(b) Portable carbon dioxide fire extinguishers provided in compliance with these rules shall have a capacity of not less than 4.5 kg. of carbon dioxide.
(c) Portable dry powder fire extinguishers provided in compliance with these rules shall have a capacity of not less then 4.5 kg. of dry powder.
(d) Portable fire extinguishers of other types provided in compliance with these rules shall be of not less than the fire extinguishing equivalent of 9 litres fluid fire extinguisher.
(e) Portable fire extinguishers provided in compliance with these rules shall not exceed 25.5 kg. in weight in the fully charged condition and shall be as portable as a 13.5 litres fluid fire extinguisher.
(b) Notwithstanding the requirement of Cl. (a), portable dry powder fire extinguishers wherein the substance to extinguish fire is stored under pressure may be provided in compliance with these rules in either the accommodation or service spaces or in the machinery spaces, subject to their number not exceeding one half of the total number of extinguishers required to be provided in either of these spaces.
(a) the capacity of any fire extinguisher other than a carbon dioxide fire extinguisher shall be taken to be the greatest volume or weight of extinguishing medium which it can contain when sufficient space is left to ensure the proper operation of the extinguisher.
(b) the capacity of a carbon dioxide fire extinguisher shall be taken to be the greatest weight of carbon dioxide which it can safely contain in a tropical climate.
Section 39 • The Merchant Shipping (Fire Appliances) Rules, 1969
39. Fire extinguishers.
the-merchant-shipping-fire-appliances-rules-1969-sec-39.json
•
Section 39
{
"act_title": "The Merchant Shipping (Fire Appliances) Rules, 1969",
"act_slug": "the-merchant-shipping-fire-appliances-rules-1969",
"section_label": "Section",
"section": {
"number": "39",
"title": "39. Fire extinguishers.",
"chapter": null,
"content": "(b) Portable carbon dioxide fire extinguishers provided in compliance with these rules shall have a capacity of not less than 4.5 kg. of carbon dioxide.\n(c) Portable dry powder fire extinguishers provided in compliance with these rules shall have a capacity of not less then 4.5 kg. of dry powder.\n(d) Portable fire extinguishers of other types provided in compliance with these rules shall be of not less than the fire extinguishing equivalent of 9 litres fluid fire extinguisher.\n(e) Portable fire extinguishers provided in compliance with these rules shall not exceed 25.5 kg. in weight in the fully charged condition and shall be as portable as a 13.5 litres fluid fire extinguisher.\n(b) Notwithstanding the requirement of Cl. (a), portable dry powder fire extinguishers wherein the substance to extinguish fire is stored under pressure may be provided in compliance with these rules in either the accommodation or service spaces or in the machinery spaces, subject to their number not exceeding one half of the total number of extinguishers required to be provided in either of these spaces.\n(a) the capacity of any fire extinguisher other than a carbon dioxide fire extinguisher shall be taken to be the greatest volume or weight of extinguishing medium which it can contain when sufficient space is left to ensure the proper operation of the extinguisher.\n(b) the capacity of a carbon dioxide fire extinguisher shall be taken to be the greatest weight of carbon dioxide which it can safely contain in a tropical climate.",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
"prev_section": "38",
"next_section": "40"
}