(a) It shall be of approved material and construction;
(b) It shall be effective and stable when floating either way up;
(c) It shall be fitted with fixed or collapsible bulwarks of wood, canvas, or other suitable material around both the top and bottom platforms;
(d) It shall have a line security becketed round the outside;
(e) It shall be of such strength that it can be launched or thrown from the ship's deck without being damaged and if intended to be thrown it shall be of such size and weight that it can easily be handled;
(f) It shall have not less than three cubic feet of air-cases of equivalent buoyancy appliances for each person to be carried thereon;
(g) It shall have a deck area of not less than four square feet for each person to be carried thereon, and it shall effectively support the occupants out of the water.
(h) The air-cases or equivalent buoyancy appliances shall be placed as near as possible to the sides of the life-raft, and such buoyancy appliances shall not be dependent on inflation by air.
Section 17 • The Indian Pilgrim Ships Rules, 1933
17. General requirements for life-rafts.
the-indian-pilgrim-ships-rules-1933-sec-17.json
•
Section 17
{
"act_title": "The Indian Pilgrim Ships Rules, 1933",
"act_slug": "the-indian-pilgrim-ships-rules-1933",
"section_label": "Section",
"section": {
"number": "17",
"title": "17. General requirements for life-rafts.",
"chapter": null,
"content": "(a) It shall be of approved material and construction;\n(b) It shall be effective and stable when floating either way up;\n(c) It shall be fitted with fixed or collapsible bulwarks of wood, canvas, or other suitable material around both the top and bottom platforms;\n(d) It shall have a line security becketed round the outside;\n(e) It shall be of such strength that it can be launched or thrown from the ship's deck without being damaged and if intended to be thrown it shall be of such size and weight that it can easily be handled;\n(f) It shall have not less than three cubic feet of air-cases of equivalent buoyancy appliances for each person to be carried thereon;\n(g) It shall have a deck area of not less than four square feet for each person to be carried thereon, and it shall effectively support the occupants out of the water.\n(h) The air-cases or equivalent buoyancy appliances shall be placed as near as possible to the sides of the life-raft, and such buoyancy appliances shall not be dependent on inflation by air.",
"footnote": "",
"is_definition": false,
"sort_order": 10
},
"prev_section": "16",
"next_section": "18"
}