← Back to Directory
Merchant Shipping (Seafarer Accommodation) Rules, 2016
Merchant Shipping (Seafarer Accommodation) Rules, 2016
Sections
1. Short title, commencement and application.
Section 12. Definitions.
Section 24. Seafarer accommodation.
Section 45. Plans.
Section 56. Certification and verification.
Section 67. Application of relevant provisions of Maritime Labour Convention 2006 to ships other than Indian ships.
Section 78. Equivalent arrangements.
Section 81. General requirements for accommodation:
Section 12. Ventilation, Air-conditioning and Heating.
Section 23. Lighting.
Section 34. Sleeping Accommodation.
Section 45. Mess Rooms.
Section 56. Sanitary facilities:
Section 67. Hospital accommodation:
Section 78. Miscellaneous.
Section 89. Recreation facilities:
Section 910. Maintenance and Inspection of Seafarer Accommodation.
Section 1011. Prevention of noise and vibration.
Section 1112. Galleys, Provision rooms, cold storage, refrigerating equipment.
Section 12
merchant-shipping-seafarer-accommodation-rules-2016.json
•
19 Sections
•
India (Central)
{
"id": 10524,
"slug": "merchant-shipping-seafarer-accommodation-rules-2016",
"title": "Merchant Shipping (Seafarer Accommodation) Rules, 2016",
"short_title": "Merchant Shipping (Seafarer Accommodation) Rules, 2016",
"act_number": "Published vide Notification No. G.S.R. 824(E), 26t",
"act_year": 2016,
"act_type": "CENTRAL",
"location": "India (Central)",
"law_status": "unknown",
"enactment_date": null,
"description": "Merchant Shipping (Seafarer Accommodation) Rules, 2016",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "1. Short title, commencement and application.",
"chapter": null,
"content": "Explanation 1.\nExplanation 2.",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "2",
"title": "2. Definitions.",
"chapter": null,
"content": "(a) \"Act\" means the Merchant Shipping Act, 1958 (44 of 1958);\n(b) \"approved\" means approved or accepted by the Directorate;\n(c) \"Directorate\" means the office of the Director General or a person or a body of persons so authorised to act on behalf of the Director General by the Central Government;\n(d) \"gross tonnage\" means the measure of the overall size of a ship determined in accordance with the Merchant Shipping (Tonnage Measurement of ships) Rules,1987.\n(e) \"Merchant Shipping Notice\" means a notice described as such and issued by the Directorate;\n(f) \"new ship\" means a ship constructed on or after coming into force of these rules;\n(g) \"Schedule\" means the Schedule annexed to these rules;\n(h) \"ship-owner\" means the owner of a ship, or any body of persons or any person such as the manager, agent or bareboat charterer, who has assumed the responsibility for operation of the ship from such owner and who, on assuming such responsibility, has agreed to take over the duties and responsibilities imposed on such owner in accordance with these rules, regardless of whether any other body of persons or persons fulfill certain of the duties or responsibilities on behalf of the owner of a ship.;\n(i) \"special purpose ships\" means ships constructed in compliance with the Special Purpose Ships Code (IMO Code of Safety for Special Purpose Ships, 1983, and its subsequent versions);\n(j) \"surveyor\" means a surveyor appointed under section 9 of the Act;\n(k) \"trunked mechanical ventilation system\" means a system of ventilation complying with the specifications set forth in the Second Schedule\n(l) \"washing accommodation\" does not include any sleeping room or hospital ward, whether or not provided with a wash basin, bath or shower; or any room appropriated for use only as a laundry.\n3.",
"footnote": "",
"is_definition": true,
"sort_order": 1
},
{
"number": "4",
"title": "4. Seafarer accommodation.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "5",
"title": "5. Plans.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "6",
"title": "6. Certification and verification.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "7",
"title": "7. Application of relevant provisions of Maritime Labour Convention 2006 to ships other than Indian ships.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "8",
"title": "8. Equivalent arrangements.",
"chapter": null,
"content": "First Schedule\n( See rule 4)",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "1",
"title": "1. General requirements for accommodation:",
"chapter": null,
"content": "(b) In passenger ships and special purpose ships (SPS), the Director General may, on condition that satisfactory arrangements are made for lighting and ventilation, permit the location of sleeping rooms below the load line, but in no case shall they be located immediately beneath working alleyways.\n(c) There shall be adequate headroom in all seafarer accommodation; the minimum permitted headroom in all seafarer accommodation where full and free movement is necessary shall be not less than 203 centimeters. The Director General may permit some limited reduction in headroom in any space, or part of any space, in such accommodation where he is satisfied that such reduction,-\n(i) is reasonable; and\n(ii) shall not result in discomfort to the seafarers.\n(b) Sleeping rooms, mess rooms, recreation rooms and alleyways in the accommodation space shall be adequately insulated to prevent condensation and overheating.\n(c) The bulkhead surfaces and deck heads shall be of material with a surface easily kept clean. No form of construction likely to harbour vermin shall be used.\n(d) The bulkhead surfaces and deck heads in sleeping rooms and mess rooms shall be capable of being easily kept clean and light in colour with a durable, non-toxic finish.\n(e) The decks in all seafarer accommodation shall be of approved material and construction and shall provide a non-slip surface impervious to damp and easily kept clean.\n(f) Where the floorings are made of composite materials, the joints with the sides shall be profiled to avoid crevices.\n(g) The materials used to construct internal bulkheads, paneling and sheeting, floors and joining shall be suitable for the purpose and conducive to ensure a healthy environment.\n(h) In every ship to which these rules apply, all bulkheads enclosing or within any part of the seafarer accommodation shall be properly constructed of steel or other suitable material. If the bulkheads are exposed to the weather, they shall be of watertight and gastight construction, and means of closure shall be provided for all openings in such bulkheads so as to enable them to be made weather tight.\n(i) There shall be no direct openings into sleeping rooms from cargo spaces or machinery spaces or from galleys, store rooms, drying rooms or communal sanitary areas. That part of a bulkhead separating such spaces from sleeping rooms and external bulkheads shall be efficiently constructed of steel or other approved substance and be watertight and gas-tight.\n(b) Chain pipes, and ventilator trunks to cargo spaces or tanks, where they pass through any part of the seafarer accommodation, shall be made of steel or other suitable material and shall be gastight.\n(c) Batteries for the operation of the ship's radio installation or other purposes, shall not be placed in any sleeping room provided for the seafarer, and precautions shall be taken which will ensure that fumes from such batteries do not discharge into any part of the seafarer accommodation.\n(d) Any part of the seafarer accommodation which is adjacent to any part (other than the crown) of a tank in which oil may be carried in bulk, shall be separated there from by a gastight steel division, in addition to the division which retains the oil.\n(e) If any part of the seafarer accommodation is situated on a deck which forms the crown of a space in which oil may be carried in bulk, such deck shall be oil tight. No manholes or other openings to the oil tanks shall be situated in the seafarer accommodation.\n(f) The means of access to and egress from every part of the seafarer accommodation shall be so situated that in the event of fire in any lamp room or paint room in the ship, access to and egress from the seafarer accommodation shall not be impeded.\n(b) There shall be no drainage from any source (not being sanitary accommodation) into the sanitary accommodation forming part of the seafarer accommodation.\n(b) No space forming part of the seafarer accommodation of a ship to which these rules apply, shall be marked whether inside or outside with any marking which may be taken to indicate that the space is appropriated for use by persons differing in number of description from the persons for whose use the space has been certified by a surveyor.\n(b) Provision may also be made for the availability of cold drinking water in close proximity to the spaces where watch-keeping seafarers are on duty.\n(c) The storage, filling and distribution arrangements for drinking water shall be such as to prevent any possible contamination. A dry space, such as cofferdam, shall be provided between drinking water tanks and other tanks such as oil tanks and sewage tanks. Drinking water tanks shall not contain any piping other than that necessary for the carriage and distribution of drinking water. Air, filling and sounding pipes shall stand sufficiently above the deck.",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "2",
"title": "2. Ventilation, Air-conditioning and Heating.",
"chapter": null,
"content": "(b) Ships, except those regularly engaged in trade where temperate climatic conditions do not require this, shall be equipped with air conditioning for seafarer accommodation, for separate radio room and for any centralised machinery control room. Ships below 200 gross tons are exempted from this requirement subject to provision of trunked mechanical ventilation.\n(c) All sanitary spaces shall have ventilation to the open air independently of any other part of the accommodation.\n(d) The system of ventilation for sleeping rooms and mess rooms shall be controlled so as to maintain the air in a satisfactory condition and to ensure sufficiency of air movement in all conditions of weather and climate.\n(e) Air-conditioning systems whether of a centralised or individual unit type, shall be designed to,-\n(i) maintain the air at a satisfactory temperature and relative humidity as compared to outside air conditions, ensure a sufficiency of air changes in all air-conditioned spaces, take account of the particular characteristics of operations at sea and not produce excessive noises or vibrations; and\n(ii) facilitate easy cleaning and disinfection to prevent or control the spread of disease.\n(f) Power for the operation of the air conditioning and other aids to ventilation required by the preceding paragraphs of this Schedule shall be available at all times when seafarers are living or working on board and conditions so require. However, this power need not be provided from an emergency source.\n(g) Ships, which are exclusively engaged in trade outside tropical climate areas, shall be provided with a ventilation system which will maintain the air therein in a state of purity adequate for the health and comfort of the seafarer. Such system shall be capable of being so controlled as to ensure a sufficiency of air movement under all conditions of weather and climate to which the ship is likely to be subjected during the voyages on which she is intended to be engaged and shall be additional to any side scuttles, skylights, companions, doors or other apertures not intended solely for ventilation.\n(h) The trunked mechanical system provided on a ship shall comply with the requirements specified at Second Schedule.\n(i) Every enclosed space forming part of the seafarer accommodation of a ship, being a space not fully airconditioned or not ventilated by a trunked mechanical ventilation system, shall be provided with a natural system of inlet and exhaust ventilation.\n(j) In the seafarer accommodation of every ship, being a ship not fully air conditioned, an electric fan shall be fitted in every sleeping room, mess room, recreation room, office, Galley and pantry.\n(i) maintain the air at a satisfactory temperature of 28º with 50 per cent relative humidity when ambient temp is 35ºC with 70 per cent relative humidity;\n(ii) ensure eight air changes per hour in any mess room or recreation room and six air changes in any other room, the amount of re-circulated air not exceeding 50 per cent at any stage, while at sea;\n(iii) take into account particular characteristics of operations at sea so as to avoid producing objectionable noises or vibrations; and\n(iv) facilitate easy cleaning and disinfection to prevent and control of spread of disease.\n(b) The system of heating the seafarer accommodation, when required under these rules, shall be in operation at all times when seafarers are living or working on board and conditions require its use:\n(c) In all ships in which a heating system is required, the heating should be by means of hot water, warm air, electricity, steam or equivalent. However, within the accommodation area, steam shall not be used as a medium for heat transmission. The heating system shall be capable of maintaining the temperature in seafarer accommodation at a satisfactory level under normal conditions of weather and climate likely to be met within the trade in which the ship is engaged.\n(d) Radiators and other heating apparatus shall be placed and, where necessary, shielded so as to avoid risk of fire or danger or discomfort to the occupants.",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "3",
"title": "3. Lighting.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "4",
"title": "4. Sleeping Accommodation.",
"chapter": null,
"content": "(a) in ships other than passenger ships, an individual sleeping room shall be provided for each seafarer.\n(i) for ships between 3000 gross tons and 500 gross tons: Master, Chief Engineer, navigating and engineer officers in charge of a watch-1 person per room.\n(ii) for ships below 500 gross tons: Master and Chief Engineer-1 person per room\n(iii) seafarers other than (i) and (ii) above: Not more than 2 persons per room.\n(b) Separate sleeping rooms shall be provided for men and women.\n(c) Sleeping rooms shall be of adequate size and properly equipped so as to ensure reasonable comfort and to facilitate tidiness.\n(d) A separate berth for each seafarer shall in all circumstances be provided.\n(e) The minimum inside dimensions of a berth shall be at least 198 centimetres by 80 centimetres.\n(f) In single berth seafarers' sleeping rooms the floor area shall not be less than-\n(i) 4.5 square metres in ships of less than 3,000 gross tonnage;\n(ii) 5.5 square metres in ships of 3,000 gross tonnage or over but less than 10,000 gross tonnage; and\n(iii) 7 square metres in ships of 10,000 gross tonnage or over.\n(g) However, in order to provide single berth sleeping rooms on ships of less than 3,000 gross tonnage, passenger ships and special purpose ships, the Director General of Shipping may allow a reduced floor area;\n(h) In ships of less than 3,000 gross tonnage other than passenger ships and special purpose ships, sleeping rooms may be occupied by a maximum of two seafarers; the floor area of such sleeping rooms shall not be less than 7 square metres.\n(i) On passenger ships and special purpose ships, the floor area of sleeping rooms for seafarers not performing the duties of ships' officers shall not be less than:-\n(I) 7.5 square metres in rooms accommodating two persons;\n(II) 11.5 square metres in rooms accommodating three persons; and\n(III) 14.5 square metres in rooms accommodating four persons.\n(j) On special purpose ships, sleeping rooms may accommodate more than four persons; the floor area of such sleeping rooms shall not be less than 3.6 square metres per person.\n(k) On ships other than passenger ships and special purpose ships, sleeping rooms for seafarers who perform the duties of ships' officers, where no private sitting room or day room is provided, the floor area per person shall not be less than-\n(i) 7.5 square metres in ships of less than 3,000 gross tonnage;\n(ii) 8.5 square metres in ships of 3,000 gross tonnage or over but less than 10,000 gross tonnage; and\n(iii) 10 square metres in ships of 10,000 gross tonnage or over.\n(l) On passenger ships and special purpose ships the floor area for seafarers performing the duties of ships' officers where no private sitting room or day room is provided, the floor area per person for junior officers shall not be less than 7.5 square metres and for senior officers not less than 8.5 square metres; junior officers are understood to be at the operational level, and senior officers at the management level.\n(m) On ships of 3000 gross tons and above, the master, the chief engineer and the chief navigating officer shall have, in addition to their sleeping rooms, an adjoining sitting room, day room or equivalent additional space consideration shall be given to the second engineer officer when practicable.\n(n) For each occupant, the furniture shall include a clothes locker of ample space (minimum 475 litres) and a drawer or equivalent space of not less than 56 litres; if the drawer is incorporated in the clothes locker then the combined minimum volume of the clothes locker shall be 500 litres; it shall be fitted with a shelf and be able to be locked by the occupant so as to ensure privacy.\n(o) Each sleeping room shall be provided with a table or desk, which may be of the fixed, drop-leaf or slide-out type, and with comfortable seating accommodation as necessary.\n(p) There shall be adequate berth arrangements on board, making it as comfortable as possible for the seafarer and any partner who may accompany the seafarer.\n(q) Where the size of the ship, the activity in which it is to be engaged and its layout make it reasonable and practicable, sleeping rooms shall be planned and equipped with a private bathroom, including a toilet, so as to provide reasonable comfort for the occupants and to facilitate tidiness.\n(r) As far as practicable, sleeping rooms of seafarers shall be so arranged that watchers are separated and that no seafarers working during the day share a room with watchkeepers.\n(s) In the case of seafarers performing the duty of petty officers there shall not be more than two persons per sleeping room.\n(t) Space occupied by berths and lockers, chests of drawers and seats shall be included in the measurement of the floor area. Small or irregularly shaped spaces which do not add effectively to the space available for free movement and cannot be used for installing furniture shall be excluded.\n(u) Berths shall not be arranged in tiers of more than two. In the case of berths placed along the ship's side, there should be only a single tier where a sidelight is situated above a berth.\n(v) The lower berth in a double tier should be not less than 30 centimeters above the floor; the upper berth should be placed approximately midway between the bottom of the lower berth and the lower side of the deck head beams.\n(w) The framework and the lee-board, if any, of a berth should be of approved material, hard, smooth, and not likely to corrode or to harbour vermin.\n(x) If tubular frames are used for the construction of berths, they should be completely sealed and without perforations which would give access to vermin.\n(y) Each berth should be fitted with a comfortable mattress with cushioning bottom or a combined cushioning mattress, including a spring bottom or a spring mattress. The mattress and cushioning material used should be made of approved material. Stuffing of material likely to harbour vermin should not be used.\n(z) When one berth is placed over another, a dust-proof bottom should be fitted beneath the bottom mattress or spring bottom of the upper berth.\n(za) The furniture should be of smooth, hard material not liable to warp or corrode.\n(zb) Sleeping rooms should be fitted with curtains or equivalent for the sidelights.\n(zc) Sleeping rooms should be fitted with a mirror, small cabinets for toilet requisites, a book rack and a sufficient number of coat hooks.\n(zd) A curtain shall be fitted to each bed, unless the room accommodates only one person.",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "5",
"title": "5. Mess Rooms.",
"chapter": null,
"content": "(a) master and officers; and\n(b) petty officers and other seafarers.\n(a) a refrigerator, which should be conveniently situated and of sufficient capacity for the number of persons using the mess room or mess rooms;\n(b) facilities for hot beverages; and\n(c) cool water facilities.\n(a) a storage locker;\n(b) supply of cold drinking water;\n(c) means of heating drinking water for hot beverages; and\n(d) a microwave oven.",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "6",
"title": "6. Sanitary facilities:",
"chapter": null,
"content": "(a) Floors should be of approved durable material, impervious to damp, and should be properly drained.\n(b) Bulkheads should be of steel or other approved material and should be watertight up to at least 23 centimeters above the level of the deck:\n(c) The accommodation should be sufficiently lit, heated and ventilated.\n(d) Toilets should be situated convenient to, but separate from, sleeping rooms and wash rooms, without direct access from the sleeping rooms or from a passage between sleeping rooms and toilets to which there is no other access; this requirement does not apply where a toilet is located in a compartment between two sleeping rooms having a total of not more than four seafarers; and\n(e) Where there is more than one toilet in a compartment, they should be sufficiently screened to ensure privacy.\n(a) washing machines;\n(b) drying machines or adequately heated and ventilated drying rooms; and\n(c) irons and ironing boards or their equivalent.",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "7",
"title": "7. Hospital accommodation:",
"chapter": null,
"content": "(i) a clothes locker approximately 30 centimeter square by 61 centimeters high, and fitted with a flat top and a shelf; and\n(ii) an electric bell-pushes so arranged as to be within reach of each bed and communicating with the sleeping room of a person in charge of the patients and the bridge.",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "8",
"title": "8. Miscellaneous.",
"chapter": null,
"content": "(a) located outside the machinery space but with easy access to it; and\n(b) fitted with individual clothes lockers as well as with tubs or showers or both and wash basins having hot and cold running fresh water.\n(i) clean bedding and mess utensils should be supplied by the ship-owner to all seafarers for use on board during service on the ship, and such seafarers should be responsible for their return at times specified by the master and on completion of service in the ship;\n(ii) bedding should be of good quality, and plates, cups and other mess utensils should be of approved material which can be easily cleaned; and\n(iii) towels, soap and toilet paper for all seafarers should be provided by the ship-owner.\n(b) Any door to which such screens are fitted being a door at the entrance to a permanent or temporary hospital in a ship to which these paragraph apply, shall be of a self-closing type.",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "9",
"title": "9. Recreation facilities:",
"chapter": null,
"content": "(a) smoking room;\n(b) television viewing and the reception of radio broadcasts;\n(c) showing of films, the stock of which should be adequate for the duration of the voyage and, where necessary, changed at reasonable intervals;\n(d) sports equipment including exercise equipment, table games and deck games;\n(e) facilities for swimming;\n(f) a library containing vocational and other books, the stock of which should be adequate for the duration of the voyage and changed at reasonable intervals;\n(g) facilities for recreational handicrafts;\n(h) electronic equipment such as a radio, television, video recorders, digital video disc or compact disc player, personal computer and software and cassette recorder or player;\n(i) where appropriate, the provision of bars on board for seafarers unless these are contrary to national, religious or social customs; and\n(j) reasonable access to ship-to-shore telephone communications, and e-mail and Internet facilities, where available, with any charges for the use of these services being reasonable in amount.",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "10",
"title": "10. Maintenance and Inspection of Seafarer Accommodation.",
"chapter": null,
"content": "(b) The Master of the ship, or an officer appointed by him for the purpose, accompanied by one or more members of the seafarer, shall inspect every part of the seafarer accommodation at least once in two weeks to ensure that seafarer accommodation is clean, decently habitable and maintained in a good state of repair. The results of each such inspection shall be recorded and be available for review. The Master of the ship shall cause to be entered in a book specially kept for the purpose a record of-\n(i) the time and date of the inspection;\n(ii) the names and ranks of the persons making the inspection; and\n(iii) particulars in which the seafarer accommodation or any part thereof was found by any of the persons making the inspection not to comply with these rules.\n(i) the ship is registered or re-registered in India ;\n(ii) any part of the seafarer accommodation in the ship undergoes substantial alterations or repairs ;\n(iii) the number of persons accommodated in any space is increased above that marked in accordance with sub-paragraph (11) of paragraph 1; and\n(iv) in the opinion of a Surveyor, there is reason to believe (whether or not in consequence of a complaint ) that any of the provisions of these rules has been contravened in respect of that ship, or that any condition subject to which the Directorate has exempted the ship from a requirement of these rules has not been satisfied;\n(v) a request for an inspection of the seafarer accommodation has been made to the Directorate or to the Mercantile Marine Department, by or on behalf of the ship-owner of the ship or of any organisation which appears to the representative of the ship-owners of Indian ships or of the seafarer concerned; or\n(vi) a complaint has been lodged with an officer duly authorised under section 176 of the Act and complies with the following requirements, namely:-\n(a) the complaint shall be in writing, signed by the Master or three or more members of the seafarer;\n(b) the complaint shall specify the respects in which it is alleged that the seafarer accommodation in the ship does not comply with these rules;\n(c) the complaint shall be lodged without undue delay; and\n(d) the complaint shall be lodged at least 24 hours before the ship is due to sail, unless the ship is in port for less than 24 hours.",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "11",
"title": "11. Prevention of noise and vibration.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "12",
"title": "12. Galleys, Provision rooms, cold storage, refrigerating equipment.",
"chapter": null,
"content": "(b) The galley shall be situated as near as may be to the mess rooms provided for the seafarer and any necessary equipment shall be provided to enable food to be served in the mess rooms under all weather conditions.\n(c) There shall be no direct opening between the galley and any sleeping room.\n(d) Every galley shall be provided with exhaust fans which will draw off fumes from the cooking appliances therein and discharge the fumes into the open air.\n(e) The floor of the galley shall be provided with gutters and with scuppers which shall be led overboard or to an enclosed tank served by mechanically operated suction pump. The position and number of the gutter and scuppers shall be such as will ensure the efficient drainage of the floor.\n(f) The cooking appliances in the galley shall be arranged in a manner which shall facilitate the cleaning of the galley.\n(g) All cupboards and dressers in the galley shall be made of material which is impervious to dirt and moisture and can easily be kept clean. All metal parts of the cupboards and dressers shall be rustproof. The bottoms of all cupboards and dressers in the galley shall either be flush with the deck or shall be so fitted as to enable the deck space beneath them to be readily accessible for cleaning.\n(h) Every galley shall be provided with such equipment as will enable food in sufficient quantity to be properly and readily prepared for the persons whom the galley is intended to serve, and the cooking utensils to be hygienically cleaned.\n(i) Every galley shall be provided with one or more cooking appliances with an oven or cooking range of adequate capacity.\n(b) Every dry provision store room shall be enclosed by bulkheads constructed of steel or other suitable material.\n(c) Access to every dry provision store room shall be obtained from a passageway, galley, pantry or another store room, or from a position on an open deck with, in so far as is reasonable and practicable in the circumstances, shall be a protected position.\n(d) Every dry provision store room shall be so situated, constructed and ventilated as to avoid deterioration of the stores through heat, draught, condensation or infestation by insects or vermin.\n(b) Access to every cold store room shall be obtained from a passageway, galley or pantry or from another store room.\nSecond Schedule\n[ See rule 2(1) (k)]\nTrunked Mechanical Ventilation System\nCategory\nSpace\nFresh air changes per hour\nVolume of fresh air for each person likely to use\n the room at any one time (m 3 /min)\n(1)\n(2)\n(3)\n(4)\nA\nSpaces other than those in category\n (C) in deck houses above the upper or shelter deck :-\n(1) outside rooms (other than rooms\n adjoining machinery casing)\n(2) inside rooms and rooms adjoining machinery casing\n10\n15\n1.42\n1.42\nB\nSpaces other than those in category\n (C) in side-to-side superstructures above the upper or shelter\n deck:\n(1) outside rooms (other than rooms\n adjoining machinery casing\n(2) inside rooms and rooms adjoining machinery casing\n12\n15\n1.42\n1.42\nC\nMess rooms, smoking rooms and\n recreation rooms (in each case above the upper or shelter decks):\n(1) not adjoining machinery casing\n(2) adjoining machinery casing\n15\n18\n0.71*\n0.71*\nD\nPassageways adjoining machinery casings\n4\nE\nRooms in between decks (including\n shelter between decks) of ships propelled by internal combustion\n machinery\n(1) Rooms clear of machinery casing\n(2) Rooms abreast of but not\n adjoining machinery casing\n(3) Rooms adjoining machinery casing (other than mess rooms,\n smoking rooms and recreation rooms)\n12\n12\n15\n1.42\n1.42\n1.7\n(4) Mess rooms, smoking rooms, and recreation rooms (in each\n case adjoining machinery casing)\n18\n0.71\nF\nRooms in tween decks\n (including shelter tween decks) of steamships :-\n(1) Rooms clear of machinery casing\n(2) Rooms abreast of, but not\n adjoining machinery casing.\n(3) Rooms immediately above\n machinery casing or abreast of and adjoining machinery casing\n (other than mess rooms, smoking rooms and recreation rooms)\n(4) Mess room, smoking rooms and recreation rooms (in each\n case adjoining machinery casing)\n12\n15\n18\n20\n1.42\n1.7\n1.7\n0.85**\nTable II\nCategory\nSpace\nFresh air change per hour\nSupply\nExhaust\n(1)\n(2)\n(3)\n(4)\nG\nGalleys\n20 (a)(b)\n40(b)\nH\nSanitary accommodation, drying rooms and pantries\n10\n20\nJ\nWards in permanent hospitals\n12 or such greater number as would result in the\n supply of not less than 1.42 cubic metres of fresh air per minute\n for each bed in the room.\n--\nK\nDry provision store rooms\nNot less than 10 and not more than 20\n--\n(a) if at least two sides of the galley are exposed to the weather.\n(b) The Central Government may exempt any ship from these requirements to the extent that it is satisfied that compliance therewith is unnecessary by reason of the insulation of the equipment in the galley, or by reason of the size of the galley.\nThird Schedule\n[ See Schedule 1, Para 1(11)(a)]\nCertified for (*) seafarer(s)\nCertified for [Chief Officer]/[Master]/[Chief Engineer]/[**]\nCertified for (*) officers.\nCertified for (*) [ratings]/[petty officer].\nFourth Schedule\n[ See Schedule 1,para3(3)]\nElectric Lighting\n(A) Sleeping Room and Day Room:\n(1)\nAt general measurement points\n50 lux\n(2)\nAt every Mirror\n200 lux\n(3)\nAt every seat at a writing deck or table\n150 lux\n(4)\nAt not less than half the seats (other than those mentioned in\n (3) above) in a sleeping room provided for use of more than one\n person\n150 lux\n(B) Mess Room\n(1)\nAt general measurement points\n100 lux\n(2)\nAt every table and sink\n150 lux\n(C) Recreational Rooms (including for watching films and\n television hobbies, and games room):\n(1)\nAt general measurement points\n50 lux\n(2)\nAt every recreational table\n100 lux\n(3)\nAt every seat at a writing deck or table\n150 lux\n(4)\nAt not less than half the seats (other than those mentioned in\n (3) above)\n150 lux\n(D) Hospital\n(1)\nAt general measurement points\n50 lux\n(2)\nAt any wash room\n200 lux\n(3)\nAt least one fixed lamp shall be installed in addition to the\n electric reading lamp required by subpara (2) of para 3 to be\n provided at the head of each bed.\n150 lux\n(E) Offices and Studies\n(1)\nAt general measurement points\n100 lux\n(2)\nAt every seat at writing desk or table\n200 lux\n(F) Sanitary Accommodation (including sanitary accommodation\n in hospital):\n(1)\nAt general measurement points\n50 lux\n(2)\nAt every Mirror\n200 lux\n(G) Laundries\n(1)\nAt general measurement points\n100 lux\n(H) Drying Room:\n(1)\nAt the center of spaces\n50 lux\n(I) Galley (including bakeries and pantries):\n(1)\nAt working positions\nThe light shall be so disposed as to ensure that shelves and\n cupboards receive the maximum amount of light\n300 lux\n(J) Dry Provision Store Room and Cold Store Room:\n(1)\nAt general measurement points\nThe light shall be so disposed as to ensure that shelves and\n cupboards receive the maximum amount of light\n100 lux\n(K) Passage ways companionways and covered deck recreation\n spaces:\n(1)\nAt general measurement points\n50 lux\nA light shall be placed -\n(a) at the\n head of each stairway, ladder and hatchway, and\n(b) at or\n near the lockers provided for oilskins or working clothes.\nFifth Schedule\nCertificate of Seafarer Accommodation\n[See rule 6]\nCertificate of Seafarer Accommodation\nCertificate No.\nIssued under the provisions of the\nMerchant Shipping (Seafarer Accommodation) Rules, 2016.\nUnder the authority of the Government of India\nName of Ship\nDistinctive Number or Call Sign\nIMO Number\nPort of Registry\nGross Tonnage\nDate of Keel Laid*\nType of Ship\n:\n.................................\nArea of Operation\n:\nUnlimited / Restricted (see Remarks)\nMaster\n:\npersons\nOfficer\n:\npersons\nPetty Officers\n:\npersons\nRatings\n:\npersons\nTotal\n:\npersons",
"footnote": "",
"is_definition": false,
"sort_order": 18
}
],
"metadata": {
"Act ID": "act2955",
"Act Number": "Published vide Notification No. G.S.R. 824(E), 26th August, 2016",
"Enactment Date": "",
"Act Year": "2016",
"Short Title": "Merchant Shipping (Seafarer Accommodation) Rules, 2016",
"Type": "CENTRAL",
"Location": "India (Central)"
},
"updated_at": "2026-09-29 21:55:17"
}