27. Water Closets.

(a) officers and apprentice;
(b) petty officers;
(c) ratings, other than petty officers
Explanation.
(i) in determining the number of water closets no account shall be taken of any private water closet or the persons for whose use such private water closet is appropriated;
(ii) a water closet shall deemed to be private if it is appropriated for the exclusive use of not more than four persons;
(b) In addition to the water closets required by clause (a) three shall be provided such number of water closets, if any, as is required to increase the total number of water closets provided for the crew to the following scale :-
(c) In determining the number of water closets required by this sub-rule no account shall be taken of any water closet forming part of a permanent hospital.
(b) In every such ship, there shall also be provided a water closet and a wash basin having hot and cold running fresh water, within easy access of machinery spaces if such water closet is not fitted near engine room control center.
(a) another water closet,
(b) a urinal, or
(c) washing accommodation if the water closet is served by a trunked mechanical ventilation system which effectively removes odours therefrom.
(a) a water closet pedestal of single type with-
(i) a pan of white vitreous china or other suitable material;
(ii) a seat of polished hardwood or other suitable material with an opening of 10.2 centimetres at the front;
(iii) a trap with a metal inspection plate; and
(iv) an efficient ventilator connected to the out let;
(b) an adequate flush of water, which shall be always available and supplied through self-closing non-concussive supply valves with a portable seating in metal which is not likely to become corroded;
(c) a soil pipe not less than 10.2 centimetres in diameter so constructed as to facilitate cleaning and minimize the risk of obstruction;the pipe shall have a direct overboard outfall fitted with a strom-valve, unless sit is connected with a main sewage outfall by an efficient and hygienic system;
(d) a device for holding toilet paper;
(e) a hand rail or grip.
(a) Each battery of water closets may consist of any number of separate compartments contained in properly constructed steel house with a minimum height of 1.98 metres from top of foot holds to the under side of beams.
(b) The separate compartments in each battery shall be not less than 1.14 metres in length by 91.44 centimetres in width. Each such compartment shall have a separate entry fitted with a door with two shutters opening inwards which can be secured from the inside. The door need not extend to the full height of the compartment, but it shall not be less than 1.37 metres in height and 61.00 centimetres in width and the vertical height of the opening at the bottom shall not exceed 10.2 centimetres. The divisional bulk-heads between the compartments should extend to a height of within 30.5 centimetres should extend to a height of within 30.5 centimetres of the deck overhead and may also be opened at the bottom to the same extent and should be fitted with suitable hand grips. There shall be an enclosed passageway leading to the compartments of not less than 76.20 centimetres in breadth.
(c) Where convenient the floor of the compartment shall be raised to a height level with the top of the pan by means of a filling of cement or other similar material, or any other equivalent arrangement. If this method is adopted, the floor shall have al light declivity on all sides running down towards the pan.
(d) Every compartment shall be properly ventilated to the satisfaction of the surveyor by means of ventilators of such openings as will not interfere with privacy.
(e) Adequate lighting, either natural or electric, shall be provided to the satisfaction of the Surveyor, at all times during day and light.
(f) The pans shall preferably be made of white vitreous china or other suitable material. They shall be of an approved pattern complete with foot holds designed to prevent shipping. The orifice at the top of the pan shall be not less than 41.85 centimetres in length and not less than 23 centimetres in width. The pan shall be placed as low as practicable.
(g) An arrangement which automatically flushes the pan at intervals not exceeding 5 minutes and a continuous trickle of water.
(h) A soil pipe such as is referred to in clause (e) of sub-rule 9) provided with a metal inspection plate and sufficient ventilation.
(i) Each battery shall be provided with a tank to supply fresh water from the service stands for ablution purposes.