(b) The competent authority may, at any time, by written notice, require the owner of any building, which has an external roof or wall made of such material as aforesaid, to remove such roof or wall within such reasonable time as shall be specified in the notice, notwithstanding that the public notice has not been issued or that such roof or wall was made with the consent of the competent authority on or before the issue of such notice.
(a) brick-work constructed of bricks, well-burnt, hard and sound, properly bounded and solidly put together with
(i) mortar compounded of lime and sharp clean sand, hard clean broken brick, broken flint, grills or slag, well pulverised, or
(ii) cement mixed with any of the materials mentioned in sub-clause (i);
(b) granite or other stone which is suitable for building purposes by reasons of its solidity and durability;
(c) slate, tiles, bricks and terracotta, when used for coverings or corbels;
(d) flag-stones when used for floors over arches, if not exposed on the underside and if not supported at the ends only;
(e) concrete, composed of broken brick, stone chippings or selected slag and lime, cement or calcined gypsum, when the concrete is used for filling in between joists of floors to a depth of not less than ten centimetres;
(f) any combination of concrete, steel or iron or any other materials approved in this behalf from time to time by the Board of Councillors.
(a) sal, teak, and other hard timber, when used for beams or posts or in combination with steel, the timber and the steel (if any) being protected by plastering in cement or other incombustible or non-conducting external coating;
(b) in the case of staircases, sal, teak or other hard timber, not less than four centimetres thick; and
(c) in the case of staircases, sal, teak or other hard timber, the treads and risers being not less than four centimetres thick.
Section 41 • West Bengal Municipal (Building) Rules, 2007
41. Power as to inflammable structures.
west-bengal-municipal-building-rules-2007-sec-41.json
•
Section 41
{
"act_title": "West Bengal Municipal (Building) Rules, 2007",
"act_slug": "west-bengal-municipal-building-rules-2007",
"section_label": "Section",
"section": {
"number": "41",
"title": "41. Power as to inflammable structures.",
"chapter": null,
"content": "(b) The competent authority may, at any time, by written notice, require the owner of any building, which has an external roof or wall made of such material as aforesaid, to remove such roof or wall within such reasonable time as shall be specified in the notice, notwithstanding that the public notice has not been issued or that such roof or wall was made with the consent of the competent authority on or before the issue of such notice.\n(a) brick-work constructed of bricks, well-burnt, hard and sound, properly bounded and solidly put together with\n(i) mortar compounded of lime and sharp clean sand, hard clean broken brick, broken flint, grills or slag, well pulverised, or\n(ii) cement mixed with any of the materials mentioned in sub-clause (i);\n(b) granite or other stone which is suitable for building purposes by reasons of its solidity and durability;\n(c) slate, tiles, bricks and terracotta, when used for coverings or corbels;\n(d) flag-stones when used for floors over arches, if not exposed on the underside and if not supported at the ends only;\n(e) concrete, composed of broken brick, stone chippings or selected slag and lime, cement or calcined gypsum, when the concrete is used for filling in between joists of floors to a depth of not less than ten centimetres;\n(f) any combination of concrete, steel or iron or any other materials approved in this behalf from time to time by the Board of Councillors.\n(a) sal, teak, and other hard timber, when used for beams or posts or in combination with steel, the timber and the steel (if any) being protected by plastering in cement or other incombustible or non-conducting external coating;\n(b) in the case of staircases, sal, teak or other hard timber, not less than four centimetres thick; and\n(c) in the case of staircases, sal, teak or other hard timber, the treads and risers being not less than four centimetres thick.",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
"prev_section": "40",
"next_section": "42"
}