← Back to Directory
The Legal Metrology (General) Rules, 2011
The Legal Metrology (General) Rules, 2011
Sections
1. Short title and commencement.
Section 12. Definitions.
Section 23. Reference standards.
Section 34. Secondary standards.
Section 45. Working standards.
Section 56. Power to specify any other reference, secondary or working standard.
Section 67. Reference standard balances.
Section 78. Secondary standard balances.
Section 89. Working standard balances.
Section 910. Power to specify the standard equipment.
Section 1011. Weights.
Section 1112. Measures (other than measuring instruments).
Section 1213. Weighing and measuring instruments.
Section 1314. Procedure for carrying out calibration of vehicle tanks, etc.
Section 1415. Registration of Importer.
Section 1516. Conditions, etc. for manufacture of a weight or measure exclusively for export.
Section 1617. Prohibition on sale of non-standard weight or measure within the country.
Section 1718. Maintenance of record in relation to non-standard weight or measure.
Section 1819. Sample checking of weight and measure.
Section 1920. Checking of non-standard weights and measures sample which are to be exported.
Section 2021. Permission to get manufactured non-standard weight or measure for scientific investigation or research.
Section 2122. The manner of disposal of goods seized under this Act/rule.
Section 2223. Time within which unverified weight and measure to be verified and stamped.
Section 2324. Register and reports to be maintained by persons referred to in Section 17 or the Act.
Section 1725. Scale of fee.
Section 2526. Use of regional languages.
Section 2627. Periodical verification of weights or measures.
Section 2728. Qualifications of Legal Metrology Officer.
Section 2829. Nomination of Director by a Company under the Act.
Section 2930. Repeal and savings.
Section 301. Denominations
Section 12. Materials
Section 23. Shape and finish
Section 34. Maximum permissible errors
Section 45. Protective and carrying case
Section 56. Inscription
Section 61. Material
Section 12. Shape and dimensions
Section 23. Finish
Section 34. Graduations
Section 45. Auxiliary scale
Section 56. Setting lines
Section 67. Maximum permissible error
Section 78. Inscription
Section 89. Protective and carrying case
Section 91. Denominations
Section 12. Materials
Section 23. Shape and finish
Section 34. Maximum permissible error
Section 45. Protective and carrying case
Section 56. Inscription
Section 61. Material
Section 12. Shape and dimensions
Section 23. Finish
Section 34. Graduations
Section 45. Auxiliary scale
Section 56. Maximum permissible error
Section 67. Inscription
Section 78. Protective find carrying case
Section 81. Denominations
Section 12. Material
Section 23. Shape
Section 34. Maximum permissible error
Section 45. Protective and carrying cases
Section 56. Inscriptions
Section 61. Denominations
Section 12. Material
Section 23. Shape and finish
Section 34. Maximum permissible error
Section 45. Protective and carrying case
Section 56. Inscription
Section 61. Material
Section 12. Shape and dimensions
Section 23. Finish
Section 34. Graduations
Section 45. Cursor
Section 56. Maximum permissible errors
Section 67. Inscription
Section 78. Protective and carrying case
Section 81. Denomination
Section 12. Material
Section 23. Shape
Section 34. Maximum permissible error
Section 45. Pipette measures
Section 56. Delivery time and maximum permissible errors of pipette measures
Section 67. Protective and carrying cases
Section 78. Inscriptions
Section 81. Denominations
Section 12. Shape
Section 23. Material
Section 34. Loading holes
Section 45. Markings
Section 56. Dimensions
Section 67. Finish
Section 78. Permissible error
Section 89. Stamping
Section 91. Denominations
Section 12. Shape
Section 23. Material
Section 34. Method of manufacture
Section 45. Loading hole
Section 56. Marking
Section 67. Dimensions
Section 78. Finish
Section 89. Permissible error
Section 910. Stamping
Section 101. Denominations
Section 12. Shape
Section 23. Material
Section 34. Method of manufacture
Section 45. Loading hole
Section 56. Marking
Section 67. Dimensions
Section 78. Finish
Section 89. Permissible error
Section 910. Stamping
Section 101. Denominations
Section 12. Shape
Section 23. Material
Section 34. Method of manufacture
Section 45. Loading holes
Section 56. Markings
Section 67. Dimensions
Section 78. Finish
Section 89. Permissible error
Section 910. Stamping
Section 101. Denominations
Section 12. Shape
Section 23. Material
Section 34. Method of manufacture
Section 45. Markings
Section 56. Dimensions
Section 67. Finish
Section 78. Permissible error
Section 89. Stamping
Section 91. General
Section 12. Denomination.
Section 23. Knob weights
Section 34. Sheet metal weights
Section 45. Manufacture and finish
Section 56. Marking
Section 67. Packing
Section 71. Scope
Section 12. Nominal values
Section 23. Shape
Section 34. Basis of adjustment
Section 45. Adjusting cavity
Section 56. Material
Section 67. Surface condition
Section 78. Metrological characteristics
Section 89. Inscriptions and markings
Section 910. Adjustment and verification
Section 1011. Dimensions
Section 111. General
Section 12. Denominations
Section 23. Shapes and dimensions
Section 34. Material
Section 45. Manufacture and finish
Section 56. Permissible error
Section 67. Marking
Section 78. Stamping
Section 81. General
Section 12. Types and denominations
Section 23. Materials
Section 34. Definition of capacity
Section 45. Shape, construction, etc. of conical measures
Section 56. Shape construction, etc. of beaker measures
Section 67. Marking
Section 78. Stamping
Section 81. General
Section 12. Types
Section 23. Denominations
Section 34. Material
Section 45. Shapes and dimensions
Section 56. Manufacture
Section 67. Permissible error
Section 78. Markings
Section 89. Stamping
Section 91. General
Section 12. Denominations
Section 23. Material, shape, etc. of metallic measures
Section 34. Material, shape, etc. of wooden measures
Section 45. Manufacture and finish
Section 56. Marking
Section 61. General
Section 12. Denominations
Section 23. Materials
Section 34. Manufacture
Section 45. Dimensions
Section 56. Graduations
Section 67. Permissible error
Section 78. Marking
Section 89. Stamping
Section 91. General
Section 12. Classes of accuracy
Section 23. Nominal lengths
Section 34. Material
Section 45. Manufacture
Section 56. Graduations
Section 67. Numbering
Section 78. Maximum permissible error
Section 89. Markings
Section 910. Sealing
Section 101. General
Section 12. Classes of accuracy
Section 23. Nominal lengths
Section 34. Materials
Section 45. Manufacture
Section 56. Graduations
Section 67. Numbering
Section 78. Maximum permissible error
Section 89. Markings
Section 910. Sealing
Section 101. General
Section 12. Definitions
Section 23. Material
Section 34. Constructional details
Section 45. Permissible error
Section 56. Marking
Section 67. Provision for stamping
Section 71. General
Section 12. Definitions
Section 23. Denominations
Section 34. Material
Section 45. Dip tape
Section 56. Dip weights
Section 67. Permissible error
Section 78. Marking
Section 81. General definitions
Section 12. Construction of an instrument
Section 23. Metrological characteristics of an instrument
Section 34. Metrological properties of an instrument
Section 45. Indications and errors
Section 56. Influence and reference conditions
Section 67. Performance test
Section 71. Scope
Section 12. Principles involved
Section 23. Metrological requirements
Section 3
the-legal-metrology-general-rules-2011.json
•
238 Sections
•
India (Central)
{
"id": 12282,
"slug": "the-legal-metrology-general-rules-2011",
"title": "The Legal Metrology (General) Rules, 2011",
"short_title": "The Legal Metrology (General) Rules, 2011",
"act_number": "Published vide Notification No. G.S.R. 71(E), date",
"act_year": 2011,
"act_type": "CENTRAL",
"location": "India (Central)",
"law_status": "unknown",
"enactment_date": null,
"description": "The Legal Metrology (General) Rules, 2011",
"preamble": "",
"section_label": "Section",
"sections": [
{
"number": "1",
"title": "1. Short title and commencement.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 0
},
{
"number": "2",
"title": "2. Definitions.",
"chapter": null,
"content": "(a) \"Act\" means the Legal Metrology Act, 2009 (1 of 2010);\n(b) \"Schedule\" means a Schedule appended to these rules;\n(c) \"Section\" means a Section of the Act;\n(d) words and expressions used in these rules and not defined but defined in the Act shall have the meanings respectively assigned to them in the Act.\nChapter II\nSpecifications of Standards of Weights and Measures",
"footnote": "",
"is_definition": true,
"sort_order": 1
},
{
"number": "3",
"title": "3. Reference standards.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 2
},
{
"number": "4",
"title": "4. Secondary standards.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 3
},
{
"number": "5",
"title": "5. Working standards.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 4
},
{
"number": "6",
"title": "6. Power to specify any other reference, secondary or working standard.",
"chapter": null,
"content": "Chapter III\nSpecifications of Standard Equipment",
"footnote": "",
"is_definition": false,
"sort_order": 5
},
{
"number": "7",
"title": "7. Reference standard balances.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 6
},
{
"number": "8",
"title": "8. Secondary standard balances.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 7
},
{
"number": "9",
"title": "9. Working standard balances.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 8
},
{
"number": "10",
"title": "10. Power to specify the standard equipment.",
"chapter": null,
"content": "Chapter IV\nWeights or Measures and Weighing and Measuring Instruments",
"footnote": "",
"is_definition": false,
"sort_order": 9
},
{
"number": "11",
"title": "11. Weights.",
"chapter": null,
"content": "(a) in any transaction, or\n(b) for protection,",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
{
"number": "12",
"title": "12. Measures (other than measuring instruments).",
"chapter": null,
"content": "(a) any transaction, or\n(b) protection,",
"footnote": "",
"is_definition": false,
"sort_order": 11
},
{
"number": "13",
"title": "13. Weighing and measuring instruments.",
"chapter": null,
"content": "(a) in any transaction, or\n(b) for protection,\n(a) in any transaction, or\n(b) for protection,",
"footnote": "",
"is_definition": false,
"sort_order": 12
},
{
"number": "14",
"title": "14. Procedure for carrying out calibration of vehicle tanks, etc.",
"chapter": null,
"content": "Chapter V\nImport of Weights and Measures",
"footnote": "",
"is_definition": false,
"sort_order": 13
},
{
"number": "15",
"title": "15. Registration of Importer.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
{
"number": "16",
"title": "16. Conditions, etc. for manufacture of a weight or measure exclusively for export.",
"chapter": null,
"content": "(a) his name and full address;\n(b) location of the factory in which such weight or measure is proposed to be manufactured;\n(c) description of weight or measure proposed to be manufactured;\n(d) documentary or other evidence indicating the existence of a firm contract for the export aforesaid or where there is no such firm contract for export, documentary or other evidence indicating that there is likely to be a demand for the export of non-standard weight or measure.",
"footnote": "",
"is_definition": false,
"sort_order": 15
},
{
"number": "17",
"title": "17. Prohibition on sale of non-standard weight or measure within the country.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 16
},
{
"number": "18",
"title": "18. Maintenance of record in relation to non-standard weight or measure.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 17
},
{
"number": "19",
"title": "19. Sample checking of weight and measure.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 18
},
{
"number": "20",
"title": "20. Checking of non-standard weights and measures sample which are to be exported.",
"chapter": null,
"content": "(i) if it is similar to any standard weight or measure, equal to the fee leviable for the verification and stamping of such standard weight or measure; and\n(ii) where such non-standard weight or measure is not similar to any standard weight or measure, the Central Government may specify such amount as fees as is commensurate with the labour involved in checking the non-standard weight or measure.\nChapter VI\nNon-Standard Weight or Measure to be Used for Scientific Investigation or Research",
"footnote": "",
"is_definition": false,
"sort_order": 19
},
{
"number": "21",
"title": "21. Permission to get manufactured non-standard weight or measure for scientific investigation or research.",
"chapter": null,
"content": "Chapter VII\nMiscellaneous",
"footnote": "",
"is_definition": false,
"sort_order": 20
},
{
"number": "22",
"title": "22. The manner of disposal of goods seized under this Act/rule.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 21
},
{
"number": "23",
"title": "23. Time within which unverified weight and measure to be verified and stamped.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 22
},
{
"number": "17",
"title": "24. Register and reports to be maintained by persons referred to in Section 17 or the Act.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 23
},
{
"number": "25",
"title": "25. Scale of fee.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 24
},
{
"number": "26",
"title": "26. Use of regional languages.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 25
},
{
"number": "27",
"title": "27. Periodical verification of weights or measures.",
"chapter": null,
"content": "(a) twenty four months for all weights, capacity measures, length measures, tape, beam scale and counter machine,\n(b) sixty months for storage tanks, and\n(c) twelve months for all weight or measure including tank lorry other than that mentioned in clauses (a) & (b).",
"footnote": "",
"is_definition": false,
"sort_order": 26
},
{
"number": "28",
"title": "28. Qualifications of Legal Metrology Officer.",
"chapter": null,
"content": "(a) is a graduate of a recognized university in Science (with physics as one of the subjects), technology or engineering or holds a recognized diploma in engineering with three years professional experience; and\n(b) is able to speak, read and write the regional language of the State.",
"footnote": "",
"is_definition": false,
"sort_order": 27
},
{
"number": "29",
"title": "29. Nomination of Director by a Company under the Act.",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 28
},
{
"number": "30",
"title": "30. Repeal and savings.",
"chapter": null,
"content": "(a) the previous operations of the said rules or anything done or omitted to be done or suffered therein; or\n(b) any right, privilege, obligation or liability acquired, accrued or incurred under the said rules; or\n(c) any penalty, forfeiture or punishment incurred in respect of any offence committed against the said rules; or\n(d) any investigation, legal, proceedings or remedy in respect of any such right, privilege, obligation, liability, penalty, forfeiture or punishment as aforesaid.\nIndex of Schedule of the Legal Metrology (General) Rules, 2011\nIndex of Schedule of the Legal Metrology (General) Rules, 2011\nFirst Schedule\nPART I\nReference Standard Weights\nPART II\nReference Standard Metre Bar\nSecond Schedule\nPART I\nSecondary Standard Weights\nPART II\nSecondary Standard Metre Bar\nPART III\nSecondary Standard Capacity Measures\nThird Schedule\nPART I\nWorking Standard Weights\nPART II\nWorking Standard Metre Bar\nPART III\nWorking Standard Capacity Measures\nFourth Schedule\nPART I\nReference Standard Balances\nPART I\nSecondary Standard Balances\nPART III\nWorking Standard Balances\nFifth Schedule\nPART I\nWeights (Other than Carat Weights)\nPART II\nCarat Weights\nPART III\nStandard Weights for testing of High Capacity Weighing\n\t\t\t\tMachine\nSixth Schedule\nPART I\nLiquid Capacity Measures\nPART II\nDispensing Measures\nPART III\nLiquor Measures\nPART IV\nLength Measures (Non-Flexible)\nPART V\nFolding Scales\nPART VI\nFabric or Plastic Tape Measures\nPART VII\nSteel Tape Measures\nPART VIII\nSurveying Chains\nPART IX\nTapes for Use in Measurement of Oil Quantities\nSeventh Schedule - Heading A\nSpecifications for Non-Automatic Weighing Instruments\nSpecifications for Non-Automatic Weighing Instruments\nSeventh Schedule - Heading B\nPART I\nBeam scales\nPART II\nCounter Machines\nSeventh Schedule - Heading C\nAutomatic Rail Weighbridge\nAutomatic Rail Weighbridge\nSeventh Schedule - Heading D\nAutomatic Gravimetric Filling Instruments\nAutomatic Gravimetric Filling Instruments\nSeventh Schedule - Heading E\nDiscontinuous Totalizing Automatic Weighing Instrument (Totalizing Hopper Weighers)\nDiscontinuous Totalizing Automatic Weighing Instrument (Totalizing Hopper Weighers)\nSeventh Schedule - Heading F\nAutomatic instruments for weighing road vehicles in motion and measuring axle loads\nAutomatic instruments for weighing road vehicles in motion and measuring axle loads\nEighth Schedule\nSpecifications for Measuring Instruments\nSpecifications for Measuring Instruments\nPART I\nVolumetric Container Filling Machines\nPART II\nBulk Meters\nPART III\nWater Meters\nPART IV\nMeasuring Systems for Liquids Other than Water\nPART V\nVolumetric Container Type Liquid Measuring Device\nPART VI\nClinical Thermometer\nPART VII\nManometers of Instruments for Measuring Arterial Blood\n\t\t\t\tPressure (Sphygmomanometers)\nPART VIII\nTaximeter\nPART IX\nCompressed gaseous fuel (CNG) measuring systems for vehicles\nNinth Schedule\nProcedure for Carrying Out Calibration of Vehicle Tanks etc.\nProcedure for Carrying Out Calibration of Vehicle Tanks etc.\nPART I\nCalibration of Vehicle Tanks for Petroleum Products and other\n\t\t\t\tLiquids\nPART II\nMethod for Calibration of Vertical Oil Storage Tanks\nPART III\nMethod for Computation of Capacity Tables for Vertical Oil\n\t\t\t\tStorage Tanks.\nTenth Schedule\nApplication Form for Registration of Importer of Weights and Measures\nApplication Form for Registration of Importer of Weights and Measures\nEleventh Schedule\nRegister to be Maintained by the Manufacturers/dealers/repairers of Weights and Measures\nRegister to be Maintained by the Manufacturers/dealers/repairers of Weights and Measures\nTwelfth Schedule\nScale of Fee\nScale of Fee\nThirteenth Schedule\nFormat for nomination of the Director by the Company\nFormat for nomination of the Director by the Company\nFirst Schedule\nDenomination, Materials, Shape and Permissible Errors, in Respect of Reference Standards\nDenomination, Materials, Shape and Permissible Errors, in Respect of Reference Standards\n[See Rule 3]\n[See Rule 3]\nPart I Reference Standard Weights",
"footnote": "",
"is_definition": false,
"sort_order": 29
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "Kilogram series\nGram series\nMilligram series\n(1)\n(2)\n(3)\n5\n500\n500\n2\n200\n200\n2\n200\n200\n1\n100\n100\n50\n50\n20\n20\n20\n20\n10\n10\n5\n5\n2\n2\n2\n2\n1\n1",
"footnote": "",
"is_definition": false,
"sort_order": 30
},
{
"number": "2",
"title": "2. Materials",
"chapter": null,
"content": "(a) Weights of 5kg to 1g shall be made from Admiralty bronze (88 Cu, 10 Sn, 2 Zn), nickel chromium alloy (8O Ni, 20 Cr) or austentic stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).\n(b) Weights of 500mg to 10mg shall be made from wire of either pure platinum, nickel chromium alloy (8O Ni, 20 Cr) or austenitic stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).\n(c) Weights of 5mg to 1mg shall be made of aluminium wire. Copper, silicon and zinc contained as impurities in aluminium shall not exceed 0.3 per cent in the aggregate.\nNote : The material used for all the weights shall be non-magnetic and it shall be ensured that the finished weights are also practically non-magnetic.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 31
},
{
"number": "3",
"title": "3. Shape and finish",
"chapter": null,
"content": "(a) For kilogram and gram series -\n(b) For milligram series -\n(c) The denominations shall be marked only on kilogram and gram series weights.\n(d) The entire surface of the weights, including their base and corners shall be free from any roughness and the surface of the weights when inspected visually shall not show any porosity and shall have a mirror finish.",
"footnote": "",
"is_definition": false,
"sort_order": 32
},
{
"number": "4",
"title": "4. Maximum permissible errors",
"chapter": null,
"content": "Denomination\nPermissible error ± mg\n(1)\n(2)\n5 kg\n7.5\n2 kg\n3.0\n1 kg\n1.5\n500 g\n0.75\n200 g\n0.30\n100 g\n0.15\n50 g\n0.10\n20 g\n0.080\n10 g\n0.060\n5 g\n0.050\n2 g\n0.040\n1 g\n0.030\n500 mg\n0.025\n200 mg\n0.020\n100 mg\n0.015\n50 mg\n0.012\n20 mg\n0.010\n10 mg\n0.008\n5 mg\n0.006\n2 mg\n0.006\n1 mg\n0.006",
"footnote": "",
"is_definition": false,
"sort_order": 33
},
{
"number": "5",
"title": "5. Protective and carrying case",
"chapter": null,
"content": "(a) These weights shall be stored in their boxes made from teakwood or any other suitable non-corrosive material with proper housing lined with chemically neutral velvet, chamois leather or soft plastic material. Wood used in such boxes shall be reasonably free from resins and volatile materials. Glue shall not be used for fixing velvet or such other material. The weights shall be housed in such a manner so as to avoid their movement during transit.\n(b) Each milligram weight be provided with a separate housing. A covering glass or a sheet of any other transparent and non-reactive and non-corrosive material shall be provided so as to ensure that these weights are not dislocated during transit.\n(c) A suitable device for lifting the kilogram and gram weights covered with chamois leather or other suitable material shall be provided. A pair of forceps capable of lifting easily milligram weights shall also be provided.",
"footnote": "",
"is_definition": false,
"sort_order": 34
},
{
"number": "6",
"title": "6. Inscription",
"chapter": null,
"content": "(a) The words 'Reference Standards Weights'\n(b) The identification number of such boxes,\n(c) The name of the manufacturer,\n(d) The material used for weights,\n(i) kilogram and gram series,\n(ii) milligram series,\n(e) The year of manufacture,\n(f) The verification mark of the NPL.\nPart II - Reference Standard Metre Bar",
"footnote": "",
"is_definition": false,
"sort_order": 35
},
{
"number": "1",
"title": "1. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 36
},
{
"number": "2",
"title": "2. Shape and dimensions",
"chapter": null,
"content": "(a) The metre bar shall be of H-section, approximately 25 mm x 25 mm (as per Figure 1)\n(b) The overall length of the metre bar shall be 1030 ± 1 mm and the graduated length shall be 1008 mm.\n(c) Ungraduated space of 11 mm shall be left after the last graduation mark.",
"footnote": "",
"is_definition": false,
"sort_order": 37
},
{
"number": "3",
"title": "3. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 38
},
{
"number": "4",
"title": "4. Graduations",
"chapter": null,
"content": "(a) The main scale shall be situated on the neutral plane and shall be graduated in millimetres throughout from to 1000 mm.\n(b) The main scale shall also have one additional mm mark before 0 and another after 1000 mm mark.\n(c) An additional fine scale shall also be provided at each end of the main scale for calibrating a micrometre microscope. This fine scale shall consist of ten 0.1 mm graduations (1 mm sub-divided into 10 parts) and shall be situated before the first graduation mark after leaving a blank space of 2 mm and also after the last mark with the same blank spacing.\n(d) The graduation marks shall be well-defined, of symmetrical section and have dean edges.\n(e) The width of graduation marks shall be between 8 and 10 micrometres. This width shall be constant to within ten percent over the length of each mark between the longitudinal setting lines.\n(f) The graduation marks shall not differ in width one from another by more than ± 10% of the average width of all the marks.\n(g) The graduation marks shall be parallel to one another to within one micrometre between the longitudinal setting lines.\n(h) The graduation marks shall be square to the scale axis to within ten minutes of arc.\n(i) The length of graduation marks shall be as follows :-\n2 mm for half em marks.\n1 mm for mm marks.\n(j) The lengths of the graduation marks on the two fine scales referred to in 4(c) shall be as follows :-\n3 mm for first and last mark.\n2 mm for 0.5 mm marks.\n1 mm for 0.1 mm marks.\n(k) The Bessel points shall be indicated by two vertical lines marked on either external side of the metre bar. The Bessel points shall be 571 mm apart, and shall be disposed equally on either side of the 50 mm mark.\n(l) No figures or numerals shall be marked on the surface of the main scale.\n(m) When supported at the marked Bessel points, the graduated surface shall be flat to within 0.05mm, i.e. all points on the surface shall be between two parallel planes 0.05 mm apart.",
"footnote": "",
"is_definition": false,
"sort_order": 39
},
{
"number": "5",
"title": "5. Auxiliary scale",
"chapter": null,
"content": "(a) An auxiliary scale shall be marked on one of the top edges of the metre bar.\n(b) The auxiliary scale shall consist of 1000 marks corresponding to the marks of the main scale.\n(c) The marks of the auxiliary scale shall be collinear (i.e., passing through the same vertical planes) with the graduation marks of the main scale to within ± 0.1 mm.\n(d) The width of graduation marks shall be not more than 100 micrometres and shall be clearly visible to the naked eyes having normal vision.\n(e) The length of the graduation marks shall be :\n2.5 mm for cm marks.\n2.0 mm for half cm marks.\n1.5 mm for mm marks.\n(f) The centimetre graduation marks shall be numbered in the increasing order of numeration.\n(g) The height of the numerals and the letters shall be approximately 3 mm.",
"footnote": "",
"is_definition": false,
"sort_order": 40
},
{
"number": "6",
"title": "6. Setting lines",
"chapter": null,
"content": "(a) A pair of longitudinal setting lines shall transverse the graduation marks and shall be parallel to the scale axis to within one minute of arc.\n(b) The two longitudinal lines shall be disposed symmetrically on either side of the centre of the graduation marks.\n(c) The separation of the longitudinal setting lines shall be 0.2 mm and their width shall be in between 8 and 10 micrometres.\n(d) Each longitudinal setting line shall be straight to within 30 micrometres.\n(e) The longitudinal setting lines shall be parallel to each other to within 50 micrometres.",
"footnote": "",
"is_definition": false,
"sort_order": 41
},
{
"number": "7",
"title": "7. Maximum permissible error",
"chapter": null,
"content": "(a) When the metre bar is supported on its marked Bessel points, the errors in length between any two graduation marks of the main scale at the temperature of 20°C, shall not exceed 0.010 mm.\n(b) In the case of the fine scales, the error between any two 0.1 mm marks shall not exceed 0.005 mm.",
"footnote": "",
"is_definition": false,
"sort_order": 42
},
{
"number": "8",
"title": "8. Inscription",
"chapter": null,
"content": "(a) the words \"Reference Standard Metre Bar\",\n(b) the identification number of the metre bar,\n(c) the verification mark of the NPL, after the first calibration and marks of subsequent verification to be made on the plate of the carrying case of the metre bar,\n(d) the name of the manufacturers,\n(e) the material of the metre bar,\n(f) the words, figures and letter \"Standard at 20°C\",\n(g) the year of manufacture.",
"footnote": "",
"is_definition": false,
"sort_order": 43
},
{
"number": "9",
"title": "9. Protective and carrying case",
"chapter": null,
"content": "(a) The standard metre bar shall be housed in a case made from suitable material and provided with a handle, lined internally with velvet, a plastic material or any other material and in such a way that the metre bar is not likely to be damaged, particularly by shocks or corrosion.\n(b) The case shall have affixed on it a plate bearing the inscription \"Reference Standard Metre Bar\" and the identification number.\nSecond Schedule\nDenominations, Materials, Shape and Permissible Errors\nDenominations, Materials, Shape and Permissible Errors\nIn Respect of Secondary Standards\nIn Respect of Secondary Standards\n[See Rule 4 ]\n[See Rule 4 ]\nPart I - Secondary Standard Weights",
"footnote": "",
"is_definition": false,
"sort_order": 44
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "Kilogram series\nGram series\nMilligram series\n(1)\n(2)\n(3)\n10\n500\n500\n5\n200\n200\n2\n200\n200\n2\n100\n100\n1\n50\n50\n20\n20\n20\n20\n10\n10\n5\n5\n2\n2\n2\n2\n1\n1",
"footnote": "",
"is_definition": false,
"sort_order": 45
},
{
"number": "2",
"title": "2. Materials",
"chapter": null,
"content": "(a) Weights of 10 kg to 1 g shall be made from admirably bronze (88 Cu, 10 Sn, 2 Zn), nickel chromium alloy (80 Ni, 20 Cr) or austenitic stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).\n(b) Weights of 500 mg to 10 mg shall be made from wire of either pure platinum, nickel chromium alloy (80 Ni, 20 Cr) or austenitic stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).\n(c) Weights of 5 mg to 1 mg shall be made of aluminium wire. Copper, silicon and zinc contained as impurities in aluminium shall not exceed 0.3 per cent in the aggregate.",
"footnote": "",
"is_definition": false,
"sort_order": 46
},
{
"number": "3",
"title": "3. Shape and finish",
"chapter": null,
"content": "(a) For kilogram and gram series - Integral cylindrical body with knob rounded at top. Weight of 10 kilogram to 100 gram (both inclusive) shall have adjusting devices.\n(b) For milligram series - the weights shall be in the form of square sheets, one of the corners being bent at a right angle.\n(c) The denominations shall be marked only on kilogram and gram series weights.\n(d) The entire surface of the weights, including their base and corners shall be free from any roughness and the surface of the weights when inspected visually shall not show any porosity and shall have a mirror polish appearance.",
"footnote": "",
"is_definition": false,
"sort_order": 47
},
{
"number": "4",
"title": "4. Maximum permissible error",
"chapter": null,
"content": "Denomination\nPermissible error ± mg\n(1)\n(2)\n10 kg\n50\n5kg\n25\n2kg\n10\n1kg\n5\n500 g\n2.5\n200 g\n1.05\n100g\n0.5\n50g\n0.30\n20 g\n0.25\n10 g\n0.2\n5 g\n0.15\n2 g\n0.12\n1 g\n0.1\n500 mg\n0.08\n200 mg\n0.06\n100 mg\n0.05\n50 mg\n0.04\n20 mg\n0.03\n10 mg\n0.02\n5 mg\n0.02\n2 mg\n0.02\n1 mg\n0.02",
"footnote": "",
"is_definition": false,
"sort_order": 48
},
{
"number": "5",
"title": "5. Protective and carrying case",
"chapter": null,
"content": "(a) These weights shall be stored in their boxes made from teakwood or any other suitable non-corrosive material with proper housing lined with chemically neutral velvet, chamois leather or soft plastic material. Wood used in such boxes shall be reasonably free from resins and volatile materials, Glue shall not be used for fixing velvet or such other material. The weights shall be housed in such a manner so as to avoid their movement during transit.\n(b) Each milligram weight shall be provided with a separate housing. A covering glass or a sheet of any other transparent, non-reactive and non-corrosive material shall be provided so as to ensure that these weights are not dislocated during transit.\n(c) A suitable device for lifting the kilogram and gram weights, covered with chamois leather or other suitable material, shall be provided. A pair of forceps capable of lifting easily milligram weights shall also be provided.",
"footnote": "",
"is_definition": false,
"sort_order": 49
},
{
"number": "6",
"title": "6. Inscription",
"chapter": null,
"content": "(a) the words 'Secondary Standard Weights';\n(b) the identification number of the secondary standard weights,\n(c) the name of the manufacture,\n(d) the material used for weights,\n(i) kilogram & gram series\n(ii) milligram series,\n(e) the year of manufacture,\n(f) the mark of verification.\nPart II - Secondary Standard Metre Bar",
"footnote": "",
"is_definition": false,
"sort_order": 50
},
{
"number": "1",
"title": "1. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 51
},
{
"number": "2",
"title": "2. Shape and dimensions",
"chapter": null,
"content": "(a) The metre bar shall have a rectangular cross section with dimensions 30 mm x 15 mm approximately.\n(b) The top surface shall have two rectangular grooves along its length (as per Figure 2).\n(c) The overall length of the measure shall be 1030 ± 1 mm and the graduated length shall be 1010 mm.\n(d) Ungraduated space of 10 mm shall be left after the last graduation mark.",
"footnote": "",
"is_definition": false,
"sort_order": 52
},
{
"number": "3",
"title": "3. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 53
},
{
"number": "4",
"title": "4. Graduations",
"chapter": null,
"content": "(a) The metre bar shall be graduated in millimetres throughout from 0 to 1000 mm.\n(b) A length of 10 mm before the zero graduation mark shall also be graduated in millimetres.\n(c) The scale shall be regular. The width of the graduation marks shall be between thirty and fifty micrometres.\n(d) The width of the graduation marks shall be uniform to within ± ten per cent of the average width of all the marks.\n(e) Each graduation marks shall be straight to within ten micrometres over its length.\n(f) The graduation marks shall be parallel to one another to within ten micrometres.\n(g) The graduation marks shall be square to the scale axis to within twenty minutes of arc.\n(h) The graduation marks representing centimetres shall be longer than those representing half centimetres and the graduation marks representing half centimetres shall be longer than those representing millimetres.\n(i) The length of the graduation marks shall be not less than:\n2 mm for mm marks.\n3 mm for half cm marks.\n4 mm for cm marks.\n(j) There shall be two short longitudinal setting lines each of 5 mm in length which shall be drawn leaving a blank space of 2 mm, the one before the first and the other after the last graduation mark. The longitudinal lines shall be on a straight line which represent the imaginary central line and the departure from the central line shall be not more than 0.1 mm.\n(k) When supported on the Bessel points or on a flat surface the graduated surface shall be flat to within 0.05 mm, i.e. all the points on the surface shall be between two parallel planes 0.05 mm apart.",
"footnote": "",
"is_definition": false,
"sort_order": 54
},
{
"number": "5",
"title": "5. Auxiliary scale",
"chapter": null,
"content": "(a) Auxiliary scale shall be marked on one of the top edges of the metre bar.\n(b) The auxiliary scale shall consist of centimetre and half centimetre marks corresponding to the marks of the main scale.\n(c) The marks of the auxiliary scale shall be collinear (passing through the same vertical planes) with the graduations of main scale to within ± 0.1 mm.\n(d) The width of the graduation marks shall be not more than one hundred micrometres.\n(e) The graduation marks representing centimetres shall be longer than those representing half centimetres.\n(f) The length of the graduation marks shall be not less than:\n3 mm for cm marks, and\n2 mm for half cm marks.\n(g) The centimetre graduation marks shall be numbered in the increasing order of numeration.\n(h) The height of the numerals and the letters shall be approximately 3 mm.",
"footnote": "",
"is_definition": false,
"sort_order": 55
},
{
"number": "6",
"title": "6. Maximum permissible error",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 56
},
{
"number": "7",
"title": "7. Inscription",
"chapter": null,
"content": "(a) the words \"Secondary Standard Metre Bar\",\n(b) an identification number of the secondary standard metre bar,\n(c) the name of the manufacturer,\n(d) the name of the manufacturer,\n(e) the material of the metre bar,\n(f) the words, figures and letter \"Standard at 20°C\"\n(g) the year of manufacture,\n(h) the mark of verification on the plate of the carrying case of the metre bar.",
"footnote": "",
"is_definition": false,
"sort_order": 57
},
{
"number": "8",
"title": "8. Protective find carrying case",
"chapter": null,
"content": "(a) The metre bar shall be housed in a case made from suitable material and provided with a handle, lined internally with velvet, a plastic material or any other material, and in such a way that the measure is not likely to be damaged, particularly by shocks or corrosion.\n(b) The case shall have affixed on it a plate bearing the Inscription \"Secondary Standard Metre Bar\" and the identification number.\nNote : The existing secondary standard metre bars may differ in minor details in regard to setting lines and inscriptions, etc.\nNote :\nPart III - Secondary Standard Capacity Measures",
"footnote": "",
"is_definition": false,
"sort_order": 58
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "Litre series (1)\nMillilitre series (ml)\n5\n500\n2\n200\n1\n100\n50\n20\nNote: 1 litre = 1 dm 3 = 0.001 m 3 ; 1 ml = 1 cm 3\nNote:",
"footnote": "",
"is_definition": false,
"sort_order": 59
},
{
"number": "2",
"title": "2. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 60
},
{
"number": "3",
"title": "3. Shape",
"chapter": null,
"content": "(a) The secondary standard capacity measure of five litre shall be cylindrical and have its inside diameter equal to the height of the measure. This shall have two handles attached securely to its sides.\n(b) The measure of 2 l and below shall be of the same shape as above but shall not have any handles.\n(c) The denominations of the secondary standard capacity measures shall be engraved on the outside surface.\n(d) Each secondary standard capacity measure shall be provided with a specially selected striking glass on the measures and glasses shall be securely packed in velvet lined teakwood boxes.",
"footnote": "",
"is_definition": false,
"sort_order": 61
},
{
"number": "4",
"title": "4. Maximum permissible error",
"chapter": null,
"content": "Denomination\nPermissible error ± ml\n5 l\n2\n2 l\n1\n1 l\n0.8\n500 ml\n0.5\n200 ml\n0.4\n100 ml\n0.3\n50 ml\n0.2\n20 ml\n0.1",
"footnote": "",
"is_definition": false,
"sort_order": 62
},
{
"number": "5",
"title": "5. Protective and carrying cases",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 63
},
{
"number": "6",
"title": "6. Inscriptions",
"chapter": null,
"content": "(a) the inscription Secondary Standard Capacity Measures;\n(b) the identification number of secondary standard capacity measures;\n(c) the name of the manufacturer;\n(d) the year of manufacture;\n(e) the mark of verification of proper verification authority.\nThird Schedule\nDenominations, Material, Shape and Permissible Errors in Respect of Working Standards\nDenominations, Material, Shape and Permissible Errors in Respect of Working Standards\n[See Rule 5]\n[See Rule 5]\nPart I - Working Standard Weights",
"footnote": "",
"is_definition": false,
"sort_order": 64
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "Kilogram series\nGram series\nMilligram series\n(1)\n(2)\n(3)\n20\n500\n500\n10\n200\n200\n10\n200\n200\n5\n100\n100\n2\n50\n50\n2\n20\n20\n1\n10\n10\n5\n5\n2\n2\n2\n2\n1\n1",
"footnote": "",
"is_definition": false,
"sort_order": 65
},
{
"number": "2",
"title": "2. Material",
"chapter": null,
"content": "(a) Weights of 20 kg to 1 g shall be cast from admiralty bronze (88 Cu, 10 Sn, 2 Zn) or made from cupro-nickel (75 Cu, 25 Ni) or nickel chromium alloy (80 Ni, 20 Cr) or austenitic stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).\n(b) Weights of 500 mg to 100 mg shall be made from admiralty bronze (rolled) (88 Cu, 10 Zn, 2 Sn) sheets or from the sheets of nickel chromium alloy (80 Ni 20 Cr) or austenitic stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).\n(c) Weights of 50 mg to 1 mg shall be made of aluminium sheets. Copper, silicon and iron contained as impurities in the aluminium shall not exceed 0.3 per cent in the aggregate.",
"footnote": "",
"is_definition": false,
"sort_order": 66
},
{
"number": "3",
"title": "3. Shape and finish",
"chapter": null,
"content": "(a) Weights of 20 kg and 10 kg shall be cylindrical in shape and shall be cast in two parts, the top part being screwed snugly into the bottom part. The top part shall be cast in the form of a handle for lifting purposes. The two parts after assembly shall be locked by means of a set screw over which the seal of the verifying authority shall be affixed.\n(b) Weights of 5 kg to 200 gm (inclusive) shall be cast in two parts, the top part being screwed snugly into the bottom part. The top part shall be cast in the form of a knob for lifting purposes. The two parts, after assembly, shall be locked by means of a set screw, over which the seal of the verifying authority shall be affixed.\n(c) Weights of 100g to 10 g (inclusive) shall be as in (b) above except that there shall be no locking arrangement.\n(d) Weights of 5 g to 1 g (inclusive) shall be integral weights with knob.\n(e) Weights of 500 mg to 1 mg (inclusive) shall be of square shape with the one of the sides bent at right angles to the flat surface for ease of handling.\n(f) The denominations shall be marked on the weights.\n(g) The entire surface of the weights, including their base and corners shall be free from roughness.",
"footnote": "",
"is_definition": false,
"sort_order": 67
},
{
"number": "4",
"title": "4. Maximum permissible error",
"chapter": null,
"content": "Denomination\nPermissible error ± mg\n20 kg\n300\n10 kg\n150\n5 kg\n75\n2 kg\n30\n1 kg\n15\n500 g\n7.5\n200 g\n3.0\n100 g\n1.5\n50 g\n1.0\n20 g\n0.8\n10 g\n0.6\n5 g\n0.6\n2 g\n0.4\n1 g\n0.3\n500 mg\n0.25\n200 mg\n0.20\n100 mg\n0.15\n50 mg\n0.12\n20 mg\n0.10\n10 mg\n0.08\n5 mg\n0.06\n2 mg\n0.06\n1 mg\n0.06",
"footnote": "",
"is_definition": false,
"sort_order": 68
},
{
"number": "5",
"title": "5. Protective and carrying case",
"chapter": null,
"content": "(a) These weights shall be stored in their boxes made from teakwood or any other suitable non corrosive material with proper housing lined with chemically neutral velvet, chamois leather or soft plastic material. Wood used in such boxes shall be reasonably free from resins and volatile materials. Glue shall not be used for fixing velvet or such other material. The weights shall be housed in such a manner so as to avoid their movement during transit.\n(b) Each milligram weight shall be provided with a separate housing. A covering glass or a sheet of any other transparent, non-reactive and non-corrosive material shall be provided so as to ensure that these weights are not dislocated during transit.\n(c) A suitable device for lifting the kilogram and gram weights, covered with chamois leather or other suitable material, shall be provided. A pair of forceps capable of lifting easily milligram weights shall also be provided.",
"footnote": "",
"is_definition": false,
"sort_order": 69
},
{
"number": "6",
"title": "6. Inscription",
"chapter": null,
"content": "(a) the words 'Working Standard Weights';\n(b) the identification number of the working standard weights,\n(c) the name of the manufacturer,\n(d) the year of manufacture,\n(e) the marks of verification.\nPart II - Working Standard Metre Bar",
"footnote": "",
"is_definition": false,
"sort_order": 70
},
{
"number": "1",
"title": "1. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 71
},
{
"number": "2",
"title": "2. Shape and dimensions",
"chapter": null,
"content": "(a) The metre bar shall have a rectangular cross section of minimum dimensions 20 mm x 10 mm. The existing cross-section with dimensions 30 mm x 15 mm shall be preferred.\n(b) The overall length of the metre bar shall be 1030 ± 1 mm and the graduated length shall be 1010 mm.\n(c) Ungraduated length of 10 mm shall be left after the last graduated marks.",
"footnote": "",
"is_definition": false,
"sort_order": 72
},
{
"number": "3",
"title": "3. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 73
},
{
"number": "4",
"title": "4. Graduations",
"chapter": null,
"content": "(a) The metre bar shall be graduated in millimetre throughout from 0 to 1000 mm on the wider upper surface.\n(b) A length of 10 mm before the zero graduation mark shall also be graduated in millimetres.\n(c) The scale shall be regular. The thickness of the graduation marks shall be uniform and shall lie between 30 and 80 micrometres.\n(d) The width of the graduation marks shall be uniform to within ± fifteen per cent of the average width of all the marks.\n(e) The graduation marks representing centimetres shall be longer than those representing half centimetres and the graduation marks representing half centimetres shall be longer than those representing millimetres.\n(f) Each graduation mark shall be straight to within ten micrometres over its length.\n(g) The graduation marks shall be parallel to one at other to within ten micrometres.\n(h) The length of the graduation marks shall be not less than -\n3 mm for mm marks.\n5 mm for half cm marks.\n8 mm for cm marks.\n(i) The centimetres graduation marks shall be numbered in the Increasing order of numeration.\n(j) The height of the numerals and the letters (symbols) shall be approximately 3 mm.\n(k) The graduation marks shall be square to the scale axis to within 30 minutes of arc.",
"footnote": "",
"is_definition": false,
"sort_order": 74
},
{
"number": "5",
"title": "5. Cursor",
"chapter": null,
"content": "(a) The errors on the length measure under verification shall be determined by means of a scale marked on a plate, made from transparent material, which is carried by a cursor capable of moving along the length of the metre bar. The plate shall have appropriate and constant dimensions and thickness.\n(b) The scale on the plate shall :\n(i) either be a length of 9 mm divided into 10 parts thus forming a Vernier scale to read the errors to the nearest of 0.1 mm; or\n(ii) one millimetre divided into 10 parts for reading the errors directly to the nearest of 0.1 mm.\n(c) The thickness of the graduation marks on the scale shall be less than that of the graduation marks on the metre bar.\n(d) The graduation marks on the scale shall be inscribed on the surface facing the graduation marks on the metre bar.\n(e) The readings shall be taken by means of a magnifying glass, the magnification of which shall be not less than 5X if the scale is graduated in 0.1 mm and not less than 3X if the scale is of Vernier type.\n(f) The cursor shall be such that it would be possible to move it smoothly without jerks, along a straight line from one end of the measure to the other.\n(g) A mechanism to raise, lower and laterally move the measure under verification, within a view to putting its graduated surface at a proper level and aligning its zero mark with that of the metre bar shall be provided.\n(h) For facilitating the verification of end measures, two vertical stops bearing reference lines shall be provided. The first stop shall be such that its reference line can be aligned with the zero mark of the metre bar. The second stop shall be capable of moving along the entire length of the metre bar.",
"footnote": "",
"is_definition": false,
"sort_order": 75
},
{
"number": "6",
"title": "6. Maximum permissible errors",
"chapter": null,
"content": "(a) The error on the length between any two graduation marks on the working standard length measure, at the standard temperature of 20°C, shall not exceed the value \"e\" calculated according to the following formula :\ne = (50 + L/20) micrometres\n(b) The errors on the length between any two graduation lines on the plate shall not exceed ± 20 micrometres.",
"footnote": "",
"is_definition": false,
"sort_order": 76
},
{
"number": "7",
"title": "7. Inscription",
"chapter": null,
"content": "(a) the words \"Working Standard Metre Bar\",\n(b) identification number of the metre bar,\n(c) the name of the manufacturer,\n(d) the material of the metre bar,\n(e) the words, figures and letter \"Standard at 20°C\".\n(f) the year of manufacture.",
"footnote": "",
"is_definition": false,
"sort_order": 77
},
{
"number": "8",
"title": "8. Protective and carrying case",
"chapter": null,
"content": "(a) The standard metre bar shall be housed in a case made from suitable material and provided with a handle, lined internally with velvet, a plastic material or any other material and in such a way that the metre bar is not likely to be damaged, particularly by shocks or corrosion.\n(b) The case shall have affixed on it a plate bearing the inscription \"Working Metre Bar\" and the identification number.\nNote : The existing working standard length measure (metre bars) may differ in minor details in regard to inscriptions, etc. on it.\nNote :\nPart III - Working Standard Capacity Measures",
"footnote": "",
"is_definition": false,
"sort_order": 78
},
{
"number": "1",
"title": "1. Denomination",
"chapter": null,
"content": "Litre series (l)\nMillilitre series (ml)\n10\n500\n5\n200\n2\n100\n1\n50\n20",
"footnote": "",
"is_definition": false,
"sort_order": 79
},
{
"number": "2",
"title": "2. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 80
},
{
"number": "3",
"title": "3. Shape",
"chapter": null,
"content": "(a) Working standard capacity measure of 10 litres shall be cylindrical and have its inside diameter approximately equal to the height of the measure. This shall have two handles attached securely to its sides.\n(b) Working standard capacity measures of 5 litres and below shall be of the same shape as above but shall not have any handles.\n(c) The outside of the body of the working standard capacity measures shall be oxidized to give a smooth dull black surface and the inside shall be tinned.\n(d) The denominations of the working standard measures shall be engraved on the outside surface.\n(e) Each working standard capacity measure shall be provided with specially selected striking glass and the measures and glasses shall be securely packed in velvet lined teakwood boxes.",
"footnote": "",
"is_definition": false,
"sort_order": 81
},
{
"number": "4",
"title": "4. Maximum permissible error",
"chapter": null,
"content": "Denomination\nPermissible error in ml ± ml\n10 litres\n8\n5 litres\n4\n2 litres\n2\n1 litre\n1.5\n500 ml\n1.0\n200 ml\n0.8\n100 ml\n0.6\n50 ml\n0.4\n20 ml\n0.2",
"footnote": "",
"is_definition": false,
"sort_order": 82
},
{
"number": "5",
"title": "5. Pipette measures",
"chapter": null,
"content": "(a) One mark pipettes of capacities 10 ml and 5 ml.\n(b) Graduated pipettes of capacities 5 ml graduated at every tenth of ml.",
"footnote": "",
"is_definition": false,
"sort_order": 83
},
{
"number": "6",
"title": "6. Delivery time and maximum permissible errors of pipette measures",
"chapter": null,
"content": "Denomination ml\nDelivery time in\n\t\t\t\t\tseconds __________________\nPermissible error ( + ml)\nMinimum\nMaximum\n10\n15\n25\n0.04\n5\n10\n20\n0.03\n5\n10\n40\n0.05\n(Graduated)",
"footnote": "",
"is_definition": false,
"sort_order": 84
},
{
"number": "7",
"title": "7. Protective and carrying cases",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 85
},
{
"number": "8",
"title": "8. Inscriptions",
"chapter": null,
"content": "(a) the words \"Working Standard Capacity Measures\",\n(b) the identification number of the capacity measures,\n(c) the name of the manufacturer,\n(d) the year of manufacture,\n(e) the mark(s) of verification of proper verification authority.\nFourth Schedule\nSpecifications for Standard Equipment\nSpecifications for Standard Equipment\n[See Rules 7, 8 and 9]\n[See Rules 7, 8 and 9]\nPart I - Reference Standard Balances\nPart II - Secondary Standard Balances\nCapacity\nSensitivity figure Mg/div.\nMin.scale division\nMaximum variation in sensitivity figure with\n\t\t\t\t\trespect to load\nMinimum overall accuracy of measurement\n1\n2\n3\n4\n5\n20kg\n25\n1.5mm\n10per cent\n25mg in 10 kg\n5 kg\n7.5\n1.0 mm\n10 per cent\n7.5 mg in 2 kg\n1kg\n1.5\n1.0mm\n10 percent\n1.5 mg in 500 g\n200g\n0.5\n1.0mm\n10 per cent\n0.5 mg in 50 g\n20g\n0.1\n1.0 mm\n10 per cent\n0.01 mg in 1 mg\n2g\n0.02\n0.75 mm\n10 percent\n0.02 mg in 1 mg\nCapacity\nMaximum value of verification scale interval\nType of weights to be verified\n20 kg\n1 mg\n20 kg to 500g\n200 g\n0.01 mg\n200 g to 1 mg\nPart III - Working Standard Balances\n(a) Equi-arm types balances;\n(b) Digital type balances.\nCapacity\nMax. Sensitivity figure/division\nMaximum variation in sensitivity figure\nMinimum overall accuracy of measurement\n50 kg\n100 mg\n20 per cent\n100 mg in 10 kg\n5 kg\n10 mg\n20 per cent\n10 mg in 500 g\n200 g\n1 mg\n20 per cent\n1 mg in 100 g\n50 g\n0.4 mg\n20 per cent\n0.4 mg in 5 g\n2 g\n0.05 mg\n20 per cent\n0.05 mg in 1 mg\n2.1 The standard deviation of ten consecutive rest points for every working standard balance shall not be more than one scale division.\n2.2 The deviation in arm ratio from unity, for every working standard equi-arm balance shall not be more than the fraction equal to sensitivity figure divided by the full load (both being taken in the same unit).\nCapacity\nMax. value of verification scale interval\nType of weight to be verified\n50kg\n1g\nNon-bullion: 50 kg and 20 kg\n20kg\n0.1g\nBullion:10kg, 5kg;\nNon-bullion:20kg to 2 kg\n2kg\n10mg\nBullion:2kg to 500g;\nNon-bullion : 2kg to 200g\n200g\n10mg\nBullion : 200g and below;\nNon-bullion : 200g and below\nNote : For verification of bullion or carat weights, only indoor type working standard balances shall be used.\nNote :\nFifth Schedule\n[See Rule 11]\n[See Rule 11]\nPart - I\nWeights (Other than Carat Weights)\nWeights (Other than Carat Weights)\nGeneral\n(A) Iron weights, parallelopiped (50 kg to 5 kg)\n(B) Cylindrical knob type weights (10 kg to 19)\n(C) Iron weights, hexagonal (50 kg to 50 g)\n(D) Bullion weights (10 kg to 1 g) and\n(E) Sheet metal weights (500 mg to 1 mg)\nA. - Iron Weights Parallelepiped (50 kg to 5 kg)",
"footnote": "",
"is_definition": false,
"sort_order": 86
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 87
},
{
"number": "2",
"title": "2. Shape",
"chapter": null,
"content": "(a) The weights shall be integral and in the form of parallelepiped rectangles with corners rounded off and having a rigid handle for ease of handling.\n(b) The shapes shall be as shown either in Figure 3 or in Figure 4.",
"footnote": "",
"is_definition": false,
"sort_order": 88
},
{
"number": "3",
"title": "3. Material",
"chapter": null,
"content": "(a) Body: The body shall be made or manufactured from grey cast Iron.\n(b) Handles: Handles shall be made or manufactured from the following materials:\n(i) Type 1 weights - Steel tube without soldering\n(ii) Type 2 weights - Cast along with the body\n(c) Method of manufacture:",
"footnote": "",
"is_definition": false,
"sort_order": 89
},
{
"number": "4",
"title": "4. Loading holes",
"chapter": null,
"content": "(a) The weights shall be provided with loading holes of either Type 1 or Type 2 indicated below:\nType 1 loading hole\n(i) The loading hole shall be located within the tube which forms the handle (See Figure 3).\n(ii) The loading hole shall be closed either with a screwed brass plug or a brass disc. The screwed brass plug shall be provided with a screw driver slot and the brass disc shall have a central hole to facilitate lifting.\n(iii) The plug or a disc shall be sealed by means of a lead pellet pressed firmly into an internal circular slot or in the threaded part of the tube.\nType 2 loading hole\n(i) The loading hole shall be cast in one of the upper surfaces of the weights and shall open out on the upper surface (See Figure 4).\n(ii) This loading hole shall be closed by a plate cut from mild steel.\n(iii) The mild steel plate shall be closed by a lead pellet pressed firmly into the conical hole.\n(b) In case of new weights, about two-third of the depth of the loading hole shall remain empty after adjustment.",
"footnote": "",
"is_definition": false,
"sort_order": 90
},
{
"number": "5",
"title": "5. Markings",
"chapter": null,
"content": "(a) The denomination of the weight and the marker's or manufacturer's name or trade mark shall be indicated indelibly in the sunken form or in relief, on the upper surface of the central portion of the weight. (See Figure 3 and Figure 4.)\n(b) The denomination of the weight shall be indicated in the international form of Indian numerals in an indelible manner with the symbols as illustrated below:\nNote : The abbreviation fdyks or fdxzk , may be indicated in the regional script.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 91
},
{
"number": "6",
"title": "6. Dimensions",
"chapter": null,
"content": "(a) The dimensions of the two types of weight shall be as specified in Tables 1 and 2.\n(b) The tolerances on dimensions shall be ± 5 per cent.\nTable 1\nTable 1\nParallelepiped Weights Dimensions for Type 1 Weights\n(In millimetres)\nDenomination\nA\nA'\nB\nB'\nH\nC\nD\nE\nF\nG/G'\n5kg\n150\n152\n75\n77\n84\n36\n30\n6\n66\n12/20\n10kg\n190\n193\n95\n97\n109\n46\n38\n8\n84\n12/20\n20kg\n230\n234\n115\n117\n139\n61\n52\n12\n109\n24/32\n50kg\n310\n314\n155\n157\n192\n83\n74\n16\n152\n24/32\nDenomination\nI\nJ\nK\nT\nL\nN\nO\nU\nV\nW\nP\n5kg\n145\n5\n12\nM16 x 1.5\n14\n1\n2\n16.5\n18\n16\n5\n10kg\n185\n6\n16\nM16 x 1.5\n14\n1\n2\n16.5\n18\n16\n5\n20kg\n220\n8\n20\nM27 x 1.5\n21\n2\n3\n27.5\n30\n27\n8\n50kg\n300\n10\n25\nM27 x 1.5\n21\n2\n3\n27.5\n30\n27\n8\nTable 2\nTable 2\nParallelepiped Weights Dimensions for type 2 Weights.\n(In millimetres)\nDenomination\nA\nA'\nB\nB'\nH\nC\nD\nE\nF\nG\nJ\nK\nM\nN\nP\n5kg\n150\n152\n75\n77\n84\n36\n30\n6\n66\n19\n5\n12\n16\n13\n55\n10kg\n190\n193\n95\n97\n109\n46\n38\n8\n84\n25\n6\n16\n35\n25\n70\n20kg\n230\n234\n115\n117\n139\n61\n52\n12\n109\n29\n8\n20\n50\n30\n95\n50kg\n310\n314\n155\n157\n192\n83\n74\n16\n152\n40\n10\n25\n70\n40\n148",
"footnote": "",
"is_definition": false,
"sort_order": 92
},
{
"number": "7",
"title": "7. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 93
},
{
"number": "8",
"title": "8. Permissible error",
"chapter": null,
"content": "Denomination\nPermissible error _________________________\nVerification(mg)\nInspection(mg)\n50kg\n7500\n± 7500\n20kg\n3000\n± 3000\n10kg\n1500\n± 1500\n5kg\n750\n± 750",
"footnote": "",
"is_definition": false,
"sort_order": 94
},
{
"number": "9",
"title": "9. Stamping",
"chapter": null,
"content": "B. - Cylindrical Knob Type Weights (10 Kg to 1 g)",
"footnote": "",
"is_definition": false,
"sort_order": 95
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 96
},
{
"number": "2",
"title": "2. Shape",
"chapter": null,
"content": "(a) The weights shall be integral and cylindrical in shape and provided with a flattened knob for ease of handling.\n(b) The shapes shall be as shown in Figure (5),",
"footnote": "",
"is_definition": false,
"sort_order": 97
},
{
"number": "3",
"title": "3. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 98
},
{
"number": "4",
"title": "4. Method of manufacture",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 99
},
{
"number": "5",
"title": "5. Loading hole",
"chapter": null,
"content": "(a) Weights of denominations 10g to 1g both inclusive, shall be solid, integral weights without a loading hole.\n(b) Weights of denominations 10kg to 20g both inclusive, shall be provided with a loading hole.\n(c) The loading hole shall be cylindrical and shall pass through the axis of the weight open out on the upper surface of the knob and have wider diameter at its upper end as shown in Figure 5.\n(d) The loading hole shall be closed either by means of a threaded brass plug or a flat brass disc. (See Figure 5).\nNote : The thread used shall be that commonly known as 'ISO Metric'.\nNote :\n(i) The threaded plug shall have a slot for adjusting it by means of a screw driver.\n(ii) The flat disc shall be provided with a suitable hole in the centre to facilitate handling.\n(e) The plug or the flat disc shall be closed by means a lead pellet pressed firmly into the circular groove in the wider part of the loading hole.\n(f) Weights without a loading hole shall be adjusted by machining or grinding,\n(g) Weights with loading hole shall be adjusted with heavy metallic materials such as lead shots.\n(h) In the case of new weights about two-thirds of the depth of the loading hole shall remain empty after adjustment.",
"footnote": "",
"is_definition": false,
"sort_order": 100
},
{
"number": "6",
"title": "6. Marking",
"chapter": null,
"content": "(a) The denomination of the weight and the maker's or manufacturer's name or trade mark shall be indicated indelibly, in the sunken form or in relief, on the flat knob. (See Figure 5).\n(b) The denomination of weights of 10 kilograms to 500 grams may also be indicated on the cylindrical body of the weight, provided that the numerals and letters of the symbol shall be larger than those used for indicating them on the knob.\n(c) The denomination of the weight shall be indicated in the international form of Indian numerals in an indelible manner with the symbols as illustrated below:\nNote : The abbreviation fdyks] fdxzk] xzk or xzke may be indicated in the regional script.\nNote :\nfdyks] fdxzk] xzk",
"footnote": "",
"is_definition": false,
"sort_order": 101
},
{
"number": "7",
"title": "7. Dimensions",
"chapter": null,
"content": "(a) The dimensions of cylindrical weights shall be as specified in Tables 3 and 4.\n(b) The tolerances on dimensions shall be :\n(i) for weights 1kg and below ± 10 per cent;\n(ii) for weights above 1kg ± 5 per cent.\nTable 3\nTable 3\nCylindrical Knob Type Weights-Dimension for Weights in mm.\nDenomination\nU\nV\nW\nH\nY\nR\nJ\nK\n10kg\n5kg\n2kg\n1kg\n500g\n200g\n100g\n50g\n20g\n10g\n5\n2g\n1g\n100\n80\n60\n48\n38\n28\n22\n18\n13\n10\n8\n6\n6\n90\n72\n54\n43\n34\n25\n20\n16\n11.5\n9\n7\n5.5\n5.5\n58\n46\n36\n27\n22\n16\n13\n10\n7.5\n6\n4.5\n3\n3\nAccording to material\n17\n13\n10\n8\n6\n4.5\n4\n3\n2\n1.6\n1.4\n1\n1\n15\n12\n9\n7\n5.5\n4\n3.5\n2.5\n1.8\n1.5\n1.25\n0.9\n0.9\n3\n2\n2\n2\n1.5\n1.5\n1\n1\n0.5\n0.5\n0.5\n0.5\n0.5\n10\n10\n5\n5\n3.2\n3.2\n2\n2\n1.5\n1\n1\n1\n1\nWithout\nloading\nhole\nTable 4\nTable 4\nCylindrical Knob Type Weights - Dimension for Loading Hole Variety I and II in mm.\nDenominations\nA\nB\nC\nD\nE\nF\nG\nL\nT\nI\nM\nN\nP\nS\n20g\n3\n18\n5.5\n2.5\n6.5\n1.5\n1\n9\nM4 x 0.5\n5\n1\n5\n5\n1\n50g\n4.5\n25\n7.5\n3.5\n9\n2\n1\n10\nM6 x 0.5\n5\n1.5\n7\n7\n1.5\n100g\n4.5\n30\n7.5\n3.5\n9\n2\n1\n10\nM6 x 0.5\n5\n1.5\n7\n7\n1.5\n200g\n7\n40\n10.5\n4.5\n12\n2.5\n1.5\n15\nM8 x 1\n8\n2\n10\n10\n2\n500g\n7\n50\n10.5\n4.5\n12\n2.5\n1.5\n15\nM8 x 1\n8\n2\n10\n10\n2\n1kg\n12\n65\n18.5\n7\n20\n4\n2.5.\n20\nM14 x 1.5\n13\n3\n18\n18\n3\n2kg\n12\n80\n18.5\n7\n20\n4\n2.5\n20\nM14 x 1.5\n13\n3\n18\n18\n3\n5kg\n18\n120\n24.5\n8\n26.5\n4\n2.5\n35\nM20 x 1.5\n18\n4\n24\n24\n3\n10kg\n18\n160\n24.5\n8\n26.5\n4\n2.5\n35\nM20 x 1.5\n18\n4\n24\n24\n3",
"footnote": "",
"is_definition": false,
"sort_order": 102
},
{
"number": "8",
"title": "8. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 103
},
{
"number": "9",
"title": "9. Permissible error",
"chapter": null,
"content": "Denomination\nPermissible\n\t\t\t\t\terror ________________________________\nVerification(mg)\nInspection(mg)\n10kg\n1500\n± 1500\n5kg\n750\n± 750\n2kg\n300\n± 300\n1kg\n150\n± 150\n500g\n75\n± 75\n200g\n30\n± 30\n100g\n15\n± 15\n50g\n10\n± 10\n20g\n8\n± 8\n10g\n6\n± 6\n5g\n5\n± 5\n2g\n4\n± 4\n1g\n3\n± 3",
"footnote": "",
"is_definition": false,
"sort_order": 104
},
{
"number": "10",
"title": "10. Stamping",
"chapter": null,
"content": "(a) The legal Metrology Officer's seals shall be stamped on the load pellet within the loading hole, where loading hole is provided.\n(b) The Legal Metrology Officer's seals shall be stamped on the bottom of weights which have no loading hole.\nC. - Iron Weights, Hexagonal (50 Kg to 50 g)",
"footnote": "",
"is_definition": false,
"sort_order": 105
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 106
},
{
"number": "2",
"title": "2. Shape",
"chapter": null,
"content": "(a) The weights shall be integral and hexagonal. The shape shall be as shown in Figures 6 and 6A;\n(b) The weights of denominations of 50 kg and down to and including 5 kg shall be provided with cast in handles made of mild steel.\n(c) The weights of denominations 2 kg and down to and including 50g shall nest with each other.",
"footnote": "",
"is_definition": false,
"sort_order": 107
},
{
"number": "3",
"title": "3. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 108
},
{
"number": "4",
"title": "4. Method of manufacture",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 109
},
{
"number": "5",
"title": "5. Loading hole",
"chapter": null,
"content": "(a) For weights in Figure 6, this hole must be in the shape of a right circular cone located axially and opening into the bottom face of the weight with its smaller diameter.\n(b) For weights in Figure 6A, this hole must be in the shape of a frustum of a pyramid with rectangular base and opening into the bottom face of the weight with its smaller end.\n(c) In the case of new weights about two-thirds of the depth of the loading hole shall remain empty after adjustment.",
"footnote": "",
"is_definition": false,
"sort_order": 110
},
{
"number": "6",
"title": "6. Marking",
"chapter": null,
"content": "(a) The denomination of the weights and the maker's or manufacturer's name or trade mark shall be indicated indelibly in the sunken form or in relief, on the upper surface of the central portion of the weight (See Figure 6).\n(b) The denomination of the weight shall be indicated in the international form of Indian numerals in indelible manner with the symbols as illustrated below (See Figure 6).\nNote : The abbreviation fdyks] fdxzk] xzk or xzke may be indicated in the regional script.\nNote :\nfdyks] fdxzk] xzk",
"footnote": "",
"is_definition": false,
"sort_order": 111
},
{
"number": "7",
"title": "7. Dimensions",
"chapter": null,
"content": "(a) The dimensions shall be as specified in Tables 5 and 5A.\n(b) The tolerances on dimensions shall be :\n(i) for weights 1 kg and below ± 10 per cent\n(ii) For weights above 1 kg ± 5 per cent.\nTable 5\nTable 5\nDimension for Cast Iron or Forged Mild Steel S Weights\n(All dimensions in millimetres)\nDenomination\nA\nB\nC\nD\nH\nP\nQ\nR\nS\nT\n2kg\n94\n101\n78\n41\n10\n34\n30\n9\n18\n4\n1kg\n73\n79\n62\n34\n8\n32\n28\n8\n16\n4\n500g\n57\n62\n47\n27\n6\n23\n20\n6\n13\n3\n200g\n42\n48\n38\n21\n6\n22\n20\n4\n9\n3\n100g\n33\n38\n31\n17\n5\n18\n16\n3\n7\n2.5\n50g\n27\n31\n24\n12\n3\n16\n14\n3\n5\n2\nTable 5A\nTable 5A\nDimensions of Cast Iron Weights with Cast-in Handles\n(Dimensions in mm)\nDenomination\nA\nB\nC\nD\nE\nG\nP\nQ\nR\nS\nT\n50kg\n236\n253\n134\n170\n100\n27\n58\n48\n24\n102\n32\n20kg\nl88\n200\n112\n113\n90\n21\n44\n38\n19\n66\n22\n10kg\n152\n161\n92\n88\n74\n18\n36\n30\n15\n54\n19\n5kg\n125\n132\n75\n65\n62\n15\n29\n25\n12\n40\n16",
"footnote": "",
"is_definition": false,
"sort_order": 112
},
{
"number": "8",
"title": "8. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 113
},
{
"number": "9",
"title": "9. Permissible error",
"chapter": null,
"content": "Denomination\nPermissible\n\t\t\t\t\terror _______________________________\nVerification(mg)\nInspection(mg)\n50kg\n7500\n± 7500\n20kg\n3000\n± 3000\n10kg\n1500\n± 1500\n5kg\n750\n± 750\n2kg\n300\n± 300\n1kg\n150\n± 150\n500g\n75\n± 75\n200g\n30\n± 30\n100g\n15\n± 15\n50g\n10\n± 10",
"footnote": "",
"is_definition": false,
"sort_order": 114
},
{
"number": "10",
"title": "10. Stamping",
"chapter": null,
"content": "D. - Bullion Weights (10 Kg to 1 g)",
"footnote": "",
"is_definition": false,
"sort_order": 115
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 116
},
{
"number": "2",
"title": "2. Shape",
"chapter": null,
"content": "(i) Cylindrical knob types - Cylindrical knob type weights of denomination 10 kg to 1 g, both inclusive shall be of the shape as specified in paragraph B-2 of this Part (see also Figure 5) but shall bear indications, specified in paragraph 6 to indicate that they are bullion weights.\n(ii) Flat cylindrical type - Flat cylindrical type weights of denominations 1 kg to 1 g both inclusive shall be flat cylindrical in shape, without a knob and shall nest with each other (See Figure 7).",
"footnote": "",
"is_definition": false,
"sort_order": 117
},
{
"number": "3",
"title": "3. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 118
},
{
"number": "4",
"title": "4. Method of manufacture",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 119
},
{
"number": "5",
"title": "5. Loading holes",
"chapter": null,
"content": "(a) Weights of denominations 10 kg to 20 g, both inclusive, made or manufactured according to requirements specified in paragraph 11 of this Part, shall have loading holes of the type specified for them.\n(b) Weights of denominations 10 g to 1 g, both inclusive of either type shall be solid integral weights without a loading hole.\n(c) Flat cylindrical weights from 1 kg to 20 g both inclusive, shall have loading holes, in the shape of a right circular frustum of a cone located axially and opening into the bottom face of the weight with its smaller diameter (See Figure 7).\n(d) In the case of new weights about two-thirds of the depth of the loading hole shall remain empty after adjustment.",
"footnote": "",
"is_definition": false,
"sort_order": 120
},
{
"number": "6",
"title": "6. Markings",
"chapter": null,
"content": "(a) The denominations and other marking on cylindrical knob type weights shall be as specified in paragraph 15 of this Part.\n(b) Cylindrical knob type weights of denomination 100g to 1g, both inclusive, shall be marked on the body with a 'diamond' and those of denominations 10 kg to 200g, both inclusive, shall be marked on the knob with the words 'Bullion' and cqfy;u within a 'diamond'.\ncqfy;u\n(c) The denominations of flat cylindrical weights and the maker's or manufacturer's name or trade mark shall be indicated indelibly, in the sunken form or in relief, on the upper surface of the central portion of the weights (See Figure 7).\n(d) Flat cylindrical weights of denominations 10 g to 1 g, both inclusive, shall be marked with only a 'diamond' and those of denominations 1 kg to 20 g, both inclusive, shall be marked with the words 'Bullion' and cqfy;u within a 'diamond'.\ncqfy;u\n(e) The denomination of the weight shall be indicated in the international form of Indian numerals in an indelible manner with the Symbols as illustrated below (See Figure 7):\nTable 6\nTable 6\nDimensions for Flat Cylindrical Bullion Weights\nDimensions for Flat Cylindrical Bullion Weights\n( All dimensions in millimetres )\nDenomination\nA\nB\nC\nD\nE\nF\nG\n1kg\n80\n61.5\n20\n23\n4.0\n12\n26.6\n500g\n61\n48.5\n16\n19\n2.5\n10\n22.5\n200g\n48\n37.5\n14\n16\n2.0\n7\n14.8\n100g\n37\n28.5\n12\n14\n2.0\n6\n12.7\n50g\n28\n21.5\n10\n11\n1.5\n3\n11.0\n20g\n21\n16.5\n9\n10\n1.5\n3\n8.4\n10g\n16\n12.5\n**\n**\n1.5\n**\n6.9\n5g\n12\n9.5\n**\n**\n1.0\n**\n5.9\n2g\n9\n7.0\n**\n**\n1.0\n**\n4.4\n1g\n6.5\n**\n**\n**\n**\n**\n3.6\nNote: The abbreviation fdyks] fdxzk] xzk or xzke may be indicated in the regional script.\nNote:",
"footnote": "",
"is_definition": false,
"sort_order": 121
},
{
"number": "7",
"title": "7. Dimensions",
"chapter": null,
"content": "(a) The dimensions of cylindrical knob type weights shall be as specified in Tables 3 and 4.\n(b) The dimensions of flat cylindrical weight shall be as specified in Table 6.\n(c) The tolerances on dimensions for both types of weights shall be -\n(i) for weights 1kg and below ± 10 per cent.\n(ii) for weights above 1kg ± 5 per cent.",
"footnote": "",
"is_definition": false,
"sort_order": 122
},
{
"number": "8",
"title": "8. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 123
},
{
"number": "9",
"title": "9. Permissible error",
"chapter": null,
"content": "Denomination\nPermissible ________________________________\nVerification(mg)\nInspection(mg)\n1\n2\n3\n10 kg\n500\n± 500\n5 kg\n250\n± 250\n2 kg\n100\n± 100\n1 kg\n50\n± 50\n500 g\n25\n± 25\n200 g\n10\n± 10\nl00 g\n5\n± 5\n50 g\n3\n± 3\n20 g\n2.5\n± 2.5\n10 g\n2.0\n± 2.0\n5 g\n1.5\n± 15\n2 g\n1.2\n± 1.2\n1 g\n1.0\n± 1.0",
"footnote": "",
"is_definition": false,
"sort_order": 124
},
{
"number": "10",
"title": "10. Stamping",
"chapter": null,
"content": "(a) The legal Metrology Officer's seals shall be stamped on the lead pellet within the loading hole, where loading hole is provided.\n(b) The Legal Metrology Officer's seals shall be stamped on the bottom of weights which have no loading hole.\nE. - Sheet Metal Weights",
"footnote": "",
"is_definition": false,
"sort_order": 125
},
{
"number": "1",
"title": "1. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 126
},
{
"number": "2",
"title": "2. Shape",
"chapter": null,
"content": "(a) Bullion weights shall be circular in shape and shall have one edge bent for ease of handling (See Figure 8).\n(b) Non-bunion weights shall have the following shapes and shall have one edge bent of ease of handling (See Figure 9).\nDenomination(mg)\nShape after bending along one of the sides\n5,50,500\nEquilateral triangle\n2,20,200\nSquare\n1,10,100\nRegular hexagon",
"footnote": "",
"is_definition": false,
"sort_order": 127
},
{
"number": "3",
"title": "3. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 128
},
{
"number": "4",
"title": "4. Method of manufacture",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 129
},
{
"number": "5",
"title": "5. Markings",
"chapter": null,
"content": "(a) Sheet metal weights shall bear only the denomination and symbol for 'milligram' as indicated below (see also Figure 8 and Figure 9).\nTable 7\nTable 7\nDimensions for Sheet Metal Weights\nDimensions for Sheet Metal Weights\n(Non-Bullion) (Figure 9) (All Dimensions Millimetres)\n(Non-Bullion) (Figure 9) (All Dimensions Millimetres)\nDenomination (mg)\nAl\nA2\nA3\nB\nH\n50\n14.0\n-\n-\n2.0\n3.0\n200\n...\n12.0\n...\n2.0\n3.0\n100\n...\n...\n12.0\n2.0\n2.5\n50\n8.0\n...\n...\n1.5\n2.5\n20\n...\n7.0\n...\n1.5\n2.5\n10\n...\n...\n7.0\n1.5\n2.5\n5\n4.5\n...\n...\n1.0\n2.0\n...\n4.0\n...\n1.0\n2.0\n...\n...\n4.0\n1.0\n2.0\nNote : The abbreviation fexzk may be indicated in the regional script.\nNote :\n(b) The maker's or manufacture's name or trade mark shall be indicated indelibly on the box containing the sheet metal weights.\n(c) The box shall also bear a serial number to identify it.",
"footnote": "",
"is_definition": false,
"sort_order": 130
},
{
"number": "6",
"title": "6. Dimensions",
"chapter": null,
"content": "(a) The dimensions of sheet metal weights shall be as specified in Tables 7 and 8.\n(b) The tolerances on dimensions shall be ± 10 per cent\nTable 8\nTable 8\nDimensions for Sheet Metal Weights (Bullion) (Figure 8)\nDimensions for Sheet Metal Weights (Bullion) (Figure 8)\n(All dimensions in millimetres)\nDenomination\nD\nC\nH\n500 mg\n15\n2.0\n3.0\n200 mg\n13\n2.0\n3.0\n100 mg\n11\n2.0\n2.5\n50 mg\n9\n1.5\n2.5\n20 mg\n8\n1.5\n2.5\n10 mg\n7\n1.5\n2.5\n5 mg\n6\n1.0\n2.0\n2 mg\n5\n1.0\n2.0\n1 mg\n4\n1.0\n2.0",
"footnote": "",
"is_definition": false,
"sort_order": 131
},
{
"number": "7",
"title": "7. Finish",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 132
},
{
"number": "8",
"title": "8. Permissible error",
"chapter": null,
"content": "Denomination(mg)\nMaximum permissible\n\t\t\t\t\terror ____________________________________________________\nVerification _________________________\nInspection _________________________\nBullion (mg)\nNon-bullion(mg)\nBullion (mg)\nNon-bullion(mg)\n1\n2\n3\n4\n5\n500\n0.8\n2.5\n± 0.8\n± 2.5\n200\n0.6\n2.0\n± 0.6\n± 2.0\n100\n0.5\n1.5\n± 0.5\n± 1.5\n50\n0.4\n1.2\n± 0.4\n± 1.2\n20\n0.3\n1.0\n± 0.3\n± 1.0\n10\n0.25\n0.8\n± 0.25\n± 0.8\n5\n0.20\n0.6\n± 0.20\n± 0.6\n2\n0.20\n0.6\n± 0.20\n± 0.6\n1\n0.20\n0.6\n± 0.20\n± 0.6",
"footnote": "",
"is_definition": false,
"sort_order": 133
},
{
"number": "9",
"title": "9. Stamping",
"chapter": null,
"content": "(a) Legal Metrology Officer's seals shall not be affixed on weights of 10 mg, 5 mg, 2 mg and 1 mg. These weights shall be Figure 8 authenticated by the issue of a certificate of verification which shall also mention the serial number on the box containing the weights.\n(b) Legal Metrology Officer's seal for year alone shall be stamped on sheet metal weights of 20 mg.\n(c) The Legal Metrology Officer's seals (namely, year, quarter and identification) shall be stamped on sheet metal weights of denominations 500 mg to 50 mg, both inclusive.\nPart II\nCarat Weights\nCarat Weights",
"footnote": "",
"is_definition": false,
"sort_order": 134
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 135
},
{
"number": "2",
"title": "2. Denomination.",
"chapter": null,
"content": "(a) KNOB WEIGHTS\n(b) SHEET METAL WEIGHTS\nDenomination carat\nEquivalent g\nDenomination carat\nEquivalent mg\n500\n100\n2\n400\n200\n40\n1\n200\n100\n20\n0.5\n100\n50\n10\n0.2\n40\n20\n4\n0.1\n20\n10\n2\n0.05\n10\n5\n1\n0.02\n4\n0.01\n2\n0.005\n1",
"footnote": "",
"is_definition": false,
"sort_order": 136
},
{
"number": "3",
"title": "3. Knob weights",
"chapter": null,
"content": "(a) Materials\n(i) The weights shall be made from rolled, drawn or extruded material and shall not be cast.\n(ii) The weights shall be made from brass, bronze, gun-metal, nickel chromium alloy or non-magnetic stainless steel.\n(b) Shape and dimensions\n(c) Permissible error\nDenomination Carat\nVerification (mg)\nInspection (mg)\n500\n5.0\n± 5.0\n200\n3.0\n± 3.0\n100\n2.5\n± 2.5\n50\n2.0\n± 2.0\n20\n1.5\n± 1.5\n10\n1.2\n± 1.2\n5\n1.0\n± 1.0\nTable 9\nTable 9\nNominal Dimensions of Knob Carat Weights\nNominal Dimensions of Knob Carat Weights\n[Clause 3(b)]\n[Clause 3(b)]\n(All dimensions in millimetres)\nDenominations Carat\nA*\nC**\nD\nE\nF\nG\nH\n500\n12.0\n0.4\n4.0\n10.0\n6.0\n32.0\n14.2\n200\n10.0\n0.4\n3.0\n8.5\n5.0\n23.0\n10.8\n100\n8.0\n0.4\n2.5\n7.0\n4.0\n19.0\n7.9\n50\n6.0\n0.3\n2.0\n5.5\n3.0\n15.0\n6.4\n20\n5.0\n0.3\n2.0\n4.0\n2.0\n11.0\n4.6\n10\n4.0\n0.3\n1.5\n3.0\n1.5\n9.0\n3.5\n5\n3.0\n0.2\n1.5\n2.5\n1.5\n7.0\n2.9\nNote : With a material of density 8400 kg/m 3 (exactly) the above dimensions will give weights which possess masses to within the required tolerance limits on the plus side (this ensures a longer life for the weights). However, as the density of the material may vary considerably as also the manufacturing techniques, a tolerance of ± 10 per cent is allowed on all obligatory dimensions (that is those other than C). Final values of masses can be adjusted by controlling the dimension H.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 137
},
{
"number": "4",
"title": "4. Sheet metal weights",
"chapter": null,
"content": "(a) Materials - Weights of denominations 0.2 carat and below shall be made of aluminium sheet. Weights of higher denominations shall be made of sheets of brass, aluminium, nickel-silver, nickel chromium alloy, bronze or cupro-nickel.\n(b) Shape and dimensions - Sheet metal weights shall be square with one edge bent for ease of handling (See Figure 11). They shall have dimensions given in Table 10.\n(c) Permissible error - The maximum permissible errors shall be as specified below :-\nDenomination Carat\nVerification mg\nInspection mg\n1\n2\n3\n2\n0.8\n± 0.8\n1\n0.6\n± 0.6\n0.5\n0.5\n± 0.5\n0.2\n0.4\n± 0.4\n0.1\n0.3\n± 0.3\n0.05\n0.25\n± 0.25\n0.02\n0.20\n± 0.20\n0.01\n0.20\n± 0.20\n0.005\n0.20\n± 0.20\nTable 10\nTable 10\nNominal dimension for sheet metal carat weights\nNominal dimension for sheet metal carat weights\nDenomination Carat\nSize mm\n2\n12\n1\n10\n0.5\n9\n0.2\n8\n0.1\n7\n0.05\n6\n0.02\n5\n0.01\n4\n0.005\n3",
"footnote": "",
"is_definition": false,
"sort_order": 138
},
{
"number": "5",
"title": "5. Manufacture and finish",
"chapter": null,
"content": "(a) The surface of the weights shall be reasonably smooth. Sheet metal weights shall be smoothly sheared and shall be free from burrs.\n(b) For better stability and finish, the weights may be nickel, or rhodium plated.",
"footnote": "",
"is_definition": false,
"sort_order": 139
},
{
"number": "6",
"title": "6. Marking",
"chapter": null,
"content": "(a) Every weight, except weights of 50 carat and lower denominations, shall have the manufacturer's name or trade mark and the denomination indelibly marked on it.\n(b) The denomination shall consist of the International form of Indian numeral prefixed and suffixed by the letter ^ds* and 'c' respectively except that in the case of weights below 50 carat, only the numerals shall be marked. The size of numerals and letters indicating the denomination of weights shall be at least twice the size of letters indicating the manufacturer's name or trademark.\n^ds*\nNote : The abbreviation ^ds* may be indicated in the regional script.\nNote :\n^ds*\n(c) The marking shall be legible and deep enough to ensure indelibility over a long period of use, but not so deep as to crack the weight itself.",
"footnote": "",
"is_definition": false,
"sort_order": 140
},
{
"number": "7",
"title": "7. Packing",
"chapter": null,
"content": "(a) Each set of carat weights shall, in addition to the series of denomination specified under 2, consist of an additional piece of weight of carat and the relevant decimal multiple of two.\n(b) The weights shall be supplied in a suitable velvet-lined box. The small sheet metal weights shall be so housed and provided with a cover of glass or any other transparent material that they was not get dislodged from their proper places. The box shall also contain a pair of forceps for lifting the weights.\nPart III\nStandard Weights for Testing of High Capacity Weighing Machines\nStandard Weights for Testing of High Capacity Weighing Machines",
"footnote": "",
"is_definition": false,
"sort_order": 141
},
{
"number": "1",
"title": "1. Scope",
"chapter": null,
"content": "(a) It sets forth the technical and metrological requirements to which these standard weights must conform. In particular it establishes the values of the maximum permissible errors for standard weights and minimum densities as functions of the maximum number of scale divisions on the machines to be verified using these weights.",
"footnote": "",
"is_definition": false,
"sort_order": 142
},
{
"number": "2",
"title": "2. Nominal values",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 143
},
{
"number": "3",
"title": "3. Shape",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 144
},
{
"number": "4",
"title": "4. Basis of adjustment",
"chapter": null,
"content": "(a) standard reference density: 8000 kg/m 3 ,\n(b) ambient air density: 1.2 kg/m 3 , and\n(c) equilibrium in air at 20°C, without correction for air buoyancy.",
"footnote": "",
"is_definition": false,
"sort_order": 145
},
{
"number": "5",
"title": "5. Adjusting cavity",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 146
},
{
"number": "6",
"title": "6. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 147
},
{
"number": "7",
"title": "7. Surface condition",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 148
},
{
"number": "8",
"title": "8. Metrological characteristics",
"chapter": null,
"content": "(a) the maximum number of scale divisions \"n\" on weighing machines under verification (assumed to be in accuracy class III);\n(b) the maximum permissible positive or negative relative error on standard weights used for initial verification of these machines; and\n(c) the corresponding lower limit for the density of the standard weights.\nTable\nTable\nMaximum number of scale divisions \"n\"\n\t\t\t\t\ton weighing machines (accuracy class III), capable of\n\t\t\t\t\tverification with the standard weights during verification\nMaximum permissible positive or negative\n\t\t\t\t\trelative error on the standard weights\nMinimum density kg/m 3\n(1)\n(2)\n(3)\n1000\n3.3/10000\n1231\n3000\n1.7/10000\n2087\n5000\n1.0/10000\n3000\n10000\n0.5/10000\n4364\nNote : Independent of the requirements concerning the density of the weights, it is desirable to obtain - particularly for reference standards or those of a high nominal value - a density of about 8000 kg/m 3 . For example, a cast iron body may be used, which incorporates a special cavity in which a lead core may be cast, with a mass of approximately 30 per cent of the total nominal mass of the standard.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 149
},
{
"number": "9",
"title": "9. Inscriptions and markings",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 150
},
{
"number": "10",
"title": "10. Adjustment and verification",
"chapter": null,
"content": "Note : Standard weights used for verification of a weighing machine with \"n\" scale divisions may be used for the re-verification of a weighing machine with \"p.n\" scale divisions, where the maximum permissible error for this re-verification is \"p\" times (where p has a value equal to or greater than 1), the maximum permissible error on verification.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 151
},
{
"number": "11",
"title": "11. Dimensions",
"chapter": null,
"content": "Annexure I\nAnnexure I\nAbsolute Errors for Standard Weights\nNormal value kg\nMaximum permissible error for the standard\n\t\t\t\t\tweights _____________________________________________\n3.3/10,000\n1.7/10000\n1/10000\n0.5/10000\nCorresponding absolute error (grams)\n50\n17\n8.5\n5\n2.5\n100\n33\n17\n10\n5\n200\n66\n33\n20\n10\n500\n170\n85\n50\n25\n1000\n330\n170\n100\n50\n2000\n660\n330\n200\n100\n5000\n17000\n850\n500\n250\n1000\n3000\n5000\n10000\nAnnexure II\nAnnexure II\nTypical Examples\na\nb\nc\n500kg\n273\n100\nØ 100\n1000kg\n504\n120\nØ 140\nRectangular Standard Weight 1000 kg Suitable for Stacking\nRectangular Standard Weight 1000 kg Suitable for Stacking\nCylindrical Standard Weights\nCylindrical Standard Weights\n500 kg and 1000 kg\nSuitable for Stacking and Rolling\nDimensions (mm) for 500 kg Weight\n[r = 10 R = 20]\nSixth Schedule\nSpecifications for Measures\nSpecifications for Measures\n[See Rule 12]\n[See Rule 12]\nPart I - Liquid Capacity Measures",
"footnote": "",
"is_definition": false,
"sort_order": 152
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 153
},
{
"number": "2",
"title": "2. Denominations",
"chapter": null,
"content": "Cylindrical\n\t\t\t\t\tmeasures ________________________________\nConical measures\nDipping type\nPouring type\n1 litre\n2 litres\n20 litres\n500 ml\n1 litres\n10 litres\n200 ml\n500 ml\n5 litres\n100 ml\n200 ml\n2 litres\n50 ml\n100 ml\n1 litre\n20 ml\n50 ml\n500 ml\n20 ml\n200 ml\n100ml",
"footnote": "",
"is_definition": false,
"sort_order": 154
},
{
"number": "3",
"title": "3. Shapes and dimensions",
"chapter": null,
"content": "(a) The shape and dimensions of cylindrical measures (dipping and pouring types) shall be as shown in Figures 12 and 13 and Table 11.\nTable 11\nTable 11\nNominal Dimensions of Cylindrical Capacity Measures\nDenominations\nD\nH\nB\nG\nMax\nMin\nMin\n(b) The shape and dimensions of conical measures shall be as shown in Figure 14 and Table 12.\nTable 12\nTable 12\nNominal Dimensions of Conical Capacity Measures\nNominal Dimensions of Conical Capacity Measures\nDenomination\nA\nB\nC\nD\nE\nF\nG Min.\nH\nJ\nK\nM\n20 litres\n97\n388\n288\n208\n194\n390\n1.00\n35\n86\n29\n30\n10 litres\n77\n308\n307\n174\n154\n309\n1.00\n30\n75\n26\n25\n5 litres\n61\n244\n245\n147\n122\n247\n0.80\n25\n65\n24\n20\n2 litres\n45\n180\n180\n118\n90\n182\n0.80\n20\n56\n22\n16\n1 litre\n36\n143\n143\n95\n72\n145\n0.63\n20\n45\n18\n16\n500 ml\n28\n114\n113\n74\n56\n115\n0.63\n15\n35\n14\n12\n200 ml\n21\n84\n84\n53\n42\n86\n0.63\n10\n24\n10\n8\n100 ml\n17\n66\n67\n41\n34\n69\n0.63\n10\n18\n7\n8\nNote 1 : All dimensions in millimetres.\nNote 1 :\nNote 2 : Tolerance on dimensions ± 10 per cent except in case of 10 litre and 20 litre measures for which the tolerance shall be ± 5 per cent.\nNote 2 :",
"footnote": "",
"is_definition": false,
"sort_order": 155
},
{
"number": "4",
"title": "4. Material",
"chapter": null,
"content": "(a) Cylindrical measures - The body of cylindrical measures shall be manufactured in one piece from aluminium alloy sheets, brass sheets or stainless steel sheets. The minimum thickness of the sheets shall be as specified in Table 11.\n(b) Conical measures - The conical measures shall be fabricated from galvanised steel sheets, aluminium alloy sheets, copper sheets, brass sheets, stainless steel sheets or tinplate. The minimum thickness of the sheets shall be as specified in Table 12.\n(c) The handles for the measures shall be fabricated from the same material as that used for the body.",
"footnote": "",
"is_definition": false,
"sort_order": 156
},
{
"number": "5",
"title": "5. Manufacture and finish",
"chapter": null,
"content": "(a) Cylindrical measures made of brass sheets and copper sheets shall be tinned or tin plated uniformly over the inside as well as the outside surfaces. Conical measures made of brass sheets or copper sheets, shall be well tinned or tin-plated uniformly all over the inside when they are used for measuring commodities like milk, edible oils and such other food articles.\n(b) The handles shall be of robust construction and shall be well formed and shaped generally as shown in Figure 12, 13 and 14. They shall be securely fixed to the body by means of riveting, soldering or brazing.\nNote 1: Capacity measures when used for measure milk shall have the handle fixed by welding, soldering or other suitable methods. Brazing so as not to leave pockets in which dirt may accumulate.\nNote 1:\nNote 2: Dipping type of cylindrical measures may also have handles substituted by two suitable but diagonally opposite brackets affixed to the walls of the measure by means of soldering, brazing or welding so as to hold the measure properly by a handle at right angles to the walls of the measures to facilitate its use in hot and boiled milk trade.\nNote 2:\n(c) The measures shall be free from any surface defects and indentations and shall be smoothly finished at the top.\n(d) Cylindrical measures shall be provided with a well formed and proportioned spout to facilitate pouring.\n(e) Conical measures shall be provided with a retaining lip to avoid spilling. The retaining lip shall be provided with plug of suitable material with a collar to receive the lead for the Legal Metrology Officer's seal. A small hole, about 5 mm in diameter shall be provided at the bottom of the retaining lip to indicate the level to which the measures shall be filled and the hole shall be located on the side at right angles to the handle. The bottom of conical measures shall be suitably reinforced.\n(f) The measures shall be so designed that, when they are tilted 120 degrees from the vertical, they shall become completely empty.\n(g) The finished measures shall have adequate robustness for durability.",
"footnote": "",
"is_definition": false,
"sort_order": 157
},
{
"number": "6",
"title": "6. Permissible error",
"chapter": null,
"content": "Denomination\nVerification\n\t\t\t\t\tin excess only ___________________________\nInspection ____________________________________\nCylindrical\n\t\t\t\t\tmeasures ml\nConical\n\t\t\t\t\tmeasures ml\nCylindrical\n\t\t\t\t\tmeasures ___________________________\nConical\n\t\t\t\t\tmeasures ___________________________\nExcess\nDeficiency\nExcess\nDeficiency\n\t\t\t\t\tml\n20 l\n...\n100\nError same\n\t\t\t\t\tas in verification\n...\nError same\n\t\t\t\t\tas in verification\n50\n10 l\n...\n50\n...\n25\n5 l\n...\n30\n...\n15\n2 l\n30\n15\n15\n7.5\n1 l\n20\n10\n10\n5\n500 ml\n15\n8\n7.5\n4\n200 ml\n8\n4\n5\n2\n100 ml\n5\n3\n2.5\n1.5\n50 ml\n3\n...\n1.5\n...\n20 ml\n2\n...\n1\n...",
"footnote": "",
"is_definition": false,
"sort_order": 158
},
{
"number": "7",
"title": "7. Marking",
"chapter": null,
"content": "(a) Every cylindrical measure shall have the denomination and manufacturer's name or trade mark indelibly stamped on it. In the case of conical measures, the denomination and manufacturer's name or trade-mark shall be either embossed on the body or indelibly marked on a name plate securely fixed to the body.\n(b) The denominations shall be indicated with the abbreviations 'l' and ^yh* for litre; and 'ml' and ^feyh* indicate millilitre.\n^yh*\n^feyh*\nNote : The abbreviation ^yh* or ^feyh* may be indicated in the regional script.\nNote :\n^yh*\n^feyh*",
"footnote": "",
"is_definition": false,
"sort_order": 159
},
{
"number": "8",
"title": "8. Stamping",
"chapter": null,
"content": "(a) Cylindrical capacity measures: The Legal Metrology Officer's seal shall be stamped just above the indication of the denomination of the capacity measure.\n(b) Conical capacity measures: The Legal Metrology Officer's seal shall be stamped on the lead pellet provided for this purpose.\nPart II\nDispensing Measures\nDispensing Measures",
"footnote": "",
"is_definition": false,
"sort_order": 160
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 161
},
{
"number": "2",
"title": "2. Types and denominations",
"chapter": null,
"content": "(a) Conical measures - 200 ml, 100 ml, 50 ml, 20 ml, 10 ml and 5 ml.\n(b) Beaker measures - 1000 ml and 500 ml.",
"footnote": "",
"is_definition": false,
"sort_order": 162
},
{
"number": "3",
"title": "3. Materials",
"chapter": null,
"content": "(a) Glass measures - The measures shall be made from clear and transparent glass. They shall be well annealed free from stones, cracks and chippings and as free as possible from blisters and other defects. Lead glass shall not be used for the measures.\n(b) Transparent plastic measures - The measures shall be made from a clear and transparent plastic material, manufactured from plasticised polyvinyl chloride or copolymer, the major constituent of which is polyvinyl chloride. The plastic materials used shall not contain any constituents known to be injurious to health and likely to be extracted by contact with liquids.",
"footnote": "",
"is_definition": false,
"sort_order": 163
},
{
"number": "4",
"title": "4. Definition of capacity",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": true,
"sort_order": 164
},
{
"number": "5",
"title": "5. Shape, construction, etc. of conical measures",
"chapter": null,
"content": "(a) Shape - The measures shall be conical as shown in Figure 15A to 15G. The 50 ml measures shall be either tall or squat as shown in Figure 15C and 15D respectively.\n(b) Construction -\n(i) Each measure shall have a pouring lip. The form of the lip shall be such that, when the measure is filled with water to the highest graduation mark, the contents may be poured from the lip in a stream falling clear of the outside of the measure.\n(ii) Each measure shall have a base on which it shall stand vertically without rocking when placed on a horizontal surface. The size of the base shall be such that the measure, when empty, shall not fall when placed on a plane inclined at 15° to the horizontal. The bottom of the measuring space shall be uniformly rounded and shall merge smoothly into the sides of the measure.\n(iii) The wall thickness of the measures shall be sufficient to ensure sturdy construction and shall not show any local departures from uniformity.\n(iv) The external surface of the measure shall be a cone having an included angle of not less than 13° and not more than 14°.\n(v) The overall volume of the measure shall be such that when it is filled with water to the highest graduation mark and a volume of water equal to half its nominal capacity is added to it, there shall be no overflow. But, the addition of a further quantity of water equal to quarter the nominal capacity shall result in water overflowing from the pouring lip.\n(c) Graduations -\n(i) The conical measures shall be graduated in accordance with Table 13.\n(ii) With the pouring dip of measure facing to the right, the front graduation marks shall be placed at right angles to and on the right hand side of a vertical line extending from above to the top graduation mark to near the base of the measure and below the bottom graduation mark.\n(iii) The graduation marks shall be marked as shown in Figure 15A to 15G. The marks shall be engraved or etched and they shall be of a uniform thickness not exceeding 0.3 mm., provided that they may taper slightly towards the ends. The graduation marks shall lie in planes perpendicular to the axis of the measure and shall be horizontal when the measure is standing on a horizontal surface.\n(iv) Each graduation number shall be etched or engraved close to the end of the graduation mark to which it relates and in such a manner that it would be bisected by a prolongation of that graduation mark.\n(v) The numbered graduation marks shall have the minimum length specified in Col. 7 of Table 13. The unnumbered graduation marks shall be at feast two third the length of the numbered graduation marks and clearly shorter than the numbered marks.\n(vi) The height of the lowest graduation mark above the lowest point of the bottom of the measuring space shall be within the limits given in Col. 6 of Table 13.\nTable 13\nTable 13\nDetails of Conical Measures\nDetails of Conical Measures\nDenomination\nGraduated At\nNumbered At\nBack Lines At\nLowest Graduation mark\nHeight of lowest graduation Mark above bottom of\n\t\t\t\t\tmeasuring space\nMinimum length of mark\n1\n2\n3\n4\n5\n6\n7\nml\nml\nml\nml\nml\ncm\ncm\n200\n50,100,120,140,160,180,200\n50,100,120,140,160,180.200\n50,100,200\n50\n6.5 + 0.5\n2.0\n100\nEvery 10ml from 10 to 100ml\n10,20,40,60,80,100,\n20,60,100\n10\n3.0 + 0.5\n1.75\n50(Tall)\nEvery 10ml from 10 to 50ml\n10,30,50\n30,50\n10\n4.0 + 0.5\n1.5\n50(Squat)\nEvery 10ml from 10 to 50ml\n10,30,50\n30,50\n10\n2.0 + 0.5\n1.5\n20\nEvery 5 ml from 5 to 20ml\n5,10,20\n10,20\n5\n2.5 + 0.5\n1.25\n10\nEvery ml from 2 to 10 ml\n2,4,6,8,10\n2,6,10\n2\n2.5 + 0.5\n1.0\n5\nEvery ml from 1 to 5ml\n1,3,5\n35\n1\n2.5 + 0.5\n0.75\n(d) Permissible errors - The maximum permissible errors on verification or on inspection shall be as specified below (in ml) :\nCapacity corresponding to graduation mark\nMeasures except 50 ml (Squat)\n50ml (Squat) measures\n(1)\n(2)\n(3)\n200, 180, 160\n± 3.0\n...\n140, 120, 100\n± 2.0\n...\n90, 80, 70,60\n± 1.5\n...\n50, 40\n± 1.0\n± 1.00\n30\n± 0.8\n± 1.00\n20\n± 0.6\n± 0.80\n15\n± 0.5\n-\n10, 9\n± 0.4\n± 0.80\n8, 7, 6\n± 0.3\n-\n5\n± 0.25\n-\n4\n± 0.20\n-\n3\n± 0.16\n-\n2\n± 0.12\n-\n1\n± 0.08\n-\nNote: The permissible errors, apart from those of the 50 ml squat measure, apply to graduation marks corresponding to the capacities stated, irrespective of the nominal capacity of the conical measure concerned.\nNote:",
"footnote": "",
"is_definition": false,
"sort_order": 165
},
{
"number": "6",
"title": "6. Shape construction, etc. of beaker measures",
"chapter": null,
"content": "(a) Shape - The measure shall be in the form shown in Figure 16A and 16B.\n(b) Construction -\n(i) Each measure shall be provided with a pouring lip. The form of the lip shall be such that, when the measure is filled with water to the highest graduation marks, the contents may be poured from the lip in a stream falling clear of the outside of the measure.\n(ii) Each measure shall be provided with a base on which it shall stand vertically without rocking when placed on a horizontal surface. The size of the base shall be such that the measure, when empty, shall not fall when, placed on a plane inclined at 15° to the horizontal. The bottom of the measuring space shall be uniformly rounded and shall merge smoothly into the sides of the measure.\n(iii) The overall volume of the measure shall be such that when the measure is filled with water to the highest graduation mark and a volume of water equal to quarter the denomination volume is added to it, the water shall not overflow.\n(c) Graduations -\n(i) The graduation marks shall be marked as shown in Figures 16A and 16B and Table 14. The marks shall be etched or engraved and shall be of a uniform thickness not exceeding 0.3 mm, provided that they may taper slightly towards the ends. The graduation marks shall lie in places perpendicular to the axis of the measures and shall be horizontal when the measure is standing on a horizontal surface.\n(ii) Each graduation numbered shall be etched or engraved close to the end of the graduation mark to which it relates and in such a manner that it would be bisected by a prolongation of that graduation mark.\n(iii) The distance between the highest and the lowest graduation marks and the height of the lowest graduation mark above the inside of the base of the measure shall be in (3) and (4) respectively of Table 14.\n(d) Permissible error - The maximum permissible errors on verification or on inspection shall be ± 7 ml for 1000 ml measures and ± 5 ml for 500 ml measure.",
"footnote": "",
"is_definition": false,
"sort_order": 166
},
{
"number": "7",
"title": "7. Marking",
"chapter": null,
"content": "^feyh*\nNote : The abbreviation ^feyh* may be indicated in regional script.\nNote :\nTable 14\nTable 14\nGraduation and Dimensions of Beaker Measures\nDenomination\nGraduation at\nDistance between lowest & highest graduation\n\t\t\t\t\tmarks\nHeight of lowest graduation mark above bottom of\n\t\t\t\t\tmeasuring surface\nDiameter of top\nMin. Diameter of base\nOverall height\n(1) ml\n(2)\n(3) cm\n(4) cm\n(*5) cm\n(*6) cm\n(7)\n1000\n200 to 1000 ml at each 100ml; numbered back lines at 200, 600\n\t\t\t\t\tand 1000 ml\n11±1\n4±1\n12\n9\n23\n500\n100 to 500ml at each 50 ml; numbered at each 100 ml;\n\t\t\t\t\tunnumbered back lines at 100,300 and 500\n9±0.5\n3±0.5\n10\n8\n18",
"footnote": "",
"is_definition": false,
"sort_order": 167
},
{
"number": "8",
"title": "8. Stamping",
"chapter": null,
"content": "Part III - Liquor Measures",
"footnote": "",
"is_definition": false,
"sort_order": 168
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 169
},
{
"number": "2",
"title": "2. Types",
"chapter": null,
"content": "(i) Hand operated, and\n(ii) Automatic,",
"footnote": "",
"is_definition": false,
"sort_order": 170
},
{
"number": "3",
"title": "3. Denominations",
"chapter": null,
"content": "Hand operated : 100 ml, 60 ml and 30 ml.\nAutomatic : 20 ml.",
"footnote": "",
"is_definition": false,
"sort_order": 171
},
{
"number": "4",
"title": "4. Material",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 172
},
{
"number": "5",
"title": "5. Shapes and dimensions",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 173
},
{
"number": "6",
"title": "6. Manufacture",
"chapter": null,
"content": "(a) Liquor measures made of brass sheet shall be well tinned or silver-plated uniformly all over the inside as well as the outside surface.\n(b) Hand operated liquor measures shall be well formed. Measures of 60 ml and 30 ml capacity may be joined together with a common stem by brazing.\n(c) The measures shall be free from any surface defects and indentations and shall be smoothly finished.\n(d) Automatic liquor measures shall be capable of delivering 30 ml of liquor when tilted at an angle of 120 from the vertical.\n(e) Hand operated liquor measures shall have a knurled edge.",
"footnote": "",
"is_definition": false,
"sort_order": 174
},
{
"number": "7",
"title": "7. Permissible error",
"chapter": null,
"content": "Denomination\nPermissible error\n100 ml\n± 3 ml\n60 ml\n± 2 ml\n30 ml\n± 1 ml",
"footnote": "",
"is_definition": false,
"sort_order": 175
},
{
"number": "8",
"title": "8. Markings",
"chapter": null,
"content": "(a) Every liquor measure shall have the denomination and manufacturer's name or trade mark legibly and indelibly marked on it.\n(b) The denomination shall consist of international form of Indian numerals and the abbreviations 'ml' and ^feyh* to indicate millilitres. The size of numerals shall be twice the size of the letters indicating the manufacturer's name or trademark.\n^feyh*\nNote : The abbreviation ^feyh* may be indicated in the regional script.\nNote :\n^feyh*",
"footnote": "",
"is_definition": false,
"sort_order": 176
},
{
"number": "9",
"title": "9. Stamping",
"chapter": null,
"content": "Part IV - Length Measures\n(Non-Flexible)\n(Non-Flexible)",
"footnote": "",
"is_definition": false,
"sort_order": 177
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 178
},
{
"number": "2",
"title": "2. Denominations",
"chapter": null,
"content": "Metallic measures\nWooden measures\n1m\n2m\n0.5m\n1m\n0.5m",
"footnote": "",
"is_definition": false,
"sort_order": 179
},
{
"number": "3",
"title": "3. Material, shape, etc. of metallic measures",
"chapter": null,
"content": "(a) Material - The measures shall be made from mild steel/brass or stainless steel.\n(b) Shape and dimensions - The shape and dimensions of the measures shall be as is shown in Figure 20.\n(c) Graduations - The graduation marks shall be made at every centimetre or at every centimetre for the first ten centimetres and thereafter at every five centimetres. The graduation marks at every ten centimetres shall be numbered. The marks at the centimetre divisions shall extend over half the breadth and those at five centimetre divisions over full breadth of the measures. A cross mark shall be provided at 25 cm in the case of 0.5 m measure and at 25,50 and 75 cm in the case of 1 m measure (See Figure 20). The graduations shall be only on one side of the measure.\n(d) Permissible error - The error on the length between any two consecutive five centimetre graduation marks shall not exceed ± 0.25 mm and further the error from the beginning of the measure to any graduation mark shall not exceed 1.0 mm for 1 metre bar and 0.5 mm for half metre bars provided that the errors on the full length of the measures shall not exceed the fallowing limits :\nDenomination\nVerification\nInspection\nExcess\nDeficiency\nExcess\nDeficiency\n1 m\n1.0 mm\n0.5 mm\n1.0 mm\n1.0 mm\n0.5 m\n0.5 m\n0.25 mm\n0.5 mm\n0.5 mm\n(e) Provision for stamping - The measures shall be provided with a copper rivet near each end (see Figure 20) firmly fixed in a hole, countersunk on both sides, for the legal Metrology Officer's stamp. An arrow head shall be marked at each end of the measure to provide the points for checking the length.",
"footnote": "",
"is_definition": false,
"sort_order": 180
},
{
"number": "4",
"title": "4. Material, shape, etc. of wooden measures",
"chapter": null,
"content": "(a) Materials - The measure shall be made from well seasoned timber of anyone of the following species :-\n(a) Teak ( Tectona grandis Linn. f )\n(b) Roseweed ( Delbergia Latifolia Roxb )\n(c) Shisham ( Dalbergia sissoo Roxb )\n(d) Haidu ( Adhina cordifolia Hoock. f )\n(e) Bijasal ( Pterocarpus marsupium Roxb )\n(f) Boxwood ( Biaxux sempervirens )\n(g) Beech ( Fagus syivatica )\n(b) Shape and dimensions - The shape and dimensions of the measures shall be as shown in Figure 21.\n(c) Graduations - The graduation marks shall be made at every centimetre for the first ten centimetres and thereafter at every five centimetres. The graduation marks at every ten centimetres shall be numbered, The marks at the centimetre divisions shall extend over half breadth and those at every five centimetre division over the full breadth of the measures. A cross mark shall be provided at every 25cm, excluding the one metre and two metre graduations. (See Figure 21) Last and first marks shall coincide with the end faces.\n(d) Permissible error - The error on the length between any two consecutive five centimetre graduation marks shall not exceed ± 1 mm, and further the error from the beginning of the measures to any graduation marks shall not exceed 2 mm, for 2 metre bar; 1 mm for 1 metre bar and 0.5 mm for half metre bar provided that the errors on the full length of the measure shall not exceed the following limits :\nDenomination\nVerification _______________________\nInspection _______________________\nExcess\nDeficiency\nExcess\nDeficiency\n2 m\n4 mm\n2 mm\n4 mm\n4 mm\n1 m\n2 mm\n1 mm\n2 mm\n2 mm\n0.5 mm\n1 mm\n0.5 mm\n1 mm\n1 mm\n(e) Provision for stamping - Each measure shall be provided at each end with a metal tip not less than 1 cm in width, securely riveted with two rivets at each end, as shown in Figure 21 for receiving the Legal Metrology Officer's stamp. The width of the tips shall be included in the total length of the measure.",
"footnote": "",
"is_definition": false,
"sort_order": 181
},
{
"number": "5",
"title": "5. Manufacture and finish",
"chapter": null,
"content": "(a) The measure shall be evenly finished and shall be reasonably straight.\n(b) In the case of metallic measures, the graduation marks and the cross marks shall be legible and deep enough to ensure indelibility over a reasonably long period of use, but not so deep as to make the measures liable to be easily bent. In the case of wooden measures, the markings shall be finished neatly, sharply and legibly, in a colour contrasting with the wood finish. They shall be visible from a distance and shall remain indelible over a reasonably long period of use.",
"footnote": "",
"is_definition": false,
"sort_order": 182
},
{
"number": "6",
"title": "6. Marking",
"chapter": null,
"content": "(a) The denomination shall be stamped on the ungraduated side of the measure at about one-third of the total length from the beginning of the measure and the manufacturer's name or trade mark at a similar distance from the end of the measure. In the case of wooden measures, the markings shall be finished in the same manner as the graduations.\n(b) In indicating the denominations the numerals shall be preceded by the word ^ehVj* and followed by metre. The size of numerals and letters, indicating denominations of the measures shall be twice the size of the letters indicating the manufacturer's name or trade mark.\n^ehVj*\n(c) The end of the measure shall be marked on the graduated side with the International form of Indian numeral Indicating the denomination, preceded and followed by the letters ^eh* and 'm'.\n^eh*\nNote : The word and abbreviation ^ehVj* or ^eh* may be indicated in the regional script.\nNote :\n^ehVj*\n^eh*\nPart V - Folding Scales",
"footnote": "",
"is_definition": false,
"sort_order": 183
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 184
},
{
"number": "2",
"title": "2. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 185
},
{
"number": "3",
"title": "3. Materials",
"chapter": null,
"content": "(a) The scales shall be made from strips or sheets of wood. They shall be reasonably uniform, in width and thickness throughout the entire length.\n(b) The scales shall be made of any one of the following species of timbers:-\n(i) Boxwood (Buxus sempervirens)\n(ii) Gardenia (Gardenia sp)\n(iii) Parrotia (Parrotia jucquemontiana)(Randia dumetorum)\n(iv) Dudhl (Wrightia sp)\n(v) Bamboo.\n(vi) Haldu (Adina cordifolia Hoock f.)\n(vii) Kalam (Mitragyna parvifolia korth)\n(viii) Kuthan (Hymenodictyon excelsum wall)\n(ix) Gamri ( Gmelina abrorea Linn )\n(c) The timbers shall be thoroughly seasoned and radially sawn. The moisture content of the timber shall be between 8 and 12 per cent. The timber shall be free from knots, cracks, sap wood, snakes and other visible defects such as decay, insect attack, etc. and shall be fairly straight-grained.",
"footnote": "",
"is_definition": false,
"sort_order": 186
},
{
"number": "4",
"title": "4. Manufacture",
"chapter": null,
"content": "(a) General - The scales shall be reasonably straight and flat, the edges parallel to each other and the ends reasonably square.\n(b) No point on any of the edges shall be more than 0.5 mm distant from the straight line connecting its extremities. No point on the surface of a scale shall be more than 0.5 mm distant from the plane of the surface.\n(c) The scales shall consist of four pieces hinged together and it shall be an end measuring scale. (First and last graduation shall be the end face). The joints shall work smoothly without undue play and shall be sufficiently free from the folds to be opened and closed without strain. The brass caps shall be closely fitted and strongly secured to the blades. They shall be made flush with the sides of the scales.\n(d) A protective layer of suitable lacquer or varnish or any other suitable material shall be provided.",
"footnote": "",
"is_definition": false,
"sort_order": 187
},
{
"number": "5",
"title": "5. Dimensions",
"chapter": null,
"content": "Length of graduated part (m)\nWidth max. (mm).\nMin. (mm)\nThickness(mm)\n0.5\n15.0\n14.5\n4 ± 1\n1\n20.0\n19.0\n5 ± 1",
"footnote": "",
"is_definition": false,
"sort_order": 188
},
{
"number": "6",
"title": "6. Graduations",
"chapter": null,
"content": "(a) Graduation marks shall be made at every millimetre with a longer line at every 5 mm and centimetre. The length of the graduation lines shall be as follows:\ncm marks 6 mm\n5 mm marks 4 mm\n1 mm marks 2.5 mm\n(b) The lines shall be fine and clear, of uniform depth and thickness, and perpendicular to the edges. The thickness of lines shall be not more than 0.2 mm for stamped scales and 0.1 mm for engine divided scales. The lines shall be of sufficient depth to be legible and indelible.\n(c) The lines shall be filled in black and natural background or with a suitable colour which shall contrast with the colour of the base to ensure legibility.\n(d) Every centimetre shall be numbered in international form of Indian numerals. The height of the figures shall be between 2.0 and 2.5 mm.",
"footnote": "",
"is_definition": false,
"sort_order": 189
},
{
"number": "7",
"title": "7. Permissible error",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 190
},
{
"number": "8",
"title": "8. Marking",
"chapter": null,
"content": "(a) The denomination shall be stamped on the ungraduated side of the measure at a distance about one-third of the total length from the beginning of the measure. The manufacturer's name or trade mark shall be indicated indelibly at the same distance from the other end of the measure. The markings shall be finished in the same manner as the graduations.\n(b) In indicating the denominations the numerals shall be preceded by the word ^ehVj* and followed by 'metre'.\n^ehVj*\nNote : The word ^ehVj* may be indicated in the regional script.\nNote :\n^ehVj*",
"footnote": "",
"is_definition": false,
"sort_order": 191
},
{
"number": "9",
"title": "9. Stamping",
"chapter": null,
"content": "Part VI - Fabric or Plastic Tape Measure",
"footnote": "",
"is_definition": false,
"sort_order": 192
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "(a) This Part deals with fabric or plastic tape measures, which are used for measurements, where the use of rigid length measures is not convenient or practicable.\n(b) Tape measures of 0.5 m to 5 m, made of materials specified in clause 4(b), are intended to be used for measurements required in the tailoring trade, anatomical measurements or household measurements. Tape measures of 5 m and above made of materials specified in clause 4(c) are intended to be used for measurements of buildings, roads, timber and timber products and for other similar measurements but not for measurements of land, storage tanks, fermentation vats and other similar measurements.",
"footnote": "",
"is_definition": false,
"sort_order": 193
},
{
"number": "2",
"title": "2. Classes of accuracy",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 194
},
{
"number": "3",
"title": "3. Nominal lengths",
"chapter": null,
"content": "Note : The nominal length of a fabric or plastic tape measure is the distance at the reference temperature of 20°C between the initial and terminal graduation lines, when the tape measure is stretched, in the wet or dry condition, and without friction on a horizontal plane surface, under an extension of 20 newtons. The length so measured shall be equal, within the limits of maximum permissible errors, to the nominal length of the tape measure.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 195
},
{
"number": "4",
"title": "4. Material",
"chapter": null,
"content": "(a) The materials used shall be adequately strong, stable and resistant to atmospheric conditions under the normal conditions of use and shall comply with the following requirements :-\n(i) When ordinarily used at temperatures between ± 8°C of the reference temperature, the variation in length of the tape measure shall not exceed the maximum permissible error.\n(ii) When used with a change of ± 10 per cent in the tension, the variation in length of the tape measure shall not exceed the maximum permissible error.\n(b) Tape measures of nominal length 0.5 m to 5 m:\n(i) The tape measure may be made from a suitable fabric or plastic material.\n(ii) The fabric shall be coated with suitable paints, enamels or other suitable coating so as to give the tape measure a good finish. All coatings shall be non-cracking and water resistant.\n(c) Tape measure of nominal length above 5m:\n(i) If made from fabrics, the fabric may be reinforced length-wise with rust proof and rigid wires of metal or other equivalent material.\n(ii) If made from plastic materials, the tape measure shall be reinforced length-wise by means of rust-proof and rigid wires of metal or glass fiber.\n(iii) If made from any other material, the tape measure shall satisfy the conditions specified in clause 4(a).",
"footnote": "",
"is_definition": false,
"sort_order": 196
},
{
"number": "5",
"title": "5. Manufacture",
"chapter": null,
"content": "(a) General:\n(i) Tape measures shall be well-made, robust and carefully finished.\n(ii) The cross-section of the tape measures shall have such dimensions and shape that, under normal conditions of use it allows the tape measure to have the accuracy specified for its class.\n(iii) Tape measures shall be so made that when they are stretched over a plane surface their edges are practically straight and parallel.\n(iv) The rings, winding, devices or other devices shall be attached to the tape in such a manner that they do not cause any inaccuracy or permanent deformation in the tape.\n(b) Tape measures of nominal length 0.5m to 5m:\n(i) Tape measures of nominal length 0.5m to 5m shall have a width of not less than 5 mm and not more than 25 mm.\n(ii) If not wound on a spool or in a case, both the ends of the tape measure shall be reinforced with plastic or metal strips, of the same width as the tape measure, over a length of not less than 10 mm or more than 100mm.\n(iii) If wound on a spool or in a case, the tape measure shall have a metal ring or other device securely attached to the outer end of the tape measure. A device, retraction or winding of the tape shall be provided.\n(c) Tape measure of nominal length above 5m :\n(i) The tape measures shall have a width of not less than 10 mm and a thickness between 0.3 and 0.6 mm.\n(ii) A metal ring shall be securely attached to the outer end of each tape measure. The ring shall be securely fastened to the tape measure by a metal strip of the same width as the tape.\n(iii) The outer end of the tape measure shall be reinforced over a length of not less than 100 mm by a strip of leather or other suitable material of the same width as the tape measure the strip shall pass round the inner end of the ring and under the metal strip.\nNote : This strip, besides serving as a protective device shall also be utilised for affixing the stamp of verification.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 197
},
{
"number": "6",
"title": "6. Graduations",
"chapter": null,
"content": "(a) General requirements:\n(i) Graduation lines shall be clear, uniform, indelible and so made as to ensure easy and unambiguous reading.\n(ii) The value of the graduations shall be of the form 1 x 10 n , 2 x 10 n or 5 x 10 n , the exponent \"n\" being positive or negative whole number or zero. The value of the graduation, however, shall not exceed :\n1 cm, on measures of nominal length less than or equal to 2 m,\n10 cm, on measures of nominal length more than 2 m, but less than 10 m,\n20 cm, on measures of nominal length more than 10 m, but less than 50 m,\n50 cm, on measures of nominal length equal to or more than 50 m.\n(iii) Graduation lines shall be reasonably straight, perpendicular to the axis of the tape measures and of uniform thickness throughout the length.\n(iv) Graduations lines shall be so made that they form a clear and distinct scale and their thickness does not cause any inaccuracy of reading.\n(b) Tape measures of nominal length 0.5 m to 5m:\n(i) The zero graduation line may be located at the outer end of the ring or other device or may commence on the tape itself at a length equal to or greater than 50 mm from the outer end of the ring or other device.\n(ii) The tape measures may be graduated throughout at every millimetre or every 5 mm.\n(iii) The graduation lines at every 10 mm shall be marked in such a manner that there is no confusion between the 10 mm lines and the millimetre or 5 mm lines.\n(iv) The tape measures may be graduated on one side or both the sides. If the tape is graduated on one side, the manufacturer's name, trade mark, advertisement or other similar matter may be printed on the ungraduated side of the tape measure.\n(c) Tape measures of nominal length above 5m:\n(i) The zero graduation line may be located at the outer end of the metal ring or on the tape itself, at a length equal to or greater than 100 mm from the outer end of the ring.\n(ii) The tape measure may be graduated at every millimetre, every 5 millimetre or every 10 millimetre.\n(iii) The graduation lines at every 10 mm shall be marked in such a manner that there is no confusion between the 10 mm graduation lines and the millimetre or 5 mm graduation line.\n(iv) The graduation lines at every 10 m shall have a length approximately half the width of the tape.\n(v) Every graduation line at 50 mm shall have the same length as the graduation line at 10 mm but may have an arrow at its end. This requirement shall not apply to tape measures graduated at every millimetre.\n(vi) The zero graduation line, the graduation lines at every 100 millimetres and at every metre shall have a length equal to the width of the tape.",
"footnote": "",
"is_definition": false,
"sort_order": 198
},
{
"number": "7",
"title": "7. Numbering",
"chapter": null,
"content": "(a) General requirements:\n(i) The numerals shall be indicated clearly, uniformly and indelibly and shall be easily and unambiguously legible.\n(ii) The places, dimensions, shape, colour and contrast of the numerals shall be suitable for the scale and graduation lines to which they relate.\n(iii) The numerals shall be marked parallel to or perpendicular to the axis of the tape measure depending upon the intended manner of use of the measure.\n(b) On tape measures of nominal length 0.5 m to 5m:\n(i) Every graduation line at 10 mm shall be marked with the complete number of centimetre.\n(ii) The height of the numerals shall not exceed two-thirds the width of the tape measures.\n(c) On tape measures of nominal length above 5m:\n(i) The graduation lines at every 100 mm and at every metre shall be numbered. The numerals shall have a height of not more than two-thirds of the width of the tape.\n(ii) the metre graduations shall be accompanied by the symbol 'm' and, if required, ^eh* .\n^eh*\nNote : The abbreviation ^eh* may be indicated in the regional script.\nNote :\n^eh*\n(iii) After the graduation line at one metre, every graduation line at 100 mm may be marked with an additional numeral indicating the completed number of metres. This numerals, if provided, may be located just above, below or in line with the numeral of the 100 mm graduation line. The height of the numeral may be approximately half the height of the numerals indicating 100 mm.",
"footnote": "",
"is_definition": false,
"sort_order": 199
},
{
"number": "8",
"title": "8. Maximum permissible error",
"chapter": null,
"content": "(i) On verification, under the conditions specified in clause 2, the error on the length between the axis of any two graduation lines shall not exceed :\nfor Class I ± (0.1 + 0.1L) mm\nfor Class II ± (0.3 + 0.2L) mm; and\nfor Class III ± (0.6 + 0.4L) mm;\n(ii) The maximum permissible error on tape measures on inspection shall be twice that specified for verification, the methods of verification remaining unchanged.\n(iii) Tape measure of nominal length 0.5 m to 5 m shall belong to accuracy Class II or Class III.\n(iv) Tape measures of nominal length above 5 m shall belong to accuracy Class I, Class II or Class III.",
"footnote": "",
"is_definition": false,
"sort_order": 200
},
{
"number": "9",
"title": "9. Markings",
"chapter": null,
"content": "(a) Tape measures of nominal length 0.5 m to 5m :\n(i) nominal length in metres.\n(ii) manufacturer's name or trade mark or both.\n(iii) class of accuracy II or III in an oval.\n(iv) an indication of the location of zero on the scale.\n(v) model approval number issued by the central Government.\n(b) Tape measure of nominal length above 5 m:\n(i) nominal length in metres.\n(ii) manufacturer's name or trade mark or both,\n(iii) class of accuracy: I, II or III in an oval.\n(iv) an indication of the location of zero on the scale.\n(v) model approval number Issued by the central Government.\n(c) The inscription shall be clearly visible and legible.\n(d) Advertising inscriptions, if made, shall be carried out of such a manner that they did not intrude in any way with the use of the tape measure.",
"footnote": "",
"is_definition": false,
"sort_order": 201
},
{
"number": "10",
"title": "10. Sealing",
"chapter": null,
"content": "Part VII - Steel Tape Measures",
"footnote": "",
"is_definition": false,
"sort_order": 202
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 203
},
{
"number": "2",
"title": "2. Classes of accuracy",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 204
},
{
"number": "3",
"title": "3. Nominal lengths",
"chapter": null,
"content": "Note : The nominal length of a steel tape measure is the distance at the reference temperature of ± 20°C, between the initial and terminal graduation lines, when the tape measure is stretched, without friction, on a horizontal plane surface, under a tension of 50 newtons. The length so measured shall be equal, within the limits of maximum permissible errors, to the nominal length of the tape measures.\nNote :",
"footnote": "",
"is_definition": false,
"sort_order": 205
},
{
"number": "4",
"title": "4. Materials",
"chapter": null,
"content": "(a) The materials used shall be adequately strong, stable and resistant to environmental influences under normal conditions of use and shall comply with the following requirements :\n(i) when ordinarily used at temperatures between ± 10°C of the reference temperature, variation in length of the tape measure shall not exceed the maximum permissible error;\n(ii) when used with a change of ± 10% in the tensions, the variation in length of the tape measure shall not exceed the maximum permissible error.\n(b) The tape measure shall be made from steel or stainless steel.",
"footnote": "",
"is_definition": false,
"sort_order": 206
},
{
"number": "5",
"title": "5. Manufacture",
"chapter": null,
"content": "(a) Tape measures shall be well made, robust and carefully finished. (See Figure 22 to 26).\n(b) The cross section of the tape measures shall have such dimensions and shape that, under normal conditions of use, it allows the tape measures to have the accuracy specified for its class.\nNote : It is recommended for guidance of manufacturer and users that tape measure may have a width of not less than 5 mm and a maximum thickness of 0.4 mm.\nNote :\n(c) The steel tape measure shall be so made that when it is stretched on a plane surface, the edges are practically straight and parallel.\n(d) At the zero end, tape measures shall be provided, with a ring or other device for facilitating withdrawal. The ring or other device, when provided, shall be fastened to the tape measure by a metal strip of the same width as the tape.\n(e) The tape measures shall be capable of being wound into suitable container or other winding device of robust construction and made of metal, plastic, leather or other suitable material.\n(f) The winding devices shall be so designed that they do not cause any inaccuracy or permanent deformation in the tape.\n(g) The edges of tape measures shall be slight rounded.\n(h) The tape measure shall be provided with rust proof coating and shall be free from burrs.",
"footnote": "",
"is_definition": false,
"sort_order": 207
},
{
"number": "6",
"title": "6. Graduations",
"chapter": null,
"content": "(a) General requirements\n(i) Graduation lines shall be clear, uniform, indelible and so made as to ensure easy and unambiguous reading.\n(ii) The value of the graduations shall be of the form 1 x 10 n , 2 x 10 n or 5 x 10 n metre where the exponent 'n' being a positive or negative whole number or zero.\nThe value of the graduations, however, shall not exceed:\n1 cm, on measures of nominal length less than or equal to 2 m,\n10 cm, on measures of nominal length more than 2 m but less than 10 m,\n20 cm, on measures of nominal length more than 10 m, but less than 50 m,\n50 cm, on measures of nominal length equal to or more than 50 m.\n(iii) Graduation lines shall be reasonably straight, perpendicular to the axis of the tape measure, and of uniform thickness though out their length.\n(iv) Graduation lines shall be so made that they form a clear and distinct scale and that their thickness does not cause any inaccuracy of reading.\n(b) Tape measures above 5 m to 200 m shall be graduated only on one side. Tape measures of 0.5 m to 5 m may be graduated on both sides (Only metric scale).\n(c) The graduated lines, numbers and other markings shall be either in relief, engraved, typographically printed or made in any other suitable manner.\n(d) The zero of the scale may be located at the outer or inner edge of the ring or other device, or may also be located on the tape measure itself, at a length equal to or greater than:\n(i) 50 mm from the outer end of the ring or other device, in the case of tape measures of nominal length 0.5 m to 5 m; and\n(ii) 100 mm from the outer end of the ring or other device, in the case of tape measures of nominal lengths above 5 m.\n(e) Tape measure of denominations 0.5 m to 5 m may be graduated throughout at every millimetre, every 5 millimetre or every 10 millimetre.\n(i) The graduation lines at every 10 mm shall be marked in such a manner that there is no confusion between the 100 mm graduation lines and the millimetre or 5 mm graduation lines.\n(ii) In the case of tape measures graduated at every 5 mm or 10 mm, not less than the first 100 mm shall be subdivided into millimetre.\n(f) In the case of tape measures of nominal length above 5 m, every graduation line at 50 mm shall have the same length as the graduation line at 10 mm but may have an arrow at its end. This requirement shall not apply to tape measures graduated at every millimetre.\n(g) The thickness of the graduation lines shall not exceed the following limits :\n(h) In the case of tape measures of nominal length 0.5 m to 5 m, the graduation lines may have a length between one-fourth and full width of the tape, depending upon convenience. In the case of tape measures of nominal length above 5m, the length of the graduation lines may be as follows :-\n(i) for millimetre graduation lines, about one-third of the width of the tape;\n(ii) for 5 millimetre graduation lines, about half the width of the tape;\n(iii) for 10 millimetre graduation tines, about two-thirds the width of the tape; and\n(iv) for 100 millimetre graduation lines and for metre graduation lines as well as for the zero graduation lines, equal to the width of the tape.",
"footnote": "",
"is_definition": false,
"sort_order": 208
},
{
"number": "7",
"title": "7. Numbering",
"chapter": null,
"content": "(a) General requirements:\n(i) The numerals shall be indicated clearly, uniformly and indelibly and shall be easily and unambiguously legible.\n(ii) The places, dimensions, shape, colour and contrast of the numerals shall be suitable for the scale and graduation lines to which they relate.\n(iii) The numerals shall be marked parallel to or perpendicular to the axis of the tape measure depending upon the intended manner of use of the measure.\n(b) The following graduation lines shall be numbered :\n(c) The metre graduation lines shall be numbered and accompanied by the symbol 'm' and if required ^eh* .\n^eh*\nNote : The abbreviation ^eh* may be indicated in the regional script.\nNote :\n^eh*\n(d) In the case of the tape measure of nominal length of 0.5 m to 5 m, the height of the numerals shall be such as would facilitate the reading of the measurement without ambiguity.\n(e) In the case of tape measures of nominal length 5 m and above, after the graduation line at one metre, every graduation line at 100 mm may be marked with an additional numeral indicating the completed number of metres. This numeral, if provided, may be located just above or in line with the numeral of the 100 mm graduation line. The height of this numeral may be approximately half the height of the numerals indicating 100 mm.\n(f) In the case of tape measures of nominal length 5 m and above the height of the numerals, except those given in sub-clause (e) of clause 7 may be:\n(i) about 1/3 of the width of the tape, for 10 mm graduation lines,\n(ii) about 1/2 of the width of the tape, for 100 mm graduation lines, and\n(iii) about 2/3 of the width of the tape, for metre graduation lines.\n(g) If tapes of 0.5 m to 5 m are contained in special container may be marked with its dimension, for example, 50 mm, to facilitate measurement of internal dimensions.",
"footnote": "",
"is_definition": false,
"sort_order": 209
},
{
"number": "8",
"title": "8. Maximum permissible error",
"chapter": null,
"content": "(a) On verification, under the conditions specified in clause 2, the error on the length between the axis of any two graduation lines shall not exceed:\nfor Class I ± (0.1 + 0.1L) mm,\nfor Class II ± (0.3 + 0.2L) mm,\nand for Class III ± (0.6 + 0.4L) mm,\n(b) The maximum permissible error on tape measures on inspection shall be twice that specified for verification, the method of verification remaining unchanged.\n(c) Steel tape measures of nominal length 0.5 m to 5 m shall belong to accuracy Class I or Class II.\n(d) Tape measures of nominal length above 5 m shall belong to accuracy Class I, Class II or Class III.",
"footnote": "",
"is_definition": false,
"sort_order": 210
},
{
"number": "9",
"title": "9. Markings",
"chapter": null,
"content": "(a) The steel tape measures shall be marked at a suitable place near the end and on the container, where provided with the following markings:\n(i) nominal length in metre,\n(ii) an indication of the location of the zero of the scale,\n(iii) the manufacturer's name or trade mark or both,\n(iv) class of accuracy: I, II or III in an oval,\n(v) model approval number issued by the Central Government.\n(b) The inscriptions shall be clearly visible and legible.\n(c) Advertising inscriptions, if made, shall be carried out in such a manner that they do not intrude in any way with the use of the tape measure.",
"footnote": "",
"is_definition": false,
"sort_order": 211
},
{
"number": "10",
"title": "10. Sealing",
"chapter": null,
"content": "Part VIII - Surveying Chains",
"footnote": "",
"is_definition": false,
"sort_order": 212
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 213
},
{
"number": "2",
"title": "2. Definitions",
"chapter": null,
"content": "(a) Surveying chain - An instrument for measuring the surface distance between two points.\n(b) Length of chain - The distance between the outside edges of the handles when fully stretched.\n(c) Tallies - Metallic tags or indicators of distinctive pattern fixed at (various points) of the chain, to facilitate quick reading of fractions of a chain.",
"footnote": "",
"is_definition": true,
"sort_order": 214
},
{
"number": "3",
"title": "3. Material",
"chapter": null,
"content": "Components\nMaterial\nHandle\nBrass Castings\nEye Bolt Collar\nBrass suitable for free cutting and high speed machine work\nRing Link, Small Link, Large\nGalvanised mild street wire 4 mm\nLink, Connecting\nTally Indicating ring\nBrass sheet or galvanised sheet Brass wire",
"footnote": "",
"is_definition": false,
"sort_order": 215
},
{
"number": "4",
"title": "4. Constructional details",
"chapter": null,
"content": "(a) The nomenclature of the different parts of the chain and their dimensions shall be as indicated in Figure 27, 28 & 29.\n(b) The tallies shall be fixed at every fifth metre along the chain, small rings shall be fixed at every metre, except where tallies are attached. Tallies shall have distinctive shapes depending on their position in the chain as shown in Figure 27 and 28.\n(c) connecting links between two large links shall be oval in shape, the central one being a circular ring.\n(d) To facilitate holding the arrows (chain pains) in position with the handle of the chain, a groove shall be cut on the outside surface of the handle as shown in Figure 29. The radius of the groove shall correspond to the radius of the arrows.\n(e) The handle joint shall have flexibility in order that it may be possible to swivel the handle round the eye bolt. A swivel may also be provided at the middle of the chain.",
"footnote": "",
"is_definition": false,
"sort_order": 216
},
{
"number": "5",
"title": "5. Permissible error",
"chapter": null,
"content": "(a) When measured with a tension of 80 newtons every metre length shall be correct with an error not exceeding ± 2 mm.\n(b) The permissible errors shall be the same for verification and inspection.",
"footnote": "",
"is_definition": false,
"sort_order": 217
},
{
"number": "6",
"title": "6. Marking",
"chapter": null,
"content": "(a) The tallies used for marking the distances in chain shall be marked with letters ^eh* and 'm' (See Figure 29).\n^eh*\n(b) The length of the chain, 20 m or 30 m, as the case may be, shall be indelibly marked over the handle (See Figure 29).\n(c) The chains shall be indelibly marked, on the, reverse side of the surface of the handle having the denominations with the manufacturer's name or trade mark.\nNote : The abbreviation eh may be indicated in the regional script.\nNote :\neh",
"footnote": "",
"is_definition": false,
"sort_order": 218
},
{
"number": "7",
"title": "7. Provision for stamping",
"chapter": null,
"content": "Part IX - Tapes for Use in Measurement of Oil Quantities",
"footnote": "",
"is_definition": false,
"sort_order": 219
},
{
"number": "1",
"title": "1. General",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 220
},
{
"number": "2",
"title": "2. Definitions",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": true,
"sort_order": 221
},
{
"number": "3",
"title": "3. Denominations",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 222
},
{
"number": "4",
"title": "4. Material",
"chapter": null,
"content": "(a) Tape - The steel used shall have a minimum tensile strength of 1500 M Pa.\n(b) Dip weights or dip bobs - The dip weights shall be made of brass or other non-sparking or low sparking material, sufficiently hard to resist damage by contact with steel.",
"footnote": "",
"is_definition": false,
"sort_order": 223
},
{
"number": "5",
"title": "5. Dip tape",
"chapter": null,
"content": "(a) The dip tape shall be of the following dimensions :\n(b) Graduations\n(i) The tape shall be marked legibly and indelibly on one side only with a line at every millimetre or five millimetres, centimetre, decimetre and metre. The height of marking lines shall be as follows:\nUnit of graduation\nApproximate height of graduation mm\nMillimetre\n4\nFive mililmetres\n6\nCentimetre\n8\nDecimetre\nFull width of the tape\nMetre\nFull width of the tape\n(c) The tape shall be so made that it is capable of being wound on a drum and held in a winding frame or case.\n(d) The free end of the tape shall be fitted with the dip weight or arrangements provided for attaching the dip weight.",
"footnote": "",
"is_definition": false,
"sort_order": 224
},
{
"number": "6",
"title": "6. Dip weights",
"chapter": null,
"content": "(a) Dip weights shall be of two types, light and heavy, and shall be of cylindrical torpedo shape. The dimensions for light and heavy dip weights shall be as shown in Figure 30.\n(b) The light type may either be fixed permanently to the tape or attached separately to it by any suitable device.\n(c) The heavy type shall be attached to the tape by a swivel hook (See Figure 31).\n(d) The dip weight shall have the lengths of graduation and weights given below:\nLight\nHeavy\nLength of graduations from bottom weight\n150 mm 700 ± 50 g\n150 mm 1500 ± 50g\n(e) The dip weight shall be graduated in a manner similar to the tape.\n(f) The graduations on the dip weight shall begin from its bottom and shall be carried over in such a manner that when the dip weight is attached to the tape the graduations are continuous from the weight to the tape.",
"footnote": "",
"is_definition": false,
"sort_order": 225
},
{
"number": "7",
"title": "7. Permissible error",
"chapter": null,
"content": "(a)\nBetween any two adjoining mm and cm lines\nNot more than ± 0.2 mm\n(b)\nBetween any two adjoining decimetre and metre lines\nNot more than ± 0.4 mm\n(c)\nFrom zero to the points specified below :\n(i) One metre mark\n± 0.4 mm\n(ii) Two metre mark\n± 0.6 mm\n(iii) Five metre mark\n± 1.0 mm\n(iv) Any metre mark beyond the first five metres\n± 1.0 mm for the first five metres plus 0.5 mm for each\n\t\t\t\tadditional five metres or part thereof subject to a maximum error\n\t\t\t\tof 2.0 mm.",
"footnote": "",
"is_definition": false,
"sort_order": 226
},
{
"number": "8",
"title": "8. Marking",
"chapter": null,
"content": "(a) Every centimetre, decimetre and metre shall be marked with international form of Indian numerals. The decimetre and metre numerals shall be in bold type. The metre divisions shall, in addition, bear the designation ^eh* or 'm' or both. The end of the tape measure shall be marked with word ^ehVj* or 'metre' both or both.\n^eh*\n^ehVj*\n(b) On the ungraduated side and on the case of each tape and also on the dip weight, the name or trade-mark of the manufacturer and the denominations shall be legibly marked. In addition, direction of winding shall also be legibly marked on the case or reel. Suitable provisions shall be made for Legal Metrology Officer's stamps on the dip weight and the tape.\n(c) Every dip weight and dip tape shall be suitably marked to identify them with each other.\nNote : The word ^ehVj* and abbreviation ^eh* may be indicated in the regional script.\nNote :\n^ehVj*\n^eh*\nSeventh Schedule - Heading - A\n[See Rule 13]\n[See Rule 13]\nSpecification for Non-Automatic Weighing Instruments\nSpecification for Non-Automatic Weighing Instruments\nPart I\nTerminology\nTerminology",
"footnote": "",
"is_definition": false,
"sort_order": 227
},
{
"number": "1",
"title": "1. General definitions",
"chapter": null,
"content": "Note : Terms such as \"indicate\", \"indicating component\" and their derivatives do not include printing.\nNote :\n- graduated or non-graduated,\n- self-indicating, semi-self-indicating or non-self indicating.\nNote : In this specification, a non-automatic weighing instrument is called an \"instrument\".\nNote :\n(i) Graduated instrument\n(ii) Self-indicating instrument\n(iii) Semi-self indicating instrument\n(iv) Electronic instrument\n(v) Instrument with price scales\n(vi) Price computing instrument\n(vii) Price-labelling instrument\n(viii) Self-service instrument\n(3) Indication provided by an instrument\n(i) Printing indication\n(ii) Indication, signals and symbols that are not primary indications.",
"footnote": "",
"is_definition": true,
"sort_order": 228
},
{
"number": "2",
"title": "2. Construction of an instrument",
"chapter": null,
"content": "(i) Load receptor or pan\n(ii) Load transmitting device\n(iii) Load-measuring device\n(i) Electronic device\nNote : An electronic device, as defined above, may be a complete instrument (e.g. instrument for direct sales to the public) or parts of an Instrument (e.g. indicator).\nNote :\n(ii) Electronic sub-assembly\n(iii) Electronic component\n(i) Indicating component\n(ii) Scale mark\n(iii) Scale base\n(i) Device for interpolation of reading (Vernier)\n(ii) Complementary indicating device\n(iii) Indicating device with a differentiated scale division\n(i) Levelling device\n(ii) Zero setting device\n(a) Non automatic zero setting device\nDevice for setting the indication to zero by an operator.\n(b) Semi automatic zero setting device\nDevice for setting the indication to zero automatically following a manual control.\n(c) Automatic zero-setting device\nDevice for setting the indication to zero automatically without the intervention of an operator.\n(d) Initial zero-setting device\nDevice for setting the indication to zero automatically at the time the instrument is switched on and before it is ready for use.\n(iii) Zero tracking device\n(iv) Tare device\n(a) Tare balancing device : Tare device without indication of the tare value when the instrument is loaded.\n(b) Tare weighing device : Tare device that stores the tare value and is capable of indicating or printing it whether or not the instrument is loaded,\n(v) Preset tare device\n(vi) Locking device\n(vii) Auxiliary verification device\n(viii) Selection device for load receptors and load measuring devices\n(ix) Indication stabilizing device",
"footnote": "",
"is_definition": false,
"sort_order": 229
},
{
"number": "3",
"title": "3. Metrological characteristics of an instrument",
"chapter": null,
"content": "(i) Maximum weighing capacity, not taking into account the additive tare capacity.\n(ii) Minimum capacity (Min)\n(iii) Self-indication capacity\n(iv) Weighing range\n(v) Extension Interval of self-indication\n(vi) Maximum tare effect (T= + ..., T = -...)\n(vii) Maximum safe load (Lim)\n(i) Scale spacing (instrument with analogue indication)\n(ii) Actual scale interval (d)\n(iii) Verification scale interval (e)\n(iv) Scale interval of numbering\n(v) Number of verification scale intervals (single interval instrument)\nn= Max/e\n(vi) Multi-interval instrument\n(vii) Multiple range instrument",
"footnote": "",
"is_definition": false,
"sort_order": 230
},
{
"number": "4",
"title": "4. Metrological properties of an instrument",
"chapter": null,
"content": "",
"footnote": "",
"is_definition": false,
"sort_order": 231
},
{
"number": "5",
"title": "5. Indications and errors",
"chapter": null,
"content": "(i) Balancing by weights :\n(ii) Analogue indication:\n(iii) Digital indication:\nNote : The following definitions apply only when the indication has been zero before the load has been applied to the instrument.\nNote :\n(i) Gross value (G) :\n(ii) Net value (N):\n(iii) Tare value (T) :\n(i) Preset tare value (PT) :\n(ii) Calculated net value:\n(iii) Calculated total weight value:\n(i) Reading by simple juxtaposition\n(ii) Overall inaccuracy of reading\n(iii) Rounding error of digital indication\n(iv) Minimum reading distance\n(See Figure 32B for illustration of certain terms used)\n(i) Error (of indication)\n(ii) Intrinsic error\n(iii) Initial intrinsic error\n(iv) Maximum permissible error\n(v) Fault\nNote : Principally, a fault is the result of an undesired change of data contained in or flowing through an electronic instrument.\nNote :\n(vi) Significant fault\nNote : For a multi-interval instrument, the value of is that appropriate to the partial weighing range.\nNote :\n(vii) Durability error\n(viii) Significant durability error\nNote 1 : A durability error can be due to mechanical wear and tear or due to drift and acing of electronic parts. The concept of significant durability error applies only to electronic parts.\nNote 1 :\nNote 2 : For a multi-interval instrument, the value of e is that appropriate to the partial weighing range.\nNote 2 :\n(ix) Span stability",
"footnote": "",
"is_definition": false,
"sort_order": 232
},
{
"number": "6",
"title": "6. Influence and reference conditions",
"chapter": null,
"content": "(i) Influence factor\n(ii) Disturbance",
"footnote": "",
"is_definition": false,
"sort_order": 233
},
{
"number": "7",
"title": "7. Performance test",
"chapter": null,
"content": "Part II\nNon-Automatic Weighing Instruments\nNon-Automatic Weighing Instruments",
"footnote": "",
"is_definition": false,
"sort_order": 234
},
{
"number": "1",
"title": "1. Scope",
"chapter": null,
"content": "(1) Beam scale\n(2) Counter machine",
"footnote": "",
"is_definition": false,
"sort_order": 235
},
{
"number": "2",
"title": "2. Principles involved",
"chapter": null,
"content": "(i) The units of mass to be used on an instrument shall be the kilogram (kg) the milligram (mg), the gram (g) and tonne (t).\n(ii) For special application e.g. trade with precious stones, the metric carat (1 carat = 0.2 g) may be used as unit of measurement. A symbol for the carat shall be \"c\".",
"footnote": "",
"is_definition": false,
"sort_order": 236
},
{
"number": "3",
"title": "3. Metrological requirements",
"chapter": null,
"content": "(i) Accuracy classes\nTable 15\nTable 15\nClass\nSymbol\nSpecial accuracy\nI\nHigh accuracy\nII\nMedium accuracy\nIII\nOrdinary accuracy\nIV\n(i) Verification scale interval shall be in the form\n(ii) The verification scale interval for different types of instruments shall be as given in Table 16.\nTable 16\nTable 16\nType of instrument\nVerification scale interval\nGraduated, without auxiliary indicating device\ne = d\nGraduated, with auxiliary indicating device\ne is chosen by the manufacturer according to requirement in\n\t\t\t\t\tsub-paragraph (3) and clause (iii) of sub-paragraph (5) of this\n\t\t\t\t\tparagraph.\nNon-graduated\ne is chosen by the manufacture according to sub-paragraph (3)\n\t\t\t\t\tof this paragraph.\n(i) The verification scale interval, number of verification scale interval and the minimum capacity in relation to the accuracy class of an instrument, shall be as given in Table 17.\nTable 17\nTable 17\nAccuracy class\nVerification scale interval\nNumber of verification scale intervals n =\n\t\t\t\t\tMax/e ______________________\nMinimum capacity\nminimum\nmaximum\nSpecial I\n0.001 g ≤ e\n50000*\n-\n100 e\nHigh II\n0.001 g ≤ e ≤ 0.05 g\n100\n100000\n20 e\n0.1 g ≤ e\n5000\n100000\n50 e\nMedium III\n0.1 g ≤ e ≤ 2g\n100\n10000\n20 e\n5 g ≤ e\n500\n10000\n20 e\nOrdinary IV\n5 g ≤ e\n100\n1000\n10 e\nNote : For values of 'e' less than 1 mg in respect of class I accuracy instruments, e shall be taken to be equal to 1 mg for the purpose of verification/inspection.\nNote :\n(ii) On multiple range instruments, if the verification scale intervals are e 1 , e 2 .... e r with e 1 e 2 ... e r , Min, n and Max shall be indexed accordingly.\n(iii) On multiple range instruments each range shall be treated as an instrument with one range.\n(iv) For special application that are clearly marked on the instrument, an instrument may have weighing ranges in classes I and II or in classes II and III. The instruments as a whole shall then comply with the more severe requirements of sub-paragraph (9) of this paragraph applicable to either of the two classes.\n(i) Partial weighing range\nn 1 = Max i /e i\n(ii) Accuracy class\n(iii) Maximum capacity of partial weighing ranges\nTable 18\nTable 18\nClass\nI\nII\nIII\nIV\nMax i /e i +1\n≥ 50000\n≥ 5000\n≥ 500\n≥ 50\n(iv) Instrument with a tare device\n(i) Type and application\n- a device with a rider, or\n- a device for interpolation of reading, or\n- a complementary indicating device (*) or\n- an indicating device with a differentiated scale division (**),\n(ii) A multi-interval instrument shall not be fitted with an auxiliary indicating device.\n(iii) Verification scale interval\nTable 19\nTable 19\nd =\n0.1 g\n0.2 g\n0.5 g\ne =\n1 g\n1 g\n1 g\n(i) Example of a complementary indicating device (*)\n(ii) examples of indicating devices each with a differentiated scale division (**)\n(iv) Minimum capacity\n(v) Minimum number of verification scale intervals\n(i) Values of maximum permissible errors on verification/reverification\nTable 20\nTable 20\nMaximum permissible errors on verification/re-verification\nFor loads m expressed in verification scale\n\t\t\t\t\tintervals e\nClass I\nClass II\nClass III\nClass IV\n±0.5e\nMin ≤ m ≤ 50000\nMin ≤ m ≤ £ 5000\nMin ≤ m ≤ 500\nMin ≤ m ≤ 50\n±1e\n50000 < m ≤ 200000\n5000 ≤ m ≤ 20000\n500 ≤ m ≤ 2000\n50 < m ≤ 200\n±1.5e\n200000 < m\n20000 < m ≤ 100000\n2000 < m ≤ 10000\n200 < m ≤ 1000\n(ii) Values of maximum permissible errors in inspection\n(iii) Basic rules concerning the determination of errors\n(a) Influence factors\nErrors shall be determined under normal test condition. When the effect of one factor is being evaluated, all other factors are to be kept relatively constant, at a value close to normal.\n(b) Maximum permissible errors for net values\nThe maximum permissible errors apply to the net value of the load for every possible tare load, except preset tare values\n(c) Tare weighing device\nThe maximum permissible error for a tare weighing device is the same, for any tare value as those of the instrument, for the same value of load.\n(i) Repeatability\n(ii) Eccentric loading\n(a) Unless otherwise specified hereafter, a load corresponding to 1/3 of the sum of the maximum capacity and the corresponding maximum additive tare effect shall be applied.\n(b) On an instrument with a load receptor having n points of support, with n > 4, the fraction 1/(n-1) of the sum of the maximum capacity and the maximum additive tare effect shall be applied to each point of support.\n(c) On an instrument with a load receptor subject to minimal off-centre loading (e.g. tank, hopper) a test load corresponding to one-tenth of the sum of the maximum capacity and the maximum additive tare effect shall be applied to each point or support.\n(d) On an instrument used for weighing rolling loads (e.g. vehicle scale, rail suspension instrument) a rolling test load corresponding to the usual rolling load, the heaviest and the most concentrated one which may be weighted, but not exceeding 0.8 times the sum of the maximum capacity and the maximum additive tare effect, shall be applied at different points on the load receptor.\n(iii) Multiple indicating devices\n(iv) Different positions of equilibrium\n(i) Non-self indicating instrument\n(ii) Self or semi-self indicating instrument\n(a) Analogue indication\nAn extra load equivalent to the maximum permissible error for applied load when placed gently on or withdrawn from the Instrument at equilibrium shall cause a permanent displacement of the indicating element corresponding to not less than 0.7 times the extra load.\n(b) Digital indication\nAn additional load equal to 1.4 times the actual, scale interval, when gently placed on or withdrawn from the instrument at equilibrium shall change the initial indication.\n(i) Tilting\n(a) For instrument of class II, III or IV liable to be tilted, the influence of tilting shall be determined under the effect of a lengthwise or transverse tilting equal to 2/1000 or corresponding to the limiting value of till ting marked on, or indicated by a level indicator, whichever is the greater tilt.\nThe absolute value of the difference between the indication of the instrument in its reference position (not tilted) and the indication in the tilted position shall not exceed:\n- at no load, two verification scale intervals, (the instrument having first been adjusted to zero at no load in its reference position) except instruments of class II.\n- at self indication capacity and at maximum capacity; the maximum permissible error (the instrument having been adjusted to zero at no load both in the reference and in the tilted position).\nAn instrument shall be fitted with a levelling device and a level indicator fixed firmly on the instrument in a place clearly visible to the user, unless the instrument is:\nfreely suspended, or\ninstalled in a fixed position, or\ncomplying with the requirements on tilting when tilted to 5% in any direction.\nThe limiting value of the level indicator shall be obvious, so that tilting is easily noticed.\nNote : Limiting value of tilting: Displacement of 2 mm from a central position.\nNote :\n(b) On a class I instrument, the limiting value of tilting shall correspond to a tilt of no more than 2/1000 otherwise the instrument shall meet the requirement for instruments of class II.\n(ii) Temperature\n(a) Prescribed temperature limits\nIf no particular working temperature is stated in the descriptive markings of an instrument, this instrument shall maintain its metrological properties within the following temperature limits:\n-10°C + 40°</ul></p>",
"footnote": "",
"is_definition": false,
"sort_order": 237
}
],
"metadata": {
"Act ID": "Act2370",
"Act Number": "Published vide Notification No. G.S.R. 71(E), dated 7th February 2011",
"Enactment Date": "",
"Act Year": "2011",
"Short Title": "The Legal Metrology (General) Rules, 2011",
"Type": "CENTRAL",
"Location": "India (Central)"
},
"updated_at": "2026-09-29 21:55:18"
}