculated masonry method through the monograms of the National Building Code of India, 1970 unless otherwise determined through the structural analysis of the building on accepted principles of mechanics to sustain the most adverse combination of loads to which the building shall be subject to during or after erection.\n(d) The design loads and other forces to be taken for the design of masonry structures shall conform to those laid down in Part VI -Section I of the National Building Code of India, 1970 briefly extracted in Appendix-L to these rules.\n(e) Where a wall is sub-divided into panels by adequate horizontal or vertical supports or both, the individual panels shall be designed for structural sufficiency.\n(f) Where reinforced concrete walls are intended to carry vertical loads, they should be designed generally in accordance with the design criteria for columns. The cross-sectional area of vertical reinforcement and the lateral reinforcement parallel to the wall face may be reduced to not less than 0.2 per cent.\n(g) The thickness of a reinforced concrete wall should not be less than 10 cm.\n(3) Concrete and steel structures.\n(4) Pre-fabricated building.\n(5) Excavations.\n(b) No excavation for any purpose shall extend within 30 cm. of the angle of repose or natural slope of the soil under any footing or foundation unless such footing or foundation is properly under-pinned or protected against settlement.\n(c) Where an excavation is back filled, measures shall be taken to place the back fills as to -\n(i) maintain the lateral support of the soil exposed by the excavation;\n(ii) have a bearing capacity adequate to support the anticipated surcharge; and\n(iii) prevent detrimental settlement.",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "11",
"title": "11. Open Spaces.",
"chapter": null,
"content": "(a) There shall be a permanent open air space, forming an integral part of the site and of a minimum extent specified in this rule, between each of the boundaries of the site and every building proposed within the site.\n(b) The extent of the open spaces (specified in the above sub-rule) which shall be co-extensive with the site boundaries shall be as follows: -\nBuilding Type\nBuilding Type\nMinimum open yard from the site boundaries\nMinimum open yard from the site boundaries\n(1)\n(2)\n(i) Building up to a height of 10 metres.\nThree metres.\n(ii) Building of height above 10 metres up to 30\n\t\t\t\tmetres\nThree metres plus 1 metre for every additional 3\n\t\t\t\tmetres/or fraction thereof over 10 metres.\n(iii) Building of height over 30 metres.\nTen metres plus 1 metre for every additional 5\n\t\t\t\tmetres or fraction thereof, subject to a maximum of 16 metres.\n(c) The space specified above shall be kept open to the sky and free from any erection of any building other than a fence or compound wall, provided, however, that parking garages not exceeding 3 metres in height and subject to compliance with the stipulations of F.A.R. and access ways may in the case of sites abutting more than one screen on the wider of the streets and provided also that open yards may be used for the provision of open access ways to the building and parking facilities.",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "12",
"title": "12. Means of access and circulation.",
"chapter": null,
"content": "(b) The space so set apart as means of access shall be separately distinguished from any house, gully or open space for amenity requirement prescribed under the rules.\n(c) Every such means of access shall be made drained and lighted to the satisfaction of the Engineer and manhole covers or other drainage, water or any other fittings laid in such means of access shall be flush with the finished surface level so as not to obstruct safe travel over the same.\n(d) Any person who undertakes construction work on building shall not reduce the access to any building previously existing below the minimum width prescribed under these rules.\n(b) An exit may be a doorway, corridor, passageway to an internal staircase or external staircase or to a verandah or roofs or terrace having access to the street.\n(c) Exits shall be so arranged as to provide continuous means to egress to the exterior of a building or an exterior open space leading to a street, without passing through any occupied unit.\n(d) Exits shall be so located that the travel distance on the floor shall not exceed 22.5 metres in the case of residential and public buildings and 30 metres in the case of commercial, industrial and other buildings. There shall be at least two exits serving every floor and at least one of them shall be stairway.\nNotes. - Travel distance means the distance from any point in the floor area to any exit measured along the path of egress travel except that when floor areas are sub-divided into rooms used singly or suites or room and served by corridors or passages, the travel distance may be measured from the corridor entrance of such rooms or suites to the nearest exit.\nNotes.\n(e) Width of any exit shall not be less than 100 cm. and shall be determined for the total number of occupants as specified in the following Table. The unit of exit width for measuring the capacity of exits shall be 50 cm. A clear width of 25 cm. shall be at an additional half unit and clear width less than 25 cm. shall not be covered for exit width.\nSI. No.\nSI. No.\nOccupancy\nOccupancy\nNumber of occupants\nNumber of occupants\nStairways\nDoor\n(1)\n(2)\n(3)\n(4)\n1.\nResident\n25\n75\n2.\nBusiness\n50\n75\n3.\nEducational\n25\n75\n4.\nOther public buildings\n60\n90\n5.\nIndustrial\n50\n75",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "13",
"title": "13. Parking and parking facilities.",
"chapter": null,
"content": "(b) Necessary provision shall be also made for the circulation of vehicles gaining access to and from (i) the parking spaces and facilities and (ii) the premises into the street.",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "14",
"title": "14. Fire safety.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "15",
"title": "15. Architectural Control.",
"chapter": null,
"content": "(i) Engineer;\n(ii) a Town Planner of Government; and\n(iii) a prominent private Architect, provided that the Architect member of the panel shall not have made the plans and designs for the buildings under consideration.\nB. Public Buildings.\nB. Public Buildings.",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "16",
"title": "16. Sufficient exits.",
"chapter": null,
"content": "(b) There shall be at least two separate exits as remote from each other as practicable for each room, hall or place of assembly, with a capacity of 600 persons, at least three separate exits when the capacity is between 601 to 1,000, at least four separate exits when the capacity is over 1000:\n[16A. Water Conservation.\n[16B. Provision of Rain-Water Harvesting Structure.\n(1) in every building owned or occupied by the Government or a statutory body or a company or an institution owned or controlled by the Government-rain-water harvesting structure shall be provided in the manner specified in rule 7-A on or before the 10th October 2003.\n(2) (a) subject to sub-rule (1) every owner or occupier of a building shall provide rain-water harvesting structure in such building in the manner specified in rule 7-A on or before the 31st August 2003. If the owner or occupier of the building fails to provide the said rain-water harvesting structure by the said date, the executive authority or any person authorised by him in this behalf may after giving notice to the owner or occupier of the building, cause rain-water harvesting structure to be provided in such building and recover the cost of such provision along with the incidental expense thereof in the same manner as property tax. This however, does not absolve the liability of the owner or occupier of the building from providing the rain-water harvesting structure before the 10th October 2003.\n(b) if the owner or occupier of the building fails to provide rain-water harvesting structure on or before the 10th October 2003, the water supply connection provided to such building shall be disconnected till rain-water harvesting structure is provided.]\n[16C. Separation of bath and wash-basin water and reuses.",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "17",
"title": "17. Aisles and spacing rows of seats.",
"chapter": null,
"content": "(b) Where all the aisles do not directly meet the exit doors, cross aisles of minimum 1 metre width and at the rate of one cross aisle for every 19 rows of seats shall be provided parallel to the line of seating so as to provide direct access to the exit.\n(c) Rows of seats between aisles shall not have more than 14 seats and in the case of such rows opening to an aisle at one end, shall not have more than 7 seats.\n(d) There shall be a minimum space of 85 cm. between the backs of any two rows of seats and a minimum of 35 cm. between the back of any seat and the front of the seat immediately behind as measured between plumb lines.\n[17-A. Separation of bath and wash-basin water and reuse.\n(i) Ordinary buildings (Ground + I Floor, residential buildings, not exceeding four dwelling units or Commercial/Industrial/Institutional building not exceeding 300 square metres). - The waste water from the bath and wash-basin shall be used for ground-water recharge by organic filtration (by providing suitable filter media) depending upon the soil suitability or for recycling for toilet flushing as indicated for other buildings specified in item (ii) below, -\n(i) Ordinary buildings (Ground + I Floor, residential buildings, not exceeding four dwelling units or Commercial/Industrial/Institutional building not exceeding 300 square metres).\n(ii) Building other than buildings specified in time (1) above. - Each building shall have a separate downward pipeline to collect waste water from bath and wash basins and the collected waste water shall be treated adequately by organic or mechanical recycling and taken to a sump for onward pumping to the exclusive overhead tank or to a separate compartment of overhead tank, for exclusive use of toilet flushing cisterns. The excess waste water not reused for toilet flushing, shall be suitably connected to the rain-water recharge structures for ground-water recharge.\n(ii) Building other than buildings specified in time (1) above.",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "18",
"title": "18. Fire detecting and extinguishing systems.",
"chapter": null,
"content": "Appendix E\nAppendix E\nTable 2\nTable 2\nFactories\nFactories\nSI. No.\nSI. No.\nLand and buildings use\nLand and buildings use\nArea of parking spaces unit in sq. metres\nArea of parking spaces unit in sq. metres\nNumber of units of spaces to be provided\nNumber of units of spaces to be provided\n(1)\n(2)\n(3)\n(4)\n1.\nResidential:\n(a) Single Family House.\n17.5\nOne for every site with an area of 350 square\n\t\t\t\tmetres and over.\n(b) Apartment Flats\n17.5\nOne for every two families.\n2.\nCommercial:\nOne for the first 200 square metres of floor\n\t\t\t\tarea and one additional unit for every 100 square metres or part\n\t\t\t\tthereof of every 200 square metres,\n(a) Shops.\n17.5\n(b) Shopping Centres.\n20\nOne for every 250 square metres of site area or\n\t\t\t\tpart thereof.\n(c) Office and Firms.\n20\n(i) For building with\n\t\t\t\tfloor area less than 100 square metres Nil.\n(ii) For building with floor area over 200\n\t\t\t\tsquare metres, one for every 200 square metres or part thereof up\n\t\t\t\tto 1,000 square metres and one additional unit for every 100\n\t\t\t\tsquare metres of floor area over 1,000 square metres.\n(d) Restaurants.\n17.5\n(i)Restaurants with\n\t\t\t\tless than 50 seats – Nil.\n(ii) With 50 seats and over one unit for every\n\t\t\t\t20 seats or parts of 20 seats.\n(e) Hotels and Lodges.\n17.5\nOne for every 6 beds.\n(f) Cinemas and Public Halls including Community\n\t\t\t\tHall.\n(g) Kalyanamandapam, etc.\n17.5\nOne for every 20 square metres of site area.\n3.\nWarehousing and Wholesale stores.\nOne for every 500 square metres of floor area or\n\t\t\t\tpart thereof.\n4.\nPublic and Semi-public Offices.\n20\n(i)For building with\n\t\t\t\tfloor area less than 100 square metres – Nil.\n(ii) Floor area of 100 square metres and\n\t\t\t\tabove-one for every 200 square metres or part thereof.\n5.\nHospitals and Nursing Homes.\n17.5\nOne for every 15 beds,\n6.\nIndustries.\n30\n(i) Up to 100 square metres of floor area -Nil.\n\t\t\t\t(ii) With floor area over 100 square metres-one for every 200\n\t\t\t\tsquare metres.\n7.\nFor other uses, Institutions and Transport and Communication\n\t\t\t\tCentres.\nRequirements to be assessed by Commissioner in\n\t\t\t\tconsultation with Commissioner of Police and [Director of Town\n\t\t\t\tPlanning.]\nAppendix-L (See Special Rule 10(2) (d) of Multi-storeyed Buildings) Design Loads and other Forces For Design of Masonry Structures 1. Deadloads. - The deadload in a building shall comprise the weight of all walls, partitions, floors and roofs and shall include the weights of all other permanent constructions in the building. The dead load is determined adopting the dead weight of the construction material and as given in the following Table: -\nAppendix-L\n(See Special Rule 10(2) (d) of Multi-storeyed Buildings)\nDesign Loads and other Forces For Design of Masonry Structures\nDesign Loads and other Forces For Design of Masonry Structures",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "1",
"title": "1. Deadloads.",
"chapter": null,
"content": "(a) Description of construction materials -\n(a) Description of construction materials -\nWeight in kg/M2\nWeight in kg/M2\n(1)\nBrick in mud, lime or cement mortar.\n1,920\n(2)\nCoarsed rubble in lime or cement mortar.\n2,240\n(3)\nLaterite in lime mortar.\n2,000\n(4)\nConcrete in lime or cement mortar.\n(a) 19.20 (brick jelly (b) 2,240 (hard broken stone)\n(5)\nRandom rubble in lime or cement mortar.\n2,240\n(6)\nLimestone.\n2,400 to 2,640\n(7)\nSandstone.\n2,240 to 2,400\n(8)\nCuddapah slabs.\n2,720\n(9)\nAshlar.\n2,720\n(10)\nGranite stone.\n2,640 to 2,800\n(11)\nReinforced concrete.\n2,400\n(12)\nCast-iron.\n7,030 to 7,130\n(13)\nWrought-iron.\n7,700\n(14)\nSteel.\n7,850\n(15)\nTeak.\n625\n(16)\nPine.\n610\n(17)\nOak.\n865\n(18)\nFir.\n430 to 460\n(b) Description of roof materials and roofs.\nWeight in kg /M2\n(1)\nCorrugated iron sheet (1.25 mm).\n10.56\n(2)\nCorrugated iron sheet (1.00 mm).\n8.60\n(3)\nBrick in mud, lime or cement mortar.\n1,920\n(4)\nCoarsed rubble in lime or cement mortar.\n2,240\n(5)\nLaterite in lime mortar.\n2,000\n(6)\nConcrete in lime or cement mortar.\n(a) 19.20 (brick jelly,\n(b) 2,240 (hard broken Stone)\n(7)\nRandom rubble In lime or cement mortar.\n2,240\n(8)\nLime-stone.\n2,400\n(9)\nSand-stone.\n2,240 to 2,400",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "2",
"title": "2. Live loads.",
"chapter": null,
"content": "(ii) In designing the walls, columns, piers, their supports and foundations, the following reductions is assumed total live loads on floors may be made: -\nNumber of floors carried by member under\n\t\t\t\tconsideration\nNumber of floors carried by member under\n\t\t\t\tconsideration\nPer cent reduction of total live load on all\n\t\t\t\tfloor above the member under consideration\nPer cent reduction of total live load on all\n\t\t\t\tfloor above the member under consideration\n1\n0\n2\n10\n3\n20\n4\n30\n5 or more\n40\n(iii) No reduction shall be made in the case of warehouses, garages and other buildings used for storage purposes and for factories and workshops designed for 500 kg/M2.\nLive Loads On Floors\nLive Loads On Floors\nType of Floors\nType of Floors\nMinimum Live Loads per kg/m2 of floor area\nMinimum Live Loads per kg/m2 of floor area\nAlternative Minimum Live Load\nAlternative Minimum Live Load\n(1)\n(2)\n(3)\nFloors in dwelling houses, tenements, hospital\n\t\t\t\twards, bed-rooms and private sitting-rooms in hostels and\n\t\t\t\tdormitories.\n200\nOffice floors other than entrance halls, floors\n\t\t\t\tof light workrooms.\n250-400\nFloors of banking halls, office entrance halls\n\t\t\t\tand reading-rooms.\n300\nShop floors used for display and sale of\n\t\t\t\tmerchandise; floors of workrooms, generally floors of classrooms\n\t\t\t\tin schools, floors or places of assembly with fixed seating,\n\t\t\t\trestaurants, circulation space in machinery halls,\n\t\t\t\tpower-stations, etc., not occupied by plant or equivalent.\n400\nSubject to a minimum total load of 2.5 times the\n\t\t\t\tvalues in column 4 for any given slab panel and 6 times the\n\t\t\t\tvalues in column 4 for any given beam.\nFloors of warehouses, workshops, factories and\n\t\t\t\tother building or parts of buildings of similar category for\n\t\t\t\tlight-weight loads; office floors for storage and filing\n\t\t\t\tpurposes; floors of places of assembly without fixed seating,\n\t\t\t\tpublic rooms in hotels, dance-halls, waiting-halls, etc.\n500\nThis total load shall be assumed uniformly\n\t\t\t\tdistributed on the entire area of the slab panel or the entire\n\t\t\t\tlength of the beam.\nType of Floors\nType of Floors\nMinimum Live Loads per kg/m2 of floor area\nMinimum Live Loads per kg/m2 of floor area\nAlternative Minimum Live Load\nAlternative Minimum Live Load\n(1)\n(2)\n(3)\nFloors of warehouses, workshops, factories and\n\t\t\t\tother buildings or parts of buildings of similar category for\n\t\t\t\tmedium-weight loads.\n750\nFloors of warehouses, workshops, factories and\n\t\t\t\tother buildings or parts of buildings of similar category for\n\t\t\t\theavy-weight loads, floors of bookstores and libraries, roofs \n\t\t\t\tand pavement lights over basements projecting under the public\n\t\t\t\troof path under the public foot-path.\n1000\nFloors used for garages for vehicles not\n\t\t\t\texceeding 2.5 tonnes gross weight slabs.\n400\nThe worst combination of actual wheel loads,\n\t\t\t\twhichever is greater.\nBeams\n250\nThe worst combination of actual wheel loads,\n\t\t\t\twhichever is greater.\nFloors used for garages for vehicles not\n\t\t\t\texceeding 4 tonnes gross weight.\n750\nSubject to a minimum of one and a half times\n\t\t\t\tmaximum wheel load but not less than 900 kg. considered to be\n\t\t\t\tdistributed over 5 cm. square.\nStairs, landings and corridors for class 200\n\t\t\t\tloading but not liable to overcrowding\n300\nSubject to minimum of 130 kg. concentrated load\n\t\t\t\tat the unsupported end of each step for stairs constructed out of\n\t\t\t\tstructurally independent cantilever steps\nStairs, landings and corridors for class 200\n\t\t\t\tloading but liable to overcrowding, and for all other classes.\n500\nBalconies not liable to over-crowding:\nFor class 200 loading\n300\nFor all other classes\n500\nBalconies liable to overcrowding:\n500\n(b) Live loads on roofs. - Allowance for live load on flat roofs, sloping roofs and curved roofs shall be as given in the following Table: -\n(b) Live loads on roofs.\nTable\nTable\nLive Loads on Floors\nLive Loads on Floors\nType of roofs\nType of roofs\nLive Loads measured on plain\nLive Loads measured on plain\nMinimum live load measured on plan\nMinimum live load measured on plan\n(1)\n(2)\n(3)\nFlat, sloping or\n\t\t\t\tcurved roof with slopes up to and including 10 degrees.\n(a) Access provided\n150kg./m2\n375 kg. uniformly distributed over any span of\n\t\t\t\tone metre width of the roof slab and 900 kg. uniformly\n\t\t\t\tdistributed over the span in the case of all beams.\n(b) Access not provided except for maintenance.\n75kg/m2\n190 kg. uniformly distributed over any span of\n\t\t\t\tone metre width of the roof slab and 450 Kg. uniformly\n\t\t\t\tdistributed over the span in the case of beam.\nSloping roof with slope greater than 10 degrees\n(a) For roof membrane sheets of purline 75 kg./\n\t\t\t\tm 2 ; less 2 kg./ m 2 for every degree increase in slope over 10\n\t\t\t\tdegrees.\n(b) For members supporting the roof membrane and\n\t\t\t\troof purlines, such as trusses, beams girders, etc.- 2/3 of load\n\t\t\t\tin (a).\nSubject to a minimum of 40 kg/m 2\n(c) Loads in, (a) and (b) do not include loads\n\t\t\t\tdue to snow, rain, dust collection, etc., and the effects of such\n\t\t\t\tloads shall be appropriately considered.\nCurved roofs with slope at springing greater\n\t\t\t\tthan 10 degrees.\n(75-345 r2 kg./m2 Where r = h/ 1 h = the height\n\t\t\t\tof the highest point of the structure measured from its springing\n\t\t\t\tand 1 = chord width of the roof in singly curved and shorter of\n\t\t\t\tthe two sides, if doubly curved.\nSubject to a minimum of 40 kg./m2\nNote. - For special types of roofs with highly permeable and absorbent material, the contingency of roof material increasing in weight due to absorption of moisture shall be provide for.\nNote.\n(c) Impact and vibrations. - For structure carrying live loads which reduce impact or of vibrations, the live load shall be increased as follows:1\n(c) Impact and vibrations.\n(i) For flame supporting lifts and hoists - 100 per cent.\n(ii) For foundations, footings and piers supporting lifts and hoisting apparatus - 40 per cent.\n(iii) For' light machinery, shaft or motor units - 20 per cent minimum.\n(iv) For reciprocating machinery or power units - 50 per cent minimum.",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "3",
"title": "3. Wind load.",
"chapter": null,
"content": "(1) Basic wind pressures for the City. -\nHeight in Metres\nHeight in Metres\nPressure in kg./m2\nPressure in kg./m2\n(1)\n(1)\n(2)\n(2)\nup to 30\n200\n35\n208\n40\n210\n45\n217\n50\n222\n60\n230\n70\n236\n80\n244\n100\n254\n120\n264\n150\n276\n(2) Wind pressures on roofs.\nWind Pressures on Roofs\nWind Pressures on Roofs\n(Wind normal and ridges)\nSlope of roof on\nSlope of roof on\nExternal\nExternal\nWind pressure\nWind pressure\n(1)\n(1)\n(2)\n(2)\n(3)\n(3)\nWindward side\nWind ward slope\nLeeward slope\n0°\n-1.00 P\n- 0.50 P\n10°\n-0.70 P\n- 0.50 P\n20°\n-0.40 P\n- 0.50 P\n30°\n- 0.10 P\n- 0.50 P\n40°\n+ 0.10P\n- 0.50 P\n50°\n+ 0.30 P\n- 0.50 P\n60°\n+ 0.30 P\n- 0.50 P\n70°\n+ 0.50 P\n- 0.50 P\n80°\n+ 0.50 P\n- 0.50 P\n90°\n+ 0.50 P\n- 0.50 P",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "4",
"title": "4. Seismic loads.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 21
}
],
"metadata": {
"Act ID": "tn282",
"Act Number": "Published vide Notification No. G.O. MS. No. 1769, Rural Development and Local Administration, dated 24th August, 1973 - S.R.O. A-914 of 1973",
"Enactment Date": "",
"Act Year": "1973",
"Short Title": "Multi-Storeyed and Public Buildings Rules, 1973",
"Type": "STATE",
"Location": "Tamil Nadu"
},
"updated_at": "2026-09-29 21:55:21"
}