Appendix To The Rajasthan Boiler Rules, 1954
Appendix To The Rajasthan Boiler Rules, 1954
Form 'A'
Form 'A'
Register of Boiler
Register of Boiler
(Rule 8 the Rajasthan Boiler Rules, 1954)
Registry No.
Date of registration
Boiler rating
Type of boiler
Name and place of manufacture
Year of construction
Maker’s number and mark, if any
Name of owner
Place where in use
Remarks (transfer) etc.
1
2
3
4
5
6
7
8
9
10
Note. - These provisions as to effective disconnection shall extend to every case wherein a person is sent or with the assent of the owner or person-in-charge goes into a boiler for any purpose.
Form 'B'
Form 'B'
Indian Boilers Act, 1923
Indian Boilers Act, 1923
(V of 1923)
Notice for Examination of Boiler under Sections 7 and 8
Notice for Examination of Boiler under Sections 7 and 8
(Rule 33)
No.......of 19 . Chief Boiler Inspectors Office. Dated the...................... 19 .
.......................
......................
......................
(a) afford to the inspector all reasonable facilities for the examination and all such information as may be reasonably be required by him;
(b) have the boiler properly prepared and ready for examination in the prescribed manner; (See instruction on reverse)
(c) provide in the case of a boiler about to be registered such drawings, specification and certificates and other particulars as may be prescribed;
(d) produce to the inspector the last certificate of the boiler at the time of inspection.
Inspector of Boilers
(Reverse of Form B)
(See reverse for preparation required)
Preparation For Examination
Preparation For Examination
(a) Preparation for inspection
(b) Preparation for Hydraulic Test
Preparation now required
(A), (B),
Form 'C'
Form 'C'
General working of Boilers-Instructions for boiler attendants
General working of Boilers-Instructions for boiler attendants
(Rule 7)
General working of boilers-Instructions to boiler attendants.
Precautions before starting the fires.
(1) see that there is sufficient water in the boiler and that gauge cocks are working freely,
(2) ease safety valves, or open cock on top of boiler to allow air to escape,
(3) see that the blow-off cock is fully closed and tight,
(4) see that the safety valves and feed check valve are free and workable,
(5) see that water is not leaking from any part of the boiler,
(6) note if the pressure gauge pointer is at zero,
(7) see that the feed pump is in working order.
Raising steam.
Pressure gauge.
Steam pressure.
Low Water Safety Valves.
The Water Gauges.
Special note.
The blow off cock.
The scum cock.
Manhole and other door joints.
Steam pipes.
Scale and grease.
Grease.
Scale removal.
Treatment of feed water.
Preservation of boilers when not in use.
Special instruction for Boiler No..........
Inspector of Boilers
Form 'D'
Form 'D'
Accident Report under Section 18(1) of the Indian Boilers Act, 1923
Accident Report under Section 18(1) of the Indian Boilers Act, 1923
The Chief Inspector of Boilers,
Rajasthan, Jaipur
The undersigned begs to report that an accident occurred in the.................... Factory at ................... on dated ................... hour.............. causing slight/serious injury as detailed below:-
Section 68 • The Rajasthan Boilers Rules, 1954
68. Penalty.
the-rajasthan-boilers-rules-1954-sec-68.json
•
Section 68
{
"act_title": "The Rajasthan Boilers Rules, 1954",
"act_slug": "the-rajasthan-boilers-rules-1954",
"section_label": "Section",
"section": {
"number": "68",
"title": "68. Penalty.",
"chapter": null,
"content": "Appendix To The Rajasthan Boiler Rules, 1954\nAppendix To The Rajasthan Boiler Rules, 1954\nForm 'A'\nForm 'A'\nRegister of Boiler\nRegister of Boiler\n(Rule 8 the Rajasthan Boiler Rules, 1954)\nRegistry No.\nDate of registration\nBoiler rating\nType of boiler\nName and place of manufacture\nYear of construction\nMaker’s number and mark, if any\nName of owner\nPlace where in use\nRemarks (transfer) etc.\n1\n2\n3\n4\n5\n6\n7\n8\n9\n10\nNote. - These provisions as to effective disconnection shall extend to every case wherein a person is sent or with the assent of the owner or person-in-charge goes into a boiler for any purpose.\nForm 'B'\nForm 'B'\nIndian Boilers Act, 1923\nIndian Boilers Act, 1923\n(V of 1923)\nNotice for Examination of Boiler under Sections 7 and 8\nNotice for Examination of Boiler under Sections 7 and 8\n(Rule 33)\nNo.......of 19 . Chief Boiler Inspectors Office. Dated the...................... 19 .\n.......................\n......................\n......................\n(a) afford to the inspector all reasonable facilities for the examination and all such information as may be reasonably be required by him;\n(b) have the boiler properly prepared and ready for examination in the prescribed manner; (See instruction on reverse)\n(c) provide in the case of a boiler about to be registered such drawings, specification and certificates and other particulars as may be prescribed;\n(d) produce to the inspector the last certificate of the boiler at the time of inspection.\nInspector of Boilers\n(Reverse of Form B)\n(See reverse for preparation required)\nPreparation For Examination\nPreparation For Examination\n(a) Preparation for inspection\n(b) Preparation for Hydraulic Test\nPreparation now required\n(A), (B),\nForm 'C'\nForm 'C'\nGeneral working of Boilers-Instructions for boiler attendants\nGeneral working of Boilers-Instructions for boiler attendants\n(Rule 7)\nGeneral working of boilers-Instructions to boiler attendants.\nPrecautions before starting the fires.\n(1) see that there is sufficient water in the boiler and that gauge cocks are working freely,\n(2) ease safety valves, or open cock on top of boiler to allow air to escape,\n(3) see that the blow-off cock is fully closed and tight,\n(4) see that the safety valves and feed check valve are free and workable,\n(5) see that water is not leaking from any part of the boiler,\n(6) note if the pressure gauge pointer is at zero,\n(7) see that the feed pump is in working order.\nRaising steam.\nPressure gauge.\nSteam pressure.\nLow Water Safety Valves.\nThe Water Gauges.\nSpecial note.\nThe blow off cock.\nThe scum cock.\nManhole and other door joints.\nSteam pipes.\nScale and grease.\nGrease.\nScale removal.\nTreatment of feed water.\nPreservation of boilers when not in use.\nSpecial instruction for Boiler No..........\nInspector of Boilers\nForm 'D'\nForm 'D'\nAccident Report under Section 18(1) of the Indian Boilers Act, 1923\nAccident Report under Section 18(1) of the Indian Boilers Act, 1923\nThe Chief Inspector of Boilers,\nRajasthan, Jaipur\nThe undersigned begs to report that an accident occurred in the.................... Factory at ................... on dated ................... hour.............. causing slight/serious injury as detailed below:-",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
"prev_section": "67",
"next_section": "1"
}