(b) Single brick thick, that is, 25 cm (10") load bearing wails, can be adopted up to three storied residential building if constructed in cement mortar of requisite proportion;
(c) in the case of residential buildings or flats where maximum height of rooms measured from the surface of the floor to the ceiling is restricted to 2.75 m (9'-0"), load bearing walls of 25 cm (10') thick can be adopted up to four stories buildings, provided good bricks of 70 kg/cm strength are used with cement mortar as specified by the National Building Code;
(d) every wall of masonry building which is exposed to external air shall, in no case, be less than 25 cm in thickness :
Section 142 • West Bengal Municipal (Building) Rules, 2007
142. Structural feature.
west-bengal-municipal-building-rules-2007-sec-142.json
•
Section 142
{
"act_title": "West Bengal Municipal (Building) Rules, 2007",
"act_slug": "west-bengal-municipal-building-rules-2007",
"section_label": "Section",
"section": {
"number": "142",
"title": "142. Structural feature.",
"chapter": null,
"content": "(b) Single brick thick, that is, 25 cm (10\") load bearing wails, can be adopted up to three storied residential building if constructed in cement mortar of requisite proportion;\n(c) in the case of residential buildings or flats where maximum height of rooms measured from the surface of the floor to the ceiling is restricted to 2.75 m (9'-0\"), load bearing walls of 25 cm (10') thick can be adopted up to four stories buildings, provided good bricks of 70 kg/cm strength are used with cement mortar as specified by the National Building Code;\n(d) every wall of masonry building which is exposed to external air shall, in no case, be less than 25 cm in thickness :",
"footnote": "",
"is_definition": false,
"sort_order": 142
},
"prev_section": "141",
"next_section": "143"
}