3. It may be assumed that 2/3rd of the number is males and 1/3rd are females.

Sanitation Requirement For Medical/ Hospital Occupancy
Sanitation Requirement For Medical/ Hospital Occupancy
Sl. No:
Sl. No:
Fitments
Fitments
Hospitals with indoor patients' ward
Hospitals with indoor patients' ward
Hospital with outdoor patients
Hospital with outdoor patients
Administration Building
Administration Building
For males and females
For males
For females
For male personnel
For females personnel
(1)
(2)
(3)
(4)
(5)
(6)
(7)
1
Water closet
One for every 8 beds or part thereof
One for every 100 persons or part thereof
Two for every 100 persons or part thereof.
One for every 25 persons or part thereof.
One for every 15 persons or part thereof.
2
Ablution Taps
One in each water closet plus one water tap with
draining arrangement in the vicinity of water closets and urinals
for every 50 beds or part thereof.
One in each water closet. One water tap with
draining arrangements shall be provided for every 50 persons or
part thereof in the vicinity of water closet and urinals.
One in each water closet. One water tap with
draining arrangements shall be provided for every 50 persons or
part thereof in the vicinity of water closet and urinals.
3
Wash basins
Two upto 30 beds; add one for every additional
30 beds or part thereof.
One for every 100 persons or part thereof.
One for every 25 persons or part thereof.
4
Baths with shower
One bath with shower for every 8 beds or part
thereof
One on each floor
5
Bed pan washing sink
One for each ward
6
Cleaners' sink
One for each ward minimum
One per floor minimum
One per floor minimum
7
Kitchen sink and Dish washers (where kitchen is
provided)
One for each ward
8
Urinals
One for every 50 persons of part thereof.
Nil -Upto 6 person 1 - for 7 - 20 persons 2
for 21 - 45 persons 3 for 46 - 70 persons 4 for 71 - 100
persons From 101 to 2000 persons, add at the rate of 3%. For
over 200 persons, add at the rate of 2.5%.