(i) dimensioned plan(s) and sectional drawing(s) showing the levels and depths of cutting at all places in respect of excavations for building construction and land development works;
(ii) drawings, specifications and details of temporary and permanent protective measures proposed; and
(iii) drawings, specifications and details of slabs, beams, columns, retaining walls etc. proposed at the ground floor level and below;
(iv) details of piles if any, including their drawings, specifications, erection methods and the like.
(i) refer the matter within 5 days to the Technical Expert Committee constituted as per sub rule (13) and convene a meeting of the Committee,
(ii) intimate the nature of complaints to the applicant and call for details and explanation if so desired by the Committee,
(iii) arrange for site inspections, hearing of the applicants and/or petitioners, verification of records and arrange for tests if so required by the Committee and
(iv) take up further action as per the recommendations of the Committee.
Section 12 • The Kerala Panchayat Buildings Rules, 2011
12. Approval of site and plans and issue of permit where excavations to a depth of more than 1.5 metres is involved.
the-kerala-panchayat-buildings-rules-2011-sec-12.json
•
Section 12
{
"act_title": "The Kerala Panchayat Buildings Rules, 2011",
"act_slug": "the-kerala-panchayat-buildings-rules-2011",
"section_label": "Section",
"section": {
"number": "12",
"title": "12. Approval of site and plans and issue of permit where excavations to a depth of more than 1.5 metres is involved.",
"chapter": null,
"content": "(i) dimensioned plan(s) and sectional drawing(s) showing the levels and depths of cutting at all places in respect of excavations for building construction and land development works;\n(ii) drawings, specifications and details of temporary and permanent protective measures proposed; and\n(iii) drawings, specifications and details of slabs, beams, columns, retaining walls etc. proposed at the ground floor level and below;\n(iv) details of piles if any, including their drawings, specifications, erection methods and the like.\n(i) refer the matter within 5 days to the Technical Expert Committee constituted as per sub rule (13) and convene a meeting of the Committee,\n(ii) intimate the nature of complaints to the applicant and call for details and explanation if so desired by the Committee,\n(iii) arrange for site inspections, hearing of the applicants and/or petitioners, verification of records and arrange for tests if so required by the Committee and\n(iv) take up further action as per the recommendations of the Committee.",
"footnote": "",
"is_definition": false,
"sort_order": 14
},
"prev_section": "11",
"next_section": "13"
}