(ii) Partition shall be made of fire-resisting material or of wood not less than 1¾ inch thick and certified by the Executive Engineer to be hard wood.
[(iii) The building shall have a roof. All ceilings and panelling shall be made of fire resisting material or from compressed or synthetic material treated against flaming which has been certified by the Executive Engineer to be suitable for the purpose intended.]
(iv) All floors including, landings and corridors with their supports shall be capable of supporting a static load of one hundred pounds per square floor and, as in alternative loading, every step or landing shall be strong enough to support a point load of three hundred pounds placed in any position.
(v) Where the first tier or gallery extends over the stalls, the height between the foot of the stalls and such tier or gallery shall not in any part be less than 10 feet; the height between the floor of the highest part of the gallery and the lowest part of the ceiling over the same shall not in any part be less than 12 feet, the height between any tier and the tier ceiling above it shall, in no case, be less than 8 feet.
Section 22 • The Punjab Cinemas (Regulation) Rules, 1952
22. Structural requirements.
the-punjab-cinemas-regulation-rules-1952-sec-22.json
•
Section 22
{
"act_title": "The Punjab Cinemas (Regulation) Rules, 1952",
"act_slug": "the-punjab-cinemas-regulation-rules-1952",
"section_label": "Section",
"section": {
"number": "22",
"title": "22. Structural requirements.",
"chapter": null,
"content": "(ii) Partition shall be made of fire-resisting material or of wood not less than 1¾ inch thick and certified by the Executive Engineer to be hard wood.\n[(iii) The building shall have a roof. All ceilings and panelling shall be made of fire resisting material or from compressed or synthetic material treated against flaming which has been certified by the Executive Engineer to be suitable for the purpose intended.]\n(iv) All floors including, landings and corridors with their supports shall be capable of supporting a static load of one hundred pounds per square floor and, as in alternative loading, every step or landing shall be strong enough to support a point load of three hundred pounds placed in any position.\n(v) Where the first tier or gallery extends over the stalls, the height between the foot of the stalls and such tier or gallery shall not in any part be less than 10 feet; the height between the floor of the highest part of the gallery and the lowest part of the ceiling over the same shall not in any part be less than 12 feet, the height between any tier and the tier ceiling above it shall, in no case, be less than 8 feet.",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
"prev_section": "21",
"next_section": "23"
}