(i) the pressure of the electric circuit shall not exceed 24 volts;
(ii) electric wiring shall-
(a) be heavily insulated and be adequate for maximum loads to be carried;
(b) be provided with suitable over-current protection in the form of fuses or automatic circuit breakers and installed so as to be protected from physical damage and contact with possible product spill either by location or by being encased in metal conduct or other oil resistant protective covering; and
(c) have all junction boxes sealed;
(iii) the generator, battery, switches, fuses and circuit brackets shall be carried in the cab of the vehicle or in the engine compartment and the battery shall be in an easily accessible position with a heavy-duty switch close by to cut-off the battery;
(iv) generators and motors and switches thereof which are not installed within the engine compartment shall be of the approved flame-proof type:
Section 71 • The Petroleum Rules, 2002
71. Electrical installation
the-petroleum-rules-2002-sec-71.json
•
Section 71
{
"act_title": "The Petroleum Rules, 2002",
"act_slug": "the-petroleum-rules-2002",
"section_label": "Section",
"section": {
"number": "71",
"title": "71. Electrical installation",
"chapter": null,
"content": "(i) the pressure of the electric circuit shall not exceed 24 volts;\n(ii) electric wiring shall-\n(a) be heavily insulated and be adequate for maximum loads to be carried;\n(b) be provided with suitable over-current protection in the form of fuses or automatic circuit breakers and installed so as to be protected from physical damage and contact with possible product spill either by location or by being encased in metal conduct or other oil resistant protective covering; and\n(c) have all junction boxes sealed;\n(iii) the generator, battery, switches, fuses and circuit brackets shall be carried in the cab of the vehicle or in the engine compartment and the battery shall be in an easily accessible position with a heavy-duty switch close by to cut-off the battery;\n(iv) generators and motors and switches thereof which are not installed within the engine compartment shall be of the approved flame-proof type:",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
"prev_section": "70",
"next_section": "72"
}