(i) at least two fire hydrants, one on the port side and one on the starboard side and each such hydrant shall be provided with a fire hose with at least two nozzles one of which shall be capable of spraying water on oil or alternatively suitable dual purpose nozzles;
(ii) one froth type fire extinguisher of not less than 136 litres capacity or equivalent carbon dioxide extinguisher:
(iii) one portable froth type fire extinguisher for each 1,000 BHP or part thereof, but in no case less than two such extinguishers : Provided that not more than 6 such extinguishers need he carried in any one compartment;
(iv) a fixed fire extinguishing installation complying with the requirements of sub-rules (4) and (5) of rule 8.
Section 10 • The Merchant Shipping (Fire Appliances) Rules, 1969
10. Spaces containing internal cumbustion type of machinery.
the-merchant-shipping-fire-appliances-rules-1969-sec-10.json
•
Section 10
{
"act_title": "The Merchant Shipping (Fire Appliances) Rules, 1969",
"act_slug": "the-merchant-shipping-fire-appliances-rules-1969",
"section_label": "Section",
"section": {
"number": "10",
"title": "10. Spaces containing internal cumbustion type of machinery.",
"chapter": null,
"content": "(i) at least two fire hydrants, one on the port side and one on the starboard side and each such hydrant shall be provided with a fire hose with at least two nozzles one of which shall be capable of spraying water on oil or alternatively suitable dual purpose nozzles;\n(ii) one froth type fire extinguisher of not less than 136 litres capacity or equivalent carbon dioxide extinguisher:\n(iii) one portable froth type fire extinguisher for each 1,000 BHP or part thereof, but in no case less than two such extinguishers : Provided that not more than 6 such extinguishers need he carried in any one compartment;\n(iv) a fixed fire extinguishing installation complying with the requirements of sub-rules (4) and (5) of rule 8.",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
"prev_section": "9",
"next_section": "11"
}