62. Operator.

(I) he possesses a minimum general education upto class VIII standard and has completed two years apprentice training in operation of Projector machine.
(II) he is thoroughly conversant with the municipal bye-laws and other rules relating to cinematograph exhibitions and precautions against fire;
(III) he is acquainted with the most speedy and effective method of dealing with fire;
(IV) he possess a fair knowledge of the elements of electric power, direct and alternating current, voltage, emperage, etc., and in the case of muffasi operators, a working knowledge of petrol and bill engines if such engines are over used for exhibitions;
(V) he is proficient in the handling, winding, repairing and efficient cleaning of films and
(VI) the certificate shall bear, affixed upon it, a certified photograph of the holder.
Part III
Rules for the Licensing of Temporary and Touring Cinemas
63.
64.
65.
66.
67.
68.
69.
(b) The provisions of the rules in Part II of these Rules shall apply mutatis mutandis to licenses for temporary and touring cinemas.
70.
Conditions
Conditions
A.
(2) Any electric wiring or terminals fitted within the casing shall be so paced that it shall be impossible for films in use in the projector to some in contact with them.
(3) Each electric circuit on the projector shall be fitted with a separate switch controlled from outside the casing, and so placed as to be within reach of the operator when standing at the projector.
(4) The heat of the illuminant, and its position in relation to the optical system, shall be such that it is impossible for the rays of light to gnite a stationary film.
B.
(2) The film-boxes fitted to the projector shall be so constructed as to be easily detachable from the apparatus.
(3) All films shall be contained in film-boxes, which shall be attachable to or removable from the projector without being opened, so that at no time shall a film be exposed except the portion necessary for threading up.
(4) During an exhibition, not more than three film Boxes (including the two actually attached to the projector) shall be in the enclosure on reserved space as the case may be, any one time. If further film-boxes are required they shall be kept in closed metal boxes outside the enclosure or reserved space as the case may be and if in the building, in a place approved by the Licensing Authority and subject to the prescribed requirements as to limitations of quantity and weight.
C.
(2) Resistances shall be made entirely of fire resisting materials, and shall be so constructed and maintained that no coil or other part at any time shall become unduly heated. If inside the auditorium, they shall be adequately projected by a wire guard of other efficient mean or preventing accidental contract, and shall not be placed within reach of persons in the audience.
(3) The operator shall satisfy himself before the commencement of each performance that all cables leads, connections, resistances and fuses are in proper working order. The resistances, if not under constant observation, shall be inspected at least once during each performance. If any fault is detected, current shall be immediately switched off, and shall remain switched off until the fault has been remedied.
(4) The projector circuit shall be independently protected by double-pole switch and fused properly enclosed and placed near the source of supply or the point of connection with the general lighting supply, as the case may be. Provided that, where the current does not exceed five amperes and the connection of the projector circuit to the general lighting supply is made by means of a connector as described in paragraph (5) below, such a connector may be used in substitution for a double pole switch.
(5) Where the projector circuit is connected to the general lighting supply, it shall be connected only at a point where the wires of the general lighting supply are of ample for the current they may have to carry and the connection shall be either by (a) securely made joints or connections or (b) a properly constructed wall type connector of hand shield type. It shall not be connected to any lighting fitting or by means of an adaptor to a lamp.
D. Rewinding of Films.
E. Emergency Lighting.
F. Location of Projector and Allied Apparatus.
(2) The projector shall be placed on a firm support Amateur Standard Apparatus. No projector other than an Amateur size projector shall be used on any premises within the auditorium unless provided with either a permanent or temporary enclosure.
(3) (i) Reserved Space. - If such an Amateur size projector be worked without an enclosure, it shall be situated within a space known as the 'Reserved Space' into which no person other than the operators shall be allowed during an exhibition. This space shall be ample for the operators and the necessary apparatus and safety utensils.
(ii) Five precautions in reserved space with Amateur Standard Projector. - One bucket of sand, one bucket of water and a blanket shall be kept within the reserved space.
(4) Full sixed apparatus. - Such apparatus, usually 36 M/M width or cover-shall, if placed within the auditorium or in any portion of the premises or where persons other than the operators resort during performances, only be used within the approved type of permanent enclosure or permanent cinemas or within the temporary enclosure of condition G. below:
(i) The verandah be of fire-resisting material in any part within ten feet of the apparatus.
(ii) No persons other that the operators, are allowed on the verandah within ten feet of the apparatus. The area so formed shall be a reserved space.
(iii) The doorway, window or other aperture through which the beam of light is projected be securely closed throughout the exhibition with a fire-resisting screen in which shall be not more than two orifices for the operation of the apparatus. Such orifices shall not be large than 8" by 8", and each shall be provided with a stout sheet of glass further protected a falling shutter of fire-resisting material in such a way that each can be instantly released by the operator in case of need.
(iv) Any other doorway, window or aperture within ten fee of the apparatus be entirely blocked with a fire-resisting screen in which there shall be no openings of any description.
(v) It a doorway be blocked under the provisions of sub- clauses (iii) and (iv) above, there shall be available other doorways in sufficient number and so placed as to ensure ready entrance and exit of the audience from the auditorium.
(vi) Fire precautions at the projector-No drapery and no unprotected combustible materials other than such materials as may compose the floor shall be within ten feet of the cinematograph; nor shall naked lights, matches or smoking utensils or tobacco be taken within the reserved space of (ii) above. Two chemical fire extinguishers, two buckets of water, one of which shall contain a large sponge and a blanket shall be kept at the projector.
G. Temporary Enclosure.
(1) Construction. - A some proof box constructed of sheet iron or steel on a substantial frame work and securely fastened together. The internal height from floor to roof shall be at least 8 feet. If one machine is to be operated the floor space shall not be less than 48 square feet. If more than one machine is to be operated therein an additional 24 square feet shall be' provided for each additional machine. The enclosure shall be otherwise itself conform in every other respect to a permanent enclosure:
(1) Construction.
(2) Electrical and other necessary apparatus. - All apparatus situated therein shall similarly conform to that in a permanent enclosure, subject to such apparatus being of a portable and not of a permanent fixed nature.
(2) Electrical and other necessary apparatus.
(3) General Working. - The requirements regarding care in working, Fire-fighting appliances, prohibition of inflammable materials, lights, matches, smoking utensils, film rewinding and admission of the public prescribed for permanent enclosure in permanent, cinemas shall apply to temporary enclosure for occasional exhibitions.
(3) General Working.
71.
72.
Part IV